• Title/Summary/Keyword: Closed system and Open system

Search Result 514, Processing Time 0.036 seconds

Performance Analysis of Ground Heat Exchanger in Combined Well and Open-Closed Loops Geothermal (CWG) System (밀폐형과 개방형이 결합된 복합지열시스템의 지중열교환기 성능 분석)

  • Park, Youngyun;Song, Jae-Yong;Lee, Geun-Chun;Kim, Ki-Joon;Mok, Jong-Koo;Park, Yu-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.5
    • /
    • pp.23-29
    • /
    • 2017
  • This study was conducted to evaluate performance of geothermal heat exchanger (GHE) in the combined well and open-closed loops geothermal (CWG) systems. The CWG systems were designed to combine open loop geothermal heat pumps and closed loop geothermal heat pumps for high energy efficiency. GHE of the CWG systems could be installed at pumping wells for agricultural usage. To get optimal heat exchange capacity of GHE of the CWG systems, 4 GHEs with various materials and apertures were tested at laboratory scale. Polyethylene (PE) and stainless steel (STS) were selected as GHE materials. The maximum heat exchange capacity of GHEs were estimated to be in the range of 33.0~104 kcal/min. The heat exchange capacity of STS GHEs was 2.4~3.2 times higher than that of PE GHE. The optimal cross section area of GHE and flow rate of circulating water of GHE were estimated to be $2,500mm^2$ and 113 L/min, respectively. For more complicated GHE of the CWG systems, it is necessary to evaluate GHEs at various scales.

Development of a Groundwater Source Heat Pump in a Fractured Rock Aquifer (암반 대수층에서 개방형 지열 시스템의 개발 및 적용)

  • Shim, Byoung Ohan;Kim, Seong-Kyun;Choi, Hanna;Lee, Soo-Hyoung;Ha, Kyoochul;Kim, Yongchul
    • New & Renewable Energy
    • /
    • v.17 no.3
    • /
    • pp.32-41
    • /
    • 2021
  • A groundwater source heat pump (GWHP) was developed in this study by adapting a borehole heat exchanger with closed-loop and open-loop systems in a new building. In the pilot test building, the air-conditioning on the second floor was designed to employ a closed-loop system and that on the third floor had an open-loop system. The GWHP design is based on the feasibility of groundwater resources at the installation site. For the hydrogeological survey of the study site, pumping and injection tests were conducted, and the feasibility of GWHP installation was evaluated based on the air-conditioning load demand of the building. The site was found to be satisfactory for the design capacity of the thermal load and water quality. In addition, the effect of groundwater movement on the performance of the closed-loop system was tested under three different operational scenarios of groundwater pumping. The performance of the system was sustainable with groundwater flow but declined without appropriate groundwater flow. From long-term observations of the operation, the aquifer temperature change was less than 2℃ at the observation well and 5℃ at the injection well with respect to the initial groundwater temperature. This pilot study is expected to be of guidance for developing GWHPs at fractured rock aquifers.

Study on the Pre-treatment for Quantitative Analysis of Mercury in Paper Packaging Materials (지류포장재에서의 수은 정량분석을 위한 전처리 방법 연구)

  • Ko, Seung-Tae;Lee, Tai-Ju;Park, Ji-Hyun;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.5
    • /
    • pp.67-73
    • /
    • 2010
  • Paper packaging materials are essential in protection and transportation of commercial or industrial products. Raw materials for packaging paper production are mainly obtained from various grades of waste paper. For this reason, the recycled fibers from waste paper would probably have possibility of containing heavy metals. This study was focused on the development of optimum pre-treatment method for the quantitative analysis of mercury. The optimum pre-treatment for open digestion system were obtained at the treatment conditions of acid combination with $HNO_3/HCl/H_2O_2$ or $HNO_3/H_2SO_4$ at $80^{\circ}C$. The optimum pre-treatment conditions in closed digestion system were determinated by the acid combination with $HNO_3/HCl/H_2O_2/HF$ in microwave at 320 W for 20 min. The recovery rate in open digestion system was 85~94% and in closed digestion system was indicated as about 100%. Therefore, the closed system is superior than the open system in pre-treatment method for the quantitative analysis of mercury, and the detected mercury contents in the sample of KOCC, AOCC and kraft sack paper were measured below 1 ppm.

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

Postural stability test of double leg support and single limb stance (양발로 선 자세와 한발로 선 자세의 자세안정도 검사)

  • Kwon, Mi-Ji
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.4
    • /
    • pp.851-860
    • /
    • 1998
  • The purpose of this study was to quantitatively observe changes in postural stability of double leg support and single limb stance. Thirty-six healthy subjects participated in the study. Postural stability were examined using Dynamic Balance System. Each trial was 25 sec in duration. Each of 6 conditions{double leg support and single limb stance ; eyes open in stable platform, eyes closed in stable platform, eyes open in dynamic platform) evaluated effect of visual, vestibular, proprioceptive system. Center of balance found for displacement to the left along the X axis in double leg support and to the forward on left toe in single limb stance. Sway index was the lowest in double leg support with eyes open in stable platform and the higher in single limb stance with eyes closed in stance platform. We believe that reliable and valid measures should be used to determine the contributing factors of our client's postural problems so that we can design the most effective treatment possible.

