• Title/Summary/Keyword: Cleaning power

Search Result 280, Processing Time 0.034 seconds

Charicteristics of HF 10-cm Type Grid Ion Source for Inert and Chemically Reactive Gases.

  • Chol, W.K;Koh, S.K;Jang, H.G;Jung, H.J;Kondranin, S.G.;Kralkina, E.A.;Bougrov, G.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1996.02a
    • /
    • pp.102-102
    • /
    • 1996
  • This paper represents a new type low power High Frequency technological ion source (HF TIS) for ion - beam processing: the surface modification of materials, cleaning of surface, sputtering, coating of thin films, and polishing. The operational principle of HF TIS is based on the excitation of electrostatic waves in plasma located in the external magnetic field. Low power HF TIS with diameter 92 rom gives the opportunity to obtain beams of inert and chemically reactive gases with currents range from 5 to 150 mA (current density $0.015\;~\;3.5\;mA/\textrm{m}^2$) and ion beam energy 100 ~ 2500 eV at a HF power level 10 ~ 150 W. Three grid concave type ion optical system (IOS) is used for extraction and formation ofion beam.n beam.

  • PDF

Development of the Quick Exhaust Valve to Blowing the Intake Filter for the Thermal Power Plant (화력발전소 흡입필터 세정용 급속 배기 밸브의 개발)

  • Jeong, C.S.;Lee, H.U.;Jeong, Y.M.;Lee, C.D.;Yang, S.Y.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.548-552
    • /
    • 2010
  • The air suction filter of the power plant decrease the dust and impurities of suction air that reduce the life and efficiency of the boiler. The suction efficiency of the air filter falls with the dust and impurities when the time of use comes to be long. Therefore, the various contaminant of the filter must remove periodically. This paper presents a developed quick exhaust valve to use in the thermo-electric power plant. to removing contaminants on the filter, the blowing is done shortly by air pressure. The Air flowed out to the out side from the inside of the filter. The performance test of the developed valve is done by making a test-bench according to JIS and KS standards. The efficiency is found higher than the existing related valve.

TEM Analysis of Interfaces between Cr Film Sputtered with RE Bias and Photosensitive Polyimide (RE 바이어스 스퍼터링한 Cr 박막과 감광성 폴리이미드 사이의 계면 TEM 분석)

  • 조성수;김영호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.39-47
    • /
    • 2003
  • Cr thin films were deposited on photosensitive polyimide substrates by RF bias sputtering and DC sputtering and the interfaces between Cr thin film and polyimide were observed using TEM. When the polyimide surface was in-situ RF plasma cleaned at the RF power density of 0.13-2.12 $W/cm^2$, increasing of RF power density changed the morphology of polyimide surfaces from round dig to sharp shape, and surface roughness increased by anisotropic etching. The intermixed layer-like interfaces between Cr and polyimide were observed in the RF bias sputtered specimens. This interface seems to be formed due to the RF cleaning effect; the polyimide surface was RF plasma cleaned while RF power was increased to the setting point before Cr deposition.

  • PDF

Biosorption of uranium by Bacillus sp.FB12 isolated from the vicinity of a power plant

  • Xu, Xiaoping;He, Shengbin;Wang, Zhenshou;Zhou, Yang;Lan, Jing
    • Advances in environmental research
    • /
    • v.2 no.3
    • /
    • pp.245-260
    • /
    • 2013
  • Biosorption represents a technological innovation as well as a cost effective excellent remediation technology for cleaning up radionuclides from aqueous environment. In the present study, a bacteria strain FB12 with high adsorption rate of uranium ion was isolated from the vicinity of the nuclear power plant. It was tentatively identified as Bacillus sp.FB12 according to the 16S rDNA sequencing. Efforts were made to further improve the adsorption rate and genetic stability by UV irradiation and UV-LiCl cooperative mutagenesis. The improved strain named Bacillus sp.UV32 obtains excellent genetic stability and a high adsorption rate of 95.9%. The adsorption of uranium U (VI) by Bacillus sp.UV32 from aqueous solution was examined as a function of metal ion concentration, cell concentration, adsorption time, pH, temperature, and the presence of some foreign ions. The adsorption process of U (VI) was found to follow the pseudo-second-order kinetic equation. The adsorption isotherm study indicated that it preferably followed the Langmuir adsorption isotherm. The thermodynamic parameters values calculated clearly indicated that the adsorption process was feasible, spontaneous and endothermic in nature. These properties show that Bacillus sp.UV32 has potential application in the removal of uranium (VI) from the radioactive wastewater.

