• Title/Summary/Keyword: Class Flow

Search Result 701, Processing Time 0.03 seconds

Theme-Based Integrative Education Program Development of Industrial Specialized High School (공업계열 특성화 고등학교의 주제 중심 통합형 교육 프로그램 개발)

  • Yoon, Ji A;Lee, Chang Hoon;Kim, Ki Soo
    • 대한공업교육학회지
    • /
    • v.38 no.1
    • /
    • pp.163-194
    • /
    • 2013
  • This study aims at giving examples that can be applied in the real education field, and it develops theme-based integrative education program for Industrial Specialized high school students. It analyzed the models of many scholars about the development of education course, and devised developmental models and procedures of the theme-based integrative education program of engineering specialized high school from those. As a result, it used and reorganized ADDIE model which is the systematic education course development model and the theme-based integrative education development model of Frazee and Rudnitski(1995) as the basic structure, and came to devise theme-based integrative education program of engineering specialized high school while referring to creative engineering design education program development model by Lee Chang-hoon. This study that is theme-based integrative education program for engineering-specialized high school students and is the result of this study has the following characters. First, This theme-based integrative education program that is developed for engineering-specialized high school students can be applied and the initial example that approach the Theme-Based. Second, This Education Program included the Activity project that is "Making Maglev" for the third grade at the engineering-specialized high school and One of the Program's aim is to bring up their attitude that engaged to in the class having the Interest. Third, Theme-based integrative education program for engineering-specialized high school is composed the workbook for the students and the teaching guidance plan for the teachers. Workbook for the students is composed four Units;"Brief about the Maglev","Basic principles about the Maglev","Intensive principles about the Maglev", Activity project about the Maglev". And each unit is made by Learning Purpose, Introducing, Learning Contents(Deepen Learning, Reading Magazines), Assesment etc. Teaching guidance plan for the teachers include that Summary, Purpose, Time Planing & Streaming Map for the class, contents associated Maglev, prerequisite learning, constructure of the education program, flow chart, learning activity, assesment(self-appraiser and peer review).

The Surgical Management of Hypoplastic Left Heart Syndrome and the Results of a Fontan Operation (좌심형성부전증후군의 외과적 치료 및 폰탄수술의 결과)

  • Chung, Eui Suk;Kim, Woong-Han;Jeon, Jae-Hyun;Choi, Chang-Hyu;Lee, Chang-Ha;Lee, Young-Tak
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • Background: Hypoplastic left heart syndrome is uniformly fatal if this condition is not properly treated. We reviewed the surgical results of treating hypoplastic left heart syndrome, and we evaluated the hemodynamics and functional status of these patients after they underwent a Fontan operation. Material and Method: To assess the surgical results, we retrospectively reviewed the medical records of 6 (M/F=4/2) patients who underwent a staged operation, including a Norwood procedure, a bidirectional Glenn procedure and a Fontan procedure between October 1997 to May 2005. The mean age of the patients was $17.3{\pm}10.8$ days (range: 9~36 days) at the $1^{st}$ staged operation, $8.9{\pm}7.1$ months (4.6~23.3 months) at the $2^{nd}$ staged operation (the Bidirectional Glenn procedure) and $32.4{\pm}9.8$ months at the final staged operation (the Fontan procedure). During the $2^{nd}$ staged operation, one of the patients received tricuspid valve repair due to regurgitation. All the patients underwent an extracardiac Fontan procedure using Gore-Tex conduit (20 mm: 2 patients, 18 mm: 4 patients) and one of them required fenestration. Result: 21 patients underwented a Norwood procedure. There were 7 early deaths and 4 interstage deaths. Bidirectional cavopulmonary shunt was performed in 10 patients and the Fontan procedure was done in 6 (mortality: 1 patient, Flow up loss: 1 patient, Awaiting a Fontan procedure: 2 patients). After the Fontan procedure, there was no complication except for one case of post operative bleedings. All the patients had good ventricular function and 2 had grade I tricuspid regurgitation, as noted on their echocardiography. The average follow up period after the Fontan procedure was $19.6{\pm}14.9$ months (range: 1.5~39.1 month). All the patients had normal sinus rhythm and they were put on aspirin and cardiac medication. During follow up period, all the patients had a good functional status (NYHA functional class I). Conclusion: All the patients who suffered with hypoplastic left heart syndrome and who underwent a Fontan procedure achieved a good hemodynamic and functional status, even though there was a relatively high operative mortality rate after stage I Norwood palliation. Therefore, thise staged operation should be strongly recommended as an important surgical strategy for treating hypoplastic left heart syndrome.

