• Title/Summary/Keyword: Clip Gauge

Search Result 5, Processing Time 0.02 seconds

Field Measurements of Joint Movements at JPCP (줄눈콘크리트 포장의 줄눈 거동 측정)

  • Yun, Kyong-Ku;Kim, Dong-Ho;Hong, Chang-Woo;Lee, Joo-Hyung
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.325-330
    • /
    • 2001
  • In this research, the early-age movements of joint at JPCP(Jointed Plain Concrete Pavement) were measured by field tests. The field tests were carried out for 5 days just after concrete placement, for 1 day after 52 and 72 days on Chung-Ang Expressway construction site in Dan-yang on the 28th and 29th of May 2001. The joint movements were measured by demec gauge and clip gauge. The results of regression analysis for the data measured during early 5 days showed that the joints of No.4, No.5, No.6, No.10, No.13, and No.15 could be considered as a moving joint. From data analysis on july 20, the joints of No.2, No.9, and No.10 showed the significant correlations from the minus value of coefficient of regression. As a result of regression data on August 8, joint movements occurred at all joints. Joint freezing and closure could be judged from the regression analysis using joint opening and total temperature measured at field tests.

  • PDF

Notched Specimen Fatigue and Kikukawa's Compliance Technique(Part I.On Some Basic Testing Results) (Notch재 피로와 Kikukawa-Compliance법 (제 1 보 기초적 검토))

  • ;;Park, Yung Jo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.2 no.1
    • /
    • pp.10-18
    • /
    • 1978
  • Kikukawa's compliance method using the conventional crack mouth clip-on gauge was proposed as a desired measurement technique to monitor the notched specimen fatigue behavior. The measurement technique makes it possible to continuously monitor the initiation and growth of incipient small part-through crack originated at the notch root and the phenomenon of crack closure. The variarion of natural flaw geometry with fatigue cycling was investigated. The test results on 7075-T6 aluminium alloy suggest the dependence of effective stress intensity factor range ratio .upsilon. on the maximum stress intensity factor .KAPPA.max.

Fatigue crack growth and crack closure in 2017-T3 Aluminum alloy (2017 - T 3 알미늄 合金 의 勞龜裂進展 과 龜裂닫힘現象)

  • 송지호;김일현;신용승
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.4 no.2
    • /
    • pp.47-53
    • /
    • 1980
  • Kikukawa-Compliance method using a conventional clip-on gauge was employed to investigate fatigue crack growth and crack closure in 2017-T3 aluminum alloy. The crack growth rate plot against stress intensity range .DELTA.K on a log-log diagram exhibits a bilinear form with a transition at the growth rate of 10$\^$-4/ mm/cycle. The bilinear form appears still in the plot of growth rate versus effective stress intensity range .DELTA.K$\_$eff/. Fatigue crack growth rate could be well represented by .DELTA.K$\_$eff. The experimental results indicate that the effective stress intensity range ratio U depends on the maximum stress intensity factor K$\_$max/, but the stress ratio R does not affect U. The crack opening stress intensity factor K$\_$op/ tends to increase with increasing K$\_$max/ and decrease with increasing .DELTA.K.

Comparison of the Characteristics of FCAW and SAW for the Brittle Crack Propagation of Welded Parts of BCA Steel in Container Ships (컨테이너선의 후 물재 용접부 취성 균열 전파에 대한 FCAW와 SAW의 비교 특성에 관한 연구)

  • Choi, Kyung-Shin;Lee, Sang-Hoon;Choi, JeongJu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.24-32
    • /
    • 2021
  • The size of container ships is increasing to increase the cargo loading capacity. However, container ships are limited in terms of the hull longitudinal strength. To overcome this limitation, brittle crack arrest steel can be used. This study was aimed at examining the influence of the heat input on the welding procedures of flux cored arc welding and submerged arc welding. In the experiment, the crack tip opening displacement test, which pertains to a parameter of fracture mechanics, was performed, and a 3-point bending tester was adopted. Based on the results, the crack measurement method was presented, and the stress expansion coefficient value for the pre-fatigue crack length was derived according to the heat input after the pre-cracking length was measured. It was noted that the heat input affected the crack tip opening displacement of brittle crack arrest steel.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).