• Title/Summary/Keyword: Clinical practice

Search Result 4,248, Processing Time 0.033 seconds

The Effect of Flipped Learning based Nursing Process Education on Self-Directed Learning Ability and Academic Achievement of Nursing Students (플립러닝을 기반으로 한 간호과정 교육이 간호대학생의 자기주도적 학습능력 및 학업성취도에 미치는 효과)

  • Kim, Seon-Hee;Gang, Moon-Hee
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.363-372
    • /
    • 2020
  • The purpose of this study is to evaluate the effect of nursing process education based on flipped learning on self-directed learning ability and academic achievement of nursing students. A quasi-experimental study employing a nonequivalent control group and pre-post design was conducted. The study group was composed of 135 college students enrolled in the 2nd grade of C nursing college as an experimental group and 103 college students enrolled in the 2nd grade of the D university nursing department as a control group. The experimental group participated in flipped learning with the theme of nursing process once a week for 5 weeks, and the control group applied the traditional teaching method. Data were analyzed using χ2-test and Independent t-test with SPSS 26.0 program. There were significant differences in self-directed learning ability(t=-4.71, p<.001) and academic achievement(t=-4.93, p<.001) of participants between experimental group and control group after completion of 5 sessions flipped learning. The results indicate that flipped learning can be used to improve self-directed learning ability and academic achievement of nursing students. As a result of this study, the basis for using flipped learning will be prepared, and furthermore, it will have a positive effect on the clinical practice and problem solving ability of nursing students.

Effect of Non-contact Korean Medical Treatment for Patients Recovering at Home with Positive Coronavirus Disease 2019 Diagnostic Test Results at a Local Public Health Center: A Retrospective Chart Review (지역 보건소에서 시행한 코로나 바이러스 감염증-19 진단 검사상 양성인 재택치료 환자의 비대면 한의진료 효과: 후향적 차트 리뷰)

  • Jeon, Chaeheun;Choi, Daejun;Kim, Gyeongmuk;Kim, Hyejin;Leem, Jungtae;Chi, Gyoo-yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.4
    • /
    • pp.130-137
    • /
    • 2022
  • Due to the coronavirus disease 2019 (COVID-19) pandemic, appropriate management of sequelae and treatment of infectious symptoms became increasingly important healthcare issues. Although the practice guidelines and treatment cases based on the East Asian traditional medicine have been reported, there are rare studies on the use of Korean medicine in Korea. Therefore, this study aimed to present the progress of non-contact Korean medical treatment for infected patients at a local public health center using retrospective chart review. A total of 18 patients were prescribed with 5 days of herbal decoction and medicine extract covered by the national health insurance. With the questionnaire form, the progression and improvement of symptoms before and after treatment were evaluated using the numerical rating scale (NRS), and the treatment satisfaction and opinions were obtained. The symptoms such as cough (5.56±2.23 to 2.89±2.14), sputum (6.11±1,75 to 3.28±2.47), sore throat (6.06±2.70 to 1.47±1.62), anorexia (5.56±2.63 to 1.94±2.21), nausea (3.75±1.71 to 1.17±1.11), diarrhea (3.40±2.63 to 1.50±1.51), chest tightness (4.93±2.46 to 2.29±2.30) and fatigue (6.44±1.79 to 2.67±1.88) all improved according to the NRS, and the satisfaction with herbal medicine treatment on a 5-point Likert scale was 4.24±0.90. No side effects and adverse reactions were reported. Thereupon non-contact Korean medical treatment can be concluded that it effectively reduces the COVID-19 infection mild symptoms in restrictive extent. Since the retrospective data does not include a control group, the more confirmative data is needed by multicenter and large-scale controlled clinical study afterwards.

