• Title/Summary/Keyword: Clavicle hook plate

Search Result 19, Processing Time 0.207 seconds

Acromion Fracture after Hook Plate Fixation for Distal Clavicle Injury: A Report of 2 Cases

  • Kang, Suk;Lee, Ho Min;Back, In Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.168-171
    • /
    • 2016
  • Fractures at the lateral end of the clavicle inevitably require surgical treatment as there is high potential for delayed union or nonunion. Acromioclavicular dislocation also requires stable and solid fixation for healing, and surgical treatment is recommended for the maintenance of joint function. The hook plate maintains the biomechanics of the acromioclavicular joint, enabling early range of motion. Therefore, for the past 10 years, the hook plate has been widely used in distal clavicle fractures and acromioclavicular joint injuries. However, the hook plate is associated with several complications, such as proximal clavicle fractures, widening of the hook hole, rotator cuff tear, subacromial impingement, and often acromial fractures. We report on two unusual cases of acromion fracture after hook plate fixation in patients with distal clavicle fracture and acromioclavicular dislocation alongside a literature review.

The Radiologic Comparison of Operative Treatment Using a Hook Plate versus a Distal Clavicle Locking Plate of Distal Clavicle Fracture

  • Yoon, Byungil;Kim, Jae Yoon;Lee, Jae-Sung;Jung, Hyoung Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.227-233
    • /
    • 2018
  • Background: The purpose of this study was to compare the radiologic results of patients who underwent surgery with a hook plate and a locking plate in distal clavicle fractures. Methods: Sixty patients underwent surgical treatment for Neer type IIa, IIb, III, and V distal clavicle fracture. Twenty-eight patients underwent fracture fixation with a hook plate and 32 with a locking plate. Coracoclavicular distance was measured on standard anteroposterior radiographs before and after the surgery, and union was confirmed by radiograph or computed tomography taken at 6 months postoperatively. Other radiologic complications like osteolysis was also checked. Results: Bony union was confirmed in 59 patients out of 60 patients, and 1 patient in the hook plate group showed delayed union. Coracoclavicular distance was decreased more in the hook plate group after surgery (p<0.01). After 6 weeks of the hook plate removal, the coracoclavicular distance was increased a little compared to before metal removal, but there was no difference compared to the contralateral shoulder. Eleven out of 28 patients (39.3%) showed osteolysis on the acromial undersurface in the hook plate group. Conclusions: Both the hook plate group and the locking plate group showed satisfactory radiologic results in distal clavicle fractures. Both hook plate and locking plate could be a good treatment option if it is used in proper indication in distal clavicle fracture with acromioclavicular subluxation or dislocation.

Subacromial Impingement Syndrome following Hook Plate Fixation for Distal Clavicle Fracture -A Case Report- (원위 쇄골 골절에 대한 금속판 고정술 이후 발생된 견봉하 충돌 증후군 - 증례보고 -)

  • Moon, Kyu-Pill;Kang, Min-Soo;Choi, Sung-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.1
    • /
    • pp.19-21
    • /
    • 2011
  • Clavicle Hook pate was commonly used in the injury around distal clavicle such as fractures, acromio-clavicular joint injury. We experienced a case of impingement syndrome following operation of distal clavicle fracture using Clavicle Hook plate. So we report this case with a reiview of current literatures.

  • PDF

The Use of Hook Plate on the Management of Unstable Neer II Lateral End Fracture of The Clavicle (불안정한 Neer II형 원위쇄골 골절의 치료에서 Hook 금속판의 이용)

