• Title/Summary/Keyword: Close up

Search Result 1,259, Processing Time 0.025 seconds

Necessity and adequacy of near-source factors for seismically isolated buildings

  • Saifullah, Muhammad Khalid;Alhan, Cenk
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.91-108
    • /
    • 2017
  • Superstructures and isolation systems of seismically isolated buildings located close to active faults may observe increased seismic demands resulting from long-period and high-amplitude velocity and displacement pulses existent in near-fault ground motions as their fundamental periods may be close to or coincident with these near-fault pulse periods. In order to take these effects into account, the 1997 Uniform Building Code (UBC97) has specified near-source factors that scale up the design spectrum depending on the closest distance to the fault, the soil type at the site, and the properties of the seismic source. Although UBC97 has been superseded by the 2015 International Building Code in the U.S.A., UBC97 near-source factors are still frequently referred in the design of seismically isolated buildings around the world. Therefore it is deemed necessary and thus set as the aim of this study to assess the necessity and the adequacy of near-source factors for seismically isolated buildings. Benchmark buildings of different heights with isolation systems of different properties are used in comparing seismic responses obtained via time history analyses using a large number of historical earthquakes with those obtained from spectral analyses using the amplified spectrums established through UBC97 near-source factors. Results show that near-source factors are necessary but inadequate for superstructure responses and somewhat unconservative for base displacement response.

Dietary Reference Intakes for Protein: Protein Requirement and Estimation Method, AMDR (Amount of Macronutrient Distribution Range), for Protein (단백질 섭취기준: 단백질 필요량과 추정 방법 및 단백질에너지 적정비율)

  • Chang, Soon-Ok
    • Journal of Nutrition and Health
    • /
    • v.44 no.4
    • /
    • pp.338-343
    • /
    • 2011
  • This study assessed the current EAR, RDA, and AMDR for protein, which were set in 2005 and revised in 2010 as the DRIs for Koreans. A classical approach to establish the EAR for protein has been the nitrogen balance method. This method has practical limitations and problems in statistical analysis by giving over estimations of nitrogen balance. Thus, the present EAR for protein might be lower than the true requirement. Recent reevaluations of nitrogen balance studies by bilinear regression analysis and the IAAO method have indicated that the EAR of 0.66 g/kg bw/d should be increased by 39% to give 0.92 g/kg bw/d. The AMDR for protein in the Korean DRIs was set at 7-10%, which covers almost the entire population's protein intake. Since the 5th percentile of Korean protein intake is close to 10% of energy and due to the beneficial effects of protein beyond the maintenance of nitrogen equilibrium, the lower range of 7% needs to be increased up to 10%. For practical meal arrangement, 15% of energy as protein, which is close to the average protein intake of Koreans, seems to be proper, although the value is almost two times the EAR.

Plasma Flows and Bubble Properties Associated with the Magnetic Dipolarization in Space Close to Geosynchronous Orbit

  • Lee, Ji-Hee;Lee, Dae-Young;Park, Mi-Young;Lee, Eun-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.95-100
    • /
    • 2013
  • In this paper we examine a total of 16 dipolarization events that were observed by THEMIS spacecraft in space close to geosynchronous orbit, r < ${\sim}7\;R_E$. For the identified events, we examine the characteristics of the plasma flows and associated bubbles as defined based on $pV^{5/3}$, where p is the plasma pressure and V the volume of unit magnetic flux. First, we find that the flow speed in the near-geosynchronous region is very low, mostly within a few tens of km/s, except for a very few events for which the flow can rise up to ~200 km/s but only very near the dipolarization onset time. Second, the bubble parameter, $pV^{5/3}$, decreases by a much smaller factor after the dipolarization onset than for the events in the farther out tail region. We suggest that the magnetic dipolarization in the near-geosynchronous region generates or is associated with only very weak plasma bubbles. Such bubbles in the near-geosynchronous region would penetrate earthward only by a small distance before they stop at an equilibrium position or drift around the Earth.

