• 제목/요약/키워드: City Tower

검색결과 80건 처리시간 0.023초

Structural Design of Cheongna City Tower

  • Chung, Kwangryang;Kim, Jung-Hyun;Song, Younghoon;Kim, Sihyeong;Kang, Jihun
    • 국제초고층학회논문집
    • /
    • 제10권3호
    • /
    • pp.193-201
    • /
    • 2021
  • Cheongna City Tower is a 448-meter-high rise observatory tower with 8.7:1 aspect ratio located at central lake park in Incheon Cheongna international city. The tower is a crystal shaped image and it turns invisible when the façade is activated. The tower was planned to be hexagonal 30-story building with two basements which are composed of mega frame structure using mega column and mega brace. In order to minimize the wind effect, the blow-through area was installed so that the wind can pass through. This observatory tower is an unprecedented project since the whole building is covered by façade for invisibility effect.

PETRONAS TWIN TOWER 2 프로젝트의 공정관리에 관한 고찰 (A Study on the Scheduling of PETRONAS TWIN TOWER 2 PROJECT)

  • 최순묵
    • 기술사
    • /
    • 제33권3호
    • /
    • pp.59-63
    • /
    • 2000
  • The purpose of this study is to understand the method of scheduling of Petronas twin tower project. Petronas twin tower is the highest building in the world today. Kuala Lumpur City Center Berhad which is owner of Petronas twin tower, managed this construction project by use of useful scheduling techniques, that is, milestone, NSC, NS, PDM, rolling wave, hammock. Now we consider this techniques and try to apply to our construction management.

  • PDF

Ministry of Taxation Tower in Baku, Azerbaijan: Turning Away from Prescriptive Limitations

  • Choi, Hi Sun;Ihtiyar, Onur;Sundholm, Nickolaus
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.377-386
    • /
    • 2020
  • Beginning a few decades ago, Baku, the capital city of Azerbaijan, has experienced a dramatic construction boom that is revitalizing its skyline. The expansive growth looks to uphold the historic past of Baku as a focal point within the Caspian Sea Region while also evoking aspirations for a city of the future. With superstructure complete and interiors progressing, the Ministry of Taxation (MOT) tower is the latest addition to the city, with its stacked cubes twisting above a multi-level podium at the base. Each cube is separated by column-free green roof terraces, creating unique parametric reveals of the developing surroundings. Aside from MOT's stunning shape, its geolocation resulted in unusually high wind loads coupled with high seismic hazards for a tower of its height. In addition, limitations on possible structural systems required stepping away from a typical prescriptive code-based approach into one that utilized Performance-Based Design (PBD) methods. This paper presents the numerous structural challenges and innovations that allowed the design of a new icon to be realized.

Bayesian structural damage detection of steel towers using measured modal parameters

  • Lam, Heung-Fai;Yang, Jiahua
    • Earthquakes and Structures
    • /
    • 제8권4호
    • /
    • pp.935-956
    • /
    • 2015
  • Structural Health Monitoring (SHM) of steel towers has become a hot research topic. From the literature, it is impractical and impossible to develop a "general" method that can detect all kinds of damages for all types of structures. A practical method should make use of the characteristics of the type of structures and the kind of damages. This paper reports a feasibility study on the use of measured modal parameters for the detection of damaged braces of tower structures following the Bayesian probabilistic approach. A substructure-based structural model-updating scheme, which groups different parts of the target structure systematically and is specially designed for tower structures, is developed to identify the stiffness distributions of the target structure under the undamaged and possibly damaged conditions. By comparing the identified stiffness distributions, the damage locations and the corresponding damage extents can be detected. By following the Bayesian theory, the probability model of the uncertain parameters is derived. The most probable model of the steel tower can be obtained by maximizing the probability density function (PDF) of the model parameters. Experimental case studies were employed to verify the proposed method. The contributions of this paper are not only on the proposal of the substructure-based Bayesian model updating method but also on the verification of the proposed methodology through measured data from a scale model of transmission tower under laboratory conditions.

The Impact of Supertall Density on City Systems

  • Price, Bill;Bickerdyke, Andrew;Borchers, Meike;Gabbitas, Tim;Hailey, Lee
    • 국제초고층학회논문집
    • /
    • 제6권4호
    • /
    • pp.327-332
    • /
    • 2017
  • This paper discusses several topics associated with the densification caused by supertall buildings and their impact on city systems. The paper covers five key areas where a supertall tower creates a concentration of needs and effects. First, the paper comments on population shifts towards the city and how they affect carbon footprint, utilities infrastructure and transport. The effect of single- and mixed-use towers is discussed in the context of population density. The second section brings the issues of transit, accessibility and master planning into focus. The use and criticality of public transport, cycling and walking is described. Servicing and deliveries using freight consolidation and shared systems is also discussed along with their contribution to the culture of sustainable travel. In the third section the paper reflects on supertall buildings' below-ground utilities and drainage provision, particularly the challenges faced in established city infrastructures. The utilities issues associated with supertall concentration (in land-use terms) compared to equivalent low-rise distribution is also commented on in the context of surface water runoff. In the fourth section, the topic of supertall sustainability is discussed and how city systems need to respond to create desirable and affordable space for occupiers. The changing need for vertical communities, 'stacked neighbourhoods' and the notion of a micro-city is described. Finally, the paper considers the energy consumption and resilience of supertall buildings in the context of basic geometry, façade design, climate and mixed-use benefits as they impact city systems.

