• Title/Summary/Keyword: Clip data

Search Result 93, Processing Time 0.025 seconds

Factors Affecting the Relationship Between Renal Renin Activity and Plasma Renin Activity -I. Experiments in the Two Kidney one Clip Goldblatt Hypertensive Rats- (신장내(腎臟內) Renin Activity와 Plasma Renin Activity에 영향(影響)을 미치는 요인(要因) -I. 실험적(實驗的)인 신성고혈압(腎性高血壓)에 있어서의 영향-)

  • Cho, Kyung-W.;Kim, Sun-H.
    • The Korean Journal of Physiology
    • /
    • v.16 no.1
    • /
    • pp.63-68
    • /
    • 1982
  • The change of plasma renin activity is one of the most important parameters explaining the pathological physiology of the hypertension. The relation between renal renin activity and plasma renin activity has not well been documented since last decades. In an attempt to clarify the relationship a series of experiments have been done in rats. The following results were observed. 1) Renal renin activity of clamped kidney increased after silver clipping and the increments were maintained until four to five weeks of operation. 2) Renal renin activity of the untouched contralateral kidney was vulnerable to be suppressed just after clamping, and the activity disappered almost below the limitation of the radioimmunoassay sensitivity up to four weeks. 3) Plasma lenin activity was changed by the renal renin activity, but the regression coefficient from the two kidney one clip Goldblatt hypertensive rats was different from the sham-operated, or age-matched control rats. 4) Plasma renin activity of all the groups tested has the exponential curve in terms of renal renin activity. These data suggest that the renal renin activity is important to control the plasma renin activity in certain experimental condition, especially in chronic status.

  • PDF

Audio Event Detection Based on Attention CRNN (Attention CRNN에 기반한 오디오 이벤트 검출)

  • Kwak, Jin-Yeol;Chung, Yong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.465-472
    • /
    • 2020
  • Recently, various deep neural networks based methods have been proposed for audio event detection. In this study, we improved the performance of audio event detection by adopting an attention approach to a baseline CRNN. We applied context gating at the input of the baseline CRNN and added an attention layer at the output. We improved the performance of the attention based CRNN by using the audio data of strong labels in frame units as well as the data of weak labels in clip levels. In the audio event detection experiments using the audio data from the Task 4 of the DCASE 2018/2019 Challenge, we could obtain maximally a 66% relative increase in the F-score in the proposed attention based CRNN compared with the baseline CRNN.

A Method to Measure Damage Areas by the types of Railroad Hazardous Material through GIS Spatial Analysis (GIS 공간 분석기법을 통한 철도사고위험물질별 피해규모 자동추출방안)

  • Kim, Sang-Gyun;Kim, Si-Gon;Lee, Won-Tea
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1769-1778
    • /
    • 2009
  • Due to the industrialization and urbanization, the transport of hazardous materials increases, which rises possibilities in occurring prospective accidents in terms of hazardous material transport as well. This study applied the model developed from the previous research to analyze the scale of damage areas from the accidents related to hazardous material accidents, as well as suggested a method to measure automatically the scale of accident including casualties and environmental damage based on the guideline which suggests the quantities of hazardous materials exposed from an accident and was defined in the study of standardization for hazardous material classification. A buffering analysis technique of Geographic Information System (GIS) was applied for that. To apply the model which evaluates the scale of population and exposure to environment on each link, rail network, zones, rail accident data, rail freight trips, and locations of rivers etc were complied as a database for GIS analysis. In conclusion, a method to measure damage areas by the types of hazardous materials was introduced using a Clip and a Special Join technique for overlay analysis.

  • PDF

Development of Expert System for a Preliminary Bridge Design (교량의 예비설계를 위한 전문가 시스템의 개발)

  • Choi, Chang Koon;Choi, In Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.9-17
    • /
    • 1992
  • This paper represents the expert system for selecting the superstructure types of bridges in the part of a preliminary bridge design. The system is implemented with the expert system tool called K-CLIPS which uses the production system for knowledge representation and provides the mechanism of forward chaining. This expert system is composed of a knowledge base, data base and a knowledge module built by the tool which consists of the knowledges on design procedures. During symbolic processing the data base supports the sub system in knowledge base.

  • PDF

DEVELOPMENT OF A POST-PROCESSING PROGRAM FOR VISUALIZATION OF MRI DATA (MRI Data 가시화용 후처리 프로그램 개발)

  • Myong, H.K.;Choi, H.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.67-72
    • /
    • 2007
  • A post-processing program based on the OOP(Object-Oriented Programming) concept has been developed for visualization of MRI. User-friendly GUl(Graphic User Interface) has been built on the base of MFC(Microsoft Foundation Class). The program is organized as modules by classes based on VTK-library, and these classes are made to function through inheritance and cooperation which are an important and valuable concept of object-oriented programming. The major functions of this post-processor program are introduced and demonstrated, which include contour plot, surface plots, cut plot and clip plot as well as view manipulation (translation, rotation, scaling etc).

