• Title/Summary/Keyword: Closet bowl

Search Result 3, Processing Time 0.017 seconds

A study on the Plumbing system noise of closet bowl by water supply pressure (급수압에 따른 대변기 설비소음에 관한 연구)

  • Kim, Hang;Choi, Eun-Suk;Ko, Kwang-Pil;Gl, No-Gab;Lee, Tai-Gang;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.11-16
    • /
    • 2006
  • It appraises that use an indoor noise standard, a NC value which is a noise appraisal, a dB(A) value, a N value in foreign country because it doesn't yet ready an appraisal standard in domestic. Also, It appraises that the supply and drainage noise which could change water supply pressure, $4kg/cm^2,\;3kg/cm^2,\;2kg/cm^2,\;1.5kg/cm^2,\;1kg/cm^2$, bring about a noise and inquires how does noise level indicates according to each instruments. In case of a water supply pressure standard, $3kg/cm^2$, a C-605is $3{\sim}5dB(A)$ lower than another instruments in directly overhead stories. It appears that all of them is similar to level in directly under level except c-407(2)Analyzed the NC value, c-605is the lowest level, NC-50, of a water supply pressure, $4.0kg/cm^2$, c-407 is the highest level, NC-55.(3) In case of N value, which is one of water supply methods in Japan, it is the lowest level, N-55, of a water supply pressure, $4.0kg/cm^2$ same as NC value and C-407is the highest level, N-60.(4) In case of water supply that is likely to noise level, It appears 6dB(A) level gap each instruments, and C-605 is the lowest level, 63.9dB(A).

  • PDF

A Study about Improvement of Multiple Odor of Public Toilet (Dong-gu, Daejeon) (공중화장실 복합악취 및 개선에 관한 연구 (대전광역시 동구))

  • Jo, Soo-Jun;Shin, Je-Youn;Oh, Sang-Soo;Yu, Dae-Yong;Lee, Sung-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.240-245
    • /
    • 2015
  • This study aimed to provide the basic data to establish measures for the management of the public toilets and reduction of the offensive odor through the air dilution olfactory method and instrumental analysis about offensive odor dilution rate of public toilets, focusing on the Dong-gu, Daejeon Metropolitan City, Korea. The offensive odor intensities ranged from 10 degree to 669 degrees in the urinal toilets and from 31 to 464 in closet bowl toilets. Meanwhile, toilets that had offensive odor of more than 2.5, of which a civil complaint can be filed, were researched 6 (33%). Offensive odor intensities were different according to the closet bowl toilets of the flush, fermented and conventional methods and the year of their installation, but not according to the area of the toilets. As a result of the instrumental analysis targeting 6 public toilets to identify the offensive odor substance, the maximal concentration of $NH_3$ was 2.04 ppm and the average concentration was 0.67 ppm, but $H_2S$, $CH_3SH$ and $(CH_3)_3N$ were not detected. In the fermented and conventional public toilets were not soaps, air fresheners and wastebaskets. Just 50% of the flush toilets had toilet tissue.

A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing (대변기 세정시 발생하는 배수소음의 특성변화에 관한 연구)

  • Soul, Soo-Hwan;Jung, Chul-Woon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.789-796
    • /
    • 2007
  • It has been noted, in case of the apartments in collective form, the drainage noise from cleaning of toilet causes many problems in the basement and adjacent rooms, mainly hampering the pleasant housing environment. The problems are increasingly raised by civil complaints with the public offices. Therefore, if the drainage noise generates when wash out of toilet bowl is grasped how the characteristics change according to the sorts of drainpipe, it is considered that the establishment of an effective sound insulation countermeasure could be possible when a civil petition against the drainage noise of apartment house is submitted hereafter. On such viewpoint, this study measured and analyzed the characteristics of drainage noise per the type of drainage pipe, according to KS A ISO $1996-1{\sim}3$, with the horizontal branch pipe and riser pipes in the drainage noise experiment chamber which has the characteristics of the anechoic room. In the result, the pipe type with excellent noise reduction function. The result of this study is considered to become available as fundamental data, to take actions on reduction of drainage noise of the ceiling piping method.