• Title/Summary/Keyword: Circular array

Search Result 284, Processing Time 0.023 seconds

Measurement of Ultrasonic Field Propagation Characteristics in Biological Tissues Using a Two-dimensional Array Hydrophone (2차원 배열 수중청음기를 이용한 생체조직에서의 초음파 음장 전파특성 측정)

  • ;;;;Xiu-Fen Gong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.76-82
    • /
    • 2001
  • Because the biological tissue with inhomogeneous acoustic properties does not keep a particular shape, the measurement of propagation characteristics of ultrasonic fields by the conventional scanning method with a miniature hydrophone is difficult. In this study, a two-dimensional may hydrophone was fabricated using the PVDF (Polyvinylidene fluoride) piezo-electric film and a ultrasonic field measurement system with it was established. For the acoustic field produced by a circular plan transducer with center frequency of 2.25㎒ and 13㎜ in diameter, it was possible to make a fairly accurate field measurement using the hydrophone system. The attenuation coefficients at 2.25 ㎒ for biological tissues were 0.7∼1.3 dB/cm(average; 1.0 dB/cm) in bovine liver, 1.0∼1.8 dB/cm (average; 1.6 dB/cm) in pig liver, 0.9∼2,9 dB/cm(average: 2.1 dB/cm) in bovine muscles, 1.7∼3.3 dB/cm (average; 2.5 dB/cm) in pig muscles.

  • PDF

Complete genome sequence of multidrug-resistant Moraxella osloensis NP7 with multiple plasmids isolated from human skin (사람의 피부에서 분리한 다약제 내성이며 다수의 플라스미드를 갖는 Moraxella osloensis NP7 균주의 유전체 서열 분석)

  • Ganzorig, Munkhtsatsral;Lim, Jae Yun;Hwang, Ingyu;Lee, Kyoung
    • Korean Journal of Microbiology
    • /
    • v.54 no.3
    • /
    • pp.286-288
    • /
    • 2018
  • Moraxella osloensis NP7 was isolated from human skin of a collage male and showed resistance to ${\beta}-lactam$ and aminoglycoside antibiotics. Herein, we report the complete whole-genome sequence and gene annotations of M. osloensis NP7. It possesses single circular chromosome and seven plasmids. Chromosome is 2,389,582 bp in length with the G + C content of 43.9% and encodes 2,065 protein-coding genes. The combined seven plasmids are 654,202 bp in size with the average G + C content of 40.5% and code for a total of 667 protein-coding genes. The chromosome of NP7 strain contains four ribosomal RNA operon copies, one transfer-messenger RNA gene, forty-seven tRNA genes, three riboswitch genes and three CRISPR arrays. Additional CRISPR array is found in the plasmid pNP7-1. The genes conferring resistance to ${\beta}-lactam$ and aminoglycoside antibiotics were predicted to reside in the plasmid pNP7-1.

Hand Gesture Recognition Regardless of Sensor Misplacement for Circular EMG Sensor Array System (원형 근전도 센서 어레이 시스템의 센서 틀어짐에 강인한 손 제스쳐 인식)

  • Joo, SeongSoo;Park, HoonKi;Kim, InYoung;Lee, JongShill
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.371-376
    • /
    • 2017
  • In this paper, we propose an algorithm that can recognize the pattern regardless of the sensor position when performing EMG pattern recognition using circular EMG system equipment. Fourteen features were extracted by using the data obtained by measuring the eight channel EMG signals of six motions for 1 second. In addition, 112 features extracted from 8 channels were analyzed to perform principal component analysis, and only the data with high influence was cut out to 8 input signals. All experiments were performed using k-NN classifier and data was verified using 5-fold cross validation. When learning data in machine learning, the results vary greatly depending on what data is learned. EMG Accuracy of 99.3% was confirmed when using the learning data used in the previous studies. However, even if the position of the sensor was changed by only 22.5 degrees, it was clearly dropped to 67.28% accuracy. The accuracy of the proposed method is 98% and the accuracy of the proposed method is about 98% even if the sensor position is changed. Using these results, it is expected that the convenience of the users using the circular EMG system can be greatly increased.

