• Title/Summary/Keyword: Closed university

Search Result 5,784, Processing Time 0.035 seconds

R-fuzzy F-closed Spaces

  • Zahran A. M.;Abd-Allah M. Azab;El-Rahman A. G. Abd
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.6 no.3
    • /
    • pp.255-263
    • /
    • 2006
  • In this paper, we introduce the concepts of ${\gamma}$-fuzzy feebly open and ${\gamma}$-fuzzy feebly closed sets in Sostak's fuzzy topological spaces and by using them, we explain the notions of ${\gamma}$-fuzzy F-closed spaces. Also, we give some characterization of ${\gamma}$-fuzzy F-closedness in terms of fuzzy filterbasis and ${\gamma}$-fuzzy feebly-${\theta}$-cluster points.

Some Fuzzy Continuous Mappings and Fuzzy Mildly Normal Spaces

  • Ahn, Y. S.;Choi, K. H.;Hur, K.
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.3
    • /
    • pp.280-285
    • /
    • 2001
  • We introduce the new concepts of some fuzzy continuous and closed mappings and study their properties. Also we investigate the properties of fuzzy mildly normal spaces.

  • PDF

A Study on Improving Records Management of Closed Private Universities (폐교 사립대학 기록물 관리 개선 방안에 관한 연구)

  • Lee, Jae-Young;Chung, Yeon-Kyoung
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.19 no.4
    • /
    • pp.35-61
    • /
    • 2019
  • The recent demographic cliff caused the schooling population to steadily decline and the number of college admissions to sharply drop, which led to the prediction of the Ministry of Education wherein 38 universities in Korea will be closed within the next 3 years. As such, the legal, administrative, historical, and informational values of university records shed light on the importance of the follow-up process and management of closed university records. Although closed university records need to be systematically managed according to legal procedures similar to other public records, there is no practical and clear legal standard for the management of such records at present. Moreover, management standards considering the characteristics of (closed) university records and individual universities' situations and specificity have been insufficient. This study, therefore, examines the ambiguous standards for closed university records management and analyzed relevant problems. Furthermore, an integrated management system is suggested as a way to improve the records management of closed universities.

A NOTE ON R-CONVERGENCES AND H-CLOSED SPACES

  • Cho, Seong-Hoon
    • Journal of applied mathematics & informatics
    • /
    • v.11 no.1_2
    • /
    • pp.379-384
    • /
    • 2003
  • In this paper, we obtain a topology $\tau\delta$ on X. From this topology, we obtain some characterizations of if-closed spaces.

On a Generalization of Closed Sets

  • Caldas, Miguel;Ganster, Maximilian;Georgiou, Dimitrios N.;Jafari, Saeid;Popa, Valeriu
    • Kyungpook Mathematical Journal
    • /
    • v.47 no.2
    • /
    • pp.155-164
    • /
    • 2007
  • It is the objective of this paper to study further the notion of ${\Lambda}_s$-semi-${\theta}$-closed sets which is defined as the intersection of a ${\theta}$-${\Lambda}_s$-set and a semi-${\theta}$-closed set. Moreover, introduce some low separation axioms using the above notions. Also we present and study the notions of ${\Lambda}_s$-continuous functions, ${\Lambda}_s$-compact spaces and ${\Lambda}_s$-connected spaces.

  • PDF

Closed-form solution of axisymmetric deformation of prestressed Föppl-Hencky membrane under constrained deflecting

  • Lian, Yong-Sheng;Sun, Jun-Yi;Dong, Jiao;Zheng, Zhou-Lian;Yang, Zhi-Xin
    • Structural Engineering and Mechanics
    • /
    • v.69 no.6
    • /
    • pp.693-698
    • /
    • 2019
  • In this study, the problem of axisymmetric deformation of prestressed $F{\ddot{o}}ppl-Hencky$ membrane under constrained deflecting was analytically solved and its closed-form solution was presented. The small-rotation-angle assumption usually adopted in membrane problems was given up, and the initial stress in membrane was taken into account. Consequently, this closed-form solution has higher calculation accuracy and can be applied for a wider range in comparison with the existing approximate solution. The presented numerical examples demonstrate the validity of the closed-form solution, and show the errors of the contact radius, profile and radial stress of membrane in the existing approximate solution brought by the small-rotation-angle assumption. Moreover, the influence of the initial stress on the contact radius is also discussed based on the numerical examples.

Ultrasonography, Affected Age, Hematology and Clinical Signs according to Open or Closed Cervix in Dogs with Pyometra

  • Lee, Jun-Am;Kim, Ill-Hwa;Hwang, Dae-Youn;Kang, Hyun-Gu
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.362-367
    • /
    • 2016
  • The aim of the study was to evaluate ultrasonographic findings, affected age, hematology, blood chemistry and clinical signs according to open or closed cervix in 102 bitches presented for treatment of pyometra. The prevalence of pyometra according to breed was observed in Maltese 22.5%, Yorkshire Terrier 13.7% and Shih Tzu 12.7%. The mean age of dogs was $9.6{\pm}0.3years$, and open cervix pyometra was more prevalent than closed cervix pyometra. Clinical signs included anorexia, vaginal discharge, depression, polyuria/polydipsia, vomiting, and abdominal distension. The concentration of BUN and the activity of ALP in dogs with closed cervix pyometra were significantly higher than those in dogs with open cervix pyometra (p < 0.05). The white blood cell and neutrophils in dogs with closed cervix pyometra were significant higher than those in dogs with open cervix pyometra (p < 0.05). Ultrasonographic findings of the uterus with open or closed cervix pyometra showed variable patterns. The uterine wall was variable in appearance, from thick and irregular to smooth and thin. The uterine wall was thicker in open cervix pyometra than in closed cervix pyometra. The luminal cavity included smaller amount of anechoic fluid in open cervix pyometra than in closed cervix pyometra.

High-rate BCI spelling System using eye-closed EEG signals (닫힌 눈(eye-closed) EEG신호를 이용한 높은 비율BCI 맞춤법 시스템)

  • Nguyen, Trung-Hau;Yang, Da-lin;Kim, Jong-Jin;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • This study aims to develop an BCI speller utilizing eye-closed and double-blinking EEG based on asynchronous mechanism. The proposed system comprised a signal processing module and a graphical user interface (virtual keyboard-VK) with 26 English characters plus a special symbol. A detected "eye-closed" event induces the "select" command, whereas a "double-blinking" (DB) event functions the "undo" command. A three-class support vector machine (SVM) classifier involving EEG signal analysis of three groups of events ("eye-open"-idle state, "eye-closed", and "double -blinking") is proposed. The results showed that the proposed BCI could achieve an overall accuracy of 92.6% and a spelling rate of 5 letters/min on average. Overall, this study showed an improvement of accuracy and the spelling rate resulting from in the feasibility and reliability of implementing a real-world BCI speller.

  • PDF

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.