• Title/Summary/Keyword: Class of temperature

Search Result 768, Processing Time 0.025 seconds

A Study on the High Temperature Deformation Behavior of a Solid Solution Aluminium Alloy (알루미늄 고용체 합금의 고온변형 거동에 관한 연구)

  • Kim, Ho-Gyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.346-351
    • /
    • 1997
  • The creep characteristics of an Al-5wt.% Ag alloy including the stress exponent, the activation energy for creep and the shape of the creep curve were investigated at a normalized shear stress extending from $ 10^{-5}{\;}to{\;}3{\times}10^{-4}$ and in the temperature range of 640-873 K, where silver is in solid solution. The experimental results shows that the stress exponent is 4.6, the activation energy is 141 kJ/mole, and the stacking fault energy is $180{\;}mJ/m^2$, suggesting that the creep behavior of Al-5 wt.% Ag is similiar to that reported for pure aluminum, and that under the current experimental conditions, the alloy behaves as a class II(metal class). The above creep characteristics obtained for Al-5 wt.% Ag are discussed in the light of prediction regarding deformation mechanisms in solid solution alloys.

Electrical Insulation Design of a 154 kV Class HTS Cable and Termination (154 kV급 고온초전도 케이블 및 단말의 전기절연 설계)

  • Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang -Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.61-66
    • /
    • 2007
  • A transmission class high-temperature superconducting(HTS) power cable system is being developed in Korea. For insulation design of this cable the grading method of insulating paper is proposed. Two kinds of laminated polypropylene paper that has different thickness has been used as the electrical insulation material. The use of graded insulation gives improved mechanical bending properties of the cable. In a HTS cable technology the terminations are important components. A HTS cable termination is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors. in the axial direction. There is also a temperature difference from ambient to about 77 K. For insulation design of this termination, glass fiber reinforced plastic(GFRP) was used as the insulation material of the termination body, and the capacitance-graded method is proposed. This paper will report on the experimental investigations on impulse breakdown and surface flashover characteristics of the insulation materials for insulation design of a transmission class HTS power cable and termination. Based on these experimental data, the electrical insulation design of a transmission class HTS power cable and termination was carried out.

An Experimental Study on Low Nox Combustor Performance at High Pressure and Temperature for 20kW Class Microturbines (20kW급 마이크로터빈용 저공해 연소기의 고압고온 성능실험 연구)

  • Yoon, JeongJung;Oh, Jongsik;Lee, Heonseok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.183-190
    • /
    • 2002
  • In order to reduce NOx emissions in the 20kw class microturbines under development, the low NOx characteristics, as being an application to the lean premixed combustion technology, have been investigated. The study has been conducted at the conditions of high temperature and pressure. Air from a compressor with the temperature of 500K to 650K and the pressure of 0.3bar gauge to 0.7bar gauge, was supplied to the combustor through an air preheat-treatment. Sampling exhaust gases were measured at the immediate exit of the combustor. for the effect of temperature on NO and CO emissions. though NOx was increased, CO was decreased with increasing inlet air temperature. With increasing inlet air pressure, NOx and CO were increased also. NOx was decreased, but CO was increased with increasing inlet air mass flow rate. The test has been performed on the equivalent ratios of 0.10 to 0.25 in a lean region. NOx was increased with increasing equivalent ratios, but CO was decreased as an influence of flame temperature. In the very lean region of the equivalent ratio below 0.12, CO was increased suddenly, due to instability. As the results of this study, NOx and CO are found to be reduced to the similar level at the same time when operated at optimal conditions.

