• Title/Summary/Keyword: Cleaning time

Search Result 622, Processing Time 0.029 seconds

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

Reduction of Toxic Emissions by Coal Cleaning (발전용 석탄의 전처리에 의한 중금속 배출)

  • 최우진;전호석;송규소;지평삼
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.57-64
    • /
    • 1996
  • 석탄중에는 미량원소(trace elements)가 포함되어 있으며 이들의 농도는 석탄의 종류나 산지에 따라 크게 다르다. 석탄중의 미량원소를 제거하는 것은 그동안 크게 문제가 되지 않았으나 최근 환경문제가 점차 고조되면서 이에 대한 관심이 높아지고 있다. 일반적으로 사람의 건강 및 환경에 유해한 원소중에서 화석연료 사용과 관련이 있는 원소는 비소(As), 카드늄(Cd), 납(Pb), 구리(Cu), 수은(Hg), 니켈(Ni), 셀레니움(Se) 및 아연(Zn) 등 8개 원소이다. 그러나 그외에도 배출규제의 대상이 되는 원소는 코발트(Co), 염소(Cl), 안티모니(Sb), 베릴리움(Be), 크롬(Cr)과 망간(Mn)이며 이중 망간은 석탄사용과 직접적인 관련이 있다. 따라서 Mn을 포함한 9개 원소가 석탄의 사용에 따른 중금속 방출과 관련이 있는 것으로 간주되고 있다. 본 연구에서는 발전용 석탄에 대한 물리적 전처리 공정을 적용하여 석탄중의 광물질등을 미리 제거하므로서 연소 후 배출되는 배기가스중의 중금속 저감 가능성을 관찰하였다. 본 연구결과 전처리 공정의 석탄중의 Trace elements양을 감소시키므로서 연소 후 중금속의 배출량을 크게 줄일 수 있음을 확인하였다. 발전소에 적용하고 있는 ESP가 배출가스중 As, Cu, Zn, Mn등의 중금속을 제거하는데 효율적이기는 하나 가스상으로 존재하는 Hg, Se등을 제거하는데는 효율적이지 못하다. 전처리공정 전후 회분중에 함유된 미량원소를 분석한 결과, 국내 무연탄이나 해외 유연탄 모두 중금속 제거에 있어서 유사한 경향을 보여주었으며, Pb, Zn, Mn 등은 50∼70%, 특히 Hg 배출량은 80% 이상 저감이 가능하였다. 전반적으로 년간 총 중금속 배출량도 50∼60%가 감소하여 전처리 공정이 석탄중의 중금속을 줄이는데 크게 기여함을 확인하였다.을 선택할 수 있는 메뉴 그리고 계산 결과를 파일로 혹은 프린트로 출력할 것을 선택할 수 있는 메뉴가 있다. 사용자는 해당되는 데이타를 입력한후 마우스로 원하는 작업의 메뉴를 선택하면 된다. 방법을 타액과 혈청내 testosterone 농도 측정에 응용하여 RIA의 결과와 비교하여 본 바 상관관계가 타액에서 r=0.969, 혈청에서 r=0.990으로 두 결과가 잘 일치하였다. 본 실험에서 측정된 한국인 여성의 타액내 testosterone농도는 107.7$\pm$12.0 pmol/l이었고, 남성의 타액내 농도는 274.2$\pm$22.1 pmol/l이었다. 이상의 결과로 보아 본 연구에서 정립된 EIA 방법은 RIA를 대신하여 소규모의 실험실에서도 활용할 수 있을 것으로 사려된다.또한 상실기 이후 배아에서 합성되며, 발생시기에 따라 그 영향이 다르고 팽창과 부화에 관여하는 것으로 사료된다. 더욱이, 조선의 ${\ulcorner}$구성교육${\lrcorner}$이 조선총독부의 관리하에서 실행되었다는 것을, 당시의 사범학교를 중심으로 한 교육조직을 기술한 문헌에 의해 규명시켰다.nd of letter design which represents -natural objects and was popular at the time of Yukjo Dynasty, and there are some documents of that period left both in Japan and Korea. "Hyojedo" in Korea is supposed to have been influenced by the letter design. Asite- is also considered to have been "Japanese Letter Jobcheso.