  • Ko, Sang-Hun;Cho, Sung-Do;Park, Moon-Soo;Ryu, SuGoo
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.131-137
    • /
    • 2003
  • Purpose: Unstable Neer type II lateral end fracture of clavicle may be required operation. The purpose of this study is the effectiveness of the use of Hook plate in the management of unstable Neer type II fractures. We preliminary reported the results of Unstable Neer type II lateral end fracture of clavicle using by Hook plate. Material and Methods: From May 1998 to May 2002, we operated 6 cases unstable Neer type II lateral end fracture of clavicle with Hook plate by one surgeon. We checked radiologic evaluation and disappearance of pain per 1 week, and evaluated improvement of range of motion per 2 week. And we followed up at each interval 3 months,6 months, 12 months and after that per 6months interval, at that each time we checked stress radiogram of shoulder and functional evaluation. The shoulder function was evaluated using Modified Shoulder Rating Scale (MSRC) for Distal Clavicle Fracture and UCLA score. Average follow up was on 37.2 (12∼57) months. Results: All 6 patients were regained satisfactory function. Average MSRC for distal clavicle fracture was 17.3 (15∼20) and average UCLA score was 33.2 (31∼35) at last follow up. Conclusion: There are many advantage of the use of Hook plate on management of unstable Neer II distal clavicle fracture in spite of several disadvantage. There have not yet been reported in our country. So we obtained good to excellent clinical result in surgical treatment of 6 cases on type II displaced lateral end fracture of the clavicle. But we think that more cases will be review and longer follow up will be needed in the future.

Internal Fixation Using Clavicle Hook Plates for Distal Clavicle Fractures

  • Kim, Kwang-Yul;Kim, Hyung-Chun;Cho, Sung-Jun;Ahn, Su-Han;Kim, Dong-Seon
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • Background: To report the radiological and clinical outcomes of internal fixation using distal clavicle hook plates for distal clavicle fractures. Methods: From April 2008 to December 2012, 32 patients with distal clavicle fractures underwent surgery using an AO hook plate. The reduction was qualified and evaluated according to the radiological findings. The evaluation of the clinical outcomes was performed with the University of California at Los Angeles (UCLA) score, the Korean Shoulder score, and the visual analogue scale (VAS) pain score. Results: By radiological evaluation, we found that 31 of 32 patients showed anatomical reduction and solid bone union. Although we obtained satisfactory UCLA scores, Korean Shoulder Scale scores, and VAS pain scores, 12 cases of complications were present. We found 4 cases of osteolysis of the acromion, 1 case of nonunion, 3 cases of periprosthetic fractures, 3 cases of subacromial pain, and 1 case of skin irritation. We performed re-operations in 2 patients. Conclusions: To avoid complications associated with clavicle hook plates, choosing the appropriate hook size and bending of the hook according to the slope of the acromion undersurface is critical. Also, we believe that early removal of clavicle plates may help reduce complications.

Treatment of Acromioclavicular Joint Injuries Using Clavicle Hook Plates (Clavicle Hook Plate를 이용한 견봉 쇄골 관절 손상의 치료)

  • Kim, Myung-Ho;Seo, Joong-Bae;Moon, Sang-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.92-98
    • /
    • 2010
  • Purpose: To analyze results of treating acromioclavicular injuries using clavicle hook plates. Materials and Methods: Between February 2008 and April 2010, 18 patients with acromioclavicular joint injury treated by clavicle hook plates were reviewed. Using the Rockwood classification, 7 dislocations were classified as type III injuries and 11 as type V injuries. Implant removal was done at least 3 months from initial fixation. Simple X-rays were taken for comparing the state of reduction, and clinical outcomes were evaluated by the Korean Shoulder Scoring System and the American Shoulder Elbow Society score. The average follow-up period was 9 months. Results: On weight bearing X-rays, the average coracoclavicular distance showed a 114% increase compared to the contralateral side at the time of injury. It decreased to 23% by the last follow-up. The mean Korean Shoulder Scoring System and the American Shoulder Elbow Society score were 80 and 74 at the last follow-up. Conclusion: The immediate stability these plates provide allows rapid rehabilitation. Clavicle hook plate fixation for acromioclavicular joint dislocation is considered an effective method for ensuring satisfactory results both radiologically and clinically.