  • PDF

The Study on the Class Difficulty of Elementary Pre-service Teachers' Seasonal Change Unit (초등예비교사의 계절변화 단원에 대한 수업곤란도 연구)

  • Soon-shik Kim
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.16 no.3
    • /
    • pp.340-350
    • /
    • 2023
  • This study analyzed the difficulty level of class on the seasonal change unit for 84 students at a university of education. The conclusions of this study are as follows. First, if we first present the four topics that make up the seasonal changes in elementary science, the subjects that have the greatest difficulty in teaching for prospective elementary school teachers are 'Why do seasonal changes occur?' (Teaching difficulty level 4.05), 'The sun changes depending on the season' What is the difference between the southern altitude and the length of day and night?' (difficulty level of class, 3.12), 'What is the relationship between the altitude of the sun, length of shadow, and temperature during the day?' (difficulty level of class, 2.85), 'How does the temperature change depending on the season?' (class difficulty level 2.80). As a result, in the elementary science season change unit, the class on the four topics 'Why do seasons change?', which is classified as a class topic that requires the concept of spatial perception, showed a higher level of class difficulty than other units. Second, in the seasonal change unit, various factors of class difficulty appeared depending on the class topic. When pre-service elementary school teachers look at the factors that make class difficult when teaching a lesson on seasonal changes in order of frequency, 42 (50%) said 'Experimental instruction for comparing the altitude of solar masculine according to the tilt of the axis of rotation', followed by 'Solar masculine'. 38 people (45%) answered 'Difficulty in explaining mid-high altitude and the length of day and night', 27 people (32%) answered 'Difficulty in explaining the concept of mid-high altitude', and 24 people (32%) answered 'Difficulty in explaining seasonal changes in the sun's position.' 29%), 20 people (24%) said 'Explain the reasonable reason why the height of the light should be adjusted when measuring the solar altitude', and 16 people (19%) said 'It is difficult to explain the reason for the discrepancy between the solar altitude and the maximum temperature'. ), 'difficulties in measuring sand (ground) temperature' were mentioned by 12 people (14%). Third, when analyzing the factors of class difficulty, there were more curriculum factors than teacher factors. In this context, the exploratory activities on 'Why do seasonal changes occur?', the fourth topic of the seasonal change unit in which elementary school pre-service teachers showed the greatest difficulty in teaching, need improvement in terms of the curriculum.

A Study on the Characteristics of Inversion Layer Observed at Kimhae (김해에서 관측한 접지역전층의 특성에 관한 연구)

  • 박종길;원경미
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.305-315
    • /
    • 1994
  • The field observation was carried out to investigate the characteristics of surface inversion layer at Kimhae using the feild observed date and upper layer meteorological data during 4-5 February 1993. The results of the study can be summarized as follows : The maximum height of surface inversion layer observed at Kimhae is 193m and the height of upper level inversion layer ranges from 2nm to 300m. The surface weather elements was influenced the formation of surface inversion layer. According to the pasquill stability and time variation of temperature with height, both the surface heating from insolation and the disturbance of upper level of inversion layer was influenced the disappearance of inversion layer. And the stability of surface temperature inversion layer generally belongs to the class of F, that of upper level temperature inversion layer commonly to the class of E.

  • PDF

A Study on the Development of 34kW class Cryogenic Induction Motor using LNG Pump (34kW급 LNG펌프용 극저온 유도전동기 개발에 관한 연구)

  • Lee, Ki-Wook;Jeong, Dong-Wook;Park, Gwan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.999-1004
    • /
    • 2015
  • In this paper, the study presents the development of 34kW class cryogenic induction motor using LNG Pump. Operating temperature of an induction motor using LNG Main Cargo Pump is at −163℃. Due to variation of the resistivity, these motor have different torque characteristics. So, it should design to considering the resistivity change. The most important consideration of induction machine operating is cryogenic temperature. If the temperature rise, LNG is vaporized. it is a major cause of pump failure. There are several causes of heat source like coreloss, hysterisysloss, copperloss. This paper analyzed the thermal distribution of the induction motor at rated speed operation.