The Effects of Mean Grain Size and Organic Matter Contents in Sediments on the Nutrients and Heavy Metals Concentrations (퇴적물 내 입도와 유기물 함량이 영양염류 및 중금속 농도에 미치는 영향)

  • Kim, Seog-Ku;Lee, Mi-Kyung;Ahn, Jae-Hwan;Kang, Sung-Won;Jeon, Sang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.923-931
    • /
    • 2005
  • A study was carried out to identify the major causes of sediments pollution in the Paldang Lake in the vicinity of Gyeongan river. Samples from 40 sites were collected and analyzed to characterize the regional distributions of grain size, organic matter contents, and concentrations of T-N, T-P and heavy metals. contaminations. The mean grain size(Mz) ranged from sand type(Mz, $1{\sim}3\;{\phi}$) where Bukhan River and Namhan River converges at a high flow rate to silt type(Mz, $5{\sim}10\;{\phi}$) at the downstream of Gyeongancheon and Paldang lake, reflecting the water circulation in the area. Except sampling point St. 36 near the wetland, the determination coefficient($r^2$) of Mz and organic matter(LOI) was 0.88, showing that more organic matters are concentrated inside finer sediments. The concentrations of T-N and T-P in sediments were higher in the area at which Mz and organic matters are also higher. High concentrations of T-P analyzed in the sediments, ranging from $216{\sim}1,623\;{\mu}g/g$ (Avg. $769\;{\mu}g/g$) could be considered as a critical level. Adsorbed-P and NAI-P, which are easily released to the surrounding environments when physico-chemical characteristics of sediments are changed, was found to be around 20%, which was showed by the result of fractionated-P. Moreover, Principle Component Analysis(PCA), showed that high concentrations of T-N, T-P, organophilic metals (Cd, Cu, Pb, Zn) are distributed in the areas where high organic matter contents and fine grain-sized sediments are found. However, results of $I'_{geo}$ (Geoaccumulation Index) that considers the grain size of sediments showed that heavy metal concentrations in the lake was low enough to be considered as Class 1 indicating the relative degree of pollution was less than zero.

Improvement of Fontan Circulatory Failure after Conversion to Total Cavopulmonary Connection (완전 대정맥-폐동맥 연결수술로 전환 후의 폰탄순환장애 개선)

  • Han Ki Park;Gijong Yi;Suk Won Song;Sak Lee;Bum Koo Cho;Young hwan Park
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.559-565
    • /
    • 2003
  • By improving the flow pattern in Fontan circuit, total cavopulmonary connection (TCPC) could result in a better outcome than atriopulmonary connection Fontan operation. For the patients with impaired hemodynamics after atriopulmonary Fontan connection, conversion to TCPC can be expected to bring hemodynamic and functional improvement. We studied the results of the revision of the previous Fontan connection to TCPC in patients with failed Fontan circulation. Material and method: From October1979 to June 2002, eight patients who had failed Fontan circulation, underwent revision of previous Fontan operation to TCPC at Yonsei University Hospital. Intracardiac anomalies of the patients were tricuspid atresia (n=4) and other functional single ventricles (n=4). Mean age at TCPC conversion was 14.0$\pm$7.0 years (range, 4.6~26.2 years) and median interval between initial Fontan operation and TCPC was 7.5 years (range, 2.4~14.3 years). All patients had various degree of symptoms and signs of right heart failure. NYHA functional class was 111 or IV in six patients. Paroxysmal atrial fibrillation (n:f), cyanosis (n=2), intraatrial thrombi (n=2), and protein losing enteropathy (PLE) (n=3) were also combined. The previous Fontan operation was revised to extracardiac conduit placement (n=7) and intraatrial lateral tunnel (n=1). Result: There was no operative death. Major morbidities included deep sternal infection (n=1), prolonged pleural effusion over two weeks (n=1), and temporary junctional lachyarrhythrnia (n=1). Postoperative central venous Pressure was lower than the preoperative value (17.9$\pm$3.5 vs. 14.9$\pm$1.0, p=0.049). Follow-up was complete in all patients and extended to 50,1 months (mean, 30.3$\pm$ 12.8 months). There was no late death. All patients were in NYHA class 1 or 11. Paroxysmal supraventricular tachycardia developed in a patient who underwent conversion to intraatrial lateral tunnel procedure, PLE was recurred in two patients among three patients who had had PLE before the convertsion. There was no newly developed PLE. Conclusion: Hemodynamic and functional improvement could be expected for the patients with Fontan circulatory failure after atriopulmonary connection by revision of their previous circulation to TCPC. The conversion could be performed with low risk of morbidity and mortality.

