• 제목/요약/키워드: Clearance time

검색결과 407건 처리시간 0.033초

Bromosulfophthalein의 체내동태 평가에 미치는 분석법의 영향: HPLC 법과 UV 흡광광도법의 비교 (Effect of Analytical Method on the Pharmacokinetic Evaluation of Bromosulfophthalein: Comparison of HPLC and UV Spectroscopy Method)

  • 오주희;차유경;이영주
    • Journal of Pharmaceutical Investigation
    • /
    • 제38권6호
    • /
    • pp.399-403
    • /
    • 2008
  • The aim of this study was to evaluate the difference of analytical methods for the pharmacokinetic study of bromosulfophthalein (BSP), an indicator of hepatobiliary function. The plasma and bile concentrations of BSP after intravenous administration were measured according to custom UV spectroscopy and HPLC, respectively. Plasma concentration of BSP measured by UV spectroscopy was similar to that measured by HPLC. There was no significant difference in the distribution volume, total body clearance, area under the curve and mean residence time of BSP between different analytical method groups. However, bile concentration of BSP measured by UV spectroscopy was overestimated compared with concentration measured by HPLC method. Biliary clearance of BSP obtained from UV spectroscopy method was almost 3 times higher than that obtained from HPLC method. Thus, a feasibility of UV spectroscopy method for high throughput pharmacokinetic evaluation of BSP was limited to the study based on the plasma concentration of BSP, not bile concentration.

The Influence of Cimetidine on the Pharmacokinetics of Diltiazem and its Main Metabolite in Rabbits

  • Park, Jun-Shik;Burm, Jin-Pil
    • Archives of Pharmacal Research
    • /
    • 제27권2호
    • /
    • pp.254-258
    • /
    • 2004
  • The purpose of this study was to investigate the pharmacokinetic alteration of diltiazem and its main metabolite, deacetyldiltiazem, after oral administration of diltiazem in rabbits with or with-out cimetidine co-administration. The area under the plasma concentration-time curve (AUC) of diltiazem was significantly elevated in rabbits pretreated with cimetidine, suggesting that the oral clearance, an index of intrinsic clearance, may be decreased by the cimetidine treatment. Consistent with the increased AUC by the treatment, peak plasma concentration ($C_{max}$) for diltiazem was also elevated. Apparent volume of distribution normalized by the bioavailability (($V_{d}$/F) of diltiazem increased sigrificantly in rabbits pretreated with cimetidine increased. Taken together with the fact that the first pass metabolism for diltiazem is the primary determinant for the oral bioavailability, these observations indicate that increases in the oral clearance and (($V_{d}$/F may be a manifestation of the decreased first pass metabolism. Consistent with the hypothesis, the AUC of deacetyldiltiazem was significantly decreased in rabbits with cimetidine treatment. Ratio of deacetyldiltiazem to total diltiazem in the plasma was significantly decreased in rabbits with cimetidine treatment. These observations suggested that the metabolism of diltiazem to deacetyldiltiazem was reduced by cimetidine treatment and that the dosage of diltiazem should be adjusted when the drug is co-administered chronically with cimetidine in a clinical setting.

병태동물(病態動物)에서의 약물(藥物)의 Hepatic Clearance에 관한 연구(硏究) I -병태가토(病態家兎)에서의 Bromphenol Blue의 간담수송(肝膽輸送)- (Hepatic Drug Clearance of Animal in Disease States I -Hepato-biliary Transport of Bromphenol Blue in Acute $CCl_4$ Intoxicated Rabbits-)

  • 우종학;김신근;이민화;한건
    • Journal of Pharmaceutical Investigation
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 1980
  • Bromphenol blue (BPB) was studied with rabbits in normal and disease states to understand the basic principles of hepato-biliary transport process, and the effect of disease states on the drug disposition. The time course of plasma concentration and of biliary excretion was studied in normal and $CCl_4$ intoxicated rabbits. A conspicuous retention of BPB clearance from the plasma was observed, and the slope of the first-phase of plasma curve was decreased in the intoxicated rabbits. The shape of biliary excretion was same in normal and intoxicated states, but the amount of BPB excreted into bile in the intoxicated states was much smaller than in normal states. A relationship was found which enables one to predict the pattern of uptake of BPB by the liver, and the pattern of excretion into the bile in normal states, but was not in $CCl_4$ intoxicated states. It may be that the application of this experiments would extend the effect of disease states on the drug disposition.