  • PDF

Treatment of Flail Chest and a Fixation Technique of Flail Segments (Flail Chest 의 치료와 늑골고정술)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 1975
  • Authors have reviewed the records of seven patients of multiple rib fractures with severe flail chest who were admitted to Hanyang University Hospital during the 3 years period from 1972 through 1975. Of the seven patients studied, automobile accidents led to the injuries in 4 cases, two patients were injured in fall from a tree and on the ox-heading. All who had a blunt trauma without any open wound on the chest. The numbers of the fractured ribs accounted for 6 to 9 of the ribs including double fractures from 3 to 5 ribs. The left side fractures occurred in the 6 patients and in the right only one patient. Thus the flail segment was more often located in the left antero-lateral position than in the right lateral position [the ratio was 6:1].. All cases had associated injuries. The injuries and multiple fractures were the most common associated injuries occurring in four and five of the patients respectively. The patients were classified as having associated head injuries when they were admitted in comatose or semicomatose state. When a major degree of instability of the thoracic cage exists, adequate respiratory change is not possible. For this reason the tracheostomy was performed in five patients in an acutely injured patient with flail chest only after an endotracheal tube has been inserted or after an endotracheal suction. All patients had secondary complications in the pleural cavity, such as hemothorax or hemopneumothorax with or without intrapulmonary hemorrhage and subcutaneous emphysema. Therefore, closed thoracostomy was performed in five patients in the emergency room. The thoracotomy was required in four patients: immediate operation without closed thoracostomy was performed in two patients and the thoracotomy was indicated in two patients after closed thoracostomy, because of increasing intrathoracic hemorrhage. As to the fixation of the flail segments, authors employed two techniques; one was towel clip traction of the flail segments and the other was intramedullary insertion of Kirschner`s wire in to the double fractured rib fragments for the fixation of the flail segments [Kirschner`s wire fixation]. Because` of an different results in the course of treatment between two techniques, data from patients with towel clip traction was compared with those from patients with thoracotomy and Kirschner`s wire fixation of the flail segments. Of the three patients with towel clip traction, two patients required bronchoscopic toilet due to lung atelectasis which developed because of inadequate motion of thoracic cage and poor expectoration. This was in contrast to the four patients with thoracotomy and Kirschner`s wire fixation, who didn`t these complication because of adequate motion of the thoracic cage and subsequent good expectoration.

  • PDF

Three-Dimensional Digital Subtraction Angiographic Evaluation of Aneurysm Remnants after Clip Placement

  • Ahn, Soon-Seob;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.185-190
    • /
    • 2010
  • Objective : The aneurysm remnants rate was evaluated via three-dimensional digital subtraction angiography (3D-DSA) in the postoperative evaluation of clipped aneurysms. Methods : Data on surgically clipped aneurysms of anterior circulation obtained via postoperative 3D-DSA from February 2007 to March 2009 were gathered. The results of the postoperative 3D-DSA and of two-dimensional digital subtraction angiography (2D-DSA) for the detection of aneurysm remnants were compared, and an investigation was performed as to why 2D-DSA had missed some aneurysm remnants that were detected in the 3D-DSA. Various surgical factors that revealed aneurysm remnants in the 3D-DSA were also evaluated. Results : A total of 39 neck remnants of 202 clipped aneurysms (19.3%) were confirmed in 3D-DSA, and these were classified according to Sindou's classification of aneurysm remnants. Patients with only a neck remnant found in the 3D-DSA represented 17.3% (35/202 aneurysms) of the whole series, and those with a residuum of neck plus sac found in the 3D-DSA represented 1.9% (4/202 aneurysms). The causes of aneurysm remnants were no full visualization (14/39, 35.9%), parent and perforator artery protection (10/39, 25.6%), clip design problems (8/39, 20.5%), and broadnecked aneurysm (7/39, 17.9%). Conclusion : Patients with ${\leq}2$mm aneurysm remnants showed an increased risk of undetectable aneurysm remnants in the 2D-DSA. The most frequent location of the missed aneurysm in 2D-DSA was the anterior communicating artery. 3D-DSA showed more aneurysm remnants than what is indicated in the existing literature, the 2D-DSA.

Design and Implementation of P2P-Based Data Service System to Reduce Server Load (서버 부하 감소를 위한 P2P 기반 데이터 서비스 시스템의 설계 및 구현)

  • Lee, Kwang-Hyon;Jeon, Hyung-Su;Yoo, Cheol-Jung;Chang, Ok-Bae
    • The KIPS Transactions:PartC
    • /
    • v.9C no.5
    • /
    • pp.615-626
    • /
    • 2002
  • Recently, as interest in Home networking is increased, research about multimedia clip service is gone. Because of the limit to bandwidth of home network, the problem of server traffic is increased by transferring many multimedia data through Client-Sewer Way for long. The data share network system applied is designed and implemented to solve this problem. P2P is connected directly between clients and exchanges data without going through a sewer. We implemented platform-independent System using Java and applied P2P skill to reduce server traffic.

Detecting Collisions in Graph-Driven Motion Synthesis for Crowd Simulation (군중 시뮬레이션을 위한 그래프기반 모션합성에서의 충돌감지)

  • Sung, Man-Kyu
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.1
    • /
    • pp.44-52
    • /
    • 2008
  • In this paper we consider detecting collisions between characters whose motion is specified by motion capture data. Since we are targeting on massive crowd simulation, we only consider rough collisions, modeling the characters as a disk in the floor plane. To provide efficient collision detection, we introduce a hierarchical bounding volume, the Motion Oriented Bounding Box tree (MOBB tree). A MOBBtree stores space-time bounds of a motion clip. In crowd animation tests, MOBB trees performance improvements ranging between two and an order of magnitude.

Surgical Management of Intracranial Aneurysms in the Endovascular Era : Review Article

  • Mason, Alexander M.;Cawley, C. Michael III;Barrow, Daniel L.
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.3
    • /
    • pp.133-142
    • /
    • 2009
  • The advent of endovascular therapy for intracranial aneurysms and the rapid advances in that field have supplanted microsurgical treatment for many intracranial aneurysms. Applying current outcome data and other parameters, nuances of selecting the modality of treatment for intracranial aneurysms are reviewed. Patient factors, such a age, co-morbidities, vasospasm and other medical conditions, are addressed. A custom-tailored multimodality treatment paradigm for the management of ruptured and unruptured aneurysms will maximize the favorable results seen in this difficult patient population.