• Title/Summary/Keyword: Closed Distance

Search Result 269, Processing Time 0.023 seconds

HD-CCTV System Design with Extended Transmission Distance using Digital Modulation (디지털 변조를 적용하여 전송거리가 확장된 HD-CCTV 시스템 설계)

  • Hong, Sungwon;Han, Dong Seog
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.986-994
    • /
    • 2016
  • In this paper, a digital closed-circuit television (CCTV) transmission system called the extended reach high definition serial digital interface (ER-SDI) is proposed to increase the transmission distance while preserving the quality using digital modulation. The current standard of HD-serial digital interface (HD-SDI) has the maximum transmission distance of 200 m. Recently, one system which transforms the digital signal to an analog signal and modulates color signal to extend the transmission distance is proposed. Another system which uses IP network is also proposed. However, the former system has a disadvantage of video quality and the latter system has high latency. The proposed ER-SDI is designed to extend the transmission distance of 518 m by adopting multilevel constellations and a channel code for a data rate of 1.485 Gbps. The maximum transmission distance of the proposed system is calculated using the specification of HD-SDI and the experiment result under coaxial cable environment.

Limit Analysis of the Distance between DU and RU in 4G FDD Mobile Communication Systems (FDD 방식의 4G 이동통신 기지국에서 DU와 RU간 한계거리 분석)

  • Kim, Sung-Man
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.135-139
    • /
    • 2012
  • A majority of 4G Mobile communication manufacturers have launched separated-type base stations composed of DU (digital unit) and RU (ratio unit). DUs are usually installed in the central office, while RUs with antennas are installed on the top of building or pole. Therefore, the allowable distance between DU and RU is very important for cell planning. In this paper, we analyze the allowable distance between DU and RU induced by closed-loop MIMO (mulitple input multiple output) technology in 4G FDD (frequency division duplexing) mobile communication systems. In conclusion, the distance limit between DU and RU is dependent on the frequency of the wireless communication, and the allowable distance is about 11 km when assuming the operating frequency is 2 GHz.

An Experimental Study on the Explosion of Hydrogen Tank for Fuel-Cell Electric Vehicle in Semi-Closed Space (반밀폐공간에서 발생되는 차량용 수소연료탱크 폭발 실험)

  • Park, Jinouk;Yoo, Yongho;Kim, Hwiseong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.4
    • /
    • pp.73-80
    • /
    • 2021
  • Recently, Korea has established a plan for the supply of hydrogen vehicles and is promoting the expansion of the supply. Risk factors for hydrogen vehicles are hydrogen leakage, jet fire, and explosion. Therefore Safety measures are necessary for this hazard. In addition, risks in semi-closed spaces such as tunnels, underground roads, and underground parking lots should be analyzed. In this study, an explosion experiment was conducted on a hydrogen tank used in a hydrogen vehicle to analyze the risk of a hydrogen vehicle explosion accident that may occur in a semi-closed space. As results, the effect on the structure and the human body was analyzed using the overpressure and impulse values for each distance generated during the explosion.

A Location-Routing Problem for Logistics Network Integrating Forward and Reverse Flow (역물류를 고려한 통합물류망에서의 입지:경로문제)

  • Na, Ho-Young;Lee, Sang-Heon
    • IE interfaces
    • /
    • v.22 no.2
    • /
    • pp.153-164
    • /
    • 2009
  • An effective management for reverse flows of products such as reuse, repair and disposal, has become an important issue for every aspect of business. In this paper, we study the Location-Routing Problem (LRP) in the multi-stage closed-loop supply chain network. The closed-loop supply chain in this study integrated both forward and reverse flows. In forward flow, a factory, Distribution Center (DC) and retailer are considered as usual. Additionally in reverse flow, we consider the Central Returns collection Center (CRC) and disposal facility. We propose a mixed integer programming model for the design of closed-loop supply chain integrating both forward and reverse flows. Since the LRP belongs to an NP-hard problem, we suggest a heuristic algorithm based on genetic algorithm. For some test problems, we found the optimal locations and routes by changing the numbers of retailers and facility candidates. Furthermore, we compare the efficiencies between open-loop and closed-loop supply chain networks. The results show that the closed-loop design is better than the open one in respect to the total routing distance and cost. This phenomenon enlarges the cut down effect on cost as an experimental space become larger.

