• 제목/요약/키워드: Clinical measurement method

검색결과 522건 처리시간 0.026초

기본간호학 실습교육현황과 실습내용 개선을 위한 조사 연구 (A Study on the Contents of Fundamental Nursing Practice)

  • 이영휘;서화숙
    • 대한간호학회지
    • /
    • 제28권3호
    • /
    • pp.650-661
    • /
    • 1998
  • The purpose of this study was to provide fundamental data for determining contents of Fundamental Nursing Practice and developing desirable bedside nursing techniques for clinical nursing areas. Subjects for this study were 86 nurses who were employees of two university hospitals located in Seoul and a district area. Data were collected by questionnaires. Items of Fundamental Nursing Practice were classified into 72 items according to the result from content analysis of 9 textbooks of Fundamental Nursing. The results are as follows : 1) Items which above 80% of respondents practiced during the school inside practice or clinical nursing practice course were axillary temperature measurement, radial pulse measurement, respiratory rate measurement, application of oral hygiene, hand-washing technique, application of hot and cold bags, intramuscular injection technique, open bed-making, soap enema method, application of nelaton catheterization and oral and nasal suction methods. 2) Above 90% of respondents replied that all items except temperature measurement and bed-making were requisite contents for Fundamental Nursing Practice. Above 10% of respondents replied oral and rectal temperature measurement and bed-making were unnecessary content. 3) Above 90% of respondents replied that operating methods of all items except isolation technique, admission and discharge procedures, and retention enema in the Fundamental Nursing Practice course and clinical situation were consistent. The main reasons that respondents did not apply methods which they learned in the Fundamental Nursing Practice course to the clinical situation were 'insufficient time', 'colleagues were using different methods', 'insufficient supply of instuments' or 'inappropriate appliances'.

  • PDF

속중성자선의 선량분포에 관한 연구 (Fast Neutron Beam Dosimetry)

  • 이효남;지영훈;지광수;이동한
    • 대한방사선치료학회지
    • /
    • 제9권1호
    • /
    • pp.71-81
    • /
    • 1997
  • I. Objective and Importance of the Project We have been using MC-50 cyclotron and NT-50 neutron therapy machine for treating cancer patients since 1986 at Korea Cancer Center Hospital. It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine (Task Group 18), European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induce the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. II. Scope and Contents of the Project For establishing a unique technique of measurement and inventing a standard method of measurement of fast neutron beam, 1. to grasp the physical characteristics of neutron therapy machine 2. to study the principles for measrement of fast neutron beam 3. to get the dose distribution (dose rate, percent-depth dose, flatness etc) throught the actual measurement 4. to compare our data with those being cited world-widely.

  • PDF

Magnetoencephalography (MEG)의 임상적 유용성 (Magnetoencephalography and Clinical Application)

  • 박현미;신동진
    • Annals of Clinical Neurophysiology
    • /
    • 제1권2호
    • /
    • pp.154-159
    • /
    • 1999
  • Magnetoencephalography (MEG), the measurement of magnetic fields produced by neuronal current associated with normal and pathologic brain activities, is a totally noninvasive method for localizing functional regions of the brain. During the past several years, many clinical research centers are working to expand various fundamental functional brain regions, which can be easily localized, as well as to characterize magnetic abnormalities which accompany a wide variety of cerebral disease. At present, MEG is used in a number of clinical centers throughout the world for the presurgical functional localization of eloquent cortex, and for the non-invasive localization of epileptiform activity. And also, non-invasiveness means that it can be used for screening and repetitive follow-up measurement without concern for adverse effects. As procedures for activating various functional brain regions are standardized, and as the effects of specific cerebral diseases on the MEG are carefully documented in controlled studies, the number of routine neurological applications for MEG will increase significantly. In this paper, the basic principles of MEG are reviewed briefly with its clinical application to neurologic disease.

  • PDF

EAV경락계와 고전침구경락계의 경혈학적 비교.고찰 (Study on Comarison of EAV Measurement Points with Acupuncture Points)

  • 류경주;김정헌
    • 한국한의학연구원논문집
    • /
    • 제1권1호
    • /
    • pp.363-400
    • /
    • 1995
  • The electroacupuncture according to Voll(EAV) is a method of combining the fundamentals of classical acupuncture with the facilities of modern electronics for diagnostics and therapy. Classical acupuncture uses energy conducting lines called 'meridians' and acupuncture points situated along them. Dr. Voll is considered the founder of 'EAV' since he succeeded not only in finding a method of exact electric localization and in explaining the interelation between the acupuncture points and their individual organs, but he also succeeded in measuring the resistance of these points and in explaining the diagnostic meaning of the measured values. In the course of his research, Voll found numerous new measurement points and energy conducting vessels unknown to classical acupuncture, but indispensible for diagnosis of human organic functions. As a basis of modern research in meridian theory, I tried to compare EAV measurement point with classical acupuncture point.