The Performance Analysis of a Counter-rotating Tubular Type Turbine with the Number of Runner Vane (러너베인 깃수의 변화에 따른 튜블러형 상반전 수차의 성능해석)

  • Park, Jihoon;Lee, Nakjoong;Hwang, Youngho;Kim, Youtaek;Lee, Youngho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.192.1-192.1
    • /
    • 2010
  • Micro hydraulic turbines take a growing interest because of its small and simple structure as well as high possibility of applying to micro and small hydropower resources. The differential pressure exiting within the city water pipelines can be used efficiently to generate electricity like the energy generated through gravitational potential energy in dams. In order to reduce water pressure at the inlet of water cleaning centers, pressure reducing valves are used widely. Therefore, pressure energy is wasted. Instead of using the pressure reduction valve, a micro counter-rotating hydraulic turbine can be replaced to get energy caused by the large differential pressure found in the city water pipelines. In this paper, detail studies have been carried out to acquire basic design data of micro counter-rotating hydraulic turbine, output power, head, and efficiency characteristics on various number of runner vane. Moreover, the influences of pressure, tangential and axial velocity distributions on turbine performance are also investigated.

  • PDF

Preparation of Solvent-Free Low Foaming Scouring Agents and Their Scouring Characteristics (무용제형 저기포성 정련제의 제조 및 정련특성)

  • Park, Hong-Soo;Ahn, Sung-Hwan;Shim, Il-Woo;Jo, Hye-Jin;Hahm, Hyun-Sik;Kim, Yeoung-Chan;Kim, Seong-Kil
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.37-44
    • /
    • 2006
  • Solvent-free low foaming scouring agents (LFSC) were prepared by blending of 2-ethylhexylaminoethyl sulfate (2-EHAS), POE(10) octadecylbenzyl- ammonium chloride (POBAC) and Sedlan FF-200 (FF-200). As the results of several tests, 2-EHAS/POBAC/FF-200/water (8g/12g/20g/60g) mixture (LFSC-5) showed good cleaning power, penetrating ability and stability to alkali, and gave less problem in water pollution. The foaming power of LFSC-5 measured by Ross and Miles method was 8mm foam height immediately after foaming, and that measured by Ross and Clark method was less than 300mm foam height at $30^{\circ}C$, and 18mm at $80^{\circ}C$. As a result, LFSC-5 proved a good low foaming scouring agent for fiber.

Prediction of Cleaning Time of Desulfurization Absorber in a Oil-Fired Power Plant through the Operation Data (중유화력발전소의 운전자료를 이용한 탈황 흡수탑의 세정시기 예측)

