• 제목/요약/키워드: Closing Velocity

검색결과 109건 처리시간 0.025초

A preliminary simulation for the development of an implantable pulsatile blood pump

  • Di Paolo, Jose;Insfran, Jordan F.;Fries, Exequiel R.;Campana, Diego M.;Berli, Marcelo E.;Ubal, Sebastian
    • Advances in biomechanics and applications
    • /
    • 제1권2호
    • /
    • pp.127-141
    • /
    • 2014
  • A preliminary study of a new pulsatile pump that will work to a frequency greater than 1 Hz, is presented. The fluid-structure interaction between a Newtonian blood flow and a piston drive that moves with periodic speed is simulated. The mechanism is of double effect and has four valves, two at the input flow and two at the output flow; the valves are simulated with specified velocity of closing and reopening. The simulation is made with finite elements software named COMSOL Multiphysics 3.3 to resolve the flow in a preliminary planar configuration. The geometry is 2D to determine areas of high speeds and high shear stresses that can cause hemolysis and platelet aggregation. The opening and closing valves are modelled by solid structure interacting with flow, the rhythmic opening and closing are synchronized with the piston harmonic movement. The boundary conditions at the input and output areas are only normal traction with reference pressure. On the other hand, the fluid structure interactions are manifested due to the non-slip boundary conditions over the piston moving surfaces, moving valve contours and fix pump walls. The non-physiologic frequency pulsatile pump, from the viewpoint of fluid flow analysis, is predicted feasible and with characteristic of low hemolysis and low thrombogenesis, because the stress tension and resident time are smaller than the limit and the vortices are destroyed for the periodic flow.

Analysis of Blood Flow Interacted with Leaflets in MHV in View of Fluid-Structure Interaction

  • Park, Choeng-Ryul;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.613-622
    • /
    • 2001
  • Interaction of blood flow and leaflet behavior in a bileaflet mechanical heart valve was investigated using computational analysis. Blood flows of a Newtonian fluid and a non-Newtonian fluid with Carreau model were modeled as pulsatile, laminar, and incompressible. A finite volume computational fluid dynamics code and a finite element structure dynamics code were used concurrently to solve the flow and structure equations, respectively, where the two equations were strongly coupled. Physiologic ventricular and aortic pressure waveforms were used as flow boundary conditions. Flow fields, leaflet behaviors, and shear stresses with time were obtained for Newtonian and non-Newtonian fluid cases. At the fully opened phase three jets through the leaflets were found and large vortices were present in the sinus area. At the very final stage of the closing phase, the angular velocity of the leaflet was enormously large. Large shear stress was found on leaflet tips and in the orifice region between two leaflets at the final stage of closing phase. This method using fluid-structure interaction turned out to be a useful tool to analyze the different designs of existing and future bileaflet valves.

  • PDF

호안제체에서 Non-Darcy 흐름해석 (Analysis of Non-Darcy Flour in Tide Embankment)

  • 최흥식
    • 한국수자원학회논문집
    • /
    • 제37권2호
    • /
    • pp.87-96
    • /
    • 2004
  • Li 등(1998)이 제안한 호안제체를 통과하는 non-Darcy 흐름에 대한 i- V관계식의 해석결과는 실측자료와의 비교결과 잘 맞는 것으로 나타났다. 따라서 이식의 사용은 현장에 적용성이 있는 것으로 평가되었고, 적용에 따른 변수인 공극율의 정확한 값의 입력이 요구된다. 관수로흐름과 Taylor의 평균수리수심에 기초한 사석에 적용되는 non-Darcy 특성의 흐름은 블록 및 케이슨 호안에도 적용 가능한 것으로 평가된다. 호안제체를 통과하는 흐름에 대한 정확한 계산은 호안의 최종체절 개방구간에서의 정확한 유속의 산정은 물론 축조 후의 호안 내의 수위의 변화를 예측할 수 있다.

전산유체해석(CFD)을 이용한 밸브의 급폐쇄에 따른 다중 배관 수격 현상에 관한 연구 (Study on a Multi-pipe Water Hammer Phenomenon by using CFD of Rapid Valve Closing)

  • 박노석;김성수;강문선;최종웅
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.479-487
    • /
    • 2013
  • This study was to investigate characteristics for the pressure wave propagation and the maximum pressure near a rapid closure valve which was installed the end of multi piping network. The multi piping network consists of one inlet and three outlet with straight pipes. The diameter of the pipes including the valve was 100 mm, 80 mm, 80 mm respectively. The valve was rapidly closed with the instantaneous time which was 0.023s in the level for the water hammer. For the simulation, the influence of the pipe thickness and deformation due to pressure-wave-propagation was not considered. CFD was conducted under the following condition : the initial pressure was 1bar in the inlet and the mass flow rate was 7.83 kg/s in the outlet(the velocity in the pipe with 100 mm diameter was 1 m/s). As the valve have conditions that were status with and without fluid flow in the pipe after valve closing, the maximum pressure change and the frequency analysis were examined. As the results, the case that was status with fluid flow appeared the higher maximum pressure than another's, the maximum frequency band was about 10 ~ 11 Hz.

