• 제목/요약/키워드: Clogging factor

검색결과 24건 처리시간 0.032초

도시 지역특성을 고려한 빗물받이 유입구의 막힘계수 산정 (An Estimation of Clogging Factors at Stormwater Grate Inlets with Consideration of Urban Area Characteristics)

  • 김정수;송주일;윤세의
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.595-598
    • /
    • 2007
  • Urban storm water collection and conveyance systems are critical components of the urban infrastructures. During a storm event, street grate inlets are usually loaded with debris by the first-flush runoff volume. Grate inlets are subject to clogging effects. Effective interception area of grate inlets was decreased by clogging. It also decreased the interception capacity of grate inlets and increased the inundation area in street. Therefore, it is necessary to analyze the clogging characteristics and interception capacity change by clogging for appropriate design and management of grate inlets. In this study, field survey was executed to investigate debris and clogging pattern of grate inlet in 9 areas. The clogging factor with consideration of urban area characteristics was estimated with the field survey results.

  • PDF

도시지역에서 빗물받이의 막힘계수 산정에 관한 실험적 연구 (An Experimental Study for Clogging Factors Estimation of Grate Inlets in Urban Area)

  • 김정수;권인섭;윤세의;이종태
    • 대한토목학회논문집
    • /
    • 제26권2B호
    • /
    • pp.179-186
    • /
    • 2006
  • 빗물받이가 자갈, 토사 및 기타 유송잡물에 의하여 막히게 되면, 유입구의 순 면적이 감소하게 되므로 설치된 빗물받이는 제 기능을 다하지 못하여 도로의 침수피해를 가중시키는 요인이 된다. 그러므로 빗물받이의 합리적인 설계와 관리를 위하여 빗물받이의 막힘 현상을 분석할 필요가 있다. 본 연구에서는 8가지의 막힘 조건을 가진 $40{\times}50cm$ 규모의 빗물받이를 설치하여 도로의 종경사, 측구의 횡경사 및 막힘 정도를 변화시키면서 총 81회의 실험을 실시하였다. 실측자료를 분석한 결과 빗물받이 유입구가 연석방향으로 막힌 경우가 흐름방향으로 막힌 경우보다 차집효율이 현저하게 감소하였다. 막힘 조건을 가진 유입부에서도 도로의 종경사가 증가할수록 유속이 증가하여 물의 튐 현상(splash-over)이 크게 발생하여 빗물받이의 차집 효율을 감소시킨다. 또한 빗물받이의 설계 시 외국에서 일반적으로 채택되고 있는 막힘 정도가 50%일 경우에 도로의 종경사와 측구의 횡경사의 변화를 고려한 국내 빗물받이의 막힘계수는 0.25~0.65로 판단된다.

여과형 시설에 적용되는 여재의 처리효율 영향인자를 고려한 실증화 평가 (Verification of the Filter Media Applied to Filter Type Facility Considering the Treatment Efficiency Factor)

  • 김태윤;이준배;이동우;신현석;김현철;권순철
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.572-579
    • /
    • 2017
  • Increased impervious surface caused by rapid urbanization serves to produce the discharge of non-point source pollutants such as total suspended solid (TSS). There exist various methods of removing TSS, including a filtration process using granular media (a well-known method to be practically used after the consideration of removal efficiency, clogging, and backwashing efficiency). To determine the TSS removal capability of the filter, we initially performed lab-scale experiments which assessed flow rates, influent concentrations, permeability co-efficients, the particular shapes of suspended solids and potential clogging, and also evaluated TSS removal efficiency when applied to filtration facility in a pilot-scale. In low filtration flux condition, the removal efficiency of suspended solids was more than 95 %, while decreased to 83% in high filtration flux. Regarding the clogging aspect of the experiment, total cumulative solids were loaded up to $19.15kg/m^2$, and TSS removal efficiency was noted to commence to decrease when the loaded solids exceeded $9.0kg/m^2$. It was also noted, however, that superior efficiency was maintained for six hours. In addition, for pilot-scale experiment, the removal efficiency was still high enough (83.4 %) for the solid concentration of 140 ~ 343 mg SS/L and after backwashing, head loss was recovered to 92 ~ 95 % during two hour filtration. With these results, It was confirmed that lifetime of the filter applied to the test was prolonged due to the high treatment efficiency and good backwashing efficiency for the cumulative solids load.

