• 제목/요약/키워드: Closed circuit

검색결과 340건 처리시간 0.027초

전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구 (Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

밀폐박스 상태의 가상 라우드스피커 매개변수 규명법 및 개선된 밀폐박스 모델링 (Parameters Estimation for Pseudo Loudspeaker attached to Closed-Box and Enhanced Closed-Box Modeling)

  • 박석태
    • 한국소음진동공학회논문집
    • /
    • 제17권10호
    • /
    • pp.983-992
    • /
    • 2007
  • It was proposed to identify Thiele Small Parameters for loudspeaker attached to closed-box using known dynamic mass of moving parts. Also, enhanced PSPICE circuit model for closed-box loudspeaker system was proposed to more accurately simulate real closed-box loudspeaker system. Frequency dependent parameters were used to model voice coil inductor. Acoustic pressure response curves and electrical impedance curves were simulated and investigated by PSPICE circuit model according to compensation filter's parameters. Finally, proposed method is expected to be utilized for identification of pseudo Thiele Small parameters of microspeaker.

Stability analysis of transversely isotropic laminated Mindlin plates with piezoelectric layers using a Levy-type solution

  • Ghasemabadian, M.A.;Saidi, A.R.
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.675-693
    • /
    • 2017
  • In this paper, based on the first-order shear deformation plate theory, buckling analysis of piezoelectric coupled transversely isotropic rectangular plates is investigated. By assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for buckling analysis of plate with surface bonded piezoelectric layers are established. The Maxwell's equation and all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. The analytical solution is obtained for Levy type of boundary conditions. The accurate buckling load of laminated plate is presented for both open and closed circuit conditions. From the numerical results it is found that, the critical buckling load for open circuit is more than that of closed circuit in all boundary and loading conditions. Furthermore, the critical buckling loads and the buckling mode number increase by increasing the thickness of piezoelectric layers for both open and closed circuit conditions.

Investigation of buckling behavior of functionally graded piezoelectric (FGP) rectangular plates under open and closed circuit conditions

  • Ghasemabadian, M.A.;Kadkhodayan, M.
    • Structural Engineering and Mechanics
    • /
    • 제60권2호
    • /
    • pp.271-299
    • /
    • 2016
  • In this article, based on the higher-order shear deformation plate theory, buckling analysis of a rectangular plate made of functionally graded piezoelectric materials and its effective parameters are investigated. Assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for the buckling analysis of an FGP rectangular plate are established. In addition to the Maxwell equation, all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. Considering double sine solution (Navier solution) for displacement field and electric potential, an analytical solution is obtained for full simply supported boundary conditions. The accurate buckling load of FGP plate is presented for both open and closed circuit conditions. It is found that the critical buckling load for open circuit is more than that of closed circuit in all loading conditions. Furthermore, it is observed that the influence of dielectric constants on the critical buckling load is more than those of others.

Improved Modification of the Closed-Loop-Controlled AC-AC Resonant Converter for Induction Heating

  • Dhandapani, Kirubakaran;Sathi, Rama Reddy
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.298-303
    • /
    • 2009
  • A single-switch parallel resonant converter for induction heating is implemented. The circuit consists of an input LC-filter, a bridge rectifier, and a controlled power switch. The switch operates in soft commutation mode and serves as a high frequency generator. The output power is controlled via the switching frequency. A steady state analysis of the converter operation is presented. A closed-loop circuit model is also presented, and the experimental results are compared with the simulation results.

  • PDF

산소 발생 폐쇄식 SCBA를 위한 이산화칼륨과 이산화탄소의 반응 정량화 (Quantification of Oxygen Production from Carbon Dioxide Using Potassium Superoxide for Oxygen Generating Closed-Circuit SCBA)

  • 양원호;송영웅
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.236-240
    • /
    • 2010
  • This study demonstrates the use of a chemical containing potassium superoxide (KO2) to convert carbon dioxide (CO$_2$) in air to oxygen (O$_2$). A oxygen generating closed-circuit SCBA (self contained breathing apparatus) removes carbon dioxide by a chemical reaction with potassium dioxide that consumes the carbon dioxide and produces oxygen. Considering the disasters, there is a need to develop strategies to enable the introduction of self-contained self rescuers (SCSR). The potassium superoxide reacts with the wears breath to produce oxygen and absorb carbon dioxide. If the respiration rate of a person is 5 MET (metabolic equivalent), to say 30 L/min, at disaster such as fire, mass of potassium superoxide was evaluated as 33.3 g with yield and safety factor. Four researchers tested on a laboratory treadmill breathing through SCSRs in a closed circuit, it appears useable for 9 minutes.

멀티패스 밀폐식 냉각탑의 성능특성에 대한 수치적 연구 (A Numerical Study on Performance Characteristics of a Closed Circuit Cooling Tower with Multi Paths)

  • 김은필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.528-533
    • /
    • 2008
  • A closed circuit cooling tower having high temperature of cooling water and small water flow rate is investigated. To study the characteristics of the heat transfer of heat exchanges in a cooling tower with multi paths a numerical method is used. The results show that the staggered tube arrangements in a bank show better performance than aligned ones for temperature variation with various outer diameters of tube bundles. In case of one pass, the 15.88 mm tube case shows about 9% better performance than the 25.4 mm tube case. In two paths, the tube outside diameter of 15.88 mm show about 14.4% better results than the 25.4 mm diameter case.

Adaptive Control of Multiplexed Closed Circuit Anesthesia

  • Jee, Gyu-In;Roy, Rob
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.79-81
    • /
    • 1992
  • This paper describes the design of an adaptive closed circuit anesthesia controller based on a multiplexed mass spectrometer system. The controller deals with measurement deterioration caused by measurement delay and rise time through a tong catheter as well as long sampling times due to the multiplexed measurements. Measurement data is extrapolated between sampling periods to increase the estimation convergence rate. A multiple-step-ahead predictive control algorithm is used to calculate intermediatc control inputs between sampling intervals. Simulations are used to validate the designed controller.

  • PDF

배선용 차단기의 전자 반발력에 관한 연구 (Analysis of Electromagnetic Repulse Forces of MCCB)

  • 김길수;임기조;강성화;조현길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.593-596
    • /
    • 2001
  • It is necessary for calculation of repulsion forces acting on the closed electric contacts flowing over-current, e.g. inrush current and overload currents, to do optimum design of switching devices. In this paper, the farces and flux densities generated by currents at the contact point when circuit breakers are in closed state are obtained by using 3D finite element methode. To be convinced of the results, we measure electrogmanetic repulsion forces on contacts by measuring voltage between opened contacts in MCCB.

  • PDF

전도 수문용 유압장치의 에너지 효율에 관한 연구 (Study for the Energy Efficiency of Hydraulic System of Turnover-Type Sluice Gate)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1225-1230
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the hydrauic system. The hydraulic system may be a open circuit type or a closed circuit type. The open circuit type hydraulic system is composed of a uni-directional pump, a directional control valve, pilot operated check valves, flow control valves, single-rod cylinders. The closed circuit type hydraulic system is composed of a bi-directional pump, pilot operated check valves, check valves, a counter balance valve, single-rod cylinders. The energy efficiencies of two hydraulic systems for the turnover-type sluice gate are compared here.

  • PDF