• Title/Summary/Keyword: Clinical practice

Search Result 4,139, Processing Time 0.047 seconds

A Statistical Analysis of the Fereign Bodies in the Food and air Passages (식도 및 기도이물의 임상통계학적 고찰)

  • 정해영;권평중;박성준;민양기;김중환
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.4.1-4
    • /
    • 1978
  • The foreign bodies in the food and air passages are frequently observed in the field of otolaryngology, and the foreign bodies in the air passages have much significance in clinical practice because they may cause sudden death. A statistical study was done on 95 cases of foreign bodies in the food and air passages who had visited department of otolaryngology, Chung-Ang university from June, 1968 to April, 1978. The results were as follows; 1. The total cases of foreign bodies in the food and air passages was 95; 89 cases (93.7%) were in the food passage and the remaining (6.3%) were in the air passage. The ratio between the food passage and air passage was about 14. 8 to 1.0. 2. In distribution by sex, 64 cases (67.4%) were in male patients and the remaining 31 cases (32.6%) were in female patients. The ratio between male and female was 2.1 to 1.0. 3. The kinds of foreign bodies in the food in the order of their frequency, were coin, gogame stone and pebble. In the air passages, the peanut and bean were most frequently found. 4. In distribution by age, 64 cases (67.4%) of all foreign bodies were found in children under 5 year old, and coin was the most common kind of foreign body. Except for meat, almost all of foreign bodies were found in children under 10 year old. 5. There was chronologically no significant tendency in incidence; the incidence, however, had decreased during recent 2 years. 6. In the location of foreign bodies in the food passage, 70 cases (78.7%) were found at the first esophageal narrowing. Meat was more frequently found at second esophageal narrowing associated with cicatrical stenosis. Almost all of foreign bodies in the air passage was found in bronchi; 3 cases were in the right side of bronchi, and 2 cases were in the left side of bronchi and 1 case was in glottic region. 7. In duration of lodgement, 50 cases (52.6%) visited our hospital within 24 hours, and 3 cases after 30 days. 8. Under topical anesthesia, 83 cases (93.3%) of the foreign bodies in the food passage were removed by esophagoscopy, by 6 cases (6.7%) failed to be removed. All of the foreign bodies of the air passages (6 cases) were removed by bronchoscopy. Among them, 5 cases under 5 years old were removed by inferior bronchoscopy through tracheostomy site.

  • PDF

An Exploratory Study about the Importance of Selected Nursing Activities during the Puerperal Period, as Viewed by Women in the Puerperal Period and by Nurses Caring for Them (산모와 간호원이 본 선택된 산욕기 간호활동의 중요도에 관한 탐색적 연구)

  • 박주봉
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.1
    • /
    • pp.152-162
    • /
    • 1978
  • The desire to maintain health is increasing, consequently the role of nursing which has as one chief aim the solving of man′s basic problems is more and more important. Today, in spite of a growing concern about the nursing activities which nurses provide for individual human having specific needs, clinically in fact, it is questionable that individual′s expectation of nursing activities agrees with nurse′s performance of nursing activities. In this study the importance and agreement of the importance of the nursing activities during the hospitalized puerperal period as viewed by women in the puerperal period and by nurses caring for them, were assessed. The present study was undertaken in an attempt to furnish the basic data for expediting the progress of research activities in this area and further to be helpful in planning maternity nursing practice. The study population defined and selected was nurses (13) caring for women in the puerperal period and doing duty on obstetric & gynecologic ward at Y. hospital, and the women in puerperal period (39) as sum of 3 women selected by each nurse during the period of May 13th-June 4th 1976. The study data was collected by the direct interview method based on the questionnaire which the investigator made out. The study result was analyzed by percentage, t - test. The findings can be summarized as follows: 1. General characteristics of nurses doing duty on puerperal ward: a. Nurses′average age was 24.8 years old. b. 84.6% had educational background of 4 years of college. c. 69.2% had a religion. d. 53.8% were married. e. 53.8% had clinical experience of 1 year -3 years. f, 61.5% did duty on puerperal ward during 1 year -3 years. g. 46.2% desired to do duty on obstetric ? gynecologic ward. 2. General characteristics of the women who were studied during their puerperal period: a. Women′s average age was 26.4 years old. b. 79.5% had educational background above high school. c. 56.4% had a religion. d. 84.6% had living standard above medium. e. 89.7% had no occupation. f, 53,8% had previous hospitalization experience. g. 56.4% had previous delivery experience. 3. Examining the importance of 39 nursing activities during puerperal period selected by investigator, studied group of women considered that the most important nursing activity was "Record precisely about condition, medical treatment and nursing activity results etc". Nurses considered that the most important nursing activity was "Notice whether having pain and care for that". Both groups considered that the least important nursing activity was "Talk with her about topics such as news, hobbies, other interests". 4. Examining the importance of nursing activities in 4 specific categories, studied group of women considered that the most important nursing activity in physical nursing category was "Be sure of safety measure to prevent accidents, injuries", and nurses considered that the most important nursing activity was "Make her sleep and rest sufficiently". Studied group of women considered that the most important nursing activity in psychological category was "Explain about medical treatment and nursing activity ahead of time so she knows what to expect" , and nurses considered that the most important nursing activity was "Explain about puerperal period so she understands". Studied group of women considered that the most important nursing activity in relation to medical care was "Record precisely about condition, medical treatment and nursing activity results etc.", and nurses considered that the most important nursing activity was "Observing, cleaning and protecting the perineum" Studied group of women considered that the most important nursing activity in nursing category in preparation for discharge was "Instruct about personnel hygiene during puerperal period", and nurses considered that the most important nursing activity was "Instruct self-care to protect the perineum". 5. The analysis of this study showed a significant amount of disagreement computed by subtracting the nurse′s score from the patient′s score. Studied group of women put greater importance on physical nursing category, psychological nursing category, nursing in relation to medical care, than the nurses. These results were statistically significant at 0.01 level.