  • PDF

경락 임피던스 측정 시스템 개발에 관한 연구 (Study on the Development of Meridian Impedance Measurement System)

  • 이우철;인창식;민경기
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • 한국전문물리치료학회지
    • /
    • 제26권3호
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

MCG 영상진단 검사에 관한 연구 (A Study on MCG Imaging)

  • 김종규
    • 대한임상검사과학회지
    • /
    • 제38권2호
    • /
    • pp.135-140
    • /
    • 2006
  • Magnetocardiography (MCG) is the measurement and analysis of the magnetic component of the electro-magnetic field of the human heart, usually conducted externally, using extremely sensitive devices such as a Superconducting Quantum Interference Device (SQUID). MCG is a totally noninvasive method, it uses neither radiation nor ultrasonics. The magnetic activity of the heart is registered from outside the thorax. MCG has a very high sensitivity and a high spatial resolution for very a small, local myocardial current. In comparison to the electrical signals measured by an ECG, the magnetic signal does not disturb the boundaries of tissues with different electrical properties. MCG measures the myocardial function rather than describing the morphology. MCG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other heart activity measurement techniques such as Electrocardiography (ECG). The clinical uses of MCG are in detecting various cardiac disorders including myocardial infarction, ventricular hypertrophy, ventricular conduction defects, Wolff-Parkinson-White (WPW) syndrome, sudden cardiac death and fetal magnetocardiography. Magnetocardiography may be used alone or together with electrcardiography for the measurement of spontaneous or overloaded activity and for research or clinical purposes.

  • PDF

In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교 (Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro)

  • 이인희;김유현
    • 대한임상검사과학회지
    • /
    • 제47권4호
    • /
    • pp.306-312
    • /
    • 2015
  • 알러지 반응이 일어나면 histamine이 방출되기 때문에 histamine을 정량 측정함으로써 유발된 알러지의 정도를 확인 할 수 있다. 일반적으로는 항원-항체반응으로 microplate reader를 이용하여 흡광도를 측정하여 정량 한다. 본 연구에서는 histamine 방출량을 측정함에 있어서 일반적인 항원-항체반응과 분석 화학적인 방법으로 HPLC-MS를 이용한 방법을 비교하였다. 세포주는 RBL-2H3를 사용하였고, C48/80으로 자극시켜 알러지를 유발하였다. 유발된 알러지는 ${\beta}$-hexosaminidase의 측정으로 탈 과립을 확인하였으며 실험의 정당성을 위하여 세포독성 능을 확인하였다. Histamine 정량에서 항원-항체반응에 의한 측정의 정량한계는 10.257 ppm이었고, HPLC-MS에 의한 정량한계는 0.020 ppm으로 현저한 차이를 보였다. 알러지 활성 및 항 알러지 실험에 있어서 histamine의 측정은 HPLC-MS를 이용한 분석이 더 정밀하고 정확한 실험인 것을 확인하였다.

$SEDIsystem^{TM}$을 이용한 적혈구 침강속도 측정의 평가 (Evaluation of Automated ESR Measuring System, $SEDIsystem^{TM}$)

  • 이정이;김경동;이채훈;김정숙
    • Journal of Yeungnam Medical Science
    • /
    • 제13권1호
    • /
    • pp.110-115
    • /
    • 1996
  • 적혈구 침강속도는 전통적인 검사의 하나로서 진단에 있어서는 다소 비특이적인 검사이지만 몇몇 질병의 activity를 평가하고 추적검사에 유용한 것으로 평가되고 있다. Westergren법이 표준화된 검사법으로 인정받고 있으나 보고자에 따라 CV값이 0.8-22.9%로 보고되고 있다. 저자들은 143명의 검체를 대상으로 ESR 자동화 기기인$SEDIsystem^{TM}$ 사용하여 ESR을 측정하고 modified Westergren법, Wintrobe법과 비교하여 임상에 적용될 수 있는지를 검토하였다. $SEDIsystem^{TM}$로 측정한 ESR 결과와 modified Westergren법으로 측정한 ESR 결과사이의 상관식 및 상관계수(r)는 y = 0.863x - 1.69 (r=0.830)이었고, $SEDIsystem^{TM}$로 측정한 ESR 결과와 Wintrobe법으로 측정한 ESR 결과사이의 상관식 및 상관계수(r)는 y = 1. 14x - 14.7 (r=0.789)이었고, 검체의 안정성을 평가하기 위해 시간에 따른 ESR의 반복 측정치는 통계적으로 유의한 차이는 없었다. 위의 결과로 볼 때 $SEDIsystem^{TM}$을 이용한 검사는 기존의 modified Westergren, Wintrobe법들과의 상관성이 높았고 4시간까지 안정된 결과를 보였으며 또한 대량의 검체를 신속하게 보고할 수 있어서 임상 혈액검사실에서 이용하기에 적합하다고 생각된다.

  • PDF

사상체질 진단의 객관화를 위한 제언 (The Suggestion of the clinical application of Sasang Constitutional Diagnosis)

  • 박혜선;김형순;김경요;이시우
    • 사상체질의학회지
    • /
    • 제13권2호
    • /
    • pp.138-143
    • /
    • 2001
  • 1. Background Among the clinical application of Sasang Constitutional diagnostic methods, a morphologic study of face is recognized by the Ministry of Health and Welfare as a legitimate Hanbang diagnostic method. But there are some indirect different view about this method. We should criticize this method for the better. 2. Method We criticize the current morphologic study of face by its literature basis, its measurement and its result, compared with ${\ulcorner}$Dongyisoosebowon${\lrcorner}$ and other related literatures. 3. Conclusions We suggest thar the current morphologic study of face is not proper for the clinical application of Sasang Constitutional diagnostic method in the point of the lack of literature basis and the intervention of the examiner's subjectivities.

  • PDF