• Title/Summary/Keyword: Civil code

Search Result 1,178, Processing Time 0.165 seconds

Strain interaction of steel stirrup and EB-FRP web strip in shear-strengthened semi-deep concrete beams

  • Javad Mokari Rahmdel;Erfan Shafei
    • Steel and Composite Structures
    • /
    • v.47 no.3
    • /
    • pp.383-393
    • /
    • 2023
  • Conventional reinforced concrete design codes assume ideal strain evolution in semi-deep beams with externally bonded fiber-reinforced polymer (EB-FRP) web strips. However, there is a strain interaction between internal stirrups and web strips, leading to a notable difference between code-based and experimental shear strengths. Current study provides an experiment-verified detailed numerical framework to assess the potential strain interaction under quasi-static monotonic load. Based on the observations, steel stirrups are effective only for low EB-FRP amounts and the over-strengthening of semi-deep beams prevents the stirrups from yielding, reducing its shear strength contribution. A notable difference is detected between the code-based and the study-based EB-FRP strain values, which is a function of the normalized FRP stress parameter. Semi-analytical relations are proposed to estimate the effective strain and stress of the components considering the potential strain interaction. For the sake of simplification, a linearized correction factor is proposed for the EB-FRP web strip strain, assuming its restraining effect as constant for all steel stirrup amounts.

Technical Overview of UIC CODE on Speed for Speed Improvement of Conventional Korean Lines (기존선 속도향상을 위한 UIC CODE 속도규정의 기술적 검토)

  • Kim Jeongguk;Chung Jong-Duk;Kim Jin-Hwan;Hong Yong-Ki;Kim Weon-Kyung;Pyun Jang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.262-268
    • /
    • 2004
  • In order to improve the speed of conventional Korean lines, the amendment of speed related regulations is required as the introduction of Korean tilting train. Therefore, an extensive review of UIC leaflets on speed was performed in the areas of tilting train, rolling stocks, operation, civil infrastructures, etc. The review was mainly achieved through the overview of parameters directly related with speed of railway. Moreover, a summary of UIC leaflets on speed and tilting train was provided for a better understanding of speed related UIC CODE. Through the technical overview of UIC CODE, necessary information on the amendment of current Korean speed regulations could be provided.

  • PDF

Comparison of code provisions on lap splices

  • Canbay, Erdem
    • Structural Engineering and Mechanics
    • /
    • v.27 no.1
    • /
    • pp.63-75
    • /
    • 2007
  • The code provisions on lap splices are critically assessed in the light of 203 beams without transverse reinforcement and 278 beams with transverse reinforcement. For comparison, the provisions given in the ACI 318, Eurocode 2, and TS 500 Codes are considered. The ACI Committee 408 recommended provision and a new proposal are also taken into account throughout the assessment. The comparison with real beam tests where the splice region was subjected to constant moment indicates that current provisions in the Codes do not agree acceptably with test results. The steel stress prediction graphs calculated by means of the Code provisions show high scatter and remain unsafe especially for test data without transverse reinforcement. Both the recent recommended provision by ACI Committee 408 and a new design expression proposed by the author have much less scatter with fewer unsafe predictions. The simplified design provision proposed by ACI Committee 408 does not yield similar results to that of the advanced design provision proposed by the same committee and therefore it could conveniently be replaced with the simpler equation proposed by the author.

Modal rigidity center: it's use for assessing elastic torsion in asymmetric buildings

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • v.1 no.2
    • /
    • pp.163-175
    • /
    • 2010
  • The vertical axis through the modal center of rigidity (m-CR) is used for interpreting the code torsional provisions in the design of eccentric multi-story building structures. The concept of m-CR has been demonstrated by the author in an earlier paper and the particular feature of this point is that when the vertical line of the centers of mass at the floor levels is passing through m-CR, minimum base torsion is developed. For this reason the aforesaid axis is used as reference axis for implementing the code provisions required by the equivalent static analysis. The study examines uniform mixed-bent-type multistory buildings with simple eccentricity, ranging from torsionally stiff to torsionally flexible systems. Using the results of a dynamic response spectrum analysis as a basis for comparisons, it is shown that the results of the code static design are on the safe side in torsionally stiff buildings, but unable to predict the required strength of bents on the stiff side of systems with a predominantly torsional response. Suggestions are made for improving the code provisions in such cases.

Buckling behavior of bundled inclined columns: Experimental study and design code verification

  • Moussa Leblouba;Samer Barakat;Raghad Awad;Saif Uddin Al-Khaled;Abdulrahman Metawa;Abdul Saboor Karzad
    • Steel and Composite Structures
    • /
    • v.52 no.2
    • /
    • pp.183-197
    • /
    • 2024
  • Not all structural columns maintain a vertical orientation. Several contemporary building structures have inclined columns, introducing distinct challenges, particularly in buckling behavior. This study examines the buckling behavior of inclined, thin-walled steel bundled columns, differing from typical vertical columns. Using specimens with three tubes welded to plates linearly aligned at the top and triangularly at the bottom, tests indicated that buckling capacity increases with tube wall thickness and diameter but decreases with column height. Inclined tubes in bundled columns showed improved buckling resistance over vertical ones. Results were verified against standard steel design guidelines to assess their predictive accuracy.