Gene Expression Analyses of Mutant Flammulina velutipes (Enokitake Mushroom) with Clogging Phenomenon

  • Ju-Ri Woo;Doo-Ho Choi;Muhammed Taofiq Hamza;Kyung-Oh Doh;Chang-Yoon Lee;Yeon-Sik Choo;Sangman Lee;Jong-Guk Kim;Heeyoun Bunch;Young-Bae Seu
    • Mycobiology
    • /
    • 제50권5호
    • /
    • pp.366-373
    • /
    • 2022
  • Regulation of proper gene expression is important for cellular and organismal survival, maintenance, and growth. Abnormal gene expression, even for a single critical gene, can thwart cellular integrity and normal physiology to cause diseases, aging, and death. Therefore, gene expression profiling serves as a powerful tool to understand the pathology of diseases and to cure them. In this study, the difference in gene expression in Flammulina velutipes was compared between the wild type (WT) mushroom and the mutant one with clogging phenomenon. Differentially expressed transcripts were screened to identify the candidate genes responsible for the mutant phenotype using the DNA microarray analysis. A total of 88 genes including 60 upregulated and 28 downregulated genes were validated using the real-time quantitative PCR analysis. In addition, proteomic differences between the WT and mutant mushroom were analyzed using two-dimensional gel electrophoresis and matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF). Interestingly, the genes identified by these genomic and proteomic analyses were involved in stress response, translation, and energy/sugar metabolism, including HSP70, elongation factor 2, and pyruvate kinase. Together, our data suggest that the aberrant expression of these genes attributes to the mutant clogging phenotype. We propose that these genes can be targeted to foster normal growth in F. velutipes.

끈상접촉산화시설을 이용한 하천수질정화 (Purification of Stream Water Quality by Using Rope Media Filter)

  • 정용준;임기성
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.238-243
    • /
    • 2006
  • In order to improve the water quality of stream water, the facilities equipped with rope media filter have been examined as a part of national projects. This work may provide design and operating parameters from 2 years monitoring for 2 streams. Depending on the characteristics of streams, the flow rate into the facilities were shown different, where K stream was almost the same and D stream was less than 25% of design flow rate. Although the clogging of filter media was not observed during the operation, the removal of accumulated sludges was required for the stable operation. The removal efficiencies of BOD, SS, T-N and T-P for D stream were 60.5%, 80.1%, 25.2% and 36.2%, respectively. The most important factor for the construction of stream water purification facilities was recommended for the selection of proper sites.

국내 연약지반특성을 고려한 연직배수재 필터 시방기준에 대한 기초연구 (Study on the Specification for the Filter of the PBD)

  • 고영희;권수영;이종성;현승훈;이주공
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1102-1107
    • /
    • 2005
  • In this study, a specification for the filter system of plastic board drain using in korea. When PBDs was installed in the soft ground, bridging, blocking, blinding and clogging phenomena could be appeared near the PBD. Especially, clogging phenomena near the filter of PBD is very important factor to determine the life span of the vertical drainage system. Therefore, in this study, we proposed the specification on the filter of PBD considering the size of soil particle. To verify the proposed specification, model tests were conducted by using filter seepage tester. From the model test, newly proposed specification which considered the size of soil particle maintained the ability of seepage of the filter system of PBD.

  • PDF

슬러리 쉴드 터널의 막장 안정성 평가 - 슬러리의 폐색효과를 중심으로 - (Face Stability Assessment of Slurry-shield Tunnels - Concentrating on Slurry Clogging Effect -)

  • 이인모;이샘;조국환
    • 한국지반공학회논문집
    • /
    • 제20권6호
    • /
    • pp.95-107
    • /
    • 2004
  • 슬러리 쉴드 터널에서 슬러리 침투의 유동학적 특성은 막장안정성 측면에서 중요하다. 특히, 슬러리의 침투는 막장 안정성에 큰 영향을 미치며, 본 연구에서 이런 유동학적 특성을 파악하기 위하여 흙-필터의 폐색이론을 적용하였다. 터널시공 도중 슬러리 폐색의 지표로 필터계수를 사용하였으며, 실내실험을 통해 이의 적용성을 규명하였다. 실내실험의 결과를 바탕으로 한 안정해석 결과, 막장안정성은 침투속도와 필터계수의 비율에 영향을 받음을 알 수 있었다. 또한, 슬러리의 침투깊이는 침투속도와 필터계수의 비율과 함께 증가하는 경향을 보였다. 막장안정성은 침투거리가 증가하면 감소하는 경향을 보였으며, 침투거 리를 줄이기 위하여 슬러리에 첨가제를 첨가하였다. 실험에 근거한 분석결과 첨가제가 필요한 한계 유효입경$(D_{10})$은 약 0.75mm임을 알 수 있었다. 슬러리 침투로 인한 막장 안정성은 터널공사시의 굴진속도에도 크게 영향을 받음을 알 수 있었다.