  • PDF

Tip Clearance Effects on Inlet Hot Streaks Migration Characteristics in Low Pressure Stage of a Vaneless Counter-Rotating Turbine

  • Zhao, Qingjun;Wang, Huishe;Zhao, Xiaolu;Xu, Jianzhong
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.25-34
    • /
    • 2008
  • In this paper, three-dimensional multiblade row unsteady Navier-Stokes simulations at a hot streak temperature ratio of 2.0 have been performed to reveal the effects of rotor tip clearance on the inlet hot streak migration characteristics in low pressure stage of a Vaneless Counter-Rotating Turbine. The hot streak is circular in shape with a diameter equal to 25% of the high pressure turbine stator span. The hot streak center is located at 50% of the span and the leading edge of the high pressure turbine stator. The tip clearance size studied in this paper is 2.0mm(2.59% high pressure turbine rotor height, and 2.09% low pressure turbine rotor height). The numerical results show that the hot streak is not mixed out by the time it reaches the exit of high pressure turbine rotor. The separation of colder and hotter fluid is observed at the inlet of low pressure turbine rotor. Most of hotter fluid migrates towards the rotor pressure surface, and only little hotter fluid migrates to the rotor suction surface when it convects into the low pressure turbine rotor. And the hotter fluid migrated to the tip region of the high pressure turbine rotor impinges on the leading edge of the low pressure turbine rotor after it goes through the high pressure turbine rotor. The migration of the hotter fluid directly results in very high heat load at the leading edge of the low pressure turbine rotor. The migration characteristics of the hot streak in the low pressure turbine rotor are dominated by the combined effects of secondary flow and leakage flow at the tip clearance. The leakage flow trends to drive the hotter fluid towards the blade tip on the pressure surface and to the hub on the suction surface, even partial hotter fluid near the pressure surface is also driven to the rotor suction surface through the tip clearance. Compared with the case without rotor tip clearance, the heat load of the low pressure turbine rotor is intensified due to the effects of the leakage flow. And the numerical results also indicate that the leakage flow effect trends to increase the low pressure turbine rotor outlet temperature at the tip region.

  • PDF

Calculation of a First-In-Man Dose of 7-O-Succinyl Macrolactin A Based on Allometric Scaling of Data from Mice, Rats, and Dogs

  • Noh, Keumhan;Kang, Wonku
    • Biomolecules & Therapeutics
    • /
    • 제25권6호
    • /
    • pp.648-658
    • /
    • 2017
  • 7-O-Succinyl macrolactin A (SMA) exerts several pharmacological effects including anti-bacterial, anti-inflammation, and anti-cancer activities. Recently, SMA has been extensively evaluated as an anti-cancer drug. Thus, the objectives of the present study were to characterise the pharmacokinetics of SMA via both non-compartmental and compartmental analysis in mice, rats, and dogs, and to derive an appropriate first-in-man dose based on allometric scaling of the animal data. The time courses of plasma SMA concentrations after intravenous administration to rats and dogs were analysed retrospectively, as were data collected after intraperitoneal SMA injection in mice. Pharmacokinetic parameters were estimated via both noncompartmental and compartmental analysis, and were correlated with body weight and/or the potential maximum life-span. The clearance and distribution volume of SMA in humans were predicted, and a first-in-man dose proposed. A two-compartment model best described the time courses of SMA plasma concentrations after a saturation elimination process was applied to fit the dataset obtained from rats. Incorporation of the maximum potential life-span during allometric scaling was required to improve the estimation of human clearance. The SMA clearance and the distribution volume in the steady state, in a 70-kg adult male, were estimated to be 30.6 L/h and 19.5 L, respectively. To meet the area under the curve (AUC) required for anti-tumour activity, a dose of 100 mg (~1.5 mg/kg) was finally proposed as the first dose for a 70-kg human. Although toxicological profiles derived from non-clinical studies must be considered before any final decision is made, our work will facilitate clinical studies on SMA.