  • Jang, Yeong-Gi;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.4
    • /
    • pp.38-46
    • /
    • 2015
  • 중유를 연소하는 D 발전소 탈황설비는 운전시간의 경과에 따라 흡수탑 중간층에 석고가 쌓이고 가스분사 파이프 내에 경질석고 스케일이 부착됨으로써 발전설비 및 탈황설비의 정상적인 운전이 어렵게 된다. 흡수탑 내부에 발생된 스케일을 제거하지 않을 경우에는 탈황효율의 저하에 따른 SO2 배출농도의 증가로 발전가능 최대출력의 하향조정이 발생되고 나아가 발전정지를 초래한다. 스케일 제거를 위한 탈황설비 세정은 발전가능 최대출력의 하향조정이 발생하는 시점으로 결정할 수 있다. 본 연구에서는 탈황설비의 운전 자료를 분석하여 발전가능 최대출력의 하향조정이 발생되기 6주 전은 탈황설비 출구 SO2 농도값이 130ppm을 초과하고 동시에 흡수탑 차압은 380mmH2O을 초과하며, 직전 흡수탑 세정 이후 44주가 경과된 시점이 됨을 확인하였다. 그리고 흡수탑의 세정시기는 세정준비기간 6주와 발전가능 최대출력 하향이 발생되기 6주 전까지의 운전경과일수 44주를 더하여 직전 세정시점으로부터 50주가 경과된 시점임을 예측하였다.

  • PDF

Experiments on Slip Coefficients of High-Strength Bolt Connection with Weathering Steel (I) (내후성강재 고장력볼트 이음부 미끄럼계수 평가 실험 (I))

  • Park, Yong Myung;Seong, Taek Ryong
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.167-175
    • /
    • 2000
  • An experimental research to evaluate the slip coefficient of high-strength slip-critical-type bolt connection of weathering steel plate has been performed in this paper. Experiments were performed with several surface conditions such as clean mill scale with hand or power brush cleaning, shot blast cleaned, inorganic zinc primer coated, and weather coated surfaces. Also, the relaxation of bolt clamping force was estimated during 500 hours. It was ascertained from the experiments that slip coefficients are greater than 0.40 in all faying surface conditions except mill scale surface with power brushing. The quantify of relaxation depended on the surface conditions and was $3{\sim}8%$, i.e., less than 10%.

  • PDF

An Input-Output Analysis on the Korean Railway Industry with the 2003 Input-Output Tables (2003 산업연관표를 이용한 철도운송산업의 경제적 파급효과 분석)

  • Yoon, Jae-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.4
    • /
    • pp.410-416
    • /
    • 2008
  • The inter-industrial inducement effects of the korean railway services on the output, value-added, imports of the 403 industrial sectors of the korean economy have been computed by the input-output analysis technique utilizing the 2003 Input-Output Tables, which was published most recently in April 2007 by the Bank of Korea. The korean railway service industry produced \2,766 billion worth of passenger and freight railroad services in the 2003 year, and it has induced \1,701 billion worth of output, \781 billion worth of value-added, and \580 billion worth of imports of the korean industry as a whole. The energy sector industries such as diesel fuel, thermal power generation, nuclear power generation, crude oil, liquid natural gas, bituminous coal, liquid propane gas have been most affected by the korean railway services. Other industries mainly affected by the korean railway services include railroad car manufacturing, cleaning and decontamination, medical and health service, machinery equipment and rental, construction and maintenance, transportation related services, business R&D, property insurance, and telecommunication.

Laser beam decontamination of metallic surfaces with a pulsed (150 W) Nd: YAG laser

  • Anne-Maria Reinecke;Margret Acker;Steffen Taut;Marion Herrmann;Wolfgang Lippmann;Antonio Hurtado
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4159-4166
    • /
    • 2023
  • Laser decontamination of radioactive surfaces is an innovative technology. Our contribution to improving this technology includes studies on laser beam decontamination with a pulsed laser of an average power of 150 W, equipped with a hand guided working head. Our investigations are focused on metallic surfaces typical in nuclear power plants, such as stainless steel, bright and rusted mild steel, galvanized steel, and painted steel. As typical nuclides of contaminated surfaces we chose Co-60 and Cs-137, the most frequently occurring nuclides in many nuclear plant components; Sr-85 as a representative of Sr-90, the potentially most harmful fission nuclide; and Am-241 as a representative of the minor alpha-radiation emitting actinides. Here, we present our results of decontamination and recovery ratios. Decontamination ratios of 90-100% were achieved on different surfaces.