The Usefulness of Clinical Balance Tests in Elderly : Correlation of Balance Evaluation using by Forceplate (노인에서 임상적 균형평가 지수들의 유용성 : 힘판을 이용한 균형평가와의 상관관계)

  • Woo, Young-Keun;Hwang, Su-Jin;Lee, Woo-Hyung
    • PNF and Movement
    • /
    • v.8 no.1
    • /
    • pp.67-77
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the usefulness of clinical balance tests through the correlation of balance evaluation using by forceplate in elderly. Methods : Thirty nine healthy elderly subjects (14 males, 25 females) participated in the study. The subjects were evaluated with clinical balance tests [(Berg balance scale (BBS), Functional reach test (FRT), Tinetti's performance oriented mobility assessment (POMA), and one leg standing (OLS)]. Static balance evaluation was assessed by using forceplate. Center of pressure (COP) parameters were obtained using it as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened and closed, (2) uncomfortable standing with eyes opened and closed. After static balance evaluation tested, dynamic balance evaluation was assessed. COP parameters were error distance and area during sine curve trace. COP parameters were movement time, error distance, and maintained time in the circle during COP movement task. Results : Clinical balance tests showed statistically significant correlation between static and dynamic balance evaluations. Among the clinical balance tests, the BBS, POMA, and OLS showed significant correlation with to assess the balance ability of elderly in clinical setting both evaluations. Conclusion : Clinical balance tests can be recommended in clinical setting because of low costs and simplicity.

  • PDF

Numerical Taxonomy of Eight Speices of the Bithyniidae ( Gastropoda : Prosobranchia) (쇠우렁이과 ( Birthyniidae ) 패류 8종에 대한 수리분류학적 연구)

  • 김재진
    • The Korean Journal of Malacology
    • /
    • v.10 no.1
    • /
    • pp.19-26
    • /
    • 1994
  • Eight species of the family Bithyniidae, Bithynia tentaculata, B. leachi, B. siaminsis, B manchourica, B misella, B. kiusiuensis, Gabbia australis and a Bithynia wp. collected from Nepal, were studied for their relationship between species. Total 20 characters were employed for the principal component analysis(PCA) and taxonomic distance. G. misella and B. kiusiuensis were closely related and similar to G. australis. B. manchourica, B. tentaculata and B. siamensis relatively closed group, and taxonomic distance of B. leachi was far from the other species.

  • PDF

The Spatially Closed Universe

  • Park, Chan-Gyung
    • Journal of the Korean earth science society
    • /
    • v.40 no.4
    • /
    • pp.353-381
    • /
    • 2019
  • The general world model for homogeneous and isotropic universe has been proposed. For this purpose, we introduce a global and fiducial system of reference (world reference frame) constructed on a (4+1)-dimensional space-time, and assume that the universe is spatially a 3-dimensional hypersurface embedded in the 4-dimensional space. The simultaneity for the entire universe has been specified by the global time coordinate. We define the line element as the separation between two neighboring events on the expanding universe that are distinct in space and time, as viewed in the world reference frame. The information that determines the kinematics of the geometry of the universe such as size and expansion rate has been included in the new metric. The Einstein's field equations with the new metric imply that closed, flat, and open universes are filled with positive, zero, and negative energy, respectively. The curvature of the universe is determined by the sign of mean energy density. We have demonstrated that the flat universe is empty and stationary, equivalent to the Minkowski space-time, and that the universe with positive energy density is always spatially closed and finite. In the closed universe, the proper time of a comoving observer does not elapse uniformly as judged in the world reference frame, in which both cosmic expansion and time-varying light speeds cannot exceed the limiting speed of the special relativity. We have also reconstructed cosmic evolution histories of the closed world models that are consistent with recent astronomical observations, and derived useful formulas such as energy-momentum relation of particles, redshift, total energy in the universe, cosmic distance and time scales, and so forth. The notable feature of the spatially closed universe is that the universe started from a non-singular point in the sense that physical quantities have finite values at the initial time as judged in the world reference frame. It has also been shown that the inflation with positive acceleration at the earliest epoch is improbable.