  • PDF

PHOTOCATALYTIC ANTIEUNGAL ACTIVITY AGAINST CANDIDA ALBICANS BY $TiO_2$ COATED ACRYLIC RESIN DENTURE BASE

  • Yang Ji-Yeon;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.284-294
    • /
    • 2006
  • Statement of problem. Proliferation of Candida albicans is primarily within the plaque on the fitting surface of the denture rather than on the inflamed mucosa. Consequently, the treatment of the denture is equally important as treatment of the tissue. Cleansing and disinfection should be efficiently carried-out as the organisms can penetrate into the voids of the acrylic resin and grow in them, from which they can continue to infect and reinfect bearing tissues. Purpose. The purpose of this study was to evaluate the applicability of photocatalytic reaction to eliminate Candida albicans from acrylic resin denture base, and to investigate the anti-fungal effect with various UVA illumination time. Materials and Methods. The specimens were cured by the conventional method following the manufacturer's instruction using thermal polymerized denture base resin (Vertex RS: Dentimex, Netherlands). $TiO_2$ photocatalyst sol(LT), which is able to be coated at normal temperature, was made from the Ti-alkoxide progenitor. The XRD patterns, TEM images and nitrogen absorption ability of the $TiO_2$ photocatalyst sol(LT) were compared with the commercial $TiO_2$ photocatalyst P-25. The experimental specimens were coated with the mixture of the $TiO_2$ photocatalyst sol(LT) and binder material (silane) using dip-coater, and uncoated resin plates were used as the control group. Crystallinity of $TiO_2$ of the specimen was tested by the XRD. Size, shape and chemical compositions were also analyzed using the FE-SEM/ EDS. The angle and methylene blue degradation efsciency were measured for evaluating the photocatalytic activity of the $TiO_2$ film. Finally, the antifungal activity of the specimen was tested. Candida albicans KCTC 7629(1 ml, initial concentration $10^5$ cells/ ml) were applied to the experiment and control group specimens and subsequently two UVA light source with 10W, 353 nm peak emission were illuminated to the specimens from 15cm above. The extracted $2{\mu}l$ of sample was plated on nutrient agar plate ($Bacto^{TM}$ Brain Heart Infusion; BD, USA) with 10 minute intervals for 120 minute, respectively. It was incubated for 24 hours at $37^{\circ}C$ and the colony forming units (CFUs) were then counted. Results. Compared the characteristics of LT photocatalyst with commercial P-25 photocatalyst, LT were shown higher activity than P-25. The LT coated experimental specimen surface had anatase crystal form, less than 20 nm of particle size and wide specific surface area. To evaluate the photocatalytic activity of specimens, methylene blue degradation reaction were used and about 5% of degradation rate were measured after 2 hours. The average contact angle was less than $20^{\circ}$ indicating that the LT photocatalyst had hydrophilicity. In the antifungal activity test for Candida albicans, 0% survival rate were measured within 30 minute after irradiation of UVA light. Conclusion. From the results reported above, it is concluded that the UVA-LT photocatalytic reaction have an antifungal effect on the denture surface Candida albicans, and so that could be applicable to the clinical use as a cleaning method.