  • PDF

The Code of Medical Ethics for the Korean Academy of Child and Adolescent Psychiatry: Why Is It Important? (대한소아청소년정신의학회 의료윤리규정: 왜 필요한가?)

  • Koo, Young-Jin;Hwang, Jun-Won;Lee, Moon-Soo;Yang, Young-Hui;Bang, Soo-Young;Kang, Je-Wook;Lee, Dae-Hwan;Lee, Ju-Hyun;Kwack, Young-Sook;Kim, Seungtai Peter;Noh, Kyung Sun;Park, Sung-Sook;Bahn, Geon Ho;Song, Dong-Ho;Ahn, Dong Hyun;Lee, Young Sik;Lee, Jeong-Seop;Cho, Soo-Churl;Hong, Kang-E Michael
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.27 no.1
    • /
    • pp.2-30
    • /
    • 2016
  • This article provides an overview of the developmental history and rationale of medical ethics to establish the code of ethics and professional conduct of the Korean Academy of Child and Adolescent Psychiatry (KACAP). Most medical professional organizations have their own codes of ethics and conduct because they have continuous responsibility to regulate professional activities and conducts for their members. The Ethics and Award Committee of the KACAP appointed a Task-Force to establish the code of ethics and conduct in 2012. Because bioethics has become global, the Ethics Task Force examined global standards. Global standards in medical ethics and professional conduct adopted by the World Medical Association and the World Psychiatric Association have provided the basic framework for our KACAP's code of ethics and professional conduct. The Code of Ethics of the Americal Academy of Child and Adolescent Psychiatry has provided us additional specific clarifications required for child and adolescent patients. The code of ethics and professional conduct of the KACAP will be helpful to us in ethical clinical practice and will ensure our competence in recognizing ethical violations.

A study on Satisfactory Degree of Dental Laboratory Heads about Dental Technician Who graduated form Junior college in Seoul and Kyoung Gi ("서울, 경기 지역 치과경기소장의 전문대학 치기공과 출신 치기공사에 대한 만족도 조사")

