• Title/Summary/Keyword: Cleaning evaluation

Search Result 245, Processing Time 0.029 seconds

Evaluation of Material Durability by Identifying the Relationship between Contact Angle after Wear and Self-cleaning Effect Using Rolling Wear Tester (구름 마모시험 장비(Rolling wear tester)를 이용한 마모 후의 접촉각과 자가세정 효과와의 관계 규명을 통한 재료 내구성 평가)

  • Kyeongryeol Park;Yong Seok Choi;Seongmin Kang;Unseong Kim;Kyungeun Jeong;Young Jin Park;Kyungjun Lee
    • Tribology and Lubricants
    • /
    • v.39 no.6
    • /
    • pp.256-261
    • /
    • 2023
  • This study is conducted to evaluate the durability of superhydrophobic surfaces, with a focus on two aspects: contact angle measurement and self-cleaning-performance analysis. Superhydrophobic copper and aluminum surfaces are fabricated using the immersion method and subjected to a rolling wear test, in which a 2 kg weight is placed on a rolling tester, under loaded conditions. To evaluate their durability, the contact angles of the specimens are measured for each cycle. In addition, the surface deformation of the specimens before and after the test is analyzed through SEM imaging and EDS mapping. The degradation of the self-cleaning performance is evaluated before and after the wear test. The results show that superhydrophobic aluminum is approximately 4.5 times more durable than superhydrophobic copper; the copper and aluminum specimens could endure 21,000 and 4,300 cycles of wear, respectively. The results of the self-cleaning test demonstrate that superhydrophobic aluminum is superior to superhydrophobic copper. After the wear test, the self-cleaning rates of the copper and aluminum specimens decrease to 72.7% and 83.4%, respectively. The relatively minor decrease in the self-cleaning rate of the aluminum specimen, despite the large number of wear cycles, confirms that the superhydrophobic aluminum specimen is more durable than its copper counterpart. This study is expected to aid in evaluating the durability of superhydrophobic surfaces in the future owing to the advantage of performing wear tests on superhydrophobic surfaces without damaging the surface coating.

Optimal Flow Rate Evaluation for Low Energy, High Efficiency Cleaning of Forward Osmosis (FO) (정삼투 공정의 저에너지 고효율 세정을 위한 최적 유속 평가)

  • Kim, Yihyang;Kim, Jungbin;Zhan, Min;Min, Dahae;Hong, Seungkwan
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.339-347
    • /
    • 2019
  • Forward osmosis (FO) is operated at a lower pressure than reverse osmosis (RO), which has great advantages in terms of fouling control, maintenance, membrane cleaning, and potential energy reduction. In particular, since the membrane fouling layer of the forward osmosis process has a relatively loose and dispersed property, it is possible to control the membrane fouling by physical cleaning, unlike the reverse osmosis process. However, existing studies do not apply the proper cleaning flow rate for forward osmosis physical cleaning, and thus there is a limit that the optimal operation can not be performed. Therefore, this study aims to evaluate the justification of proper flow rate that can show high efficiency cleaning with economical energy amount. The membrane fouling experiments of the forward osmosis process were maintained at a circulating flow rate of 8.54 cm/s and the recovery rates were compared with the three cleaning flow rates. As a result of this experiment, it was confirmed that the 2 × speed cleaning showed the same efficiency as the water permeability recovery rate of the 3 × speed cleaning, and it was confirmed that the 2 × speed cleaning was an appropriate flow rate with high cleaning efficiency and economical SEC.

A Study on the Applicability of $C_5$ Hydrofluoroether-based Formulated Cleaning Agents as CFC-Alternatives ($C_5$계 수소불화에테르를 기반으로 하는 배합 세정제의 CFC 대체세정제 적용 연구)

