• 제목/요약/키워드: Clip Gauge

검색결과 5건 처리시간 0.016초

줄눈콘크리트 포장의 줄눈 거동 측정 (Field Measurements of Joint Movements at JPCP)

  • 윤경구;김동호;홍창우;이주형
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.325-330
    • /
    • 2001
  • In this research, the early-age movements of joint at JPCP(Jointed Plain Concrete Pavement) were measured by field tests. The field tests were carried out for 5 days just after concrete placement, for 1 day after 52 and 72 days on Chung-Ang Expressway construction site in Dan-yang on the 28th and 29th of May 2001. The joint movements were measured by demec gauge and clip gauge. The results of regression analysis for the data measured during early 5 days showed that the joints of No.4, No.5, No.6, No.10, No.13, and No.15 could be considered as a moving joint. From data analysis on july 20, the joints of No.2, No.9, and No.10 showed the significant correlations from the minus value of coefficient of regression. As a result of regression data on August 8, joint movements occurred at all joints. Joint freezing and closure could be judged from the regression analysis using joint opening and total temperature measured at field tests.

  • PDF

Notch재 피로와 Kikukawa-Compliance법 (제 1 보 기초적 검토) (Notched Specimen Fatigue and Kikukawa's Compliance Technique(Part I.On Some Basic Testing Results))

  • 송지호;박영조
    • 대한기계학회논문집
    • /
    • 제2권1호
    • /
    • pp.10-18
    • /
    • 1978
  • Kikukawa's compliance method using the conventional crack mouth clip-on gauge was proposed as a desired measurement technique to monitor the notched specimen fatigue behavior. The measurement technique makes it possible to continuously monitor the initiation and growth of incipient small part-through crack originated at the notch root and the phenomenon of crack closure. The variarion of natural flaw geometry with fatigue cycling was investigated. The test results on 7075-T6 aluminium alloy suggest the dependence of effective stress intensity factor range ratio .upsilon. on the maximum stress intensity factor .KAPPA.max.

2017 - T 3 알미늄 合金 의 勞龜裂進展 과 龜裂닫힘現象 (Fatigue crack growth and crack closure in 2017-T3 Aluminum alloy)

  • 송지호;김일현;신용승
    • 대한기계학회논문집
    • /
    • 제4권2호
    • /
    • pp.47-53
    • /
    • 1980
  • Kikukawa-Compliance method using a conventional clip-on gauge was employed to investigate fatigue crack growth and crack closure in 2017-T3 aluminum alloy. The crack growth rate plot against stress intensity range .DELTA.K on a log-log diagram exhibits a bilinear form with a transition at the growth rate of 10$\^$-4/ mm/cycle. The bilinear form appears still in the plot of growth rate versus effective stress intensity range .DELTA.K$\_$eff/. Fatigue crack growth rate could be well represented by .DELTA.K$\_$eff. The experimental results indicate that the effective stress intensity range ratio U depends on the maximum stress intensity factor K$\_$max/, but the stress ratio R does not affect U. The crack opening stress intensity factor K$\_$op/ tends to increase with increasing K$\_$max/ and decrease with increasing .DELTA.K.

컨테이너선의 후 물재 용접부 취성 균열 전파에 대한 FCAW와 SAW의 비교 특성에 관한 연구 (Comparison of the Characteristics of FCAW and SAW for the Brittle Crack Propagation of Welded Parts of BCA Steel in Container Ships)

  • 최경신;이상훈;최정주
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.24-32
    • /
    • 2021
  • The size of container ships is increasing to increase the cargo loading capacity. However, container ships are limited in terms of the hull longitudinal strength. To overcome this limitation, brittle crack arrest steel can be used. This study was aimed at examining the influence of the heat input on the welding procedures of flux cored arc welding and submerged arc welding. In the experiment, the crack tip opening displacement test, which pertains to a parameter of fracture mechanics, was performed, and a 3-point bending tester was adopted. Based on the results, the crack measurement method was presented, and the stress expansion coefficient value for the pre-fatigue crack length was derived according to the heat input after the pre-cracking length was measured. It was noted that the heat input affected the crack tip opening displacement of brittle crack arrest steel.

임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구 (Strains of abutment and bones on implant overdentures)

  • 김명석;허성주;곽재영;김성균
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.222-231
    • /
    • 2009
  • 연구목적: 임플란트 피개의치에서 연결고정형과 비연결고정형 보철물 지대주와 골의 변형률을 비교하고 임플란트 식립 경사에 따른 변형률을 비교 분석하고자 하였다. 연구 재료 및 방법: 2개의 아크릴릭 레진 모형의 좌측과 우측 견치 부위에 2개의 외부연결형 임플란트를 각각의 모형에 식립하였다. 한 모형에는 두 개의 임플란트를 평행하게 식립하였고, 다른 모형에는 순측과 설측으로 10도의 이개도(divergence)를 가지게 임플란트를 식립하였다. 모형에서 바를 이용한 연결고정형 지대주와 볼을 이용한 비연결고정형 지대주를 고정체에 번갈아 연결하고, 각각의 경우 대응하는 유지장치가 부착된 피개의치를 제작하여 지대주 상에 안착시켰다. 전기저항 스트레인 게이지(strain gauge)를 이용하여 피개의치에 100 N에서 200 N의 부하를 가하였을 때 지대주와 가상골 표면의 변형률(strain)을 측정하였다. 결과 및 결론: 측정된 값들을 통계분석하여 얻은 결과는 다음과 같다. 바를 이용한 연결고정형 보철물은 비연결형 보철물 보다 높은 변형률 값을 보였다. 그러나 방향은 주로 압축력이었으며 부하는 분산되었다(P<.05). 볼을 이용한 비연결고정형 보철물은 연결고정형보다 낮은 변형률 값을 보였다(P<.05). 순측경사된 임플란트에서는 비연결고정형 보철물이 연결고정형 보철물보다 더 높은 변형률 값을 보였다. 설측경사된 임플란트는 순측경사된 임플란트보다 낮은 변형률을 보였다(P<.05). 임플란트가 평행하게 식립된 경우보다 평행하지 않게 식립된 경우 지대주와 가상골의 변형률 값이 더 높았다(P<.05).