  • Min, Byoung-Kuk
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.23-34
    • /
    • 1989
  • The great sudenn change of circle of dental laboratory technology brought mary discord between the new growing environmental group and the old group, In order to know the satisfactory degree of dental laboratory heads about all dental College, This Study was conducted for 49 detal technicians who graduated from junior laboratory heads in Seoul and Kyoung Gi area. The results are abtained as follow- 1. By age The degree of Satisfaction of items about all graduate dental technician were "41$\sim$45 age" group 26.53%), "46$\sim$50 age" group 22.45%, "36$\sim$40 age" group 18.36%, "31$\sim$35 age" group 12.24%, "51$\sim$55 age" group and "56$\sim$60 age" group 8.16% 60$\sim$age group 4.08% in order. 2. By Job Career. The Highest degree item out of Satisfaction about all graduated dental dental technician was 21$\sim$25 years group 28.5%, 16$\sim$20 years 20.4%, 11$\sim$15 years group 12.24%, 26$\sim$20%, 6$\sim$10 years group 4.08%, below 5 years group 2.04% in order. 3. By managing term of respondent's dental laboratory. The Satisfactory degree of items about all gradate technician were 7$\sim$10 years group 36.73% over 15 years group 22.45%, 11$\sim$14 years group 20.41%, 3$\sim$6 years group 14.29% below 2 years group 6.12% in order 4. By dental technician number of respondent's dental laboratory. The satisfactory degree intems about man were as follow; 6$\sim$9 persons group is 42.86 % The Satisfactory degree items about woman were one persons group in 34.69% 5. By born place The dental laboratory heads mean of inters about all dental technician were Seoul group 20.64 %, Kyoung Gi 17.20 %, Jen Nam group 14.99 % Chung Nam 9.5%in order 6. The satisfactory degree of items about all graduate dental technician were neither good nor bad group 32.65%, bad 6.12%, By ability of adaptaton, The satisfactory degree items about man were neither good nor bad group 42.86%, bad group 40.82%. The satisfactory degree of items about woman were neither good nor bad group 40.82% bad group 36.73%. 7. By sincerity. The satisfactory degree of items about man dental technician who graduated from Junior College were neither good nor bad group 52.02%, bad group 4.08, The satisfactory degree about woman dental technician graduated from Junior College were neither good nor bad group 42.86%, bad group 6.12%. 8. By ability of basical of items about man were bad group 40.82 %. The satisfactory degree about woman were 46.94%. 9. By cooperation relation ship. The satisfactory degree of items about man were neither good nor bad group 42.86%, bad group 10.20%. The satisfactory degree about woman were neither good nor bad group 42.86%, bad group 10.20 %. 10. By ability of work. The satisfactory degree of items about man were neither good nor bad group 48.98%, bad group 4.08%. The satisfactory degree about woman were neither good nor bad group 42.86%, bad group 6.12 %. 11. By the curriculum of the dental technician. The satisfactory degree of items about man were neither good nor bad group 67.35%, bad group 2.04%, The satisfactory degree about woman were neither good nor bad group 61.22%, bad group 6.12%. 12. By occupational satisfaction. The satisfactory degree of items about all graduate dental technician were fatisfied group 14.29%. By the out look of employment. The satisfactory degree of items about man greduate dental technician were neither good nor bad group 34.69 %, bad group 10.20%, about woman graduate dental technician were neither good nor bad group 44.90%, bad group 10.20%, Their employment prospect is not so bright or oprimistic due to the glut supply by graduates in the job-seeking market 13. The satisfactory rate on the artificial dental manufacturing world in terms of effects produced by juror College graduate dental technicians shared good group 40.82% bad group 2.04% 14. By cognition of the number of graduate dental technician. The satisfactory degree of dental laboratory heads about man graduate dental technician were too many group 38.78%, few group 6.12% about woman graduated dental technician were neither good nor bad group 30.6% few group 10,20%, The employment opportunities for the artifical dental technicians are getting decreased because of their excessive cumber in supply 15. The opinion regarding the initial salary. ranging from \160,000 to \200,000 for the junior college graduate dental technicians shared 57.14%. The top ratio, while the satisfaction reate on the academic study period of "3-year" group shared 22%, also the top ratio. 16. The improvement policy and prblematic issues presonted by the owner and operatore of atriticial dental manufacturing plants are as shown below First; The viewpoint that they contribute to the improvement of people's oral health in terms of their mission as artificial dental technicians. Second: The cultivation of basic technical ability to cope with clinical practice upon graduation Third; They require guidance in study and research in their filed of profession, that tray may beable to estaclish a from theory.

  • PDF

Comparing the dosimetric impact of fiducial marker according to density override method : Planning study (양성자 치료계획에서 fiducial marker의 density override 방법에 따른 선량변화 비교 : Planning study)

  • Sung, Doo Young;Park, Seyjoon;Park, Ji Hyun;Park, Yong Chul;Park, Hee Chul;Choi, Byoung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: The application of density override is very important to minimize dose calculation errors by fiducial markers of metal material in proton treatment plan. However, density override with actual material of the fiducial marker could make problem such as inaccurate target contouring and compensator fabrication. Therefore, we perform density override with surrounding material instead of actual material and we intend to evaluate the usefulness of density override with surrounding material of the fiducial marker by analyzing the dose distribution according to the position, material of the fiducial marker and number of beams. Materials and Method: We supposed that the fiducial marker of gold, steel, titanium is located in 1.5, 2.5, 4.0, 6.0 cm from the proton beam's end of range using water phantom. Treatment plans were created by applying density override with the surrounding material and actual material of the fiducial marker. Also, a liver cancer patient who received proton therapy was selected. We located the fiducial marker of gold, steel, titanium in 0, 1.5, 3.5 cm from the proton beam's end of range and the treatment plans were created by same method with water phantom. Homogeneity Index(HI), Conformity Index(CI) and maximum dose of Organ At Risk(OAR) in Planning Target Volume(PTV) as the evaluation index were compared according to the material, position of the fiducial marker and number of beam. Results: The HI value was more decreased when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Especially the HI value was increased when the fiducial marker was located farther from the proton beam's end of the range for a single beam and the fiducial marker's position was closer to isocenter for two or more beams. The CI value was close to 1 and OAR maximum dose was greatly reduced when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Conclusion: Density override with surrounding material can be expected to achieve more precise proton therapy than density override with actual material of the fiducial marker and could increase the dose uniformity and target coverage and reduce the dose to surrounding normal tissues for the small fiducial markers used in clinical practice. Most of all, it is desirable to plan the treatment by avoiding the fiducial marker of metal material as much as possible. However, if the fiducial marker have on the beam path, density override of the surrounding material can be expected to achieve more precise proton therapy.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Survey on Period Prevalence Rate and Therapeutic Practice For Low Back Pain in Adult Population of Rural Area (농촌지역 성인의 요통 유병률과 치료방법 조사)