Analysis of trunk and lower extremity muscle activity according to the compensation of arm during bridge exercise (교각운동시 팔의 보상작용에 따른 몸통 및 하지근육 활성도 분석)

  • Oh, Gku Bin;Kim, Se Hee;Kim, Ye Eun;An, Jun Sung;You, Si Yeon;Jung, Sang Jin;Cho, Ye Bin;Ju, Jin Han;Cho, Ki Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.3
    • /
    • pp.12-20
    • /
    • 2022
  • Background: The purpose of this study was to investigate the changes of trunk and lower extremity muscle activity according to the compensation of arm during bridge movement of healthy subject. Design: Cross-sectional Study. Methods: Twenty healthy subjects participated in this study. The subjects performed bridge exercise with 3 different arm positions(arm abduction 45°, 90° and cross-arms) and measured the muscle activity of the trunk and lower extrimity. During bridge exercise with 3 different arm positions, trunk (rectus abdominis, erector spinae) and lower extrimity muscle activity (gluteus medius, biceps femoris, tibialis anterior) were measured using wireless surface EMG. Results: Rectus abdominis and gluteus medius muscle were most activated during bridge exercise with arm abduction 90° and erector spinae and biceps femoris muscle were most activated during bridge exercise with arm abduction 45°. In addition, tibialis anterior muscle was most activated during bridge exercise with arm cross. However, these difference in muscle activity according to the arm position was not statistically significant. Conclusion: As a result of this study, we think that the change in arm position does not induce sufficient instability to increase the muscle activity of the trunk and lower extremity muscles. Therefore, various approaches for inducing instability of the support surface for increasing muscle activity when applying bridge movement in clinical practice should be explored.

A Convergence Study of Surface Electromyography in Swallowing Stages for Swallowing Function Evaluation in Older Adults: Systematic Review (노인의 삼킴 단계별 삼킴 기능 평가를 위한 표면 근전도 검사의 융합적 연구 : 체계적 문헌고찰)

  • Park, Sun-Ha;Bae, Suyeong;Kim, Jung-eun;Park, Hae-Yean
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.5
    • /
    • pp.9-19
    • /
    • 2022
  • In this study, a systematic review was conducted to analyze the method of applying sEMG to evaluate the swallowing function of the elderly at each stage of swallowing, and to help objectively measure the swallowing stage of the older adults in clinical practice. From 2011 to 2021, 7 studies that met the selection criteria were selected using Pubmed, Scopus, and Web of Science (WoS). As a result of this study, the older adults and adults were divided into an experimental group and a control group and the swallowing phase was analyzed using sEMG only for the older adults. sEMG was used to evaluate swallowing in the oral and pharyngeal stages, and the sEMG attachment site was attached to the swallowing muscle involved in each stage. The collected sEMG data were filtered using a bandpass-filter and a notch-filter, and were analyzed using RMS, amplitude, and maximum spontaneous contraction. In this study, it was found that sEMG can be used as a tool to objectively and quantitatively evaluate the swallowing function in stages. Therefore, it is expected that this study will activate various studies that incorporate sEMG to evaluate the swallowing function in stages.

A Systematic Review on the Intervention of Group Sensory Integration Therapy for Children in Korea (국내 아동을 대상으로 하는 그룹 감각통합치료 중재에 관한 체계적 고찰)

  • Bak, Ah-Ream
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.20 no.3
    • /
    • pp.60-71
    • /
    • 2022
  • Objective : This study aimed to summarize and present the effects of group sensory integration treatment applied to children with and without disabilities in Korea. Methods : The search period was from January 2010 to December 2021, and databases of 'The Journal of Korean Academy of Sensory Integration', 'The Korean Journal of Occupational Therapy', 'Koreanstudies Information Service System', 'Research Information Sharing Service', 'DBpia' were used for data search. A total of 11 studies were selected, and the Patient, Intervention, Comparison, Outcome method was applied to organize them systematically. Results : As a result of the study, single-group non-randomized studies were the most common with 8 out of 11 studies (72.73%). There were 99 subjects, ranging in age from 3 to 11, and an average of 7.39. Among them, there were more children with disabilities, and 40 out of 99 (40.41%) were diagnosed with developmental disabilities the most. A total of 5 to 45 treatment intervention sessions were provided, and 60 minutes were the most frequently provided once or twice a week. The Canadian Occupational Performance Measure and The Penn Interactive Peer Play Scale were the most commonly used evaluation tools in 4 times each (12.90%). As the treatment intervention goal, social interaction skills was the most common with 8 studies (36.36%). As a result of treatment intervention, 8 studies showed significant results. Conclusion : Based on this study, it is expected that in the future, various methods of intervention of sensory integration therapy based on high quality levels can be systematically presented and used as useful information in clinical practice.