Field Assessment of in Situ Remediation of NO3--contaminated Ground Water Using Zero-valent Iron/Bio Composite Media (영가철/바이오 복합처리제를 이용한 질산성 질소 오염 지하수의 현장 지중정화 적용성 평가)

  • Joo, Wan-Ho;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.1
    • /
    • pp.35-48
    • /
    • 2021
  • In this study, the assessment of field applicability of in-situ remediation of nitrate-contaminated groundwater located in Yesan-gun was performed. Zero-valent iron/bio composite media injected PRB (Permeable Reactive Barrier) and monitoring well were installed in the contaminated groundwater site and monitored main remediation indicators during the PRB operation. Nitrate, nitrite, ammonia, Fe ion, TOC, and turbidity were analyzed and the diversity and population of microorganism in the PRB installed site were investigated for the verification of effect of injected PRB. In the study site where is an agricultural area, a river flows from west to east that forms a river boundary and the southern area has an impermeable sector. It was found that nitrate flows into the river, which is similar as groundwater flow. Simulation result for the fate of nitrate in groundwater showed steady state of nitrate arrived after 3~5 years passed. However, it is just to consider current conditions with no additional input of contaminant source, if additional input of contaminant source occurs contamination dispersion and time for steady state are expected to be increased. The monitoring results showed that Fe ion, TOC and turbidity in groundwater were not clearly changed in concentration after PRB installation, which indicates adaptability of the injected PRB for remediation of groundwater with no additional harmful effect to water quality. The concentration of nitrate maintained less than 5mg/L until 42 days after PRB installation and recovered its initial concentration after 84 days passed and showed termination of reactivity of injected zero-valent iron/bio composite media for removal nitrate. Nitrite and ammonia ions found after installation of PRB indicates reductive removal of nitrate. And the outstanding increase of microorganism diversity and population of Betaproteobacteria Class which includes denitrification microorganism explains biologically reductive removal of nitrate in injected PRB.

A Review on the Performance Criteria of Equipment Required for Asbestos Removal (석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰)

  • Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.212-221
    • /
    • 2013
  • Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.

Trend Analysis of Curriculum Application Status of 2015 Revised Integrated Science and Scientific Laboratory Experiment Curriculum (2015 개정 통합과학과 과학탐구실험 교육과정의 2차 년도 적용 현황 추이 분석)

  • Kwak, Youngsun
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.13 no.1
    • /
    • pp.53-63
    • /
    • 2020
  • The purpose of this study is to analyze the current status of the second year of application of Integrated Science and Science Laboratory Experiments, which are common courses of high school, and to explore suggestions for curriculum development in the future. To this end, the results of the survey of a total of 244 science-core and general high schools were compared with the survey result of 2018 school year. In addition, in-depth interviews were conducted with nine science teachers of the focus group to discuss the current state of curriculum implementation. According to the results, as in the first year, most of the Integrated Science courses were implemented in 6-8 units, and in most schools the number of teachers in charge of Integrated Science per class were 3-4. In the teacher's focus group interview, teachers insisted that Integrated Science requires integrated teaching approaches and is good for generating students' interest, but it is difficult to implement process-based assessment due to issues such as ensuring fairness of assessment. Most of Science Laboratory Experiments courses were implemented in two semesters, one unit per semester, and there was little link between Integrated Science and Science Laboratory Experiments because of the different teaching staff. The school life record entry method of Science Laboratory Experiments has been changed to criterion-based assessment starting in 2019, so students' satisfaction or flow of classes is much better than expected, and teachers can teach without burden. Based on the research results, ways to support the settlement of Integrated Science and Science Laboratory Experiments as common subjects, and ways to improve those subjects in the next curriculum revision were suggested.

