Reduction of the Axial Force of Water Pump Using CFD (전산유체역학을 이용한 워터펌프 축력 저감)

  • Jo, Sok-Hyun;Shin, Dong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.83-87
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) method has been used to investigate the axial force of automotive water pump. As the excessive axial force can make some unexpected problems like impeller interference and coolant leakage we have focused on finding the cause of axial force and its reduction in this paper. First, we have tested the closed type water pump with and without balance hole by the calculation methods. By examining the pressure contour around the impeller, we have found that the axial force arises not only from the pressure difference around shroud but also from the pressure difference around hub. So we have tested two impellers - one is normal open type impeller and the other is open type impeller with modified hub. The results show that the axial force reduction is about 150~200N for normal one and 700N@3000RPM for modified impeller. And the hydraulic efficiency which is important in aspect of engine fuel efficiency is reduced about 6.5% for normal one but increased 4%@3000RPM for modified impeller.

Rastelli operation in Persistent Truncus Arteriosus, Type IV: A Case Report (총동맥간 잔류증 [IV 형]Rastelli 수술 치험 보고)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.333-341
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF

Characteristics of the Flux-lock Type Superconducting Fault Current Limiter According to the Iron Core Conditions (자속구속형 초전도 전류제한기의 철심조건에 따른 특성)

  • Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Cho, Guem-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.38-45
    • /
    • 2006
  • The superconducting fault current limiters(SFCLs) provide the effect such as enhancement in power system reliability due to limiting the fault current within a few miliseconds. Among various SFCLs we have developed a flux-lock type SFCL and exploited a special design to effectively reduce the fault current according to properly adjustable magnetic field after the short-circuit test. This SFCL consists of two copper coils wound in parallel on the same iron core and a component using the YBCO thin film connected in series to the secondary copper coil. Meanwhile, operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. To analyze the operational characteristics, we compared closed-loop with open-loop iron core. When the applied voltage was 200[Vrms] in the additive polarity winding, the peak values of the line current the increased up to 30.71[A] in the closed-loop and 32.01[A] in the open-loop iron core, respectively. On the other hand, in the voltages generated at current limiting elements were 220.14[V] in the closed-loop and 142.73[V] in the opal-loop iron core during first-half cycle after fault instant under the same conditions. We confirmed that the open-loop iron core had lower power burden than in the closed-loop iron core. Consequently, we found that the structure of iron core enabled the flux-lock type SFCL at power system to have the flexibility.

Objective Outcomes of Closed Reduction According to the Type of Nasal Bone Fracture

  • Kang, Chang Min;Han, Dong Gil
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.1
    • /
    • pp.30-36
    • /
    • 2017
  • Background: Nasal fractures have a tendency of resulting in structural or functional complications, and the results can vary according to the type of nasal bone fracture. The aim of this study was to evaluate the objective postoperative results according to the type of nasal bone fractures. Methods: We reviewed 313 patients who had a closed reduction of nasal bone fracture. The classification of nasal bone fracture by Stranc and Robertson was used to characterize the fracture type: frontal impact group type I (FI), frontal impact group type II (FII), lateral impact group type I (LI), lateral impact group type II (LII), and comminuted fracture group (C). For each patient, we tried to use the same axial image section of computed tomographic (CT) scans before and immediately after operation. Postoperative outcomes were classified into 4 grades: excellent (E), good (G), fair (F), and poor (P). We also analyzed postoperative complications by fracture type. Results: Regarding the postoperative CT images, 189 subjects showed E results, 99 subjects showed G, 18 subjects showed F, and 7 subjects showed P reduction. The rate of operation results graded as E by each fracture type was 66.67% in FI, 52.0% in FII, 64.21% in LI, 62.79% in LII, and 21.74% in C. Complications of FI (7.14%), LII (13.95%), and C (13.04%) groups occurred more than in the FII (4.00%) and LI (4.21%) groups. Conclusion: It seems that the operation result by fracture type was better in the FI, LI, and LII type than the FII and C type; after one month, however, LII type showed more complications than other types. The septal fracture can be thought to affect early reduction results in nasal bone fractures.