자동 닫힘 기능을 갖는 마찰힌지 개발에 관한 연구 (A Study on the Development of Friction Hinge with Automatic Closed Function)

  • 예상돈;민병현
    • 한국기계가공학회지
    • /
    • 제13권1호
    • /
    • pp.107-114
    • /
    • 2014
  • A friction hinge system which moves without power was designed and developed using the principle of friction force, which is caused by interference between the inner diameter of a silicon cap and the outer diameter of a cylindrical roller bearing with one-way rotation in a counterclockwise direction. The system was applied to the lid of buffet ware, which moved up by external force and moved down by gravitational force. However, design conditions which included a rotation angle of the hinge of more than 80 degrees and a closing time of more than 20 seconds were required when the lid of the buffet ware closed due to gravitational force. The design safety of the friction hinge body connected to the lid of the buffet ware from the hinge system was checked on the basis of structural, fatigue and thermal analyses. The material of the shaft, cap and flange among the hinge elements was changed to polyethylene from steel to reduce the weight of the friction hinge system. An injection molding simulation was performed and injection molds of the shaft, cap and flange were created. The weight of the hinge system was decreased from 805g to 219g.

연료분무의 위상도플러 측정과 확률밀도함수의 도출 (Phase Doppler Measurements and Probability Density Functions in Liquid Fuel Spray)

  • 구자예
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.1039-1049
    • /
    • 1994
  • The intermitternt and transient fuel spray have been investigated from the simultaneous measurement of droplet sizes and velocities by using Phase/Doppler Particle Analyzer(PDPA). Measurement have been done on the spray axis and at the edge of the spray near nozzle at various gas-to-liquid density ratios(.rho./sub g//.rho./sub l/) that ranges from those found in free atmospheric jets to conditions typical of diesel engines. Probability density distributions of the droplet size and velocity were obtained from raw data and mathematical probability density functions which can fit the experimental distribations were extracted using the principle of maximum likelihood. In the near nozzle region on the spray axis, droplet sizes ranged from the lower limit of the measurement system to the order of nozzle diameter for all (.rho./sub g/ /.rho./sub l/) and droplet sizes tended to be small on the spray edge. At the edge of spray, average droplet velocity peaked during needle opening and needle closing. The rms intensity is greatly incresed as the radial distance from the nozzle is increased. The probability density function which can best fit the physical breakage process such as breakup of fuel drops is exponecially decreasing log-hypebolic function with 4 parameters.

전치 유도각의 인위적 증가에 의한 저작근과 하악 운동 양상의 변화에 대한 연구 (A STUDY FOR THE CHANGES OF THE MASTICATORY MUSCLES AND THE MANDIBULER MOVEMENT EFFECTED BY INTENTIONAL INCREASE OF ANTERIOR GUIDANCE ANGLE)

  • 이용식;최부병
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.245-257
    • /
    • 1998
  • This study was performed to measure the changes of the mandibular movement and the masticatory muscular activities - anterior temporal and masseter muscle of both side - reflected by intentional increase of anterior guidance angie. For this study, 5 volunteers (3 males and 2 females with average age of 24.0) were selected. Each volunteer had Angle's classification I and did not have any missing tooth except third molar and any extensive restorations. Metallic guide plate was made at volunteer's working model fabricated by improved dental stone and cemented to the palatal surface of maxillary central incisor using resin cement(Panavia $21^{(R)}$) and then adjusted not to give any occlusal interferences at intercuspal position. The activity of masticatory muscles and the changes of mandibular movement were recorded by EMG and Sirognathograph in Biopak analysing system(Bioresearch Inc., Milwaukee, Wisconsin, USA). Measurement was done at before experiment, immediatley after placement, 1 week after placement, immediately after removal, and 1 week after removal. The results were as follows: 1. Moderate phonetic disturbance and mild headache were occured to 3 volunteers for 2 days after setting and 1 volunteer had positive reaction to percussion and slight midline diastema. But all of these clinical signs were diappeared 1 week after removal and the other volunteer did not have any special clinical sign. 2. In the EMG of the mandibular rest position, the mean value of anterior tempotal muscle was increased immediately after placement(p<0.01) and then decreased 1 week after placement(p<0.05) and increased 1 week after removal(p<0.05) but not recovered as before experiment. The mean value of masseter muscle was decreased during the experiment period. 3. In the EMG during mandibular protrusive movement, all muscular activity was decreased during the experiment period. Reduced activity was not recovered 1 week after removal(p<0.03). 4. During the habitual opening, anteroposterior movement of mandible was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not statistically significant(p>0.1). Vertical movement was not shown significant difference during the experiment period(p>0.1). Lateral movement was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not recovered as before experiment. The opening and closing velocity of mandible was shown minor changes but not statistically significant. 5. During the habitual opening, anteroposterior movement of mandible was decreased 1 week after placement(p<0.05) and then increased immediately after removal and recovered 1 week after removal as before experiment. Vertical movement was not shown significant changes. Lateral displacement of mandible was increased continuously and recovered 1 week after removal. Opening velocity was temporarily increased immediately after removal but recovered and closing velocity was not shown significant changes. 6. During the right side chewing, anteroposterior movement of mandible was increased immediately after removal but recovered and vertical movement was not shown statistically significant results. Lateral displacement and velocity of mandible were not shown significant results. 7. During the left side chewing, the changes of mandibular movement pattern were not shown statistically significant results.