  • PDF

LIGHT-REGULATED LEAF MOVEMENT AND SIGNAL TRANSDUCTION IN NYCTINASTIC PLANTS

  • Kim, Hak-Yong
    • Journal of Photoscience
    • /
    • v.4 no.1
    • /
    • pp.23-30
    • /
    • 1997
  • Leaf movements in nyctinastic plants are produced by changes in the turgor of extensor and flexor cells, collectively called motor cells, in opposing regions of the leaf movement organ, the pulvinus. In Samanea saman, a tropical tree of the legume family, extensor cells shrink and flexor cells swell to bend the pulvinus and fold the leaf at night, whereas extensor cells swell and flexor cells shrink to straighten the pulvinus and extend the leaf in the daytime. These changes are caused by ion fluxes primarily of potassium and chloride, across the plasma membrane of the motor cells. These ion fluxes are regulated by exogenous light signals and an endogenous biolgical clock. Inward-directed K$^+$ channels are closed in extensor and open in flexor cells in the dark period, while these channels are open in extensor and closed in flexor cells in the light period. Blue light opens the closed K$^+$ channels in extensor and closes the open them in flexor cells during darkness. Illumination of red light followed by darkness induces to open the closed K$^+$ channels in flexor and to close the open K$^+$ channels in extensor cells in the light. The dynamics of K$^+$ channels in motor cells that are controlled by light signals are consistent with the behavior of the pulvini in intact plants. Therefore, these cell types are an attractive model system to elucidate regulations of ion transports and their signal transduction pathways in plants. This review is focused on light-controlled ion movements and regulatory mechanisms involved in phosphoinositide signaling in leaf movements in nyctinastic plants.

  • PDF

An Economic Design of a k-out-of-n System

  • Yun, Won-Young;Kim, Gue-Rae;Gopi Chattopadhyay
    • International Journal of Reliability and Applications
    • /
    • v.4 no.2
    • /
    • pp.51-56
    • /
    • 2003
  • A k-out-of-n system with n identical and independent components is considered in which the components takes two types of function: 0 (open-circuit) or 1 (closed) on command (e.g. electromagnetic relays and solid state switches). Components are subject to two types of failure on command: failure to close or failure to open. In our k-out-of-n system, failure of (n-k)+1 or more components to close causes to the close failure of the system, or failure of k or more components to open causes the open failure of the system. The long-run average cost rate is obtained. We find the optimal k minimizing the long run average cost rate for given n. A numerical example is presented.

  • PDF

Identification of the process in closed-loop control system

  • Oura, Kunihiko;Akizuki, Kageo;Hanazaki, Izumi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.140-145
    • /
    • 1994
  • In this paper, we consider a problem to estimate process parameters using input-output data collected from the process operating in closed-loop control system. When orders and delay-time of the process are known correctly, under some conditions of identifying experiments, it is reported that accurate identification results can be obtained by applying prediction error method. To get accurate estimates, it is necessary to know orders and delay-time of the process. It is difficult to determine them in closed-loop identification, because ill-condition for identification are easily caused by selection of unsuitable order or delay time. Furthermore, the procedures to select orders and delay-time in open-loop identification aren't always available in closed-loop identification. The purpose of this paper is to determine a delay-time under suitable assumption that order of the process are known as the first step.

  • PDF

Design of the Zero Location for Minimizing the Peak Overshoot of Second-Order Discrete Systems (이차 이산 시스템의 Peak Overshoot을 최소화하기 위한 영점의 위치 설계)

  • Lee, Jae-Seok;Chung Tae-Sang
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.11
    • /
    • pp.483-493
    • /
    • 2002
  • The damping ratio ${\xi}$ of the unit-step response of a second-order discrete system is a function of only the location of the closed-loop poles and is not directly related to the location of the system zero. However, the peak overshoot of the response is the function of both the damping ratio ${\xi}$ and an angle ${\alpha}$, which is the phasor angle of the damped sinusoidal response and is determined by the relative location of the zero with respect to the closed-loop poles. Therefore, if the zero and the open-loop poles are relatively adjusted, through pole-zero cancellation, to maintain the desired (or designed) closed-loop poles, the damping ratio ${\xi}$ will also be maintained, while the angle ${\alpha}$ changes. Accordingly, when the closed-loop system poles are fixed, the peak overshoot is considered as a function of the angle ${\alpha}$ or the system zero location. In this paper the effects of the relative location of the zero on the system performance of a second-order discrete system is studied, and a design method of digital compensator which achieves a minimum peak overshoot while maintaining the desired system mode and the damping ratio of the unit step response is presented.