• Title/Summary/Keyword: Clinical measurement method

Search Result 521, Processing Time 0.031 seconds

A Study on the Contents of Fundamental Nursing Practice (기본간호학 실습교육현황과 실습내용 개선을 위한 조사 연구)

  • 이영휘;서화숙
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.650-661
    • /
    • 1998
  • The purpose of this study was to provide fundamental data for determining contents of Fundamental Nursing Practice and developing desirable bedside nursing techniques for clinical nursing areas. Subjects for this study were 86 nurses who were employees of two university hospitals located in Seoul and a district area. Data were collected by questionnaires. Items of Fundamental Nursing Practice were classified into 72 items according to the result from content analysis of 9 textbooks of Fundamental Nursing. The results are as follows : 1) Items which above 80% of respondents practiced during the school inside practice or clinical nursing practice course were axillary temperature measurement, radial pulse measurement, respiratory rate measurement, application of oral hygiene, hand-washing technique, application of hot and cold bags, intramuscular injection technique, open bed-making, soap enema method, application of nelaton catheterization and oral and nasal suction methods. 2) Above 90% of respondents replied that all items except temperature measurement and bed-making were requisite contents for Fundamental Nursing Practice. Above 10% of respondents replied oral and rectal temperature measurement and bed-making were unnecessary content. 3) Above 90% of respondents replied that operating methods of all items except isolation technique, admission and discharge procedures, and retention enema in the Fundamental Nursing Practice course and clinical situation were consistent. The main reasons that respondents did not apply methods which they learned in the Fundamental Nursing Practice course to the clinical situation were 'insufficient time', 'colleagues were using different methods', 'insufficient supply of instuments' or 'inappropriate appliances'.

  • PDF

Fast Neutron Beam Dosimetry (속중성자선의 선량분포에 관한 연구)

  • Lee Hyo Nam;Ji Young Hoon;Ji Kwang Soo;Lee Dong Han
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.71-81
    • /
    • 1997
  • I. Objective and Importance of the Project We have been using MC-50 cyclotron and NT-50 neutron therapy machine for treating cancer patients since 1986 at Korea Cancer Center Hospital. It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine (Task Group 18), European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induce the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. II. Scope and Contents of the Project For establishing a unique technique of measurement and inventing a standard method of measurement of fast neutron beam, 1. to grasp the physical characteristics of neutron therapy machine 2. to study the principles for measrement of fast neutron beam 3. to get the dose distribution (dose rate, percent-depth dose, flatness etc) throught the actual measurement 4. to compare our data with those being cited world-widely.

  • PDF

Magnetoencephalography and Clinical Application (Magnetoencephalography (MEG)의 임상적 유용성)

  • Park, Hyeon-mi;Shin, Dong-Jin
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.154-159
    • /
    • 1999
  • Magnetoencephalography (MEG), the measurement of magnetic fields produced by neuronal current associated with normal and pathologic brain activities, is a totally noninvasive method for localizing functional regions of the brain. During the past several years, many clinical research centers are working to expand various fundamental functional brain regions, which can be easily localized, as well as to characterize magnetic abnormalities which accompany a wide variety of cerebral disease. At present, MEG is used in a number of clinical centers throughout the world for the presurgical functional localization of eloquent cortex, and for the non-invasive localization of epileptiform activity. And also, non-invasiveness means that it can be used for screening and repetitive follow-up measurement without concern for adverse effects. As procedures for activating various functional brain regions are standardized, and as the effects of specific cerebral diseases on the MEG are carefully documented in controlled studies, the number of routine neurological applications for MEG will increase significantly. In this paper, the basic principles of MEG are reviewed briefly with its clinical application to neurologic disease.

  • PDF

Study on Comarison of EAV Measurement Points with Acupuncture Points (EAV경락계와 고전침구경락계의 경혈학적 비교.고찰)

  • Ryu, Kyung-Joo;Kim, Jung-Heon
    • Korean Journal of Oriental Medicine
    • /
    • v.1 no.1
    • /
    • pp.363-400
    • /
    • 1995
  • The electroacupuncture according to Voll(EAV) is a method of combining the fundamentals of classical acupuncture with the facilities of modern electronics for diagnostics and therapy. Classical acupuncture uses energy conducting lines called 'meridians' and acupuncture points situated along them. Dr. Voll is considered the founder of 'EAV' since he succeeded not only in finding a method of exact electric localization and in explaining the interelation between the acupuncture points and their individual organs, but he also succeeded in measuring the resistance of these points and in explaining the diagnostic meaning of the measured values. In the course of his research, Voll found numerous new measurement points and energy conducting vessels unknown to classical acupuncture, but indispensible for diagnosis of human organic functions. As a basis of modern research in meridian theory, I tried to compare EAV measurement point with classical acupuncture point.