A Study on Key Arrangement of Virtual Keyboard based on Eyeball Input system (안구 입력 시스템 기반의 화상키보드 키 배열 연구)

  • Sa Ya Lee;Jin Gyeong Hong;Joong Sup Lee
    • Smart Media Journal
    • /
    • v.13 no.4
    • /
    • pp.94-103
    • /
    • 2024
  • The eyeball input system is a text input system designed based on 'eye tracking technology' and 'virtual keyboard character-input technology'. The current virtual keyboard structure used is a rectangular QWERTY array optimized for a multi-input method that simultaneously utilizes all 10 fingers on both hands. However, since 'eye-tracking technology' is a single-input method that relies solely on eye movement, requiring only one focal point for input, problems arise when used in conjunction with a rectangular virtual keyboard structure designed for multi-input method. To solve this problem, first of all, previous studies on the shape, type, and movement of muscles connected to the eyeball were investigated. Through the investigation, it was identified that the principle of eye movement occurs in a circle rather than in a straight line. This study, therefore, proposes a new key arrangement wherein the keys are arranged in a circular structure suitable for rotational motion rather than the key arrangement of the current virtual keyboard which is arranged in a rectangular structure and optimized for both-hand input. In addition, compared to the existing rectangular key arrangement, a performance verification experiment was conducted on the circular key arrangement, and through the experiment, it was confirmed that the circular arrangement would be a good replacement for the rectangular arrangement for the virtual keyboard.

Fabrication of Combined Probes for Interstitial hyperthermia and Brachyradiotherapy (고 선량율 근접 및 온열치료 병용 삽입관의 제작과 특성)

  • Chu, Sung-Sil;Kim, Sung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.85-87
    • /
    • 2004
  • We fabricated flexible thermoradiotherapy probes to alternated combination with Interstitial hyperthermia and Brachyradiotherapy thermoradiotherapy probe was coated by gold plate on polyethylene brachytherapy probe. When Agar phantom was heated 15 minute with 30 W radiofrequency power, temperature increased as 5oC for polyethylene probe and 20oC for gold coated polyethylene probe. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures (90% relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature (90% relative SAR using Tm). The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50 min to generate tissue temperatures of 43${\circ}$C. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from 7${\sim}$30 days. The acute stage was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (days30)canine brain.

  • PDF

A study on the Enhancement of Gain and Axial Ratio Bandwidth of the Multilayer CP-DRA (다층 CP-DRA의 이득 및 축비대역폭 증대에 관한 연구)

  • Lee, Ho-Sang;Jo, Dong-Ki;Jung, Young-Ho;Kim, Cheol-Bok;Son, Ho-Cheol;Lee, Mun-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.7
    • /
    • pp.52-60
    • /
    • 2009
  • In this pater, a CP-DRA(Circularly Polarized Dielectric Resonator Antenna) using cross-slot-feed is studied to enhance the gain and axial ratio bandwidth. First, a single layer CP-DRA is studied as a reference for comparison. Then a new type of multilayer CP-DRA is proposed to enhance the gain and axial ratio bandwidth. In consideration of the antenna gain enhancement, the spacing between the elements of the multilayer CP-DRA is examined through analysis of the radiation performance of a 2$\times$2 planar amy of DRAs with a spacing of 0.7$\lambda_0$ and 1.2$\lambda_0$ using CST Microwave Studio. The measured result shows that the gain and bandwidth of the multilayer structure is approximately twice that of the single layer one. In the case of the array antenna in which the spacing between multilayer CP-DRA element is 1.2$\lambda_0$, a grating lobe is reduced, in contrast to what we can expect from a conventional antenna array. The gain is 13.4dBi and axial ratio bandwidth is 0.8GHz.