Application of Close-to Nature Revetment Techniques Adapted to Low Flow Channel & Monitoring of Vegetation Restoration - Case Study for Hakyoul in the Yangjaech'on - (도시하천에서 자연형 저수로 호안공법의 적용과 식생복원 모니터링 - 서울시 양재천의 학여울 구간을 사례지역으로 -)

  • 최정권
    • Korean Journal of Environment and Ecology
    • /
    • v.11 no.2
    • /
    • pp.210-213
    • /
    • 1997
  • This study for development of close-to nature revetment techniques is conducted to rehabilitate disturbed stream ecosystem. For this objective, the experimental reach as on-site dimonstrated research was set up in Hakyoul, the Yangjaech'on from Oct. 1995 to Nov. 1996. Special emphasis on the developing process of the design of revetments was given to geomorphic character of 3 types of low flow channel bank: point bar, attack point and shallow bay. Each revetment was developed with the consideration on revegetation of emergent plants. And designed techniques were applied to the experimental reach, and were evaluated with monitoring for 1 year. As a result of the process, the experiment suggested ecological alternatives to enhance technical feasibility and to replace the conventional river-work.

  • PDF

CLOSE ENCOUNTERS BETWEEN A NEUTRON STAR AND A MAIN-SEQUENCE STAR

  • LEE HYUNG MOK;KIM SUNG S.;KANG HYESUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.1
    • /
    • pp.19-30
    • /
    • 1996
  • We have examined consequences of strong tidal encounters between a neutron star and a normal star using SPH as a possible formation mechanism of isolated recycled pulsars in globular clusters. We have made a number of SPH simulations for close encounters between a main-sequence star of mass ranging from 0.2 to 0.7 $M_\bigodot$ represented by an n=3/2 poly trope and a neutron star represented by a point mass. The outcomes of the first encounters are found to be dependent only on the dimensionless parameter $\eta'{\equiv}(m/(m+ M))^{1/2}(\gamma_{min}/R_{MS})^{3/2}(m/M)^{{1/6)}$, where m and M are the mass of the main-sequence star and the neutron star, respectively, $\gamma_{min}$ the minimum separation between two stars, and $R_{MS}$ the size of the main-sequence star. The material from the (at least partially) disrupted star forms a disk around the neutron star. If all material in the disk is to be acctreted onto the neutron star's surface, the mass of the disk is enough to spin up the neutron star to spin period of 1 ms.

  • PDF

Modified Ramp-Reset Waveform Robust for Variable Panel Temperature and its Discharge Characteristics

  • Jang, Soo-Kwang;Tae, Heung-Sik;Kim, Soon-Bae;Jung, Eun-Young;Suh, Kwang-Jong;Ahn, Jung-Chull;Heo, Eun-Gi;Lee, Byung-Hak;Lee, Kwang-Sik
    • Journal of Information Display
    • /
    • v.7 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • By the voltage threshold (Vt) close-curve measurement method, the changes in the discharge characteristics such as a firing voltage and IR emission among the three electrodes were examined relative to the low or high panel temperature ranging from -10 to $80^{\circ}$. The variation in the panel temperature was found significantly influence the surface discharge between the MgO surfaces rather than the plate gap discharge between the MgO and phosphor layers. Based on this experimental observation, a modified reset waveform that alleviates the surface discharge during a ramp-up and -down period was deeloped. By adopting the proposed reset waveform, a stable address discharge could be obtained irrespective of the panel temperature variation.