Effects of FUll-FEat Flax Seed, $\alpha$-Tocopherol and Selenium on the Expression of cell Surface Antigen of Broiler Chickens (아마종실과 $\alpha$-Tocopherol, 셀레늄 급여가 육계의 세포표면항원 발현에 미치는 영향)

  • 안종남;채현석;문진산;김동운;권명상;박병성
    • Korean Journal of Poultry Science
    • /
    • v.28 no.3
    • /
    • pp.231-237
    • /
    • 2001
  • To examine the effects of feed additives on the expression of perpheral blood cell surface molecules, phagocytosis and antigen specific antibody formation, broilers were randomly assigned to $T_{1}$ , $T_{2}$ , $T_{3}$ , and $T_{4}$ groups. $T_{1}$ group was fed diet without any additives for 13 weeks, $T_{2}$ was fed diet with full fat flax, $T_{3}$ was fed diet with full fat flax containing $\alpha$-tocopherol, and $T_{4}$ was fed diet with full- fat flax containing $\alpha$-tocopherol and selenium. Since 5 weeks feeding the data were examined by flow cytometry using a panel of monoclonal antibodies. The expression of monocyte in all treated groups was significantly increased, in which the ratio of expression in $T_{3}$ group was especially evident. B cell expression of all treated groups was increased more than 2 fold. The expression of CD4+(helper T cell) cell and CD8+(cytotox$ic^pressor T cell) cell of all treated groups also was increased.ed.

  • PDF

Ictal single-photon emission computed tomography with slow dye injection for determining primary epileptic foci in infantile spasms (영아연축에서 추적자의 느린 점적주사를 이용한 발작기 SPECT)

  • Hur, Yun Jung;Lee, Joon Soo;Kang, Hoon Chul;Park, Hye Jung;Yun, Mi Jin;Kim, Heung Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.7
    • /
    • pp.804-810
    • /
    • 2009
  • Purpose : We investigated whether ictal single-photon emission computed tomography (SPECT) with prolonged injection of technetium-99m (99mTc) ethyl cysteinate dimer during repeated spasms can localize the epileptogenic foci in children with infantile spasms. Methods : Fourteen children with infantile spasms (11 boys, 3 girls; mean age, $2.2{\pm}1.3$ years) were examined. When a cluster of spasms was detected during video electroencephalography (EEG) monitoring, $^{99m}Tc$ ethyl cysteinate dimer was slowly and continuously injected for 2 minutes to determine the presence of ictal SPECT. For 7 children, the ictal and interictal SPECT images were visually analyzed, while for the remaining 7 children, the SPECT images were analyzed using the subtraction ictal SPECT coregistered to magnetic resonance imaging (MRI) (SISCOM) technique. Subsequently, we analyzed the association between the ictal SPECT findings and those of other diagnostic modalities such as EEG, MRI, and positron emission tomography (PET). Results : Increase in cerebral blood flow on ictal SPECT involved the epileptogenic foci in 10 cases6 cases analyzed by visual assessment and 4 analyzed by the SISCOM technique. The ictal SPECT and video-EEG findings showed moderate agreement (Kappa=0.57; 95% confidence interval, 0.18-0.96). Conclusion : Ictal SPECT with prolonged injection of a tracer could provide supplementary information to localize the epileptogenic foci in infantile spasms.

Basic Design of 36 MTD Class Natural Gas BOG Re-Liquefaction System (36 MTD급 천연가스 BOG 재액화 플랜트 기본설계)

  • Ko, Junseok;Park, Seong-Je;Kim, Ki-Duck;Hong, Yong-Ju;Koh, Deuk-Yong;Kim, Hyobong;Yeom, Hankil
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.99-105
    • /
    • 2013
  • In this paper, we carried out the basic design of 36 MTD natural gas BOG re-liquefaction system to recover the generated natural gas during performance test of LNG pump and natural gas compressor. The re-liquefaction process of natural gas is designed to have 1500 kg/h of liquefaction rate with reverse Brayton refrigeration cycle. With the designed process, the variation of liquefaction rate is calculated for various inlet conditions of feed gas. From results, the liquefaction rate is more sensitive for inlet temperature than gas composition. The specifications of equipments such as gas blower, natural gas compressor, cryogenic heat exchanger and nitrogen compander are determined on the basis of the designed process. The requirement of power consumption and cooling water are also determined through the basic design.