Efficiency and accuracy of artificial intelligence in the radiographic detection of periodontal bone loss: A systematic review

  • Asmhan Tariq;Fatmah Bin Nakhi;Fatema Salah;Gabass Eltayeb;Ghada Jassem Abdulla;Noor Najim;Salma Ahmed Khedr;Sara Elkerdasy;Natheer Al-Rawi;Sausan Alkawas;Marwan Mohammed;Shishir Ram Shetty
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.193-198
    • /
    • 2023
  • Purpose: Artificial intelligence (AI) is poised to play a major role in medical diagnostics. Periodontal disease is one of the most common oral diseases. The early diagnosis of periodontal disease is essential for effective treatment and a favorable prognosis. This study aimed to assess the effectiveness of AI in diagnosing periodontal bone loss through radiographic analysis. Materials and Methods: A literature search involving 5 databases (PubMed, ScienceDirect, Scopus, Health and Medical Collection, Dentistry and Oral Sciences) was carried out. A specific combination of keywords was used to obtain the articles. The PRISMA guidelines were used to filter eligible articles. The study design, sample size, type of AI software, and the results of each eligible study were analyzed. The CASP diagnostic study checklist was used to evaluate the evidence strength score. Results: Seven articles were eligible for review according to the PRISMA guidelines. Out of the 7 eligible studies, 4 had strong CASP evidence strength scores (7-8/9). The remaining studies had intermediate CASP evidence strength scores (3.5-6.5/9). The highest area under the curve among the reported studies was 94%, the highest F1 score was 91%, and the highest specificity and sensitivity were 98.1% and 94%, respectively. Conclusion: AI-based detection of periodontal bone loss using radiographs is an efficient method. However, more clinical studies need to be conducted before this method is introduced into routine dental practice.

Correlation between Serum IGF-1, IGFBP-3 Levels, and Hand-Wrist Radiographs in Determining Skeletal Maturity (골 성숙도 결정 시 혈청 IGF-1, IGFBP-3 농도와 수완부 방사선 사진의 상관관계)

  • Misun Kwak;Yon-joo Mah
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.3
    • /
    • pp.334-346
    • /
    • 2023
  • The aim of this study was to assess the correlation between serum levels of insulin-like growth factor-1 (IGF-1), insulin-like growth factor binding protein-3 (IGFBP-3), and hand-wrist radiographs using a skeletal maturity indicator (SMI) and the middle phalanx of the third finger (MP3). Hand-wrist radiographs and blood samples from 205 patients aged 7 - 17 years were retrospectively analyzed by two dentists using the SMI stages, MP3 stages, and serum IGF-1 and IGFBP-3 levels. Serum IGF-1 levels were highest at the SMI 6 - 8 and MP3 - G stage and lowest at the SMI 1 - 3 and MP3 - F stage (p < 0.0001). Serum IGFBP-3 levels were highest at the SMI 9 - 10 and MP3 - I stage and lowest at the SMI 1 - 3 and MP3 - FG stage (p = 0.010, 0.030). As a result of Pearson correlation analysis, a relatively high correlation was found between skeletal maturity using the SMI and MP3 stages and serum IGF-1 levels (r = 0.698, 0.622, p < 0.0001). According to the results of this study, serum IGF-1 levels can be used as an auxiliary measure to evaluate the skeletal maturity of children and adolescents in dentistry. The range from the mean serum IGF-1 level of 472 ㎍/L in SMI 6 stage to the mean IGF-1 level of 510.63 ㎍/L in MP3 G stage could be considered as the peak height velocity in clinical practice.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

