• Title/Summary/Keyword: Civil Society

Search Result 18,071, Processing Time 0.042 seconds

A Study on the Engineering Properties of Grout Materials Using a Magnetic Field Treated Water (자화수를 사용한 주입재의 공학적 특성에 관한 연구)

  • Chun, Byung-Sik;Park, Doo-Hee;Yang, Hyung-Chil;Jung, Jong-Ju;Lee, Sang-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1195-1203
    • /
    • 2006
  • Water that is treated by passing through a magnetic field of certain strength is called Magnetic Field Treated Water(MFTW). Previous research indicate that use of MFTW can save 5% of cement dosage, decrease bleeding of concrete, and improve resistance to freezing. The reason why MFTW can improve characteristics of concrete can be explained by the molecular structure of water. Magnetic force can break apart water clusters into single molecules or smaller ones, therefore, the activity of water is improved. While hydration of cement particles is in progress, the MFTW can penetrate the core region of cement particles more easily. Hence, hydration takes place more efficiently which in turn improves concrete compressive strength. Test results demonstrate that the compressive strength of the sodium silicate cement grout homogel increases by approximately 20 - 50% by using the MFTW.

  • PDF

Analysis on the characteristics of rainfall driven landslides through field study (현장조사를 통한 강우로 인한 철도연변 사면의 활동 특성분석)

  • SaGong, Myung;Hwang, Seon-Keun;Lee, Su-Hyung;Kim, Hyun-Ki;Kim, Min-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.145-152
    • /
    • 2005
  • Landslides triggered by rainfall produces severe effects on the serviceability and stability of railway operation. Since small amount of soil mass slipped on the rail can cause derailment which will cause severe danger on the human and trains, slope stability problem is one of the major concerns on the operation of railway. In this study we investigate the some of characteristics of rainfall driven landslide near railroad. A total of 23 sites were visited. From the results four types of landslides based upon the morphology of the slipped slope triggered by rainfall were classified. From the analysis dimensions of slopes (height, length and slope) do not show particular correlation with the types of landslides. In addition, morphological and geological features of slope influence on the occurrence of different types of landslides.

  • PDF

The evaluation of applicability for several final settlement prediction methods to field settlement management by measurement results carried on embankment on the soft clays (계측결과를 이용한 연약지반상 성토시의 최종침하량예측기법들의 현장적용성)

  • Kim, Jong-Ryeol;Gang, Hee-Bog;Choi, Ju-Myoung;Hwang, Soung-Won;Kim, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.924-931
    • /
    • 2005
  • In this study, we intended to compare and examine several settlement management methods by analyzing measurement results of a site of the industrial complex at ${\bigcirc}{\bigcirc}$ province. We predicted and analyzed the amount of final settlement by using generally used final settlement methods as like Hyperbola method, Hoshino methods and Asaoka method. And then, We compared the predicted results with that of measurement. On the basis of comparison of the three methods, Hyperbola method was the most convenient and accurate method of the three methods and if a sufficient time was given enough after embankment construction, the use of Hoshino method was possible. In the case of the Asaoka methods, it was possible to know that it had an approaching tendency to the measured one with increasing time interval spent on analysis. Therefore, in order to predict settlement behavior more accurately it is needed to understand their advantages and shortcomings sufficiently and pay attention to application to the real site.

  • PDF

An Experimental Study and Deformation Analysis of a Dredged fills Improved with Bamboo Mats (대나무매트가 포설된 준설매립지반의 모형실험 및 변형해석)

  • Kim, Jong-Ryeol;Kang, Kwon-Soo;Kim, Woo-Jin;Hwang, Sung-Won;Kang, Jin-Tae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1520-1527
    • /
    • 2005
  • In order to investigate the effect of improvement with bamboo mats on dredged fills, several tests were performed with different widthes (0.0B, 0.5B, 1.0B, 2.0B). The results indicate that the failure modes of the models without bamboo mats are close to local shear failure, and change to general shear failure as the width of a bamboo mat increases. A series of tests with four different widths (0.0B, 0.5B, 1.0B, 2.0B) were carried out on the models which have no desiccated surface layers, to find out the width that the general shear failure might occur. Finally, a series of tests with this width were performed on the models with three different desiccated surface layers (3cm, 5cm, 10cm). Throughout the tests, strength and deformation according to the thickness of desiccated surface layer was investigated.

  • PDF

ON-LINE PSEUDO-DYNAMIC NETWORK TESTING ON BASE-ISOLATED BRIDGE USING WEB-BASED JAVA MONITORING SYSTEM (자바 모니터링 서버를 이용한 면진교량의 온라인 네트워크 유사동적 실험)

  • Park, D.U.;Yun, C.B.;Lee, J.W.;Nagata, K.;Watanabe, E.;Sugiura, K.
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.477-486
    • /
    • 2005
  • 본 논문에서는 한국과 일본에 위치한 여러 연구기관들 사이에서 수행된 온라인 네트워크 유사동적 실험 결과에 대해 나타내었다.예제 구조물로는 4경간 연속의 면진 교량을 이용하였다. 실험 장비를 보유하고 있는 두 연구기관에서 면진 장치의 비선형 거동에 대한 실험을 수행하고 각 실험 결과를 조합하여 전체 구조의 동적 해석을 수행하였다. 본 논문에서는 먼저 인터넷을 이용한 두 가지 데이터 전송기법을 이용하여 두 기법의 효율성을 비교, 분석하였다. 또한 최근 국내에 위치한 두 연구기관 사이에서 수행된 실험 결과에 대해 논의하였다. 본 연구에서는 상대 연구기관의 실험 상황 및 수행된 실험 결과의 효율적인 모니터링을 위하여 웹 기반의 자바 모니터링 시스템을 개발하였다. 마지막으로 유선과 무선 인터넷을 이용한 온라인 실험 기법에 대하여 나타내었다. 그 결과, 온라인 네트워크 실험에 소요된 실험 시간은 데이터 전송 기법과 실험장비에 따라 매 시간 단계의 데이터 전송에 0.2-15초, 각 연구기관의 유사동적 실험에 1-10초의 시간이 소요되어 매우 큰 폭으로 변화함을 알 수 있었다. 또한 무선 인터넷을 이용한 온라인 실험의 경우, 뛰어난 이동성과 인터넷 보안성 등과 같은 여러 가지 장점을 가지고 있음을 알 수 있었다.

