• Title/Summary/Keyword: Circulating

Search Result 1,828, Processing Time 0.055 seconds

An Efficient Clamp to Reduce Switch Voltage Stress of Forward Converter (포워드 컨버터의 스위치 전압 스트레스 감소를 위한 효율적 클램프)

  • Kim, Marn-Go
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 2016
  • In this study, an efficient clamp is proposed to reduce the switch voltage stress of a forward converter. The proposed clamp consists of a conventional LC snubber, a tertiary winding, and a diode. When the switch is turned OFF, the magnetizing inductor energy of the transformer is recovered directly into the flyback output, which is the tertiary winding and diode network, instead of circulating in the LC snubber. Therefore, switch voltage stress and circulating current caused by the magnetizing inductor energy are reduced. This condition improves the efficiency of the forward converter with limited switch voltage stress. A theoretical analysis and the design guidelines of the proposed converter are provided. Experimental results are also reported.

A novel ZVS interleaved totem-pole PFC converter with reduced circulating current and diode reverse recovery current (순환전류와 다이오드 역회복 전류가 작은 인터리빙 방식의 새로운 ZVS 토템폴 PFC 컨버터)

  • ;Choe, U-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.189-191
    • /
    • 2018
  • This paper introduces a novel ZVS interleaved totem-pole PFC with the reduced circulating current and the reverse recovery current of the diodes. With the help of a simple auxiliary inductor, both ZVS turn-on of the main switches and soft turn-off of the body diodes can be achieved. In the proposed totem-pole PFC topology since the switching losses and the reverse recovery losses can be significantly reduced, the typical Si MOSFETs can be employed. In addition the circulating current is reduced by adjusting the switching frequency. The proposed PFC topology can be a low cost solution to achieve high efficiency in high power PFC applications. The validity and the feasibility of the proposed topology is verified by the experimental results with a 3.3kW interleaved totem-pole PFC converter.

  • PDF

Effects of Operating Variables on the Solid Circulation Rate in a Three-phase Circulating Fluidized Bed

  • Kim, Min Kon;Hong, Sung Kyu;Lim, Dae Ho;Yoo, Dong Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.440-444
    • /
    • 2015
  • Effects of operating variables on the solid circulation rate were investigated in a three-phase circulating fluidized bed, of which inside diameter was 0.102m and height was 3.5m, respectively. Gas velocity, primary and secondary liquid velocities, particle size and height of solid particles piled up in the solid recycle device were chosen as operating variables. The solid circulation rate increased with increasing primary and secondary liquid velocities and height of solid particles piled up in the solid recycle device, but decreased with increasing particle size. The value of solid circulation rate decreased only slightly with increasing gas velocity in the riser. The values of solid circulation rate were well correlated in terms of dimensionless groups within the experimental conditions.

Design and Performance Analysis of a Small Circulating Water Channel for Ocean Engineering (해양공학용 소형 회류수조 설계 및 성능분석)

  • Yim, Young-Bae;Jeong, Uh-Cheul;Park, Chan-Won;Hong, Ki-Sup
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.198-202
    • /
    • 2003
  • A small circulating water channel (CWC) for experiments ocean engineering is designed and made through the co-work of a company, MESTEC, and a college, Inha Technical Research Institute. General function of the elements of CWC are explained. The velocities in the test section are measured and analysed to estimate the performance of the CWC. The result of the velocity distribution is acceptable for experiments of ocean engineering.

  • PDF

Circulating Permeability Factors in Idiopathic Nephrotic Syndrome

  • Ha, Tae-Sun
    • Childhood Kidney Diseases
    • /
    • v.23 no.1
    • /
    • pp.7-21
    • /
    • 2019
  • Nephrotic syndrome (NS) is a common chronic glomerular disease in children characterized by significant proteinuria with resulting hypoalbuminemia, edema, and hyperlipidemia. Renal biopsy findings of diffuse foot processes effacement on electron microscopy and minimal change disease, focal segmental glomerulosclerosis (FSGS), or diffuse mesangial proliferation on light microscopy. It has been speculated that circulating permeability factors would be implicated in the pathogenesis of NS because they have been reportedly detected in the sera of patients and in experimental models of induced proteinuria. Moreover, a substantial portion of the patients with primary FSGS recurrence shortly after transplantation. This report reviews the current knowledge regarding the role of circulating permeability factors in the pathogenesis of proteinuria in NS and suggests future targeted therapeutic approaches for NS.