해수가 슬러리 쉴드 TBM 공법 적용성에 미치는 영향 (Effect of seawater on the applicability of a slurry shield TBM)

  • 유영무;김해만;김도형;이인모
    • 한국터널지하공간학회 논문집
    • /
    • 제21권2호
    • /
    • pp.243-256
    • /
    • 2019
  • 슬러리 쉴드 TBM (Slurry shield TBM) 공법에서 벤토나이트 슬러리의 침투와 필터 케이크의 형성 여부는 공법의 적용성에 영향을 미치는 중요한 요소이다. 그러나 벤토나이트 슬러리는 해수와 접촉하였을 때 팽윤성과 점도가 저하되어 공법에 대한 적용성을 확보하기 어렵다. 본 연구에서는 해수의 영향에 따른 슬러리 쉴드 TBM 공법의 적용성 변화를 평가하기 위해 슬러리의 해수 비율을 다르게 하여 주입 실험을 수행하였고 해수가 슬러리의 폐색 현상에 미치는 영향을 확인하였다. 그 결과, 해수의 비율이 0%에서 20%까지 증가할수록 폐색 효과에 의한 슬러리 쉴드 TBM 공법의 적용성을 나타내는 slurry clogging criteria (SCC)가 최대 67%까지도 감소하는 것을 확인하였다. 또한 슬러리의 물리적 성질이 동일함에도 지반 조건에 따라 SCC값이 공법 적용에 문제가 없는 수준에서 공법 적용을 위해 슬러리에 추가적인 처리를 요하는 수준으로 변화하는 것을 통해 슬러리 쉴드 TBM의 적용성을 평가할 때 슬러리의 특성뿐만 아니라 지반 조건에 대한 고려도 필요함을 입증하였다.

Effect of variation of water retention characteristics due to leachate circulation in municipal solid waste on landfill stability

  • M. Sina Mousavi;Yuan Feng;Jongwan Eun;Boo Hyun Nam
    • Geomechanics and Engineering
    • /
    • 제33권2호
    • /
    • pp.141-154
    • /
    • 2023
  • This study investigated the effect of water retention characteristics between aged and fresh Municipal Solid Waste (MSW) on the stability of the landfill. A series of transient numerical modeling for the slope of an MSW landfill was performed considering the variation of water retention characteristics due to leachate circulation. Four different scenarios were considered in this analysis depending on how to obtain hydraulic conductivity and the aging degree of materials. Unsaturated hydraulic properties of the MSW used for the modeling were evaluated through modified hanging column tests. Different water retention properties and various landfill conditions, such as subgrade stiffness, leachate injection frequency, and gas and leachate collection system, were considered to investigate the pore water distribution and slope stability. The stability analyses related to the factor of safety showed that unsaturated properties under those varied conditions significantly impacted the slope stability, where the factor of safety decreased, ranging between 9.4 and 22%. The aged materials resulted in a higher factor of safety than fresh materials; however, after 1000 days, the factor of safety decreased by around 10.6% due to pore pressure buildup. The analysis results indicated that using fresh materials yielded higher factor of safety values. The landfill subgrade was found to have a significant impact on the factor of safety, which resulted in an average of 34% lower factor of safety in soft subgrades. The results also revealed that a failed leachate collection system (e.g., clogging) could result in landfill failure (factor of safety < 1) after around 298 days, while the leachate recirculation frequency has no critical impact on stability. In addition, the accumulation of gas pressure within the waste body resulted in factor of safety reductions as high as 24%. It is essential to consider factors related to the unsaturated hydraulic properties in designing a landfill to prevent landfill instability.

Assessing the removal efficiency of Synedra sp. through analysis of field data from water treatment plants

  • Seo, Dae-Keun;Kim, Yeong-Kwan
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.141-149
    • /
    • 2020
  • Prechlorination could increase the removal efficiency of Synedra, but there was no significant effect of increasing the amount of chlorine added. However, a removal efficiency of greater than 80% was noted when ozone was injected at concentrations greater than 2 mg/L. Also, it was found that on addition of polyamine, a removal efficiency of 80% or more could be achieved. As a result of the analysis of field operation data from the water treatment plants G and B, it was found that at water treatment plant G, the filter run time decreased to 10 hours or less when only coagulant was injected, but the filter run time increased to around 40 hours when polyamine (3 mg/L) was also injected. The Synedra population in the raw water subsequently increased to 2,340 cells/mL, and the filter continued running for more than 20 hours. At water treatment plant B, the average Synedra removal efficiency was 56% when only coagulant was injected, and the filter run time decreased drastically with the increasing population of Synedra in the raw water. However, the removal efficiency of Synedra reached 79% when polyamine was injected together with the coagulant, 90% when ozone was also injected, and 95% when polyamine and ozone were injected together and the filter continued running for over 50 hours. The filter run time was maintained at 60 hours when a Synedra population of 6,890 cells/mL flowed into the Paldang water source, but the filter run time with Synedra at 1,960 cells/mL decreased rapidly from 65 hours to 35 hours when the ratio of the size of the individual Synedra reaching 250 ㎛ or more, increased from 38% to 94%. Therefore, the size of the Synedra is considered to be a factor that significantly influences filter clogging, as well as the size of the Synedra population.