Temperature Measurement of Flip Chip Joints with Peripheral Array of Solder Bumps (페리퍼럴어레이 플립칩의 온도 분포 특성)

  • Cho Bon-Goo;Lee Taek-Yeong;Lee Jongwon;Kim Jun-Ki;Kim Gangbeom
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.3 s.36
    • /
    • pp.243-251
    • /
    • 2005
  • The distribution of temperature of flip chipped device with peripheral solder bump array was measured with variables, such as the locations and geometries of heater, the size of device, the size of passivation opening. The highest temperature was measured with the larger device, $3.0(mm)\times3.0(mm)$, which has the smallest heater at the center of device and the circular passivation opening. For 2 (watts) power input, the device shows the highest temperature of about $110(^{\circ}C)$. In contrast, the smaller device, $1.5(mm)\times1.8(mm)$, shows that of $90(^{\circ}C)$. In addition to the size effect, the increase of passivation opening size decreased the maximum temperature by about $10(^{\circ}C)$. From the measurement, the temperature of device could be controlled with the size and geometry of heater, the size of device and the size and geometry of passivation opening.

  • PDF

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

  • Fiser, Ondrej;Merunka, Ilja;Vrba, Jan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1744-1753
    • /
    • 2016
  • The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the treatment planning based on the optimization process made through the SEMCAD X software is added to show the steering possibilities of SAR and thereby temperature distribution. Using treatment planning software, we proved that the SAR and temperature distribution can be effectively controlled (by amplitude and phase changing) improving the SAR and temperature target coverage approximately by 20 %. For the proposed applicator system analysis and quantitative evaluation of two parameters 25 % iso-SAR and $41^{\circ}C$ iso-temperature contours in the treatment area with the respect to sensitive structures in treatment area were defined. To verify our simulation results, the real measurement of reflectivity coefficient as well as the temperature distribution in a homogenous phantom were performed.

Effect of Arrays of Impinging Jets with Crossflow on Heat/Mass Transfer (배열충돌제트에서 횡방향유동성분에 따른 열/물질전달 특성 고찰)

  • Yoon, Pil-Hyun;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.195-203
    • /
    • 2000
  • The local heat/mass transfer coefficients for arrays of impinging circular air jets on a plane surface are determined by means of the naphthalene sublimation method. Fluid from the spent jets is constrained to flow out of the system in one direction. Therefore, the spent fluid makes a crossflow in the confined space. The present study investigates effects of jet-orifice-plate to impingement-surface spacing and jet Reynolds number. The spanwise- and overall-averaged heat/mass transfer coefficients are obtained by numerical integrating the local heat transfer coefficients. The local maximum heat/mass transfer coefficients move further in the downstream direction due to the increase of crossflow velocity. At the mid-way between adjacent jets, the heat/mass transfer coefficients have a small peak owing to the collision of the adjacent wall jets and are affected strongly by the crossflow. The effect of the crossflow occurs strongly at the small orifice-to-impingement surface distance.

SOLAR ACTIVE REGION STUDY USING MICROWAVE MAPS

  • BONG SU-CRAN;LEE JEONGWOO;GARY DALE E.;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.spc1
    • /
    • pp.29-36
    • /
    • 2003
  • Quiescent solar radiation, at microwave spectral regime, is dominated by gyroresonant and thermal Bremsstrahlung radiations from hot electrons residing in solar active region corona. These radiations are known to provide excellent diagnostics on the coronal temperature, density, and magnetic field, provided that spatially resolved spectra are available from observations. In this paper we present an imaging spectroscopy implemented for a bipolar active region, AR 7912, using the multifrequency interferometric data from the Owens Valley Solar Array (OVSA), as processed with a new imaging technique, so-called Spatio-Spectral Maximum Entropy Method (SSMEM). From the microwave maps at 26 frequencies in the range of 1.2-12.4 GHz at both right- and left-circular polarizations, we construct spatially resolved brightness spectra in every reconstructed pixel of about 2 arcsec interval. These spectra allowed us to determine 2-D distribution of electron temperature, magnetic field of coronal base, and emission measure at the coronal base above the active region. We briefly compare the present result with existing studies of the coronal active regions.