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.471-476
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and c lose type heat pump system using effluent ground water was installed and tested for it church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000$ ton/day. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

A Study on Physical Fitness in Student Nurses (간호대학생의 체력에 관한 조사)

  • Kim Hyang-Dong;Park Jeong-Suk;Kwon Young-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.3
    • /
    • pp.399-407
    • /
    • 2003
  • Purpose: This study was done to identify levels of physical fitness in student nurses and to ascertain the relationship among the different aspects of physical fitness of strength, power, muscle endurance, agility, balance and flexibility. Method: The participants were 266 students selected from one college of nursing. From May 1 to July 31 in 2003, physical constitution, muscle strength (grip strength, back strength), power (standing long jump), muscle endurance (sit-ups), agility (whole body reaction time-light, sound), balance (close-eyes foot-balance), and flexibility (sitting trunk flexion) were measured. Result: The mean(standard deviation) for grip strength was 22.59(3.93) kg., for back strength, 48.52(12.85) kg., for standing long jump, 135.29(20.54) m., for sit-up's, 23.66(9.35) per minute, whole body reaction time (light), 0.43(0.11) sec, whole body reaction time (sound), 0.50(0.16) sec, close-eyes foot-balance, 33.35(38.67) sec, and sitting trunk flexion 34.72(9.37) cm. Conclusion: This study showed that the physical fitness of student nurses is very low compared to the results in a report from the Korea Sports Science Institute. It is necessary to include exercise programs for student nurses in order to improve their physical fitness.

  • PDF

Prognosis and evaluation of tooth damage caused by implant fixtures

  • Yoon, Wook-Jae;Kim, Su-Gwan;Jeong, Mi-Ae;Oh, Ji-Su;You, Jae-Seek
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.3
    • /
    • pp.144-147
    • /
    • 2013
  • Damage to adjacent teeth is one of the various complications that may occur during implant placement and is often the result of improper direction during fixture placement or excessive depth of placement. In general, if detrimental symptoms, such as reaction to percussion in damaged teeth, mobility, and pulp necrosis, are not present, osseointegration should be observed at follow-up. In three cases, the possibility of root damage due to an implant fixture placed too close to each adjacent tooth was perceived on radiographs. However, in all of these cases, there were no clinical symptoms or radiographic changes present in the tooth, and the implants did not exhibit decreased stability or peri-implantitis. Therefore, we can carefully predict that the implant fixture close to the adjacent tooth did not invade the cementum of the root, and therefore did not produce the suspected pulpal damage or periradicular symptoms. In this study, we considered both the implant status as well as the adjacent tooth.

Effects of Phytic Acid Content, Storage Time and Temperature on Lipid Peroxidation in Muscle Foods (근육식품에서 지방산화에 대한 피틴산, 저장기간 및 온도의 영향)

  • 이범준;김영철;조명행
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.1
    • /
    • pp.27-33
    • /
    • 1999
  • Phytic acid, making up 1~5% of the composition of many plant seeds and cereals, is known to form iron-chelates and inhibit lipid peroxidation. Thiobarbituric acid reactive substances (TBARS), as an indication of lipid peroxidation, were measured in beef round, chicken breast, pork loin, and halibut muscle after the meats were stored for 0, 1, 3, 5, and 7 days at various temperatures [frozen (~2$0^{\circ}C$), refrigerator (4$^{\circ}C$), and room temperature ($25^{\circ}C$)]. Phytic acid effectively inhibited lipid peroxidation in beef round, chicken breast, halibut, and pork loin muscle (p<0.05). The inhibitory effect of phytic acid was dependent on concentration, storage time, and temperature. At frozen temperature, the inhibitory effect of phytic acid was minimal, whereas at room temperature, the inhibitory effect of phytic acid was maximal, probably due to the variation of the control TBARS values. At the concentration of 10 mM, phytic acid completely inhibited lipid peroxidation in all the muscle foods by maintaining TBARS values close to the level of the controls, regardless of storage time or temperature (p<0.05). The rate of lipid peroxidation was the highest in beef round muscle, although they had a close TBARS value at 0 day. Addition of phytic acid to lipid-containing foods such as meats, fish meal pastes, and canned seafoods may prevent lipid peroxidation, resulting in improvement of the sensory quality of many foods and prolonged shelf-life.

  • PDF