  • Min, Hye-Jin;Bae, Jae-Heum;Chang, Yoon-Sang
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.172-181
    • /
    • 2010
  • Hydrofluoroethers (HFEs) with fluoride molecules in their structure which are evaluated as the third generation replacement alternatives to chlorofluorocarbons (CFCs) are known to be excellent for removal of nanoparticles and fluoride-type soils due to their low surface tension and high wetting index. In addition, HFEs have good physical properties with no flash point and excellent drying characteristics. But, HFEs also have shortcomings in that they are not effective for removal of organic soils due to their poor solubility in soil. In this study, $C_5$ HFE-based cleaning agents were formulated through addition of solvents such as isopropyl alcohol (IPA), ethyleneglycol monoether (EG), propyleneglycol monoethylether (PM) to HFE-7100 [$CF_3CF_2CF_2CF_2OCH_3$] or HFE-mec-f [$CF_3CHF=CF_2OCH_2CF_3$] with its maximum amount, respectively, in order to have no flash point for the safety in the working environment. These solvents are known to be excellent for dissolving organics in soil. Their physical properties and cleaning abilities for fluxes, water-insoluble cutting oils, and fluoride-type oils were evaluated and compared with those of other cleaning agents with single components. The experimental results show that the HFE-based formulated cleaning agents have various good physical properties which are almost similar to those of a single type of HFE cleaner. They show excellent cleaning ability for fluxes, water-insoluble cutting oils, and fluoride-type oils. These results indicate that the HFE-based formulated cleaning agents can be applicable to various industrial cleaning fields because of their good physical properties and cleaning abilities for various soils.

Automatic Feeding Bottle Washing Machine Usability Evaluation : Infant Product (자동 젖병 세척기 사용성평가 : 영유아 제품)

  • Park, Hye Jin;Kim, Jong Geun;Lee, Seok Jae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.507-514
    • /
    • 2022
  • This study is to compare and analyze the evaluation of cleaning cleanliness and usability according to the muscle activity and cleaning method in the wrist rotation motion when using a bottle washer for women with childbirth experience. To this end, when using an automatic bottle washer and a manual bottle washer, the muscle activity and cleaning cleanliness of the forearm muscles were quantitatively evaluated using equipment, and the effects of variables were analyzed and the following conclusions were obtained. First, it was found that the muscle activity was lower than that of the automatic baby bottle cleaner when using a manual bottle cleaner. Second, the cleanliness was judged to be the best in automatic washing (forward + reverse direction), followed by automatic washing (forward direction) and manual washing. Third, the usability evaluation of the use of the baby bottle washing machine showed higher satisfaction than that of the automatic baby bottle washing machine. Through these conclusions, this study can be used as basic data for product advancement in the future by proving the effectiveness of using an automatic bottle washer.

An Evaluation of Exposure to Petroleum Based Dry Cleaning Solvent Used in Commercial Dry Cleaning Shops (석유계 솔벤트를 사용하는 세탁소 작업자의 노출평가)

  • Jeong, Jee Yeon;Yi, Gwang Yong;Lee, Byung kyu;Lee, Naroo;Kim, Bong Yeon;Kim, Kwang Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • In previous report, we presented that petroleum based solvents used in dry cleaning shop was almost similar to stoddard solvent defined by ACGIH and NIOSH, and the occupational exposure standard of stoddard solvent could be used in total exposure assessment of those solvents. The specific aim of the this study was to evaluate of the solvent exposure used in commercial dry cleaning shops by using occupational exposure standard of stoddard solvent. We conducted first survey of 8 self-employed dry cleaning shops and 5 factory type dry cleaning shops from July to August, and second survey of the same shops from October to November in 2002. The exposure concentration to the solvent during loading and unloading activity of vented dry cleaning machine was 489.2ppm(GM), 270.3ppm(GM), respectively, which was almost excursion limit(500ppm) of ACGIH, and exceed the ceiling limit(312ppm) of NIOSH. The time-weighted average (TWA) worker exposure to the solvent was 21.3ppm(GM) at self-employed shops, 20.7ppm(GM) at factory type shops on first survey, and 31.1ppm(GM), 33.7ppm(GM), respectively on second survey. The TWA exposure concentration of workers with spotting and cleaning machine operating job was 25.4ppm(GM), which was 2.9 times higher than the TWA exposure concentration, 8.8ppm(GM) of press workers. All TWA exposure concentrations was lower than OEL(100ppm) of stoddard solvent. We found that the most heavy exposure process at dry cleaning was loading, unloading process, and the vent of dry cleaning machine was the main emission source for workers exposure to petroleum based solvent.

