• 제목/요약/키워드: Circulation System

Search Result 1,709, Processing Time 0.03 seconds

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.

Design Methods of Intermittent Deep Draw Aeration System for Reservoir Water Quality Management (저수지의 수질 관리를 위한 간헐식 양수통형 인공 순환 장치의 설계 방법 개발)

  • Seo, Dongil;Song, Museok;Hwang, Hyundong;Lee, Eun-hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.445-452
    • /
    • 2004
  • Intermittent deep draw artificial circulation system is one of the most widely used destratification systems to control algal bloom in reservoirs in Korea. However, there have been neither theoretical background of design criteria nor operation guide line for efficient application of the system available for such systems. A design method was developed to calculate required compressor capacity and number of circulation units considering physical interactions between stratified water layers and plumes induced by the intermittent deep draw artificial circulation system. The program was tested with data observed in Yeoncho Lake. The results indicated that the developed method can applied in the fields successfully. Further validation processes would improve design and operation methods.

Effects of Logistics organization practices and Resources Circulation factor on Firm Performance (물류분야에서의 자원순환형시스템 구축 활동요인과 물류조직특성이 물류성과에 미치는 효과)

  • Lim, Jae-Hwa;Park, Seog-Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.1
    • /
    • pp.48-58
    • /
    • 2007
  • For a sustainable development, the resources circulation system should be established and required alternative logistics area of enterprises. In this paper, we are to suggest a direction through analysis effects, and reduce, recycle, reuse factor of transportation, material handling, packing, information, management in logistics function, and effects of logistics organization on Firm Performance. We found significant correlations between the constructs extracted above, and between the constructs and firm's performance. This study was conducted with the subjects of manufacturing enterprises with concurrent reviews of literature and statistical analysis, and the meaning of this study would be the analysis of the influencers of the resources circulation system.

An Experimental Study on Variable-Speed Control of an Ground-Water Circulation Pump for a Ground Source Multi-Heat Pump System (주거용 건물 지열원 멀티 히트펌프시스템의 지열순환펌프 가변유량제어에 관한 실증연구)

  • Song, Suwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.443-449
    • /
    • 2013
  • The purpose of this study is to propose an enhanced variable-speed control method of ground-water circulation pumps using inlet and outlet ground-water temperature difference and analyze its effect for the ground source multi-heat pump system installed in a single-family house. As a result, it has shown to significantly reduce the electricity use of ground-water circulation pump and improve overall system Coefficient of Performance (COP) due to the proposed variable-speed control under partial load conditions after oversized and inefficient single-speed pump retrofit.

A Study on the Spatial Interdependence in the Interior Space of Housing According to the Planning of Circulation System - Based on the Korean and German Cases - (통로공간의 구성체계에 따른 주거 내부공간의 상호결합특성에 관한 연구 - 한국과 독일의 주택 평면 사례를 중심으로 -)

  • 전남일
    • Korean Institute of Interior Design Journal
    • /
    • no.39
    • /
    • pp.83-91
    • /
    • 2003
  • The planning of circulation area and circulation path are very important elements for layout of interior space of housing. This study is, therefore, aimed at synthetical review of that area from a functional, structural and socio-cultural point of view as well as typological analysis of that area. In the interior space of housing the networking of spaces according to the circulation route imply divers aspects of independent or dependant significances. It is thus, closely related with to whether circulation area open or closed, whether circulation path concentrated or distributed, and whether it passes Individual rooms or not. With regard to relationship with public and private spaces, there are many grounds for combining each other. This study also tried to develope program for planning of circulation system, utilizing typological analysis of them. At the same time this study suggests examples for layout of housing spaces. It is expected that the results represented In the form of systematic diagram will deserve to be a tool for providing an appropriate solution to the problem of diversity of user's needs.

A COEX mall Case study on the Correlation between Circulation system and Environmental elements for a Better Wayfinding design in Mixed-use buildings (동선체계와 환경요소의 상관관계가 복합용도건물의 길찾기에 미치는 영향에 관한 코엑스몰 사례연구)

  • Park, MinJi;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.151-162
    • /
    • 2016
  • Various mixed-use buildings have been developed in the process of resolving the issue of 'urban regeneration' in the modern city. In this urban regeneration process, the size of the mixed-use buildings and the level of their functional complexity have been increased. It requires a quantitative and systematic approach in order to analyze the internal circulation flow within the large-scale commercial mixed-use buildings. Circulation system and environmental factors, respectively, have been vital criteria for the effectiveness of a Wayfinding design within the mixed-use buildings. The circulation system in this paper consists of 1) the number of the incoming paths at each node, and 2) the angle of directional transition from the incoming paths at the node. The environmental factors include 1) color tone, 2) materials, 3) lighting, and 4) pattern of the interior design of the mixed-use buildings. In this paper, the author develops a method of investigating the influence of the correlation between the circulation system and the environmental factors on the design of Wayfinding on the view of the remodeled COEX MALL interior design.