  • PDF

진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구 (A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker)

  • 이기선;박정철;추순남
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2503-2508
    • /
    • 2014
  • 본 연구는 진공차단기 기계식 보조접점(MOC)의 구조적인 취약성을 해결하기 위해 전자식 센서 기술을 이용한 전자식 보조접점(EOC) 개발에 선행되어야할 센서의 선정 및 노이즈 시험에 관한 것으로, 기존 기계적 보조접점(MOC)에서 발생하는 반복적인 떨림 및 반동 현상에 의한 접점 오동작을 최소화하는 제품을 개발하는 것을 최종 목표로 하였다. 실험 결과, 차단기 투입 및 개방시 개방시의 써지전압 상승속도가 투입시 보다 4.2배 빠른 것으로 측정되었고, 소음크기는 각각 120dB, 110dB로 측정되었다. 상용주파과전압 60kV를 인가하였을 때 진공차단기 투입 및 개방시 센서에서 출력되는 파형은 일그러짐이 없이 정상적으로 동작됨을 알 수 있었다. 그리고 150kV $1.2{\times}50{\mu}s$의 충격파를 인가하였을 때 센서의 투입 및 개방측 출력접점의 전압파형이 일그러짐이 없이 정상상태를 유지하였으며, 2500A의 전류를 인가하였을 때 자계 잡음을 측정한 결과, 전압파형이 일그러짐이 없이 정상적으로 동작하였다.

건강인의 한발 서기 시 다양한 감각 자극이 압력 중심점 이동 면적과 속도에 미치는 영향 (Effects of Various Sensory Stimulation on Surface Area and Velocity of Center of Pressure During One Leg Standing in Healthy Adults)

  • 김가현;탁지연;임학현;정희선;우영근
    • 한국전문물리치료학회지
    • /
    • 제22권3호
    • /
    • pp.41-49
    • /
    • 2015
  • This study aimed to evaluate the surface area and velocity of center of pressure (COP) during one leg standing by stimulating the sensory system in normal adults. Thirty subjects were enrolled in this study. Subjects were asked to stand on one leg during testing conditions. Testing conditions included 6 different sensory stimulations as follows: eyes opened, eyes closed, eyes opened with vibrator, eyes opened with head-mounted display (HMD), eyes opened with vibrator and HMD, and eyes closed with vibrator. During each testing condition, the surface area and velocity of center of pressure were measured. There were significant differences in the mean surface area and the mean velocity of COP between the "eyes opened" condition and the other five testing conditions (p<.05). However, in the comparison between the "eyes closed" and "eyes opened with HMD" conditions, there were no significant differences in the tested parameters. This study shows that closing eyes or keeping eyes opened while using HMD to experience virtual reality has the same effect on one leg standing balance. This finding should be considered in the evaluation or intervention of balance, especially one leg standing balance and balance while standing with a small base of support.

구리-크롬 합금의 조성비에 따른 동적실험 및 진공 인터럽터 충격특성에의 적용 (Dynamic Material Test of Sinter-Forged Cu-Cr Alloy and Application to the Impact Characteristics of Vacuum Interrupter)

  • 송정한;임지호;허훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.447-452
    • /
    • 2004
  • Vacuum interrupters in order to be used in various switch-gear components such as circuit breakers, distribution switches, contactors, etc. spread the arc uniformly over the surface of the contacts. The electrodes of vacuum interrupters are made of sinter-forged Cu-Cr materials for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at intermediate strain rate is obtained from the high speed tensile test machine test and at the high strain rate is obtained from the split Hopkinson pressure bar test. Experimental results from both quasi-static and dynamic compressive tests are interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the amount of chromium content.

  • PDF