• Title/Summary/Keyword: Closed Loop Circuit

Search Result 92, Processing Time 0.041 seconds

A study on the implementation of closed-loop system using the stepper motor back-EMF (스텝모터 역기전력을 이용한 폐루프 시스템 구현에 관한 연구)

  • Im, Sungbeen;Jeong, Sanghwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.3
    • /
    • pp.363-370
    • /
    • 2015
  • In this paper, the control technique of the stepping motor using back electromotive force(B-EMF) without encoder is investigated. The stepping motor generally uses the rotary encoder to detect the rotor position. Since this method increases the cost and the motor configuration size, the new closed-loop control method applied for the B-EMF was implemented by using current detect circuit, AD-converter, and micro controller unit(MCU). The control loop of stepping motor became very simplified. The current change of stepping motor measured by the amplifier was measured and analyzed, when the missing step is occurred. Based on the data from current feedback, position errors were compensated and confirmed by using AD-converter.

A Study on Position of Six-Degrees-of-Freedom of vibration Model and Orientation Decision by Adaptive Control Method (6자유도 진동모댈의 위치 및 자세결정을 위한 적응제어기법의 적용에 관한 연구)

  • Kim, J.Y.;Song, S.K.;Han, J.H.;Oh, Y.H.;Cho, S.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.94-101
    • /
    • 1994
  • About vibration model of Six-degrees-of-freedom(DOF), in mass load, examined results for knowing dynamic interference and response variation is as follows; In case of putting mass load upon the object, experimented results on two-degrees-of-freedom of the translation-1 direction and the rotation-1 direction at open-loop-control system, about 0.19 arcsed in input of the translation-$0.1{\mu}m$ and $0.022{\mu}m$ on input of the rotation-0.5 arcsec, the justicse of motion equation is acknowledged as confirming the appearance of the interference-$0.022{\mu}m$. In establishing calculation of transformation matrix by using analogue circuit, as simulating results that used incomplete differentiation, interference is $1.7{\times}10^{-3}$ arcsec on input of the translation-$0.1{\mu}m$ and $1.4{\times}10^{4}{\mu}m$ on input of the rotation-0.5 arcsec in open-loop-control system. Also it is $4.2{\times}10^{-4}$ arcsec on input of the translation-$0.1{\mu}m$ and $5.6{\times}10^{-5}{\mu}m$ on input of the rotation-0.5 arcesc in closed-loop-control system. As closed-loop-control system is better than open-loop-control system, equivalent accordance is confirmed on original response. Finally, fundamental validity of this theory is acknowledged.

  • PDF

Torque Control Scheme of Switched Reluctance Motor using Neural Network (신경회로망을 이용한 SRM의 토오크 제어)

  • 정연석;이장선;김윤호
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.171-174
    • /
    • 1999
  • The torque of SRM is developed by phase currents and inductance variation. Phase currents and inductance variation. Phase current is often the controlled variable in electrical motor drives, so it seems natural to use closed loop current controllers. However, the highly nonlinear nature of switched reluctance motors makes optimisation of closed loop current controlled difficult because of saturation effect in magnetic circuit. Therefore, torque generation region is nonlinearly varied according to phase current and rotor position. This paper describes the torque control scheme with neural network that can control varied with load torque. The torque control is simulated by PSIM.

  • PDF

Closed loop type MCV(Main Control Valve) for Hydraulic Excavator (유압 굴삭기용 폐루프 타입 MCV(Main Control Valve))

  • Lim T.H.;Lee H.S.;Yang S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.864-870
    • /
    • 2005
  • Hydraulic excavators have been popular devices in construction field because of its multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of nonlinear opening characteristics and dead zone of main control valve, oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and whole circuit are expressed graphically. Parameters and nonlinear characteristics are inputted in text style. From the simulation results, fixed spring stiffness of MCV can't satisfy accuracy of spool displacement under whole P-Q diagrams. Closed loop type MCV containing proportional gain is proposed in this paper that can reduce displacement error. The ability of closed loop MCV is verified through comparing with normal type MCV using AMESim simulator. The simulator can be used to forecastexcavator behavior when new components, new mechanical attachments, hydraulic circuit changes, and new control algorithm are applied. The simulator could be a kind of development platform for various new excavators.

  • PDF

Analysis of force between linear moving Halbach array and a closed loop (직선운동하는 Halbach 배열 가동자와 폐루프 코일 사이의 작용력 해석)

  • Jang, S.M.;Cha, S.D.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.90-92
    • /
    • 2001
  • The lift and drag forces on various magnet moving with a velocity is developed above a closed loop coil. These forces are affect by resistance and inductance of circuit, velocity of magnet. To obtain strong magnetic flux density, the magnet is replaced by Halbach array. This paper presents analysis of force between linear motion Halbach array and a closed loop having the constant resistance and inductance as a various speed.

