• Title/Summary/Keyword: Circulation method

Search Result 975, Processing Time 0.026 seconds

The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility (하나로 유동모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

A Study on the Method for Increasing Customer's Circulation in Large-Scale Retail Store (대형 소매점에서 내점객의 회유성을 증대시키는 레이아웃에 관한 연구)

  • 백승환;류호창
    • Korean Institute of Interior Design Journal
    • /
    • no.15
    • /
    • pp.69-78
    • /
    • 1998
  • Purchasing should be considered as an exciting entertainment by itself in these days. Customers can be satisfied with making their own choices and dreaming of their better lives through the action of buying,. However the customers are not rushing into stores without any special reason except when the store has something attracts them. Generally speaking the customers will willingly spend their time and effort in shopping only when they are attracted by well-displyed goods and reasonably planned layout. Based upon these concepts interior design as a creative marketing tool plays a great role in enhancing customer's circulation and the productivity of a store. This study is to propose the layouts which are increasing the customer's circulation by contacting the customers with commodities as many as possible. This study is primarily revolved around the parts affecting customer's circulation among the factors of store's layouts. This study was consist of theoretical consideration about the store's layouts on the foundation of conference and existing works and several proposals. The results of this research are as below: 1) The entrance and exit of a retail store should be apart from each other to increase customers' circulation. It is regarded as ideal to locate the entrance on the right side of front to control moving line of customers. 2) A shop should be surrounded with the main aisles which is straightened inward from the main entrance. 3) Placing magnets which can be anything that attracts customers' attention at the corner of store can lead customers inward and increase customers' circulation.

  • PDF

The Analysis for Flow Circulation System in HANARO Flow Simulation Facility (하나로 유동 모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.30-35
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. HANARO flow simulation facility is being developed for the endurance test of reactivity control units for extended life time and the verification of structural integrity of those experimental equipments prior to loading in the HANARO. This facility is composed of three major parts; a half-core structure assembly, a flow circulation system and a support system. The flow circulation system is composed of a circulation pump, a core flow piping, a core bypass flow piping and instruments. The system is to be filled with de-mineralized water and the flow should be met the design requirements to simulate a similar flow characteristics in the core channel of the half-core structure assembly to the HANARO. This paper, therefore, presents an analytical analysis to study the flow behavior of the system. Computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with the standard $k-{\epsilon}$ turbulence model and for the verification of the structural piping integrity through the finite element method. According to the analysis results, it could be said that the design requirements and the structural piping integrity of the flow circulation system are satisfied.

A Study on the Impact of Commercial Complex Anchor Tenant Plan in the Pedestrian Traffic - Focused on the Change of the Pedestrian Traffic by Reopening Anchor tenant of Lotte World Mall - (대형 복합 상업건축의 앵커 테넌트 계획이 통행량에 미치는 영향에 관한 연구 - 롯데월드몰 앵커 테넌트 개장 전·후 통행량 변화를 중심으로 -)

  • Yoon, Tae-Jun;Lee, Do-Hun;Park, Hyeon-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.5
    • /
    • pp.128-135
    • /
    • 2015
  • The purpose of this study is to propose a planning method for increasing visitors' usage attraction by understanding user circulation in the large scale commercial complex. Focusing on the impact of anchor tenant on the pedestrian traffic arousing visitors' usage attraction flow, this study analyzed pedestrian circulation and traffic volume of Lotte World Mall, a large scale commercial complex. In this study, the change of pedestrian traffic in the commercial complex was investigated and the circulation flow of anchor tenant visitors such as movie theater in the commercial complex was simulated by computer. By analyzing both characteristics of pedestrian circulation and traffic volume in large scale commercial complex and movie theater users' pedestrian traffic with network-based computer simulation, positive relationship between pedestrian traffic to movie theater and pedestrian traffic dispersion of the whole commercial complex users was emerged. In addition, It is necessary to plan of distributing pedestrian traffic of vertical moving line in central space appropriately for using attraction function of anchor tenant.

An experimental study on the operating performance of facade installed natural circulation type solar thermal system (수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구)

  • Baek, Nam-Choon;Lee, Wang-Je;Lee, Jin-Kook;Lee, Soon-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

Use Studies of Library Collections (장서평가에 관한 소고 -특히 이용조사를 중심으로-)

  • Yoo Chae-Ock
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.15
    • /
    • pp.175-195
    • /
    • 1988
  • Use studies of library collections have been conducted as a method of evaluating collections in a library. The main purpose of use studies is to evaluate the quality of a library collection in terms of extent and mode of its use. In addition to use studies, both quantitative and qualitative methods could be utilized in order to evaluate a library collection. However, the quantitative and qualitative collection evaluation methods are more concerned with the collection itself than with its use. Use studies have been conducted in large academic libraries for the following specific purposes: 1) They attempt to identify little used portion of collections that can be retired less accessible and less expensive storage area. 2) They try to identify core collections to satisfy some degree of circulation demands in the near future. 3) They try to identify use patterns of selected subject areas or type of books that can be used to adjusting collection development practices or fund allocations. 4) They try to assess the document delivery capability of a library to improve their availability. A number of methodologies employed for these specific purposes fall into four major categories; 1) circulation analysis method, 2) last circulation method, 3) relative use method, and 4) document delivery test. Each method is briefly reviewed with its limitations.