  • PDF

Study on the Development of Meridian Impedance Measurement System (경락 임피던스 측정 시스템 개발에 관한 연구)

  • Lee, Woo-Cheol;Yin, Chang-Shik;Min, Kyoung-Kee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

A Study on MCG Imaging (MCG 영상진단 검사에 관한 연구)

  • Kim, Jong-Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.135-140
    • /
    • 2006
  • Magnetocardiography (MCG) is the measurement and analysis of the magnetic component of the electro-magnetic field of the human heart, usually conducted externally, using extremely sensitive devices such as a Superconducting Quantum Interference Device (SQUID). MCG is a totally noninvasive method, it uses neither radiation nor ultrasonics. The magnetic activity of the heart is registered from outside the thorax. MCG has a very high sensitivity and a high spatial resolution for very a small, local myocardial current. In comparison to the electrical signals measured by an ECG, the magnetic signal does not disturb the boundaries of tissues with different electrical properties. MCG measures the myocardial function rather than describing the morphology. MCG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other heart activity measurement techniques such as Electrocardiography (ECG). The clinical uses of MCG are in detecting various cardiac disorders including myocardial infarction, ventricular hypertrophy, ventricular conduction defects, Wolff-Parkinson-White (WPW) syndrome, sudden cardiac death and fetal magnetocardiography. Magnetocardiography may be used alone or together with electrcardiography for the measurement of spontaneous or overloaded activity and for research or clinical purposes.

  • PDF

Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro (In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교)

  • Lee, In Hee;Kim, Yoo Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.306-312
    • /
    • 2015
  • The measurement of histamine is to determine the degree of allergy because the allergic reaction can lead to the release of histamine. In general, the antigen-antibody reaction was quantified by measuring absorbance using a microplate reader. In this study, we compare the method using a general antigen-antibody reaction and the method using a high performance liquid chromatography mass spectrometer (HPLC-MS) of chemical analysis in the measurement of histamine secretion. The cell line used was RBL-2H3, an allergic reaction was induced by stimulation with C48/80 (compound 48/80). Allergy-induced cells degranulation rate was confirmed by measurement of ${\beta}$-hexosaminidase and cytotoxicity was performed for the validity of the experiment. The quantitative determination of histamine showed a significant difference, since the quantitative limit of the measurement by the antigen-antibody reaction was 10.257 ppm while the quantitative limit of the measurement by HPLC-MS was 0.020 ppm. Measurement of histamine in allergic activity and anti-allergy tests showed that the HPLC-MS analysis rather than the analysis of the antigen-antibody reaction is a more precise and accurate test.

Evaluation of Automated ESR Measuring System, $SEDIsystem^{TM}$ ($SEDIsystem^{TM}$을 이용한 적혈구 침강속도 측정의 평가)

  • Lee, Jung-Ee;Kim, Kyung-Dong;Lee, Chae-Hoon;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.110-115
    • /
    • 1996
  • The ESR is one of the oldest laboratory test still in use. Although it lacks specificity in diagnosis, it can be effective for monitoring disease activity and following-up. The Westergren method is used for reference method, however coefficient of variation has been described 0.8% to 22.9% according to the literature. Since the ESR was invented in 1921, measurement technique has developed and automated measurement is introduced. We analyzed one hundred forty-three patient samples using $SEDIsystem^{TM}$ automated ESR measuring system and compared with modified Westergren and Wintrobe methods. Comparison between $SEDIsystem^{TM}$ and modified Westergren for ESR measurement yields the following regression equation; y = 0.863x - 1.69 (r=0.830), $SEDIsystem^{TM}$ and Wintrobe y = 1.14x - 14.7 (r=0.789), respectively. We repeated measurement to evaluate reliability, results are not significant in statistically. In conclusion, $SEDIsystem^{TM}$ automated ESR measurement correlated with modified Westergren and Wintrobe methods, reveal reliable results after 4 hours and can report rapidly for large samples. Thus, these results indicate that $SEDIsystem^{TM}$ automated ESR measurement may be useful tool for clinical practice.

  • PDF

The Suggestion of the clinical application of Sasang Constitutional Diagnosis (사상체질 진단의 객관화를 위한 제언)

  • Park, Hye-Sun;Kim, Hyung-Soon;Kim, Kyung-Yo;Lee, Si-Woo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.13 no.2
    • /
    • pp.138-143
    • /
    • 2001
  • 1. Background Among the clinical application of Sasang Constitutional diagnostic methods, a morphologic study of face is recognized by the Ministry of Health and Welfare as a legitimate Hanbang diagnostic method. But there are some indirect different view about this method. We should criticize this method for the better. 2. Method We criticize the current morphologic study of face by its literature basis, its measurement and its result, compared with ${\ulcorner}$Dongyisoosebowon${\lrcorner}$ and other related literatures. 3. Conclusions We suggest thar the current morphologic study of face is not proper for the clinical application of Sasang Constitutional diagnostic method in the point of the lack of literature basis and the intervention of the examiner's subjectivities.

  • PDF