  • PDF

A Study on the Parallel Operation and Control Loop Design of ZVT-Full Bridge DC/DC Converter (ZVT 풀 브리지 DC/DC 컨버터의 병렬 운전 및 제어기 설계에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Yoon, Suk-Ho;Chang, Sung-Won;Lee, Kyu-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.324-328
    • /
    • 2001
  • This paper presents parallel operation and control loop design of ZVT(Zero Voltage Transition) Full Bridge DC/DC Converter. At parallel operation of ZVT Full Bridge Converter, dynamic current shared inductor devides the same current of unit converter and ZVT circuit and aids to high efficiency in the system. Base on the modeling of ZVT. Full Bridge Converter, the control loop is designed using a simple two-pole, one-zero compensation circuit. To show the validity of the design procedures, the small signal analysis of the closed loop system and open loop system is carried out and the superiority of the dynamic characteristics is verified through the experiment with a 2kW, 50kHz prototype converter.

  • PDF

A Fast RSSI using Novel Logarithmic Gain Amplifiers for Wireless Communication

  • Lee, Sung-Ho;Song, Yong-Hoon;Nam, Sang-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.22-28
    • /
    • 2009
  • This paper presents a fast received signal strength indicator (RSSI) circuit for wireless communication application. The proposed circuit is developed using power detectors and an analog-to-digital converter to achieve a fast settling time. The power detector is consisted of a novel logarithmic variable gain amplifier (VGA), a peak detector, and a comparator in a closed loop. The VGA achieved a wide logarithmic gain range in a closed loop form for stable operation. For the peak detector, a fast settling time and small ripple are obtained using the orthogonal characteristics of quadrature signals. In $0.18-{\mu}m$ CMOS process, the RSSI value settles down in $20{\mu}s$ with power consumption of 20 mW, and the maximum ripple of the RSSI is 30 mV. The proposed RSSI circuit is fabricated with a personal handy-phone system transceiver. The active area is $0.8{\times}0.2\;mm^2$.

Development of an Electric Circuit Transient Analogy Model in a Vertical Closed Loop Ground Heat Exchanger (수직밀폐형 지중열교환기의 회로 과도해석 상사모델 개발)

  • Kim, Won-Uk;Park, Hong-Hee;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • Several numerical or analytical models have been proposed to analyze the thermal response of vertical ground heat exchangers (GHEX). However, most models are valid only after several hours of operation since they neglect the heat capacity of the borehole. Recently, the short time response of the GHEX became important in system simulation to improve efficiency. In this paper, a simple new method to evaluate the short time response of the GHEX by using an analogy model of electric circuit transient analysis was presented. The new transient heat exchanger model adopting the concept of thermal capacitance of the borehole as well as the steady-state thermal resistance showed the transient thermal resistance of the borehole. The model was validated by in-situ thermal response test and then compared with the DST model of the TRNSYS program.

The Design of Frequency Synthesizer by Open and Closed Loop Alternation Method (개폐루프 교대방식에 의한 주파수합성기의 설계)

  • 김익상;한영열
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.2
    • /
    • pp.124-132
    • /
    • 1987
  • In this paper, a new Open and Closed Loop Alternation(OCLA) frequency synthesizer is developed to eliminate a frequency error occurring in the transition state of a frequency hopping. This frequency synthesizer consists of a phase comparator(PC), two low pass filters(LPF), two voltage controlled oscillators(VCO), switching elements, a programmable divider and frequency hopping controller, and the stabilized output frequency can be obtained by switching performance. In addigion, it can be found that the characteristic of its circuit construction makes it easy to attach an external circuitry to the open loop.

  • PDF

Optimum Parameter Determination of PLL Used in Timing Clock Recovery Circuit (타이밍 클릭 복원 회로에 사용된 PLL의 최적 파라미터 결정)

  • Ryu, Heunggyoon;ANN, Souguil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.3
    • /
    • pp.376-380
    • /
    • 1987
  • The closed-loop transfer function of 2-nd order PLL (phase-looked loop)of which loop filter has active-lag 1-st order is found. Considering the three criteria of system performance: the transient response time of the circuit, noise bandwidth by the linear analysis and stability which uses root-locus method, the optimum value of damping factor is 1.0 and the natural frequency which depends upon the signal frequency can be determined after consideration of the trade-off relationship between the transient response time and the noise bandwidth.

  • PDF