PREVALENCE AND RISK FACTORS OF SEVERE EARLY CHILDHOOD CARIES IN PRESCHOOL CHILDREN IN IKSAN CITY (익산시 취학전 어린이의 중증 유아기 우식증 유병률과 위험요인)

  • Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.678-683
    • /
    • 2003
  • Preschool children in Iksan city, 3-5 years old, were examined for their prevalence of severe early childhood caries. The case definition was 1 or more cavitated, filled, or missing (due to caries) smooth surfaces in primary maxillary anterior teeth. Feeding behavior and oral hygiene behavior were investigated by a questionnaire. The prevalence was 20.8% for 36-47 months, 23.6% for 48-59 months, and 30.8% for 60-71 months. Going to sleep with bottle beyond 1 year (P<0.05), immediate removal of bottle after child fell on sleep (P<0.01), beginning time of toothbrushing (P<0.01) had significant relationship with the prevalence of severe early childhood caries. Toothbrushing frequency of primary care provider and use of oral cleaning aids by primary care provider had a tendency to be related with the prevalence(P<0.10).

  • PDF

The literatural study of investigating the contents associated with the neuropsychosis in the medical books published in the times of Chinese dynasty of Jin and Yuan (금원시대(金元時代)의 의서(醫書)에 나타난 신경정신질환(神經精神疾患)에 대한 고찰(考察))

  • Choi, Jong Geol;Lee, Sang Ryong
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.725-743
    • /
    • 2000
  • This study was intended to investigate the contents associated with the neuropsychosis in the medical books published in the times of Chinese dynasty of Jin and Yuan. As a result, the following findings were drawn. 1. As for palpitation from fright and severe palpitation, the medical schools in the times of Chinese Jin and Yuan dynasties viewed their causes as heart-fire, shuiqichengxin, blood vacuity, phlegm and so on and presented a prescription for each cause for them. 2. As for psychosis, medical books published in the times of Chinese Jin and Yuan dynasties accurately divided and discussed epilepsy and viewed their causes largely as Yangming heat, phlegm of chest and heart-fire. And a number of medical schools made use of such therapeutics as sweating, vomiting and diarrhea therapies. 3. As for headache, medical books published in the times of Chinese Jin and Yuan dynasties presented their causes as fire and heat, phlegm heat, phlegm and so on and classified the aspect of headache in detail. As for vacuity rexation and dysphoria, medical books at that time saw their causes as fire and heat, heart-fire, blood vacuity and so forth and presented a prescription for them accordingly. 4. Liu Wan Su was the Hanliang school. He viewed the etiological cause for psychopathy as fire and heat and prescribed largely the medication of cold nature for it. 5. Zhang Cong Zheng belonged to the Gongxia School. He viewed the etiological cause for psychopathy as fire, phlegm and so forth and made use of sweating, vomiting and diarrhea therapies. Especially, he used the 'Jingzhepingzhe' therapy as a method to treat the symptom of fright. 6. Li Gao did not any specific mention of psychopathy and divided headache due to internal injury and headache due to external contraction. 7. Zhu Zhen Heng viewed most of the etiological causes for psychopathy as phlegm, fire and deficiency of blood and attached importance to such its therapeutics as resolving phlegm, cleaning away fire and nourishing Yin. 8. Wang Hao Gu did not present the specifically common etiological cause and prescription for psychopathy but described the cause and prescription for headache, dysphoria, maniac speech, palpitation and so forth. Luo Tian Yi presented the process of psychosis due to abnormal therapy for cold demage and prescription of it. 9. Wang Lu made a detailed explanation about the therapeutics of five types of stagnated syndrome and said that stagnated syndrome became the major cause for them in the occurrence of such psychopathy. Wei Yi Lin presented the prescription and medication for comparatively diverse mental diseases such zhong-qi, severe palpitation, palpitation for fright, impaired memory, vacuity rexation, headache, psychosis.

