• Title/Summary/Keyword: Cleaning Effect

Search Result 627, Processing Time 0.024 seconds

A Study on the Cleaning Efficiency using the d-Limonene Oil Extracted in Wasted Mandarin Peels (폐감률피에서 추출한 limonene 오일의 세정성에 관한 연구)

  • Song, Min-Kyung;Oh, Eun-Ha;Im, Ho-Sub;Kim, Yoon-Shin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2010
  • The object of this research is to conform of practicable possibility and recycling of producing junk after citrus fruits is processed. With extracting d-limonene oil that have 70~90% a component of oil out of junk citrus peel, making certain the about 12000ppm concentration of it. Limonene derived from citrus in jeju using conventional synthetic detergents can be replaced with the development of environmentally friendly natural detergent investigated the possibility. Mostly due to ocean dumping, disposal and cause environmental problems by recycling natural citrus cleaner alternative to the research conducted on the possibility. Cleaning efficiency with temperature did not affect the largest concentrations were able to identify the difference between cleaning efficiency. At least 10% of the d-limonene oil could be from the cleaning performance, increasing the concentration of the cleaning efficiency was increased in size. Ultrasonic is very high removal efficiency under the conditions shown in the cause of pure self-generated ultrasonic cleaning power as co-effects of d-limonene oil appears to chemical cleaning effect of ultrasonic cavitation occurs in the physical cleaning effect due to a combination of synergistic stability is maximized by low concentrations of d-limonene oil in a short time showed an excellent cleaning ability. Having the ability of cleaning at the same time, considering the side recycling in the junk citrus peels reflects possibility of basic materials utility eco-friendly in the skin soap, bath soap, cosmetics etc, through ability of exclusion a contaminant in based cleaning effect(EC) it can prospect substitution effect environmentally in the pre existence synthetic detergents.

Effect of PVA Brush Contamination on Post-CMP Cleaning Performance (Post-CMP Cleaning에서 PVA 브러시 오염이 세정 효율에 미치는 영향)

  • Cho, Han-Chul;Yuh, Min-Jong;Kim, Suk-Joo;Jeong, Hae-Do
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.114-118
    • /
    • 2009
  • PVA (polyvinyl alcohol) brush cleaning method is a typical cleaning method for semiconductor cleaning process especially post-CMP cleaning. PVA brush contacts with the wafer surface and abrasive particle, generating the contact rotational torque of the brush, which is the removal mechanism. The brush rotational torque can overcome theoretically the adhesion force generated between the abrasive particle and wafer by zeta potential. However, after CMP (chemical mechanical polishing) process, many particles remained on the wafer because the brush was contaminated in previous post-CMP cleaning step. The abrasive particle on the brush redeposits to the wafer. The level of the brush contamination increased according to the cleaning run time. After cleaning the brush, the level of wafer contamination dramatically decreased. Therefore, the brush cleanliness effect on the cleaning performance and it is important for the brush to be maintained clearly.

Cleaning Fabricated Metal Thread: A Post-treatment Stability Assessment after Artificial Deterioration and the Application of Synthetic Soil

  • Park, Hae Jin;Hwang, Minsun;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.19-31
    • /
    • 2019
  • To study the cleaning effects and post-treatment stability assessment of various methods of cleaning textiles with metal thread, six naturally-soiled historical textiles with metal thread were investigated at the Metropolitan Museum of Art, New York. Prior to the cleaning of fabricated gold, silver, and copper thread that had been glued onto a paper substrate, the artificial deterioration was carried out in a controlled environment with light(UV and daylight), and temperature and humidity factors which would weaken and damage the samples. A synthetic soil mixture was applied to the samples to imitate soil found on the historic and archaeological textiles with metal thread; the cleaning effect and post-treatment assessment were investigated by use of three textile cleaning methods: mechanical cleaning, wet cleaning, and solvent cleaning. While investigating the naturally-soiled textiles with metal thread, it was determined that the soil colors and sizes of contaminating particles of each textile were different due to the diversity of original environmental factors and conditions. After cleaning with kneaded rubber, Stoddard solvent, n-decane or n-hexane, a bright, clean effect was apparent. Kneaded rubber was successful in picking up both large and small particles, but its stickiness caused some of the metal leaf to peel off. Stoddard solvent produced a good cleaning effect, but after use of n-hexane and n-decane in the cleaning process, a white layer of residue remained on the textile's surface. Wet cleaning was not effective and the rapid humidity changes between wet and dry conditions caused the edges of the paper substrate to lose their original shape.

Enzymatic Cleaning of Ultrafiltration Membrane Fouled with a Semi-synthetic Type Cutting Oil

  • Chung, Kun-Yong;Lee, Jeung-Bok;Chang, Pahn-Shick
    • Korean Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.60-63
    • /
    • 2000
  • The effect of Candida rugosa and steapsin lipase cleaning was investigated for ultrafiltration polyethersulphone membrane (30,000 dalton MWCO) fouled with the semi-synthetic type cutting oil. The experimental by the water circulator. The enzyme cleaning effect was measured with respect to temperature, cleaning time and enzyme concentration. The optimum cleaning condition for the system was 25$^{\circ}C$ and 2 hour cleaning with 1,000 unites/mL steapsin solution. The pure water flux improvement by the steapsin solution cleaning was about 17% at the optimum cleaning condition.