  • Lee Seung-Ju;Park Jung-Han
    • The Journal of Korean Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.109-121
    • /
    • 1991
  • To investigate the period prevalence rate and therapeutic practic for low back pain (LBP) in the adult population of rural area, a personal interview was conducted for 2.024 persons or 20-59 years old in Seohu Myon, Andong County, Kyungpook Province between 1st and 20th of April, 1991. The period prevalence rate (l February 1990-31 January 1991) of LBP for 1,106 adults who were interviewed was $47.9\%$. The age adjusted period prevalence rate for males was $43.7\%$ and that for females was $52.3\%$ and the difference was statistically significant (p<0.005). Clinical course of th LBP was acute in $14.1\%$ of males and $9.0\%$ of females, recurrent in $57.0\%$ and $55.2\%$, and chronic in $28.9\%$ and $35.8\%$, respectively. Common causes of the LBP were insidious on set with aging without known cause$(48.1\%)$, heavy work $(15.1\%)$, and trauma $(11.3\%)$. Due to LBP $12.5\%$ of the patients were not able to stand or walk for more than an hour and $2.5\%$ were bed-ridden or unable to carry out daily routine. To have the LBP diagnosed $10.2\%$ of the patients utilized a oriental medical clinic or hospital, $31.3\%$ visited a clinic or hospital, and $56.6\%$ hat not utilized any medical facility. Main reason for not having the LBP diagnosed was that the LBP was tolerable. The most popular therapeutic method that the LBP patients chose at the first was drug and physical therapy. Herb medicine was most commonly used when the first therapeutic method was not effective and the acupuncture was the most popular choice of therapy when the second therapeutic method failed. Folk medicine was utilized in $15.5\%$ of the LBP patients and it included 36 regimens such as tincture of motherwort (Leonurus sibiricus), boiled chicken with liquor, etc. It was revealed by this survey that the LBP is a serious health problem in the rural area and many of the LBP patients do not utilize a clinic or hospital but take non-scientific folk remedy. To prevent the economic waste and side effects of the folk remedy, public health education is needed for tile rational therapy of LBP.

  • PDF

Hybrid Natural Orifice Transluminal Endoscopic Cholecystectomy in Dogs: Transgastric, Transcolonic and Transvaginal Approaches (개에서 자연개구부를 통한 하이브리드 내시경적 담낭절제술: 경위장관, 경결장 및 경질 접근법)

  • Kim, Soo-Hyun;Jeong, Seong-Mok;Shin, Sa-Kyeng;Kim, Seong-Su;Shin, Beom-Jun;Lee, Jae-Yeon;Park, Ji-Yeong;Kim, Myung-Cheol;Kim, Young-Il;Lee, Sang-Il;Kim, Ji-Yeon
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.497-505
    • /
    • 2011
  • Natural orifice transluminal endoscopic surgery is a newly emerging technique recently, with its many potential advantages in clinical practice. Cholecystectomy by Hybrid NOTES in this work, performed with single working channel endoscope in conjunction with a laparoscopic grasping forceps in dogs, is a "bridge" between laparoscopic procedure and pure NOTES. Three different approaches for cholecystectomy were carried out; transgastric, transcolonic and transvaginal. In all three approaches, abdominal opening was made by a 5 mm trocar, followed by making pneumoperitoneum of 4 mmHg with $CO_2$ insufflator. Transgastric cholecystectomy, single working channel endoscope was advanced to the peritoneal cavity through gastric incision in antral region made by endoscopic needle knife. Endoscope was retroflexed to visualize the gall bladder. Transcolonic access, incision for endoscopic entry was done at right ventral wall of descending colon, 15 cm inside from the anus. Incision in transvaginal access was made at right-ventral region, just caudal to the caudal tubercle. With the simple traction by the laparoscopic grasping forceps, good visualization of surgical field was obtained in all three groups. Cystic duct and artery were ligated with endoclips; for complete gall bladder dissection from liver, L-knife was used. Closure of incision sites were done in transgastric and transcolonic cholecystectomy by endoclips, not in transvaginal approach.

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.