지하역사 실내형 냉각탑 성능개선 연구 (A study on an improvement of indoor cooling tower efficiency)

  • 배성준;황선호;신창헌;표수철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1726-1735
    • /
    • 2008
  • Seoulmetro has operated the air cooling equipment for 57 stations to improve services focused on our customers who use Seoulmetro during the summer season and has established every year. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. The most important matter is loss of efficiency in the cooling tower. The leading cause of this problem is that we use an indoor type. As the cooling tower room is located in the underground of the city because of the residents near the station. Therefore It is difficult to establish the cooling tower on the ground. But it is unsuitable for the location requirements of the underground type because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. To prevent this situation, the operator tend to reduce refrigerant. Accordingly, the efficiency of the air conditioning is getting lower and lower. Study wishes to analyze the matter to improve indoor cooling tower efficiency and recommend a best practice for a person who manage the establishment.

  • PDF

창원시 아파트 공급량에 영향을 미치는 요인에 관한 연구 (A Study on Factors Affecting the Supply of Apartments in Changwon City)

  • 성주한
    • 토지주택연구
    • /
    • 제11권4호
    • /
    • pp.35-50
    • /
    • 2020
  • The purpose of this study is to examine which factors are important in determining the amount of the apartment supply in Changwon City. Additionally, this study is to examine the changes in the determination of the amount of apartment supply in Changwon by dividing it into before and after 2016 as the city showed a large difference in apartment supply that caused structural changes during this time period. This study shows that the increase in the number of housing construction permits in Changwon before 2016 had a negative impact on the housing market as well as causing a decrease in the supply of apartments in Changwon after 2016. As a result of the shortsighted predictions on the housing market of Changwon from before 2016, it still affects the current housing market as of June 2020. The implication of this study is that through the housing market system of Changwon City, they can take the role as a control tower in Changwon City and propose principles and standards for supply control in order to better predict the demand of the housing market.

대청호 추동취수탑 부근의 수질변화 특성 (Variation of Water Quality around the Chudong Intake Tower in Daechung Reservoir)

  • 마심초;임봉수;허순욱;곽미애
    • 한국물환경학회지
    • /
    • 제31권6호
    • /
    • pp.637-643
    • /
    • 2015
  • This study has been carried out to provide the basic data obtained from the evaluation of the variation of water quality around the Chudong intake tower in Daechung resevoir, which may be able to help the establishment of a pure water supply policy. Five sites around the Chudong intake tower were selected, and the average data for recent ten years(from year 2004 to year 2013) were analysed. The average water quality around Chudong intake tower are as followed; pH 7.5, DO 8.7 mg/L, BOD 1.0 mg/L, COD 3.0 mg/L, SS 3.0 mg/L, TN 1.495 mg/L, TP 0.017 mg/L, and Chlorophyll-a 6.5 mg/m3 were matched the good class by comparing with the living environment standard of reservoir. COD values of higher than 3.0 mg/L after July were likely due to non-point pollutants and algae outbreak during rainy summer season. Total phosphorus rose sharply in the summer season, and then algae watch was issued consistently for average 40 days. Total nitrogen to total phosphorus ratio was average 90, and it is important to control the inflow phosphrous from small stream for proper management to block an algae growth according to eutrophication. It was recommended to operate the algae removing boats around intake tower from July to October, and was required advanced water treatment processes to remove NBD COD and bad odor and taste due to algae growth.

사비시대 부여지역 가람건축의 특성에 관한연구 - 평지 1탑식 가람을 중심으로 - (The Study on the Characteristics of Puyeo district's Buddhist Temple Architechture in Sabi dynasty - Focus on the plot plan for a tower on Flatland -)

  • 이동영
    • 한국농촌건축학회논문집
    • /
    • 제13권2호
    • /
    • pp.71-78
    • /
    • 2011
  • The main characteristic of one tower style temple on flatland, as a type of early buddhist temple, is to have been built on level ground near the capital city with their intent to be connected with power group in those days. Two kind of one tower temples on flatland had mostly been constructed: Wondang(longing temple) and National temple, and they greatly contributed to popularization of Buddhism. So, the purpose of this study is to analyze the examples of one tower temple plot planning made by centering around Puyeo district of Sabi dynasty, and in another aspects, examine the influence on our traditional temple architecture and the meaning of Korean traditional architecture, because it is the most important thing among Korean traditional architecture. This study is significant because we have researched in the documents and fruit of an excavation about one tower style temple in Puyeo district in Sabi dynasty, so it will be helpful in studying Buddhist temple architecture system in Puyeo district in Sabi dynasty.

환경수(냉각탑수)로 부터 Legionella속 균의 분리 (Isolation of the Legionella Species from Specimens of Cooling Tower Water)

  • 정종학;강복수;김석범;사공준
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.77-84
    • /
    • 1988
  • 환경수로부터 Legionella속 균의 분리를 위해 대구시 내 24개의 대형건물의 냉각탑수를 대상으로 1987년 7월과 9월 2차례에 걸쳐 총 48개의 검수를 채취하여 Legionella속 균의 분리를 시도하였다. 9월에 채취한 냉각탑수 24개중 3개에서만 Legionella가 분리되었으며 동정 결과 이들은 모두 L. pneumophila로 판명되었다. 이들의 serotype, 지속성, 병원성을 밝히기 위해 계속적인 연구가 요망된다. 이상의 결과로 보아 우리 나라의 환경수중에 분포되어 있는 Legionella속 균은 대부분 L. pneumophila인 것으로 추정되며, 우리 나라에서는 계절 변화가 뚜렷하여 겨울철에는 냉각 시설을 가동하지 않는 관계로 냉각탑수 중에서의 Legionella의 검출율은 초 여름보다 늦 여름에 높은 것으로 생각된다.

  • PDF