  • PDF

Improvement on the Laminated Busbar of NPC Three-Level Inverters based on a Supersymmetric Mirror Circulation 3D Cubical Thermal Model

  • He, Feng-You;Xu, Shi-Zhou;Geng, Cheng-Fei
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2085-2098
    • /
    • 2016
  • Laminated busbars with a low stray inductance are widely used in NPC three-level inverters, even though some of them have poor performances in heat equilibrium and overvoltage suppression. Therefore, a theoretical method is in need to establish an accurate mathematical model of laminated busbars and to calculate the impedance and stray inductance of each commutation loop to improve the heat equilibrium and overvoltage suppression performance. Firstly, an equivalent circuit of a NPC three-level inverter laminated busbar was built with an analysis of the commutation processes. Secondly, on the basis of a 3D (three dimensional) cubical thermal model and mirror circulation theory, a supersymmetric mirror circulation 3D cubical thermal model was built. Based on this, the laminated busbar was decomposed in 3D space to calculate the equivalent resistance and stray inductance in each commutation loop. Finally, the model and analysis results were put into a busbar design, simulation and experiments, whose results demonstrate the accuracy and feasibility of the proposed method.

Prediction of dryout-type CHF for rod bundle in natural circulation loop under motion condition

  • Huang, Siyang;Tian, Wenxi;Wang, Xiaoyang;Chen, Ronghua;Yue, Nina;Xi, Mengmeng;Su, G.H.;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.721-733
    • /
    • 2020
  • In nuclear engineering, the occurrence of critical heat flux (CHF) is complicated for rod bundle, and it is much more difficult to predict the CHF when it is in natural circulation under motion condition. In this paper, the dryout-type CHF is investigated for the rod bundle in a natural circulation loop under rolling motion condition based on the coupled analysis of subchannel method, a one-dimensional system analysis method and a CHF mechanism model, namely the three-fluid model for annular flow. In order to consider the rolling effect of the natural circulation loop, the subchannel model is connected to the one-dimensional system code at the inlet and outlet of the rod bundle. The subchannel analysis provides the local thermal hydraulic parameters as input for the CHF mechanism model to calculate the occurrence of CHF. The rolling motion is modeled by additional motion forces in the momentum equation. First, the calculation methods of the natural circulation and CHF are validated by a published natural circulation experiment data and a CHF empirical correlation, respectively. Then, the CHF of the rod bundle in a natural circulation loop under both the stationary and rolling motion condition is predicted and analyzed. According to the calculation results, CHF under stationary condition is smaller than that under rolling motion condition. Besides, the CHF decreases with the increase of the rolling period and angular acceleration amplitude within the range of inlet subcooling and mass flux adopted in the current research. This paper can provide useful information for the prediction of CHF in natural circulation under motion condition, which is important for the nuclear reactor design improvement and safety analysis.

Circulation Effect of the Transparent Insulated Opaque Envelopes (투명 단열외피를 통한 환기효과에 관한 연구)

  • Kim, S.H.;Kim, S.J.;Lee, S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.31-43
    • /
    • 2000
  • A model house with a "Ondol" heating working with solar energy and supplied by circulation air was investigated both experimentally and theoretically, A calculation method was developed for interpreting the measured values and for comparing several variants, This calculation method together with the measurement result is presented in the following. The gain in energy of the collector(Trombe wall type with TWD) measured on a particularly selected winter day with plenty of radiation amounted to approximately 31 % of the total solar radiation.

  • PDF

A Harmonic Circulation Current Reduction Method for Parallel Operation of UPS with a Three-Phase PWM Inverter

  • Kim Kyung-Hwan;Kim Wook-Dong;Hyun Dong-Suk
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.160-165
    • /
    • 2005
  • In a parallel operation of UPS, there are two types of circulating currents between UPS. One is the low order circulating current with a fundamental frequency caused by the amplitude and phase differences of UPS output voltages, and the other is the harmonic circulating current with PWM switching frequency caused by non-synchronized PWM waveforms among UPS. The elimination of the low order circulating current is essential for optimal load sharing in parallel operations of UPS, which can be accomplished by the phase and magnitude control at each UPS. The harmonic circulating current may cause troubles and deteriorate in performance of the controller for optimal load sharing in parallel operation of UPS. This paper presents a PWM synchronizing method to eliminate the harmonic circulation current in parallel operation of UPS. The effectiveness of the proposed scheme has been investigated and verified through experiments by a 50kVA UPS.