RADIOGRAPHIC ANALYSIS OF THE TEMPOROMANDIBULAR JOINT BY THE STANDARDIZED PROJECTION TECHNIQUE (악관절규격촬영법에 의한 과두위의 분석 연구)

  • Choe Han Up
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.13 no.1
    • /
    • pp.7-15
    • /
    • 1983
  • The purpose of this study was to investigate the radiographic images of the condylar head in clinically normal subjects and the TMJ patients using standardized projection technique. 45 subjects who have not clinical evidence of TMJ problems and 96 patients who have the clinical evidence of TMJ problems were evaluated, but the patients who had fracture, trauma and tumor on TMJ area were discluded in this study. For the evaluation of radiographic images, the author has observed the condylar head positions in closed mouth and 2.54㎝ open mouth position taken by the standardized transcranial oblique lateral projection technique. The results were as follows: 1. In closed mouth position, the crest of condylar head took relatively posterior position to the deepest point of the glenoid fossa in 8.9 % of the normals and in 26.6% of TMJ patients. 2. In 2.54㎝ open mouth position, condylar head took relatively posterior position to the articular eminence in 2.2% of TMJ patients and 39.6% of the normals. 3. In open mouth position, the horizontal distance from the deepest point of the glenoid fossa to the condyla head was 13.96㎜ in the normals and 10.68㎜ in TMJ patients. 4. The distance of true movement of condyalr head was 13.49㎜ in the normals and l0.27㎜ in TMJ patients. 5. The deviation of mandible in TMJ patients was slightly greater than that of the normals.

  • PDF

A study on evaluation method of NIDS datasets in closed military network (군 폐쇄망 환경에서의 모의 네트워크 데이터 셋 평가 방법 연구)

  • Park, Yong-bin;Shin, Sung-uk;Lee, In-sup
    • Journal of Internet Computing and Services
    • /
    • v.21 no.2
    • /
    • pp.121-130
    • /
    • 2020
  • This paper suggests evaluating the military closed network data as an image which is generated by Generative Adversarial Network (GAN), applying an image evaluation method such as the InceptionV3 model-based Inception Score (IS) and Frechet Inception Distance (FID). We employed the famous image classification models instead of the InceptionV3, added layers to those models, and converted the network data to an image in diverse ways. Experimental results show that the Densenet121 model with one added Dense Layer achieves the best performance in data converted using the arctangent algorithm and 8 * 8 size of the image.

Closed-Form Green's Function for the Analysis of Microstrip Structure (마이크로스트립 구조 해석을 위한 Closed-Form 그린 함수)

  • Yang, Seung-Woo;Kim, Sung-Jin;Kim, Gun-Woo;Lee, Taek-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.281-293
    • /
    • 2008
  • In the layered medium, the Sommerfeld integral must be evaluated to calculate a space domain Green's function. The real axis integration method provides stable and accurate results over wide ranges of the observation distance and the singnal frequency. But this method has the in efficiency of approximation when the field point z is changed. Also, as the amplitude of z increases, the change of the spectral domain function is more rapidly. Therefore, the approximation is difficult when z becomes larger. In this paper, we propose a method to calculate an accurate closed-form Green's function for microstrip structure by using the closed-loop integration path.