RELATIVE ORDER AND RELATIVE TYPE BASED GROWTH PROPERTIES OF ITERATED P ADIC ENTIRE FUNCTIONS

  • Biswas, Tanmay
    • Korean Journal of Mathematics
    • /
    • v.26 no.4
    • /
    • pp.629-663
    • /
    • 2018
  • Let us suppose that ${\mathbb{K}}$ be a complete ultrametric algebraically closed field and $\mathcal{A}$ (${\mathbb{K}}$) be the ${\mathbb{K}}$-algebra of entire functions on K. The main aim of this paper is to study some newly developed results related to the growth rates of iterated p-adic entire functions on the basis of their relative orders, relative type and relative weak type.

Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss (압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가)

  • Park You-me;Kim Rack-woo;Kim Jun-gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

Effects of Nucleating Agents on the Morphological, Mechanical and Thermal Insulating Properties of Rigid Polyurethane Foams

  • Kang, Ji-Woung;Kim, Ji-Mun;Kim, Min-Soo;Kim, Youn-Hee;Kim, Woo-Nyon;Jang, Won;Shin, Dae-Sig
    • Macromolecular Research
    • /
    • v.17 no.11
    • /
    • pp.856-862
    • /
    • 2009
  • This study examined the effects of liquid and solid additives on the morphological, mechanical and thermal insulating properties of rigid polyurethane foams (PUFs). The PUFs synthesized with tetramethylsilane (TEMS) as a liquid-type additive showed a smaller average cell size and lower thermal conductivity than those with the aerosil 200 and clay 30B as solid-type additives. When TEMS was added, the average cell size of the PUF became more uniform and finer due to the reduced surface tension of the polymer solution, which increased the nucleation rate and number of bubbles produced and reduced cell size. The PUFs with TEMS showed the highest closed cell contents among the PUFs prepared using TEMS, aerosil 200 and clay 30B. This suggests that the insulation properties of PUF can be determined by both the size of the cell structure and the amount of closed cell contents in the system. The compression and flexural strengths of the PUF increased slightly when the aerosil 200, clay 30B and TEMS were added compared those of the neat PUF. The reaction profiles of the PUFs showed a similar gel and tack tree time with the reaction time among the PUFs synthesized with three different additives and neat PUF. This suggests that the nucleating additives used in this study do not affect the bubble growth of the chemical reaction, and the additives may act as nucleating agents during the formation of PUF. From the above results of the cell size, thermal conductivity, closed cell contents and reaction profile of the PUFs, liquid-type nucleating agent, such as TEMS, is more effective in decreasing the thermal conductivity of the PUF than solid-type nucleating agent, such as aerosil 200 and clay 30B.

Comparative Assessment of Quality Changes in Refrigerated Foods Stored in Open-type and Door-type Refrigerators: Towards Developing Quality Indicators (냉장 중 품질변화 측정 지표 개발을 위한 냉장고 형태별(개방형 및 도어형) 저장 중 주요 냉장 식품의 품질변화 측정)

  • A-Ra Jang;Hyunji Song;Hyunwoo Joung;Euijin Choo;Sun-Young Lee
    • Journal of the FoodService Safety
    • /
    • v.4 no.1
    • /
    • pp.7-20
    • /
    • 2023
  • This study was conducted to investigate the impact of refrigerator type and temperature fluctuations on the quality changes of refrigerated foods. Phycochemical and sensory quality, as well as microbial growth, were measured for various foods stored in open- or door-type refrigerators set at 5℃ during storage. The average temperatures recorded were 11.50±1.14℃ in an open refrigerator, and 6.34±0.97℃ in a closed refrigerator. The average surface temperatures of the food items were 9.60±1.20 and 6.00±0.80℃ for open and closed refrigerators, respectively. Significant changes in color and appearance quality were observed in lettuce, mackerel, ground beef, and cut pineapples when stored in open refrigerators. Ready-to-Eat foods such as gimbap and sandwiches exhibited higher levels of microbiological proliferation when stored in open refrigerators compared to closed refrigerators. Processed foods, such as sterilized milk and packaged tofu, did not show significant differences in quality among various types of refrigerators. The installation of refrigerator doors can effectively minimize temperature fluctuations caused by external factors, thereby reducing variations in food quality. These findings provide essential insights into the quality changes associated with the implementation of refrigerator doors, serving as fundamental data for ensuring optimal food preservation.