  • PDF

Effect of Road Sweeping on the Abatement of Runoff Pollution Loads from in the Highway (고속도로 노면 청소에 따른 강우시 유출오염부하 저감 효과 분석)

  • Kang, Heeman;Lee, Doojin;Yoon, Hunsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.851-860
    • /
    • 2012
  • In this study, to evaluate the abatement of runoff pollution loads by the road sweeping(cleaning), various investigations are implemented at the sample area of the highway. As the results of evaluating the removal efficiency of pollutants along road cleaning, TSS showed about 78 % of the removal efficiency and COD showed 49 % of removal efficiency through the operation of cleaning vehicle of vacuum suction method. In case of TN and TP, they showed the relatively-lower removal efficiency by 30~35 %. TSS removal efficiency along the number of cleaning appeared about 60 % in case of one time of cleaning and the additional removal effect did not appear though the number of cleaning increased to two times. With running speed of cleaning vehicle, TSS removal ratio is lessened from 60 % to 20 % when cleaning vehicle speed up to 20 km/hr from 6 km/hr. It seems that the reasons why the removal efficiencies are inversely proportional to its speed are related to the lower vacuum efficiencies and the disturbed particles on the road. In the pollutant build-up analysis, it is showed that it takes more time to the critical pollutant build-up in the shoulder than the center of the road. It is also showed that the proper cleaning cycle is recommended as 4~6 dry weather days without rainfall events.

Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments (고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향)

  • Kwon, Hyuk-chul
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.

Effect of Chemical Mechanical Cleaning(CMC) on Particle Removal in Post-Cu CMP Cleaning (구리 CMP 후 연마입자 제거에 화학 기계적 세정의 효과)

  • Kim, Young-Min;Cho, Han-Chul;Jeong, Hae-Do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1023-1028
    • /
    • 2009
  • Cleaning is required following CMP (chemical mechanical planarization) to remove particles. The minimization of particle residue is required with each successive technology generation, and the cleaning of wafers becomes more complicated. In copper damascene process for interconnection structure, it utilizes 2-step CMP consists of Cu and barrier CMP. Such a 2-steps CMP process leaves a lot of abrasive particles on the wafer surface, cleaning is required to remove abrasive particles. In this study, the chemical mechanical cleaning(CMC) is performed various conditions as a cleaning process. The CMC process combined mechanical cleaning by friction between a wafer and a pad and chemical cleaning by CMC solution consists of tetramethyl ammonium hydroxide (TMAH) / benzotriazole (BTA). This paper studies the removal of abrasive on the Cu wafer and the cleaning efficiency of CMC process.

The Study on Wafer Cleaning Using Excimer Laser (엑사이머 레이저를 이용한 웨이퍼 크리닝에 관한 고찰)

  • 윤경구;김재구;이성국;최두선;신보성;황경현;정재경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.743-746
    • /
    • 2000
  • The removal of contaminants of silicon wafers has been investigated by various methods. Laser cleaning is the new dry cleaning technique to replace wafer wet cleaning in the near future. A dry laser cleaning uses inert gas jet to remove contaminant particles lifted off by the action of a KrF excimer laser. A laser cleaning model is developed to simulate the cleaning process and analyze the influence of contaminant particles and experimental parameters on laser cleaning efficiency. The model demonstrates that various types of submicrometer-sized particles from the front sides of silicon wafer can be efficiently removed by laser cleaning. The laser cleaning is explained by a particle adhesion model. including van der Waals forces and hydrogen bonding, and a particle removal model involving rapid thermal expansion of the substrate due to the thermoelastic effect. In addition, the experiment of wafer laser cleaning using KrF excimer laser was conducted to remove various contaminant particles.

  • PDF

A Study on the Scientific Conservation of Buried-Fabrics form old Tombs -cleaning and ironing- (출토직물의 과학적 보존 처리에 관한 연구 -세탁방법과 다림질 방법-)

  • 배순화;이미식
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.987-997
    • /
    • 1999
  • The purpose of this study was finding out the appropriate cleaning method for buried fabrics from old tombs focusing on the conservation of textiles. Cleaning effects and physical properties change depending on cleaning method have been analysed, The following results were obtained from this study : 1. Wet cleaning showed better effect on the cleaning of fabrics compared to solvent cleaning which meant more water-soluble soils existed than oily soils. 2. All the cleaning methods used did not cause any distorsion or shrinkage to the fabrics because fabrics had been stabilized for a long time 3. Addition of detergent to cleaning system decreased the friction of fiber during cleaning rocess so that the damage of fabrics could be minimized., 4. Ironing is an undesirable process because heat remarkably weakened fibers.

  • PDF

Plasma Cleaning Effect for Improvement of Package Delamination (패키지 박리 개선을 위한 플라즈마 세정 효과)

  • Koo Kyung-Wan;Kim Do-Woo;Wang Jin-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.7
    • /
    • pp.315-318
    • /
    • 2005
  • The effect of plasma cleaning was examined on package delamination phenomena in the integrated circuit (IC) packaging process. Without plasma cleaning, delamination was observed for all three experimental treatments applied after the packaging step, which include bake of If, reflow, and bake of If followed by reflow However, no delamination was observed when the plasma cleaning was performed before and after the wire bonding step. Plasma cleaning was found to be a critical step to improve the reliability of the package by reducing the possibility of contact failure between die pad and bonding wire.