• 제목/요약/키워드: Clamping Force

검색결과 201건 처리시간 0.046초

Locker 의 물림각이 쐐기형 레일클램프의 압착력에 미치는 영향 평가 (The Effect of Clamping Angle of a Locker on the Clamping Force of the Wedge Type Rail Clamp)

  • 한동섭;이성욱;한근조;안찬우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.1042-1045
    • /
    • 2005
  • The wedge type rail clamp has the operating mechanism: First, the jaw pad clamps a rail with small clamping force. Next as the wind speed increases, the clamping force of the Jaw pad Is Increased by the wedge. The initial clamping force of a jaw pad was determined by the clamping angle of a locker. In this study, we carried out the finite element analysis to evaluate the relationship between the clamping angle of a locker and the clamping force of a jaw pad with respect to the design wind speed, such as 2, 4, 6, 8, and 10m/s, we adopted the wedge type rail clamp fur 50tons class container crane with the wedge angle of $10^{\circ}$.

  • PDF

체결력 산포와 마찰계수의 감소를 위한 가진기의 진동량 변화 실험 (An Experimental Study of Vibrator Amplitude Change for a Clamping Force Dispersion and Friction Coefficient Decrease)

  • 이금강;문석만;조용주
    • Tribology and Lubricants
    • /
    • 제27권6호
    • /
    • pp.332-337
    • /
    • 2011
  • The object of this experimental study is to investigate influences of vibrator amplitude on clamping force in vibration for bolted joint. The experiment is that change the vibrator amplitude to check clamping force. also the friction coefficient calculated by equation to use an obtained in experiments. The main purpose of generation vibrations is decreasing the clamping force dispersion. also If vibration occurs while tightening the bolt is reduced coefficient of friction. In this paper, In experiments to measure the clamping force before vibrator's amplitude changing. Vibrator's amplitude changes to 5.5mm from 4.4mm. As a result, under various vibration condition, relationship of clamping force and Vibrator amplitude.

소재와 나사산 변화에 따른 정밀나사의 체결력 향상에 관한 연구 (A Study on the Clamping Improvement of Precision Screws according to the Materials and Thread Changes)

  • 황우채;나승우
    • 한국정밀공학회지
    • /
    • 제32권6호
    • /
    • pp.503-507
    • /
    • 2015
  • In this study, we compare the performance of the screw through the Clamping force of the test materials to change shape and structure, one of the ways to maintain and improve the engaging force to cope with the miniaturization of the fastener threads are further thinner and lighter precision way that can improve the fastening force of the screw results were as follows. The clamping force according to the materials was $7.57N{\cdot}cm$ in SUS XM7 and SWCH18A was $5.97N{\cdot}cm$. This result was to be found to average 13.5% high in the Clamping force of SUS XM7 materials. In the case of the clamping force of the screw thread shape change, the clamping force of symmetrical and asymmetrical thread was $6.78N{\cdot}cm$ and $7.57N{\cdot}cm$. The clamping force of the asymmetrical thread showed an average high of 11.6%.

인접홀에서 홀확장법과 체결력 고려시, 발생하는 잔류응력 분포에 대한 유한요소해석 (Finite Element Analysis of Residual Stress by Cold Expansion Method with Clamping Force in the Plate having Adjacent Holes)

  • 양원호;조명래;장재순
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.149-154
    • /
    • 2006
  • The cold expansion method (CEM) is one of the widely used a method to improve the fatigue behavior of materials in aerospace industry. Such improvement is due to the compressive residual stress developed when a tapered mandrel goes through the fastener holes a little smaller than the mandrel. CEM is retarded of crack initiation due to the compressive residual stress developed on the hole surface. Many researchers are studied a finite element analysis of residual stress around fastener hole. But in case of real model, fastener hole has a clamping force after CE. Therefore, it is respected that residual stress distributions should be changed due to clamping forces. In this paper, it was performed finite element analysis of residual stress by clamping force after CE in the plate having adjacent holes. From this study, it has been found that compressive residual stress near the hole increases according to clamping force. Also, the more increase clamping force, the more increases compressive residual stress. However, tensile residual stress increase beyond clamping force area.

초기압착력 설정을 위한 쐐기형 레일클램프의 창의적 설계 (Creative Design of the Wedge Type Rail Clamp to set the Initial Clamping Force)

  • 한동섭;김용;이성욱;한근조
    • 한국기계가공학회지
    • /
    • 제6권3호
    • /
    • pp.58-64
    • /
    • 2007
  • The clamping force of a jaw pad is determined by the displacements of main part when two lockers are locked, after the clamping angle of a locker was set up in the wedge type rail clamp for a container crane. In this time, if the resistance of wedge frame generates due to several factors, the clamping angle of a locker to display the initial clamping force will be changed because of the reduction of displacement of extension bar. This resistance is determined by the eccentric distance between the roller and the wedge, and by the gap between the wedge frame and outer frame. In this study we measured the tensile force of both extension bar through the performance test of the prototype rail clamp in order to evaluate the effect of the resistance of wedge frame on the clamping force of the wedge type rail clamp.