A Study of Cleaning Technology for Zirconium Scrap Recycling in the Nuclear Industry (원자력산업에서 지르코늄 스크랩 재활용을 위한 세정기술에 관한 연구)

  • Lee, Ji-Eun;Cho, Nam-Chan;An, Chang-Mo;Noh, Jae-Soo;Moon, Jong-Han
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.264-271
    • /
    • 2013
  • In this study, we optimized the removal condition of contaminants attached on the scrap surface to recycle the scrap generated from the Zr alloy tube manufacturing process back to the nuclear grade. The main contaminant is remnant of watersoluble cooling lubricant that is used in the pilgering manufacture during the tube production, and it is assumed to be compressed and carbonized on the surface of tube. Zirlo alloy tube of ${\phi}9.50mm$, which has high occurrence frequency of scrap, was selected as the object to be cleaned, and cleaning abilities of reagents were evaluated by measuring the characteristics of contaminants remained and by analyzing the surface of the tube after cleaning process. For evaluation of each cleaning agent, we selected two types of sodium hydroxide series and three types of potassium hydroxide series. Furthermore, to confirm dependence on tempe-rature and ultrasonic intensities, cleaning at the room temperature, $40^{\circ}C$, and $60^{\circ}C$ was conducted, and results showed that higher the cleaning temperature and higher the ultrasonic intensity, better the cleaning effect. As a result of the bare-eye inspection, while the use of sodium hydroxide provided satisfactory condition on the tube surface, the use of potassium hydroxide series provided satisfactory condition on the tube surface only when the ultrasonic intensity was over 120 W. In the cleaning effect analysis using the gravimetric method, cleaning efficiency of sodium hydroxide series was as high as 97.6% ($60^{\circ}C$, 120 W), but since the tube surface condition was poor after the use of potassium hydroxide, the gravimetric method was not appropriate. In the analytical result of surface contaminants on the tube surface, C, O, Ca, and Zr were detected, and mainly C and O dominated the proportion of contaminants. It was also found that the degree of cleaning on the tube affected the componential ratio of C and O; if the degree of cleaning is high, or if cleaning is well-conducted, the proportion of C is decreased, and the proportion of O is increased. Based on these results, optimal cleaning for application in the industry can be expected by categorizing cleaning process into three steps of Alkali cleaning, Rinsing, and Drying and by adjusting cleaning parameters in each step.

Applicability evaluation of microbubble for membrane fouling reduction in wastewater reuse membrane process (하수재이용 막여과 공정에서 막오염 저감을 위한 마이크로버블 적용성 평가)

  • Lee, Chang-Ha;Kim, Geon-Youb;Kim, Hyung-Soo;Kim, Ji-Hoon;Lee, Kyung-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.169-175
    • /
    • 2017
  • This study applied microbubbles to reduce membrane fouling in wastewater reuse membrane processes, evaluated and compared the transmembrane pressure with or without the application of microbubbles and the cleaning efficiency with the application of aeration and microbubbles. In addition, this study analyzed foulants removed from the membrane surface. Changes in the transmembrane pressure of membranes with the presence or absence of microbubbles were observed. As a result, transmembrane pressure (TMP) increasing rate decreased twofold when applying microbubbles to realize stable operations. This study compared and evaluated cleaning efficiency applying aeration and microbubbles. As a result, the cleaning efficiency was 5% higher on average when applying microbubbles. In turbidity and total organic carbon (TOC), foulants were discharged when applying microbubbles twice as much as applying aeration. It is thought that particulate foulants precipitated on the membrane surface were more likely to desorb because the adhesion between the membrane surface and particle was weakened by microbubbles. Therefore, it is considered possible to effectively control membrane fouling because of the increase in cleaning efficiency when applying microbubbles to wastewater reuse membrane processes.