  • PDF

Convergent Study on Microbial Contamination of Toothbrushes According to Intraoral Bacteria Acidogenicity and Toothbrush Care (구강내 세균의 산생성도와 칫솔 관리법에 따른 칫솔 세균 오염에 관한 융합연구)

  • Park, Young-Nam;Ryu, Jae-ki
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.223-228
    • /
    • 2020
  • Objective of this study was to compared the amount of bacteria in the toothbrush according to the management method of the toothbrush in use and the acidity of intraoral bacteria. Toothbrushes in use in more than one month of 50 healthy adults were collected and the number of bacteria and pH of the toothbrushes were measured. When the number of brushings per day was 4, the pH 4.97 and the microbial numbers was the lowest at 42.16(104×CFU/ml). When the replacement period of the toothbrush was 1 month, the pH 5.35 and the microbial numbers was the lowest at 19.80(104×CFU/ml). When stored in the bathroom, the pH 4.78, and the microbial numbers was highest at 149.46(104×CFU/ml). As a result, in order to block the germs of the toothbrush, it is necessary to develop a method that can easily disinfect the contaminated toothbrush at home. In addition, I think that it is necessary to educate about the proper brush cleaning and storage method when teaching brushing.

Effect of Ultrasonic Pretreatment on Analysis of Potassium Ion in Human Urine Using 15-Crown-5-Anthracene-based Membrane (15-Crown-5-Anthracene 막을 이용한 요 중의 칼륨이온 분석에 미치는 초음파 전처리의 효과)

  • Lee, Ji-Young;Chang, Hye-Young;Bae, Zun-Ung
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.1
    • /
    • pp.13-18
    • /
    • 2003
  • The effect of ultrasonic decomposition was introduced to develop a pretreatment method for the analysis of potassium ion in human urine by potentiometry. N-(4’-benzo-15-crown-5)-anthracene-9-imine, which has a good selectivity coefficient for potassium against ammonium, was used as an ion-selective material for the determination of potassium in urine with relatively high concentration of $NH_4{^+}$. Protenis in urine be removed by 85.1% when the sample acidified with 1.0 M $HNO_3$ was preteated for 100 s by sonication. Potential response of the membrane electrode in the pretreated urine had a slope of 54.6(${\pm}0.2,\;n=5$) mV/decade over the linear range of log $[K^+]$=-5~-1(r=0.9997). When an oxidant, $H_2O_2$, was addwd to the urine sonicated with $HNO_3$, the deproteinization increased 10% more than that in case if only $HNO_3$ and then the maximum ratio of ca. 95% was obtained. Moreover, the Nernstian slope for $K^+$ added to the urinary sample increased to 56.7(${\pm}0.1,\;n=3$) mV/decade. When the calibration curves were measured, the slopes did not vary even after the electrode was successively used 20 times with ultrasonic cleaning. The results showed that an ultrasonic pretreatment method provides simplicity in use, reduced treatment time and improved potentiometric characteristics of the membrane as the method effectively removes ca. 95% of proteins in urine.

Hydrologic and Environmental Assessment of an Infiltration Planter for Roof Runoff Use (지붕 빗물이용을 위하여 개발된 침투화분의 환경·수문학적 평가)

  • Moon, So-Yeon;Choi, Ji-Yeon;Hong, Jung-Sun;Yu, Gi-Gyung;Jeon, Je-Chan;Flores, Precious Eureka D.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • Due to urbanization and increase in impervious area, changes in natural water circulation system have become a cause of groundwater recharge reduction, streamflow depletion and other hydrological problems. Therefore, this study developed the infiltration planter techniques applied in an LID facility treating roof stormwater runoff such as, performance of small decentralized retention and infiltration through the reproduction of natural water circulation system and use of landscape for cleaning water. Assessment of an infiltration planter was performed through rainfall monitoring to analyze the water balance and pollutant removal efficiency. Hydrologic assessment of an infiltration planter, showed a delay in time of effluent for roof runoff for about 3 hours and on average, 79% of facilities had a runoff reduction through retention and infiltration. Based on the analysis, pollutant removal efficiency generated in the catchment area showed an average of 97% for the particulate matter, 94% for the organic matter and 86-96% and 92-93% for the nutrients and heavy metals were treated, respectively. Comparative results with other LID facilities were made. For this study, facilities compared the SA/CA to high pollutant removal efficiency for the determination to of the effectiveness of the facility when applied in an urban area.