A Study on the Service Life Prediction of Reinforced Concrete Structures with Chloride Penetration (철근콘크리트 구조물의 염해에 의한 사용수명 예측에 관한 연구)

  • Kim Dong-Baek;Kwon Ki-Jun;Park Byung-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.113-118
    • /
    • 2005
  • Recently, the corrosion of reinforced concrete structures has received great attention related with the deterioration of sea-side structures, such as new airport, bridges, and nuclear power plants. In this regards, many studies have been done on the chloride attack in concrete structures. The purpose of the present study is to explore the influences of chloride attack parameters to service life of reinforced concrete structures and to propose the rational program for the guarantee of service life. for this purpose, several codes for durability design have been examined and the diffusion analysis based on Fick's second law has been performed with various parameter value. The present study indicates that durability design code of Japan Society of Civil Engineers is more rational than other codes but the application of durability design code of JSCE to domestic durability design needs more studies to the various parameter values related with chloride penetration.

Seismic Behavior of Liquid Storage Tanks Using Complex and Simple Analytical Models

  • Nabin, Raj Chaulagain;Sun, Chang Ho;Kim, Ick Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.401-409
    • /
    • 2018
  • Performance-based seismic evaluation is usually done by considering simplified models for the liquid storage tanks therefore, it is important to validate those simplified models before conducting such evaluation. The purpose of this study is to compare the seismic response results of the FSI (fluid-structure interaction) model and the simplified models for the cylindrical liquid storage tanks and to verify the applicability of the simplified models for estimating failure probability. Seismic analyses were carried out for two types of storage tanks with different aspect ratios (H/D) of 0.45 and 0.86. FSI model represents detailed 3D fluid-structure interaction model and simplified models are modeled as cantilever mass-spring model, frame type mass-spring model and shell type mass-spring model, considering impulsive and convective components. Seismic analyses were performed with modal analysis followed by time history analysis. Analysis results from all the models were verified by comparing with the results calculated by the code and literature. The results from simplified models show good agreement with the ones from detailed FSI model and calculated results from code and literature, confirming that all three types of simplified models are very valid for conducting failure probability analysis of the cylindrical liquid storage tanks.

Estimation of Earthquake Magnitude-Distance Combination Corresponding to Design Spectrum in Korean Building Code 2016 (우리나라 건축물 설계 스펙트럼에 상응하는 지진규모와 진앙거리의 추정)

  • Jeong, Gi Hyun;Lee, Han Seon;Hwang, Kyung Ran
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.31-39
    • /
    • 2017
  • In this study, to estimate the combination of earthquake magnitude ($M_w$) and distance (R) corresponding to the design spectrum defined in Korean Building Code (KBC) 2016, the response spectra predicted from the attenuation relationships with the variation of $M_w$ (5.0~7.0) and R (10~30km) are compared with the design spectrum in KBC 2016. Four attenuation relationships, which were developed based on local site characteristics and seismological parameters in Southern Korea and Eastern North America (ENA), are used. As a result, the scenario ground motions represented by the combinations of $M_w$ and R corresponding to the design spectrum for Seoul defined in KBC 2016 are estimated as (1) when R =10 km, $M_w=6.2{\sim}6.7$; (2) when R = 15 km, $M_w=6.5{\sim}6.9$; and (3) when R = 20 km, $M_w=6.7{\sim}7.1$.

Investigating the effect of bond slip on the seismic response of RC structures

  • Fallah, Mohammad Mehdi;Shooshtari, Ahmad;Ronagh, Hamid Reza
    • Structural Engineering and Mechanics
    • /
    • v.46 no.5
    • /
    • pp.695-711
    • /
    • 2013
  • It is reasonable to assume that reinforced concrete (RC) structures enter the nonlinear range of response during a severe ground motion. Numerical analysis to predict the behaviour therefore must allow for the presence of nonlinear deformations if an accurate estimate of seismic response is aimed. Among the factors contributing to inelastic deformations, the influence of the degradation of the bond slip phenomenon is important. Any rebar slip generates an additional rotation at the end regions of structural members which are not accounted for in a conventional analysis. Although these deformations could affect the seismic response of RC structures considerably, they are often neglected due to the unavailability of suitable models. In this paper, the seismic response of two types of RC structures, designed according to the Iranian concrete code (ABA) and the Iranian seismic code (2800), are evaluated using nonlinear dynamic and static analyses. The investigation is performed using nonlinear dynamic and static pushover analysis considering the deformations due to anchorage slip. The nonlinear analysis results confirm that bond slip significantly influences the seismic behavior of RC structure leading to an increase of lateral deformations by up to 30% depending on the height of building. The outcomes also identify important parameters affecting the extent of this influence.

Design thermal loading for composite bridges in tropical region

  • Au, F.T.K.;Cheung, S.K.;Tham, L.G.
    • Steel and Composite Structures
    • /
    • v.2 no.6
    • /
    • pp.441-460
    • /
    • 2002
  • In the design of bridges, it is important to consider the thermal stresses induced by the non-linear temperature distribution as well as the variation of effective temperature in the bridge deck. To cope with this, design temperature profiles are provided by design codes, which are normally based on extensive research work. This paper presents the results of a comprehensive investigation on the thermal behaviour of bridges in Hong Kong with special emphasis on composite bridges. The temperature distribution in bridges depends primarily on the solar radiation, ambient air temperature and wind speed in the vicinity. Apart from data of the meteorological factors, good estimates of the thermal properties of material and the film coefficients are necessary for the prediction of temperature distribution. The design temperature profiles for various types of composite bridge deck with bituminous surfacing and concrete slab of different thicknesses are proposed. The factors affecting the design effective temperature are also reviewed and suitable values for Hong Kong are proposed. Results are compared with recommendations of the current local code. The method facilitates the development of site-specific temperature profiles for code documents, and it can also be applied to create zoning maps for temperature loading for large countries where there are great climatic differences.