Evaluation of Self-Cleaning Performance of Mortar Using Nano-Titanium Dioxide Photocatalytic Coating (나노 이산화티탄 광촉매 코팅을 적용한 모르타르의 자기정화성능 평가)

  • Yang, In-Hwan;Jeon, Hyo-Jin;Lee, Seung-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.56-65
    • /
    • 2022
  • This paper aims at estimating self-cleaning performance of mortar coated with photocatalytic suspension under various conditions. Experimental variables included the concentration (1.5 % and 3.0 %) of photocatalytic suspension for coating mortar specimen, the presence of hydrophilic agent in photocatalytic suspension, and applying the primer on the surface of mortar. The color change of methylene blue solution increased and accordingly self-cleaning performance increased as photocatalytic concentration increased. The presence of hydrophilic agent in photocatalytic suspension slightly decreased the self-cleaning performance compared to the conventional photocatalytic suspension. Test results also showed that mortar specimen including primer and specimen not including primer did not show significantly different self-cleaning performance. In addition, cracks on the surface of mortar specimens decreased as the photocatalytic concentration increased. Therefore, increase in cracks on the surface of mortar at different photocatalytic concentration might adversely affect the self-cleaning performance of mortar specimens.

Thermo-responsive antifouling study of commercial PolyCera® membranes for POME treatment

  • Haan, Teow Yeit;Chean, Loh Wei;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.97-109
    • /
    • 2020
  • Membrane fouling is the main drawback of membrane technology. Frequent membrane cleaning and membrane replacement are, therefore, required to reduce membrane fouling that causes permeate flux reduction, lower rejection, or higher operating pressure. Studies have proved that the alteration of membrane properties is the key controlling factor in lessening membrane fouling. Among stimuli-responsive membranes, thermo-responsive membrane is the most popular, with a drastic phase transition and swelling-shrinking behavior caused by the temperature change. In this study, the thermo-responsive ability of two commercial membranes, PolyCera® Titan membrane and PolyCera® Hydro membrane, at different temperatures was studied on the antifouling function of the membrane in palm oil mill effluent (POME) treatment. The evaluation of the membrane's thermo-responsive ability was done through three cycles of adsorption (fouling) and desorption (defouling) processes in a membrane filtration process. The experimental result depicted that PolyCera® Hydro membrane had a higher membrane permeability of 67.869 L/㎡.h.bar than PolyCera® Titan membrane at 46.011 L/㎡.h.bar. However, the high membrane permeability of PolyCera® Hydro membrane was compensated with low removal efficiency. PolyCera® Titan membrane with a smaller mean pore size had better rejection performance than PolyCera® Hydro membrane for all tested parameters. On the other hand, PolyCera® Titan membrane had a better hydrodynamic cleaning efficiency than PolyCera® Hydro membrane regardless of the hydrodynamic cleaning temperature. The best hydrodynamic cleaning performed by PolyCera® Titan membrane was at 35℃ with the flux recovery ratio (FRR) of 99.17 ± 1.43%. The excellent thermo-responsive properties of the PolyCera® Titan membrane could eventually reduce the frequency of membrane replacement and lessen the use of chemicals for membrane cleaning. This outstanding exploration helps to provide a solution to the chemical industry and membrane technology bottleneck, which is the membrane fouling, thus reducing the operating cost incurred by the membrane fouling.

A Study of Purity-based Page Allocation Scheme for Flash Memory File Systems (플래시 메모리 파일 시스템을 위한 순수도 기반 페이지 할당 기법에 대한 연구)

  • Baek, Seung-Jae;Choi, Jong-Moo
    • The KIPS Transactions:PartA
    • /
    • v.13A no.5 s.102
    • /
    • pp.387-398
    • /
    • 2006
  • In this paper, we propose a new page allocation scheme for flash memory file system. The proposed scheme allocates pages by exploiting the concept of Purity, which is defined as the fraction of blocks where valid Pages and invalid Pages are coexisted. The Pity determines the cost of block cleaning, that is, the portion of pages to be copied and blocks to be erased for block cleaning. To enhance the purity, the scheme classifies hot-modified data and cold-modified data and allocates them into different blocks. The hot/cold classification is based on both static properties such as attribute of data and dynamic properties such as the frequency of modifications. We have implemented the proposed scheme in YAFFS and evaluated its performance on the embedded board equipped with 400MHz XScale CPU, 64MB SDRAM, and 64MB NAND flash memory. Performance measurements have shown that the proposed scheme can reduce block cleaning time by up to 15.4 seconds with an average of 7.8 seconds compared to the typical YAFFS. Also, the enhancement becomes bigger as the utilization of flash memory increases.