An Empirical Study on Trade Facilitation by the Korean Government's Single Window System

  • Cheolkyu Maeng
    • Journal of Korea Trade
    • /
    • 제27권1호
    • /
    • pp.101-118
    • /
    • 2023
  • Purpose - Korea became a trillion-dollar trading country in 2011. With the exponential increase in Korea's trade volume over the past decades, trade-related administrative burdens per capita for Korea Customs became enormous, for which the government established the Single Window, a trade-facilitating system, in 2004 to enhance the efficiency of customs-clearing procedures for traders. This paper focuses on finding whether the Korean Single Window system affects the country's trade facilitation positively through an empirical methodology. Design/methodology - To find empirical evidence that Single Window affects trade facilitation for the customs-clearing procedure, this study assumes that a time-efficient environment enables the handling of the increase in trade volume, under which four independent variables related to import customs-clearing procedures and two dependent variables to import were adopted for empirical analysis. The import customs procedures are classified into four steps from port entry to declaration acceptance. To understand the relationship between variables, scattered plots and correlation coefficients were calculated. Eight hypotheses were set and underwent simple linear regression. The data for analysis were collected by Korea Customs, and were about the lead time of import, the volume of imports in million USD, and the number of import declarations reported to customs offices on a monthly basis from 2005 to 2013. Findings - Six of the eight hypotheses showed the statistically significant result that lead time in the import customs-clearing procedure positively affects the number of import declaration reports and import volume. Specifically, Hypothesis 1, Hypothesis 2, and Hypothesis 3 strongly support the assumption lead time in import customs declaration has an inverse relationship with the number of import declarations, which means that the shorter the import lead time, the more import declaration increases. Research Limitations/Implications - With limited data accessibility to the government's custom-sclearing procedures, only the import lead time for customs clearance were adopted as independent variables. This paper, however, successfully found that the Single Window system contributed to trade facilitation. Originality/value - This study found that the time-saving Single Window system of Korea Customs enables itself to manage an exponentially-increasing trade volume by creating a trade-facilitating environment for customs personnel and traders, which may be a unique implication found through quantitative methodology.

틈새 변화에 따른 공기 포일 베어링 시스템의 진동 특성에 대한 연구 (Study on the Vibration Characteristics of Air Foil Bearing System by Clearance Variation)

  • 신승훈;박정구;정규강
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.792-796
    • /
    • 2009
  • Application of air foil bearing (AFB) is widely using to cope with requirements of high speed and high efficiency system at turbo machinery. At same time, a wide variety of AFB design methods are required. In this paper, the AFB design factor influencing the most greatly in bearing performance was selected through theoretical analysis and vibration test was conducted using selected factor. Through this process, AFB system applicable for vehicle turbo machinery was developed.

  • PDF

미세 와이어의 버 없는 전단에 관한 연구 (Burrless shearing of the micro wire)

  • 김웅겸;홍남표;김헌영;김병희
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.52-56
    • /
    • 2006
  • Punching tools like an electrodes are made by milling or etching or EDM. These methods had time consuming, low efficiency and air pollution. So, we have developed a shearing device which counter punching method for burrless cutting of micro wire. Using the straightened SUS304 wire with $200{\mu}m$ diameter, we confirmed the tendency of the shear plane for punch tools. It was impossible to completely remove the bun in the shearing process. In order to minimize the burr size and fine shear plane, we have accomplished the various experiment conditions such as the U-groove, the effect of the counter punch, shear angle and clearance. The results of the experiments show that indentation, slip plane and bent shape were related to the shear angle and clearance.

다단축류압축기내의 천음속 점성유동에 대한 삼차원 수치해석 (The Calculation of Three-Dimensional Viscous Flow in a Transonic, Multi-Stage Axial Compressor)

  • 이형욱;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 춘계 학술대회논문집
    • /
    • pp.181-189
    • /
    • 1998
  • A numerical study based on the three-dimensional Reynolds averaged Navier-Stokes equations is presented to analyze the transonic flowfield through two-stage axial compressor. Explicit four-step Runge-Kutta scheme is used for solution algorithm, and local time step and implicit residual averaging are introduced for enhancing the convergency. Artificial dissipation model is adopted to assure the stability of solution. The solver is coupled with Baldwin-Lomax model to describe turbulence. To avoid calculating the unsteady flow, a mixing process is modeled at a station between rotating and stationary blade rows. Results show a variety of important physical phenomena. Comparison of the flowfields with and without tip clearance shows that the effect is considerable in this flowfield. Comparisons with experimental data carried out to validate the calculational results show reasonable agreements. Some remedies are also suggested to improve the revealed problems.

  • PDF