• Title/Summary/Keyword: Clamping

Search Result 737, Processing Time 0.031 seconds

Failure load prediction of mechanically fastened composite joint with the clamping force (클램핑 포스가 존재하는 복합재료 체결부의 파손강도 예측)

  • Ryu, Choong-O;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.18 no.5
    • /
    • pp.9-14
    • /
    • 2005
  • The design of composite joint is a very important research area because they are often the weakest areas in composite structures. In this paper, the failure load of the mechanically fastened composite joint with the clamping force was predicted by the failure area index method. By the suggested failure area index method, the strength of the mechanically fastened composite joint could be predicted within $22.5\%$ when the clamping force was applied to the composite joint.

A Study on the Zero-Voltage-Switching Three-Level DC/DC Converter using Primary Clamping Diodes (1차측 클램핑 다이오드를 이용한 ZVS Three-Level DC/DC 컨버터에 관한 연구)

  • Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.101-108
    • /
    • 2013
  • This paper presents A Zero-Voltage-Switching(ZVS) Three-Level DC/DC Converter using Primary Clamping Diodes. The Previous ZVS Three-Level DC/DC converter realizes ZVS for the switches with the use of the leakage inductance(or external resonant inductance) and the output capacitors of the switches, however the rectifier diodes suffer from recovery which results in oscillation and voltage spike. In order to solve this problem, this paper proposes a novel ZVS Three-Level DC/DC converter, which introduces two clamping diodes to the basic Three-Level converter to eliminate the oscillation and clamp the rectified voltage to the reflected input voltage.

Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode (능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선)

  • Yoon, Shin-Yong;Baek, Hyun-Soo;Kim, Yong;Kim, Cherl-Jin;Eo, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

Electrical Properties and Clamping Voltage Characteristics of ZPCCY-Based Varistor Ceramics (ZPCCY계 바리스터 세라믹스의 전기적 성질 및 제한전압 특성)

  • Nahm Choon-Woo;Park Jong-Ah
    • Korean Journal of Materials Research
    • /
    • v.15 no.3
    • /
    • pp.143-148
    • /
    • 2005
  • The microstructure, electrical properties, and clamping voltage characteristics of $ZnO-Pr_6O_{11}-CoO-Cr_2O_3-Y_2O_3(ZPCCY)-based$ varistor ceramics sintered at $1350^{\circ}C$ were investigated as a function of sintering time from 1 to 3 h. With increasing sintering time, the average grain size and density increased in the range of $11.4\~16.0\;{\mu}m$ and $5.34\~5.54g/cm^3$, respectively, in accordance of increasing sintering time. The nonlinear exponent decreased in the range of $60\~26$ and the leakage current increased in the range of $1.3\~10.7\;{\mu}A$ with increasing sintering time. The clamping voltage ratio increased in the range $1.58\~1.65$ for ratio surge current of 10 A as the sintering time increased.

A Single Stage Isolated Power Factor Correction Power Supplies using Clamping Circuit (클램핑 회로를 이용한 단계층 절연 역률 보정 전원 공급장치)

  • Seo, Jai-Ho;Lee, Hee-Seung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2021-2023
    • /
    • 1998
  • In this paper we further propose to add a very simple regenerative clamping circuit to SSIPP to reduce the voltage stress and to recycle the energy trapped in the leakage inductance of the isolation transformer, thus eliminating the need for a lossy snubber circuit. In addition, this proposed clamping circuit also provides a mechanism to reset the magnetizing current of the output transformer of SSIPP employing a Forward converter as the output stage. Simulations and experimental results are reported to verify the operation and performance of the SSIPP with regenerative clamping.

  • PDF

A Study of Bolt Tightening Changing Factor according to Durability Degradation (내구 열화에 따른 샤시계 볼트 체결력 변화 인자 연구)

  • Choi, Dong Young;Choi, Jae Chil;Han, Jong Uk
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.1
    • /
    • pp.20-26
    • /
    • 2015
  • In vehicle development process, durability test should be carried out in field condition. Nowadays there are many customer live there multiple conditions. It makes change of the car's material. Such change causes to lose a bolt. Diversifications of climatic conditions are also a matter of loosening the bolt. To avoid this problem, to identify the cause of the problem, and the solution should be applied. To avoid problems during the durability development test should be measured by the clamping force. Ultrasonic instruments clamping force without affecting the torque can be measured. This instrument is part of the problem by monitoring the clamping force required to obtain objective data.