Effect of Suction Temperature and Compressor Frequency on Oil Circulation Ratio in a $CO_2$ Refrigeration System ($CO_2$ 냉동시스템에서 압축기의 흡입온도와 운전주파수가 오일 순환량에 미치는 영향)

  • Kim, Kyung-Jae;Lee, Ik-Soo;Kang, Byung-Ha;Kim, Suk-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.893-898
    • /
    • 2009
  • The quantity of discharged oil from a compressor is one of the most important issues for proper operation of refrigeration system. If the oil is increased in the system not only pressure drop is increased in other components, such as evaporator and gas cooler but also heat transfer coefficient in the heat exchangers is decreased. In addition, the lack of oil in the compressor may cause a critical of the system failure. In this study, one stage single rotary compressor is used for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Characteristics of oil circulation ratio have been investigated for $CO_2$ rotary compressor in the range of operation frequency 45 Hz to 63 Hz and the suction temperature range of $0^{\circ}C$ to $15^{\circ}C$. The results obtained indicate that the oil circulation ratio is increased as the suction temperature or compressor operating frequency is increased.

  • PDF

The Improvement of Circulation System in Theme Park - Focused on the EXPO Ocean Park in Yeosu - (주제공원의 동선 개선 제안 - 여수 엑스포 해양공원을 대상으로 -)

  • Park, Hyo-Chul;Han, Hye-Sun
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.5
    • /
    • pp.202-210
    • /
    • 2014
  • The EXPO Ocean Park in Yeosu has taken on the apsect of a theme park and has specialized facilities. But the outdoor circulation system that has been used by Expo 2012 Yeosu Korea still remained. These conditions can occur unused circulation and a long walk between facilities. The Purpose of this study is to suggest the improvement of circulation system that uses walking and outdoor space at the Expo Ocean Park in Yeosu. The following researches are drawn based upon the purpose. First, Definition and existing academic literature of theme park is considered. Second, the type, utilization condition, and circulation of outdoor facilities of Expo Ocean Park are investigated through the field survey and analysis. The field survey is conducted on the Expo Ocean Park in Yeosu for five times from October. 2013 to March. 2014. The data is collected through the photographed outdoor park and interviewing the staff of 2012 Yeosu World Expo Foundation. Third, the case study on outdoor circulation of waterside park and park with amusement facilities that are similar to Expo Ocean Park are examined. The result of this study is expected to seek sustainable management of Expo Ocean Park for maximizing local resident and visitors' satisfaction and improving effective park image. Since the field survey was conducted before the park is reopened and The Expo Ocean Park is on the improve through the this study at present, the verification of improvement scheme based on Post-Occupancy Evaluation(POE) is needed for future study.

A study on the Optimal Condition for Application with Extracorporeal Membrane Oxygenation (ECMO 시스템 적용을 위한 최적화 조건에 관한 연구)

  • Kim, Jae-Yeol;Song, Min-Jong;You, Sin;Ma, Sang-Dong;Kim, Chang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.13-18
    • /
    • 2001
  • The ECMO system, including umbilical cord and membrane type oxygenator was connected with extracorporeal circulation unit, was applied to the fetus growth model of goat. The maximum survival time of goat fetus was 48 hours. Average blood rate for the extracorporeal circulation was $223{\pm}15.2 ml/min.$ The survival time of fetus was deeply related to body temperature, blood circulation and water temperature, anesthetized time, and fetus weights. Extern variables that are composed of anesthetized time, fetus weights, change of hemoglobin, circuit pressure, related to the survival time for fetus corrected the problem of previous ECMO model that is controlled by roller pump. It is directly delivered to heart on load. Applying the results from new ECMO model, further research will provide to the system of ECMO for human.

  • PDF

Experimental study on natural circulation using liquid nitrogen for superconducting applications

  • Choi, Yeon Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.49-52
    • /
    • 2013
  • An experiment to investigate the natural circulation of a cryogen has been performed. The study is motivated mainly by our recent development of cryogenic cooling system for prototype superconducting cyclotron without any circulating pump. In the natural circulation loop system, a cooling channel is attached on the outer surface of the aluminium block and the liquid nitrogen passes through inside of the channel to cool the block indirectly. A cryocooler as a heat sink is located at the top to re-condense cryogenic vapor coming from the aluminium block in which electrical heater is installed as a heat source. The main dimensions are determined using the relevant analysis and the natural circulation loop is successfully fabricated. The temperature distributions in the loop are measured during initial cool-down process and in steady state, from which the modified Grashof numbers are calculated and compared with the existing correlation estimated with one-dimensional analysis for steady state flow.