  • PDF

소형 스핀들 시스템 적용을 위한 형상기억합금 기반 공구 클램핑 장치의 체결특성 고찰 (Investigation for Clamping Properties of the Tool Clamping Device Based on the Shape Memory Alloy for Application of a Micro Spindle System)

  • 신우철;노승국;박종권;이득우;정준모
    • 한국공작기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.9-14
    • /
    • 2007
  • In this paper, a rotating tool clamping device was developed based on a shape memory alloy(SMA) and its feasibility as a tool holder was experimentally explored. The SMA-based device was able to alter clamping to unclamping through temperature control within 1 second. The means and repeatability(${\sigma}$) of the tool clamping force were 185.5N and 6N respectively and its drifts were less than 3% for an hour. Considering the temperature hysteresis of the SMA-based tool clamping device, it is necessary to heat the SMA ring to around $50^{\circ}C$ after tool change to obtain more clamping force.

자기 체결 마찰 클러치의 전달 토크에 관한 연구 (A Study on the Transmitted Torque of Self Clamping Friction Clutch)

  • 왕지석;김종도;윤희종
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1149-1156
    • /
    • 2008
  • The principle of self clamping friction clutch is presented in this paper and the transmitted torque capacity is also calculated. In order to enlarge the friction force, a part of rotating force of driving side is converted to normal force of friction materials by clamping arm. The increased normal force of friction materials assures the large friction force and the transmitted torque capacity of clutch becomes large. The self clamping friction clutch is adopted in the tube type air pressure clutch and the condition of stability is investigated. It is proven that the inclined angle of clamping arm and the friction factor of friction materials are the essential elements in stability and torque capacity of self clamping friction clutch. The transmitted torque capacity of self clamping friction clutch is compared with air pressure clutch. The normal force of friction lining is magnified by 1/(1-k) and the transmitted torque capacity is also magnified with same proportion comparing with air pressure clutch. The larger the friction factor of friction lining, the larger the magnification factor. The longer the clamping arm, the smaller the magnification factor. It must be also noted that the value of k=${\mu}Y/X$ is the criterion of stability. If the value of k=${\mu}Y/X$ is greater than or equal to 1, the self clamping friction clutch is unstable and it can not be used as clutch.

전자 제어식 주차브레이크 시스템의 제동력 추정 기법 (A Clamping Force Estimation Method in Electric Parking Brake Systems)

  • 장민석;이영옥;이원구;이충우;손영섭;정정주
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2291-2299
    • /
    • 2008
  • Hall effect force sensors have been used to measure clamping force in conventional Electric Parking Brake(EPB) systems. Estimation of clamping force without the sensors has drawn attentions due to mounting space limitations and cost issues. Removing the sensor requires the estimation of the initial contact point where the clamping force is effectively applied to the brake pads. In this paper, we propose how to estimate the initial contact point finding the relation between the angular velocity of an actuator and the initial contact point. For force estimation a look-up table is used as a function of the displacement of parking cable from the initial contact point. The proposed method is validated by experiments. From the experimental results we observe that the proposed method satisfies the specifications. The designed method is also able to estimate clamping force although parking cables are loosened and brake pads are worn out. Applying the proposed method enables manufacturing of low cost EPB systems.

텐션클램프의 초기 체결력이 탄성레일체결장치의 성능에 미치는 영향 (Influence of Initial Clamping Force of Tension Clamp on Performance of Elastic Rail Fastening System)

  • 이동욱;최정열;백찬호;박용걸
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.1243-1251
    • /
    • 2013
  • 본 연구의 목적은 텐션클램프의 초기 체결력이 급곡선 궤도용 탄성레일체결장치의 성능에 미치는 영향을 검토함에 있다. 이를 위해 본 연구에서는 탄성레일체결장치의 구성품 중 텐션클램프의 거동을 평가하기 위해 초기 체결력의 변화와 횡압의 증가를 고려한 실내시험, 현장측정 및 수치해석을 수행하였다. 수치해석 및 실험결과, 초기 체결력의 감소는 텐션클램프에 도입되는 초기 압축응력의 감소로 나타났다. 또한 텐션클램프의 압축응력은 급곡선 궤도에서 발생하는 횡압의 작용에 따라 인장응력으로 변환되는 것으로 나타났다. 따라서 초기 체결력에 의해 텐션클램프에 도입된 압축응력은 외력에 따른 발생 인장응력 저감을 위한 보강력으로 작용하는 것으로 분석되어, 탄성레일체결장치의 장기 내구성능 확보와 안정적인 거동을 유지하기 위해서는 적정 초기 체결력의 확보가 중요한 것으로 나타났다.

초소형 나사의 나사산 각도변화에 따른 체결특성 평가 (Evaluation of Clamping Characteristics for Subminiature Screws According to Thread Angle Variation)

  • 민경빈;김종봉;박근;나승우
    • 한국정밀공학회지
    • /
    • 제31권9호
    • /
    • pp.839-846
    • /
    • 2014
  • Recent trends in the miniaturization and weight reduction of portable electronic parts have driven the use of subminiature screws with a micrometer-scale pitch. As both screw length and pitch decrease in subminiature screws, the resulting clamping force becomes diminishes. In this work, Finite element (FE) analysis is performed to evaluate clamping force of a screw assembly, with a comparison with experimental result. To improve clamping force of subminiature screws, a new screw design is considered by modifying screw thread angle: the thread angle is varied as an asymmetric way unlike the conventional symmetric thread angle. FE analyses are then performed to compare the clamping characteristics of each subminiature screw with different thread angle. The effect of thread angles on the clamping force is then discussed in terms of structural safety for both positive and negative screws.