Novel Adaptive Virtual Impedance-based Droop Control for Parallel Operation of AC/DC Converter for DC Distribution (새로운 가상 임피던스 선정기법 기반의 적응 드룹을 이용한 직류배전용 AC/DC 컨버터의 병렬운전)

  • Lee, Yoon-Seong;Kang, Kyung-Min;Choi, Bong-Yeon;Kim, Mi Na;Lee, Hoon;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.328-329
    • /
    • 2020
  • The AC/DC converter, which connects the AC grid to the DC grid in the microgrid, is a critical component in power sharing and stable operation. Sometimes the AC/DC converters are connected in parallel to increase the transmission and reception capacity. When connected in parallel, circulating current is generated due to line impedance difference or sensor error. As a result of circulating current, there is deterioration and loss in particular PCS(Power Conversion System). In this paper, we propose droop control with novel adaptive virtual impedance for reducing circulating current. Feasibility of proposed algorithm is verified by PowerSIM simulation.

  • PDF

Role of Liquid Biopsies in Colorectal Cancer (대장암에서 액체 생검의 역할)

  • Kim, Sang Hyun;Keum, Bora
    • Journal of Digestive Cancer Research
    • /
    • v.8 no.1
    • /
    • pp.56-60
    • /
    • 2020
  • In recent years, liquid biopsy has received immense attention. Liquid biopsy is a minimally invasive method used for obtaining biological fluids including urine, pleural fluid and, mostly, peripheral blood. Liquid biopsy involves various targets including circulating tumors cells (CTCs), circulating cell-free tumor DNA (ctDNA), and microRNA (miRNA). Colorectal cancer (CRC), like other solid tumors, shed tumor cells into the bloodstream. Analysis of these CTCs, as well as ctDNA is the primary objective of the liquid biopsy. Evaluation of CTC or ctDNA offers information about early tumor release, development of tumor metastasis and also about mechanisms involved in tumor resistance to treatment.

Characteristics of Saturation and Circulating Current Based on Winding and Iron Core Structure of Grid-connected Transformer in Energy Storage System (ESS 연계용 변압기의 결선방식 및 철심구조에 따른 순환전류와 포화특성에 관한 연구)

  • Tae, Dong-Hyun;Lee, Hu-Dong;Kim, Ji-Myung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.39-48
    • /
    • 2020
  • Since the fire accident of ESS (energy storage system) occurred at Gochang KEPCO Power Testing Center in August 2017, 29 fire cases with significant property losses have occurred in Korea. Although the cause of fire accidents have not been identified precisely, it should be considered battery and PCS (power conditioning system) as well as unbalance issues in the distribution system. In particular, circulating currents in a neutral line of a grid-connected transformer, which can affect a magnetized current, may have a negative effect on the ESS with unintentional core saturation and surge voltages at the secondary side of the transformer. Therefore, this paper proposes the modeling of the distribution system, which was composed of a substation, grid-connected transformer, and customer loads using PSCAD/EMTDC S/W, to analyze the phenomena of circulating current and surge voltages of the transformer with unbalanced currents in the distribution system. This paper presents a countermeasure for a circulating current with the installation of NGR (neutral grounding resistor) in grid-connected transformer. From the simulation results, it is clear that exceeding the circulating current and surge voltage at the secondary side of the transformer can be one of the causes of fire accidents.

Changes of Nutrient Content of Circulating Solution in Three Different New Hydroponics for Oriental Melons(Cucumis melo L. var. makuwa Mak.) (참외용 수경재배시스템에서의 순환배양액의 무기이온 함량의 변화)

  • 조익환;전하준
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.168-174
    • /
    • 2002
  • A new circulating hydroponic system was invented for oriental melons grown in the greenhouse. For developing nutrient solution management techniques, we examined the changes of nutrient contents of circulating solution in three different types of new hydroponic systems. The yield and fruit quality of oriental melons in Hydroponics were better than those in soil culture. The substrate culture was appropriate fer hydroponics of oriental melons, and NFT was turned to be the opposite due to the physiological disorder during hot seasons. Yamazaki's melon solution with EC 2.0dS.m$^{[-10]}$ was the most appropriate for oriental melons. The new circulating hydroponic system seemed to be appropriate for oriental melons because of the stable EC, pH and the macro- and micro-element contents. NO$_3$-N, Ca and Mg contents in the circulating solution kept a good balance in all types of hydroponics. However, p content, compared to other types, decreased by the degree of 1 me.L$^{[-10]}$ in perlite medium. K content showed irregular status in perlite but showed the stable status in cocopeat. Generally, microelements, except Mo, showed stable absorption in the substrate culture. However, in NET, most of the elements showed irregular absorption except B and Mn. Microelement absorption, especially Cu, Zn and Mo, decreased during hot seasons.