Clinical and Radiological Outcomes of Hook Plate Fixation in the Lateral End Fracture of the Clavicle and Acromioclavicular Dislocation

  • Min, Young Kyoung;Kim, Jung Han;Gwak, Heui Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • Background: The purpose of this study was to identify the clinical and radiological outcomes of hook plate fixation for lateral end fracture of the clavicle and acromioclavicular dislocation. Methods: There were a total of 20 cases with lateral end fracture of the clavicle and 16 cases with acromioclavicular dislocation. All patients were evaluated for range of motion, functional score by using Constant score, and American Shoulder and Elbow Surgeons shoulder index at just before implant removal and at final follow-up. Coracoclavicular distance was measured in acromioclavicular dislocation and bony union was evaluated in the lateral end fracture of the clavicle. Results: The clinical outcomes and range of motion were increased at the final follow-up compared with just before implant removal in both the lateral end fracture of the clavicle and acromioclavicular dislocation. In acromioclavicular dislocation, all cases-except one-showed maintenance of reduction after implant removal. Moreover, in the lateral end fracture of the clavicle, all cases-except one-showed bony union. Conclusions: Hook plate fixation in the lateral end fracture of the clavicle and acromioclavicular dislocation resulted in good clinical and radiological results.

Evaluation of the Acromioclavicular Joint Morphology for Minimizing Subacromial Erosion after Surgical Fixation of the Joint Using a Clavicular Hook Plate

  • Kim, Sung-Jae;Kee, Young-Moon;Park, Dong-Hyuck;Ko, Young-Il;Lee, Bong-Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.138-144
    • /
    • 2018
  • Background: Subacromial erosion remains a major concern after surgical fixation of acromioclavicular (AC) joint using a clavicular hook plate. To minimize postoperative subacromial erosion, we investigated the structural relationship between distal clavicle and acromion around the AC joint by considering the surgical fixation of the joint using the hook plate technique. Methods: Computed tomography scans of 101 AC joints without any inherent pathology were analyzed. The angle between the distal clavicle and acromion around the AC joint (AC angle), depth of the acromion, differences in height between distal clavicle and acromion (AC height difference), and thickness of distal clavicle and acromion at the AC joint were measured. Descriptive statistics were calculated for each anatomical parameter, and all results were compared between gender groups. Results: The mean AC angle was $17.1^{\circ}$(range, $-8.0^{\circ}$ to $39.0^{\circ}$), and the mean AC height difference was 3.5 mm (range, -0.7 to 8.7 mm). Both factors showed very high variability (coefficients of variation=62.6% and 46.6%, respectively). The mean AC angle was significantly higher in the female gender than in the male gender ($19.8^{\circ}$ vs. $13.8^{\circ}$, p=0.048). The mean acromion thickness and distal clavicular thickness were both significantly thinner in the female group than in the male group (p<0.001). Conclusions: Taken together, we believe our results might be helpful in minimizing postoperative subacromial erosion when performing surgical fixation of the AC joint using the hook plate, and be valuable in improving future design of the hook plate.

Clinical and Radiological Results of Hook Plate Fixation in Acute Acromioclavicular Joint Dislocations and Distal Clavicle Fractures

  • Oh, Joo Han;Min, Seunggi;Jung, Jae Wook;Kim, Hee-June;Kim, Jae Yoon;Chung, Seok Won;Kim, Joon Yub;Yoon, Jong Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.2
    • /
    • pp.95-100
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the clinical outcomes and complications of hook plate fixation in acromioclavicular (AC) joint dislocations and distal clavicle fractures. Methods: We retrospectively reviewed a series of 60 consecutive patients with hook plate fixation for AC joint dislocation (group I) and distal clavicle fracture (group II). Groups I and II had 39 and 21 patients, respectively. Clinical results were evaluated using the pain visual analogue scale (VAS), simple shoulder test, and Constant-Murley scores. In addition, subacromial erosion and stiffness were evaluated as complications. Results: At the removal, the pain VAS was $2.69{\pm}1.30$ and $4.10{\pm}2.14$ in groups I and II, respectively, which were significantly different (p=0.003). The simple shoulder test score was $9.59{\pm}1.60$ and $7.81{\pm}2.67$ in groups I and II, respectively, which were also significantly different (p=0.002). Subacromial erosion was significantly more frequent in group II (14/21 patients, 66.7%) than in group I (15/39 patients, 38.5%) (p=0.037), and stiffness was also higher in group II (17/21 patients, 81.0%) than in group I (22/39 patients, 56.4%), but it was not significant. Conclusions: Hook plate fixation showed good clinical and functional results for the treatment of acute unstable AC joint dislocation and distal clavicle fracture. But, in distal clavicle fractures, there are more subacromial erosion and stiffness compare with acute unstable AC joint dislocation.