  • PDF

Evaluation of geochemical processes affecting groundwater chemistry in Namwon, Korea

  • Kim, Kang-Joo;Natarajan Rajmohan;Kim, Hyung-Jung;Kim, Suk-Hwi;Hwang, Gab-Soo;Cho, Min-Joe;Lee, Sang-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.334-337
    • /
    • 2004
  • Groundwater chemistry in Namwon area, Korea, was investigated to understand the contribution of geochemical processes on groundwater chemistry. For this study, a total of 279 groundwater samples were collected from 93 wells distributed over the study area. Higher concentrations of major ions are generally encountered in the shallow alluvial wells, suggesting that these chemicals are originated from the surface contamination sources. Mass balance analysis based on reaction stoichiometry reveals that the water chemistry is regulated by three major chemical processes: weathering of silicate/ carbonate minerals, input of C1/SO$_4$ salts, and nitrate generating processes. The results show that mineral weathering is the most dominating factor regulating the groundwater chemistry. However, the groundwaters with the higher salt concentration indicate the larger mineral weathering effect, suggesting that some part of the mineral weathering effect is also associated with the anthropogenic activities such as limes applied to the cultivated lands, carbonates (CaCO$_3$) in the cement materials.

  • PDF

Governing Design Factors of GFRP-Reinforced Concrete Bridge Deck (GFRP 근 보강 콘크리트 교량 바닥판의 설계지배인자)

  • Cho, Jeong-Rae;Park, Young Hwan;Park, Sung Yong;Cho, Kunhee;Kim, Sung Tae
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.70-77
    • /
    • 2015
  • In this study, the governing design factors of GFRP-reinforced concrete bridge deck are analyzed for typical bridges in Korea. The adopted bridge deck is a cast-in-situ concrete bridge deck for the prestressed concrete girder bridge with dimensions of 240 mm thickness and 2.75 m span length from center-to-center of supporting girders. The selected design variables are the diameters of GFRP rebar, spacings of GFRP rebars and concrete cover thicknesses, Considering the absence of the specification relating GFRP rebar in Korea, AASHTO specification is used to design the GFRP-reinforced concrete bridge deck. The GFRP-reinforced concrete bridge deck is proved to be governed by the criteria about serviceability, especially maximum crack width, while steel reinforced concrete bridge deck is governed by the criteria on ultimate limit state. In addition, GFRP rebars with diameter of 16 mm ~ 19 mm should be used for the main transverse direction of decks to assure appropriate rebar spacings.

Study of MF membrane as pretreatment option using various backwash process from wastewater reuse pilot plant (전처리 MF의 다양한 역세 공정을 적용한 하수재이용 파일럿 플랜트 연구)

  • Park, Kwang-Duck;Park, Chansoo;Lee, Chang-Kyu;Kim, Jong-Oh;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.335-341
    • /
    • 2016
  • Various studies have forwarded an outstanding wastewater effluent treatment systems toward securing sustainable supply of water sources. In this paper, a broad overview of the performance of MF membrane as pretreatment option for wastewater reuse will be presented based on the literature survey and experiments conducted over the wastewater reuse pilot plant. The pilot plant was operated with a continuous data acquisition for about 300days under various chemical enhanced backwash (CEB) system with subsequent treated water quality analysis. Accordingly, assessment of the effluent revealed that the pretreated water is suitable enough to be used as an input for Reverse Osmosis (RO) unit and significant effect of CEB and concentration of NaOCl is also conceived from the analysis. Moreover, it's also observed that the application of various CEB condition over long operational hours induced a constant declination of overall performance of MF membrane.

Analysis of hydraulic system for seawater desalination plant through piping analysis program (배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석)

  • Choi, Jihyeok;Choi, Yongjun;Yang, Heungsik;Lee, Sangho;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

Reuse Possibility of By-pass Flow and Secondary Effluent using BAF (BAF를 이용한 2차 처리수의 재이용 가능성 및 강우시 하수처리장 월류수의 처리)

  • An, J.H.;Park, J.B.;Kim, S.W.;Park, J.H.;Ha, J.S.;Choi, E.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.190-195
    • /
    • 2005
  • The laboratory and pilot scale BAFs (biological aerated filters) were operated with 0.3 hr to 1.1 hr EBCT(empty bed contact time) at a maximum filtration rate of $472m^3/m^2/day$ as a treatment method for reuse of secondary effluent and by-pass flow in this study. The effluent BOD and SS were generally 3.5 to 5 mg/L and 2 to 3 mg/L, respectively with 2ndary effluent, but the SS concentrations increased to 4 to 8 mg/L with the increased flow rates of by-pass flow. Potential nitrification rates were very high, but the nitrogen removal efficiencies were low due to the limited carbon sources. Bypass of a part of primary effluent seemed to be desirable to increase the nitrogen removal. Disinfection must be furnished for the reuse of BAF effluent.