Optimized Series Connection of Power Semiconductor Using Active Clamping Method (Active Clamping 방식을 이용한 전력용 반도체의 최적 직렬연결 방법)

  • Kim, Bong-Seong;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2143-2145
    • /
    • 2005
  • Power semicondcutor인 IGBT MOSFET, GTO, SI-Thyristor등은 높은 스위치 신뢰성과 life time, 그리고 fast repetition rate 등을 지니고 있기 때문에 medium/High voltage영역에서 스위치 사용이 대두되어 왔으나, Thyratron이나 Trigatron(Gap switch)와 비교하여 낮은 전압/전류를 스위칭하기 때문에 전통적으로 직렬연결을 통해 high voltage 영역의 스위치로 사용되어 왔다. 하지만, 직렬연결되어 있는 각각의 power semiconductor와 gate driving circuit의 on/off synchronization이 맞지 않기 때문에 부하의 급격한 변화에 따른 전압의 balance에 문제가 가장 심각하게 대두되어 왔다. 이러한 문제를 해결하기 위해서 gate driving circuit에서 제어를 해주는 방법과 power semiconductor에서 제어를 해주는 방법이 있으나 두 방식 모두 문제점이 있다. 본 논문에서는 기존의 zener clamping방식에서 벗어나 새로운 active clamping방식의 직렬연결을 제안했으며 시뮬레이션과 실험을 통해 나타난 이 결과들은 on/off transient 시 symmetry를 유지하는데 효과적이라는 것을 보여주고 있다.

  • PDF

A Study on the Interleaved Active-Clamping Forward Converter (인터리브 방식을 이용한 액티브 클램핑 포워드 컨버터에 관한 연구)

  • Jung, Jae-Yeop;Kim, Yong;Kwon, Soon-Do;Bae, Jin-Yong;Lee, Dong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.156-160
    • /
    • 2009
  • This paper presents the interleaved active-clamping ZVS(Zero Voltage Switching) forward converter, which is mainly composed of two active-clamping forward converters. Only two switches are required, and each one is the auxiliary switch for the other. The circuit complexity and cost are thus reduced. The leakage inductance of the transformer or an additional resonant inductance is employed to achieve ZVS during the dead times. The duty cycles are not limited to be equal and within 50%. The complementary switching and the resulted interleaved output inductor currents diminish the current ripple in output capacitors. Accordingly, the smaller output chokes and capacitors lower the converter volume and increase the power density. Detailed analysis and design of this new interleaved active-clamping forward converter are described.

  • PDF

Force Synchronizing Control for 4 Axes Driven Hydraulic Cylinder-Clamping Load Systems (4축 구동 유압실린더-클램핑 부하 시스템의 힘 동기제어)

  • Cho, S.H.
    • Journal of Drive and Control
    • /
    • v.11 no.2
    • /
    • pp.9-15
    • /
    • 2014
  • This paper deals with the issue of force synchronizing control for the clamping servomechanism of injection molding machines. Prior to the controller design, a virtual design model has been developed for the clamping mechanism with hydraulic systems. Then, a synchronizing controller is designed and combined with an adaptive feedforward control in order to accommodate the mismatches between the real plant and the linear model plant used. As a disturbance, the leakage due to the ring gap with relative motion in the cylinder has been introduced. From the robust force tracking simulations, it is shown that a significant reduction in the force synchronizing error is achieved through the use of a proposed control scheme.

A study on reduction of clamping force for plastic back cover of large TV (대형 TV의 플라스틱 후면 커버 성형시의 형체력 절감 방안 연구)

  • Song, Jae-Choon;Han, Seong-Ryeol
    • Design & Manufacturing
    • /
    • v.13 no.1
    • /
    • pp.36-41
    • /
    • 2019
  • A large plastic molding requires an injection molding with a large clamping force. However, it could not be prepared in the manufacturing at any time. In order to solve the problem, the injection molding analysis study was conducted on the back cover of 55 inch LED TV. The study compared the case of applying the existing flow system such as hot runner, the improvement of the hot runner lay-out and the precise control of the gate operation time, From the results of using the improved flow system, it was found that the welding and the clamping force were considerably improved as compared with before the improvement. In particular, the clamping force was reduced by 50% compared with before the improvement.