• 제목/요약/키워드: Class-E inverter

검색결과 29건 처리시간 0.019초

원자력발전소 직류전원계통용 축전지 성능시험 분석 (Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant)

  • 김대식;차한주
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

E급 증폭기를 이용한 초음파발생장치 (The ultrasonic generator using inverter with class-E amplifier)

  • 임종예;윤희상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.499-501
    • /
    • 1995
  • In this paper, the generation of the intensive ultrasonic waves depend mainly on the energy convention efficiency depending on high frequency oscillation of the generator and the control performance of stable output depending on iode variation. As a result, the ultrasonic generator obtained of 95% differency with 28khz.

  • PDF

코어를 사용한 새로운 자기공진형 코일구조 (A New Coil Set with Core for Magnetic Resonant Systems)

  • 허진;임춘택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.625-626
    • /
    • 2012
  • A coupled magnetic resonance system (CMRS) using compact coil sets with core driven by a class-E inverter was proposed. The source and load coils of conventional CMRS were replaced with two coils containing core so that the system can be quite compact in size and easy to design due to a resonance frequency for all resonant tanks regardless of coupling factor. Experiments for 500 kHz switching frequency show 40% system efficiency.

  • PDF

37.5kVA급 고주파 공진형 인버터식 진단 X선 전원장치 (A 37.5kV A Class Power Supply for Diagnostic X -ray by High-Frequency Resonant Inverter Type)

  • 김학성;유동욱;임근희;완충연
    • 전자공학회논문지B
    • /
    • 제33B권12호
    • /
    • pp.113-121
    • /
    • 1996
  • This paper presents a 37.5kVA (125kVp, 300mA) high frequency inverter type power supply for diagonostic X-ray generator with two HFHV (high-frequency high-voltage) isolating transformers. The output regulations, X-ray tuve voltage and tube current, are obtained by two high frequency inverters with the each other feedback PI controller and operating time switch for selecting shooting time and synchronizing two inverters. The operating modes and design consideration of the proposed power supply are given. Issues in the design of two HFHV isolating transformersfors high volage genrating and filament heating are discussed. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advnatages, e.g., the fast rising time of tube voltae, accuracy and reduced component size etc.

  • PDF

PWM 인버터 전류제어에 의한 오디오급 엠프 구현 (Implementaion of An Audio-Glass Amplifier by Controlling the Current of PWM Inverter)

  • 이을재;권병헌;이하철;조규민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2704-2707
    • /
    • 1999
  • This paper presents a simple high power audio class amplifier which is controlled by a new current control switching method. Although this class D amplifier has an only one current control loop with the proposed switching method, a good performance can be obtained. And a novel switching strategy for driving stereo signal amplifier circuit with three phase full bridge is discussed also. With the simulation and experimental results, usefulness of the proposed amplifier is confirmed.

  • PDF

완전이식형 인공심장 구동을 위한 무선에너지 전송시스템의 개발 (Transcutaneous Energy Transmission System Development for driving totally implantable total artificial heart)

  • 안재목;이우철;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.117-122
    • /
    • 1992
  • In systems in which inductive coupling between a pancake-shaped coil on the surface of the body and a similar coil within the body is utilized for the transfort of electromagnetic energy, the minimization of temperature rise in the tissue is intimately related to the achievement of minimum losses in the region of the implanted coil. The new class of amplifiers, named "class E", for inverter is defined and is illustrated by a detailed description and a set of desist equations for one simple member of the class. For TET circuit the authors measured 65 to 76 percent efficiency at 1985kHz at 30 to 50 W output from IRF250 MOSFET transistor.

  • PDF

20 KW 전력저장전지시스템 개발 (The development of 20 KW battery energy storage system)

  • 고요;송병문;김재언;김호용;엄영창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.206-209
    • /
    • 1990
  • The battery energy storage system has been studied and adopted actively by foreign advanced utilities to use off-peak energy. Korea electro-technology research institute & KEPCO developed a small scale battery energy storage system. This system is composed of a voltage type self commutating inverter and 180 cells of 500 AH lead acid battery. Using the result of operation of the system, we make a conceptual design of MW class system.

  • PDF

Frequency-Domain Circuit Model and Analysis of Coupled Magnetic Resonance Systems

  • Huh, Jin;Lee, Wooyoung;Choi, Suyong;Cho, Gyuhyeong;Rim, Chuntaek
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.275-286
    • /
    • 2013
  • An explicit frequency-domain circuit model for the conventional coupled magnetic resonance system (CMRS) is newly proposed in this paper. Detail circuit parameters such as the leakage inductances, magnetizing inductances, turn-ratios, internal coil resistances, and source/load resistances are explicitly included in the model. Accurate overall system efficiency, DC gain, and key design parameters are deduced from the model in closed form equations, which were not available in previous works. It has been found that the CMRS can be simply described by an equivalent voltage source, resistances, and ideal transformers when it is resonated to a specified frequency in the steady state. It has been identified that the voltage gain of the CMRS was saturated to a specific value although the source side or the load side coils were strongly coupled. The phase differences between adjacent coils were ${\pi}/2$, which should be considered for the EMF cancellations. The analysis results were verified by simulations and experiments. A detailed circuit-parameter-based model was verified by experiments for 500 kHz by using a new experimental kit with a class-E inverter. The experiments showed a transfer of 1.38 W and a 40 % coil to coil efficiency.

Onechip Microcontroller에 의한 압전 변압기를 이용한 T5 28W급 형광등 전자식안정기에 관한 연구 (A study on 7528W Class Fluorescent Lamp Ballast using a Piezoelectric Transformer by means of Onechip Microcontroller)

  • 황락훈;신양호;조상로;장은성;조문택;안익수;김주래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.228-232
    • /
    • 2002
  • In this paper, In order to solve the problem is proposed using a new type of electronic ballast that the traditional magnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight which is composed of rectifier, active power corrector, series resonant half bridge inverter, micro-controller and piezoelectric transformer for driving for driving T5 fluorescent lamp were manufactured. The proposed electronic ballast operated at high frequency (about 75kHz) shows a input power factor of more than 0.995, total harmonic distortion of less than $12\%$ and lamp current crest factor of less than 1.5, respectively. Output power and efficiency showed 28w and $85\%$, respectively. Accordingly, it is considered that the ballast using piezoelectric transformer can replace the typical electronic ballast.

  • PDF