Calculation Formula for Effective Photon Energy in kV X-ray Beam of Mammography (유방촬영의 kV X-선 빔에서 유효광자에너지에 대한 계산식)

  • Young-On Park;Sang-Hun Lee;Jong-Eon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.507-514
    • /
    • 2023
  • The purpose of this study is to find a formula that can easily calculate the effective photon energy in the X-ray beam of mammography. The tube voltage measured for each set tube voltage was obtained using the X2 MAM Sensor. The mass attenuation coefficient for aluminum of the aluminum filter was obtained from the half value layer measurement from each measured tube voltage X-ray beam. The mass attenuation coefficient of aluminum obtained from each measured tube voltage X-ray beam was corresponded to the mass attenuation coefficient of aluminum for each photon energy obtained from NIST. The photon energy corresponding to the matching mass attenuation coefficient was determined as the effective photon energy. The formula for calculating the determined effective photon energy was obtained by polynomial matching of the effective photon energy for each tube voltage in the Origin pro 2019b statistical program as y = 28.98968-1.91738x + 0.07786x2-0.000946717x3. Here, x is the measuring tube voltage and y is the effective photon energy. The calculation formula of the effective photon energy of the mammography X-ray beam obtained in this study is considered to be very useful in obtaining the interaction coefficient between the X-ray beam and a certain substance in clinical practice.

Effect of diabetes-specific oral nutritional supplements with allulose on weight and glycemic profiles in overweight or obese type 2 diabetic patients

  • Jihye Tak;Minkyung Bok;Hyunkyung Rho;Ju Hyun Park;Yunsook Lim;Suk Chon;Hyunjung Lim
    • Nutrition Research and Practice
    • /
    • v.17 no.2
    • /
    • pp.241-256
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Diabetes-specific oral nutritional supplements (ONS) have anti-hyperglycemic effects, while D-allulose exerts anti-diabetic and anti-obesity effects. In this study, we investigated the efficacy and safety of diabetes-specific ONS, including allulose, on glycemic and weight changes in overweight or obese patients with type 2 diabetes mellitus (T2DM). SUBJECTS/METHODS: A single-arm, historical-control pilot clinical trial was conducted on 26 overweight or obese patients with T2DM (age range: 30-70 yrs). The participants were administered 2 packs of diabetes-specific ONS, including allulose (200 kcal/200 mL), every morning for 8 weeks. The glycemic profiles, obesity-related parameters, and lipid profiles were assessed to evaluate the efficacy of ONS. RESULTS: After 8 weeks, fasting blood glucose (FBG) level significantly decreased from 139.00 ± 29.66 mg/dL to 126.08 ± 32.00 mg/dL (P = 0.007) and glycosylated hemoglobin (HbA1c) improved (7.23 ± 0.82% vs. 7.03 ± 0.69%, P = 0.041). Moreover, the fasting insulin (δ: -1.81 ± 3.61 μU/mL, P = 0.017) and homeostasis model assessment for insulin resistance (HOMA-IR) (δ: -0.87 ± 1.57, P = 0.009) levels decreased at 8 weeks, and body weight significantly decreased from 67.20 ± 8.29 kg to 66.43 ± 8.12 kg (P = 0.008). Body mass index (BMI) also decreased in accordance with this (from 25.59 ± 1.82 kg/m2 to 25.30 ± 1.86 kg/m2, P = 0.009), as did waist circumference (δ: -1.31 ± 2.04 cm, P = 0.003). CONCLUSIONS: The consumption of diabetes-specific ONS with allulose in overweight or obese patients with T2DM improved glycemic profiles, such as FBG, HbA1c, and HOMA-IR, and reduced body weight and BMI.