Numerical study on single nozzle performances for H class gas turbine based on CONVERGE CFD (H class급 가스터빈의 단일 노즐 성능에 대한 CONVERGE CFD 기반 수치 해석적 연구)

  • Kim, Jonghyun;Park, Jungsoo
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.67-72
    • /
    • 2019
  • In this study, we investigate the non-reacting and reacting performance of single nozzle for post H class gas turbine by using commercial CFD tool, CONVERGE, based on adaptive mesh refinement. By varying swirl number and mixing length of base nozzle design. Through the numerical analysis, basic phenomena can be well described with respect to fuel concentration for non-reacting flow, temperature distribution, velocity vector and combustion outlet temperature distribution for reacting flow. However, there are rooms for improvements in model accuracy by comparing test results. Comparison between numerical analysis are planning for further study.

The Manufacture and Insulating Test of Mini-model for 600kJ Class Conduction Cooled HTS SMES (600kJ급 전도냉각 HTS SMES의 미니모델 제작 및 절연평가)

  • Choi, Jae-Hyeong;Kwag, Dong-Soon;Cheon, Cheon-Gweon;Min, Chi-Hyun;Kim, Hae-Jong;Kim, Sang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.588-593
    • /
    • 2007
  • The 600kJ class high temperature superconducting magnetic energy storage (HTS SMES) system is being developed by Korean Electrotechnology Research Institute (KERI). The system is operated in cryogenic temperature and high vacuum condition. The SMS magnet was cooled by conduction cooling method using a Gifford-McMahon cycle cryocooler. Thus, electric insulation design at cryogenic temperature and high vacuum is a key and an important element that should be established to accomplish compact design is a big advantage of HTS SMES. This paper describes the electric insulation design, fabrication and experimental results for a mini model of conduction cooled HTS SMES.

Comparison of superconducting generator with 2G HTS and MgB2 wires

  • Park, S.I.;Kim, J.H.;Le, T.D.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.48-52
    • /
    • 2013
  • This paper compares the features of second generation (2G) High Temperature Superconducting (HTS) field coil with those of magnesium diboride ($MgB_2$) field coil for a 10 MW class superconducting generator. Both coils can function effectively in their respective magnetic flux density range: 10-12 T for 2G HTS field coil, 2 T for $MgB_2$ superconducting field coil. Even though some leading researchers have been developing 10 MW class superconducting generator with 2G HTS field coil, other research groups have begun to focus on $MgB_2$ wire, which is more economical and suitable for mass production. However 2G HTS wire is still appealing in functions such as in-field property and critical temperature, it shows higher in-field property and critical temperature than $MgB_2$ wire.

Experimental Study on Thermal Insulation and Cooling for Rotor/Bearing Area in 500W Class Micro Gas Turbine Generator (500W급 마이크로 가스터빈 발전기 회전체-베어링부의 단열 및 냉각 성능에 대한 실험적 연구)

  • Park, Cheol Hoon;Choi, Sang Kyu;Ham, Sang Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • Development of long-term mobile energy sources for mobile robots or small-sized unmanned vehicles are actively increasing. The micro gas turbine generator (MTG) is a good candidate for this purpose because it has both of high energy density and high power density, and 500W class MTG is under development. The designed MTG can be divided into 2 main parts. One part consists of motor/ generator and compressor, and the other one consists of combustor, recuperator and turbine. 500W class MTG is designed to operate at ultra-high speed of 400,000 rpm in high turbine temperature over $700^{\circ}C$ to improve the efficiency. Because the magnetism of NdFeB permanent magnet for the motor/generator could be degraded if the temperature is over $150-200^{\circ}C$, MTG needs the thermal insulation to block the heat transfer from combustor/turbine side to motor/generator side. Moreover, the motor/generator is allocated to get the cooling effect from the rapid air flow by the compressor. This study presents the experimental results to verify whether the thermal insulator and air flow are effective enough to keep the motor/generator part in the low temperature less than $100^{\circ}C$. From the motoring test by using the high temperature test rig, it was confirmed that the motor/generator part could maintain the temperature less than $50^{\circ}C$ under the condition of 1.0 bar compressed air.