• Title/Summary/Keyword: Circuit testing

Search Result 419, Processing Time 0.026 seconds

Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경)

  • Jeung Jae Yeal;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

Reliability of Sn-Ag-Cu Solder Joint on ENEPIG Surface Finish: 1. Effects of thickness and roughness of electroless Ni-P deposit (ENEPIG 표면처리에서의 Sn-Ag-Cu 솔더조인트 신뢰성: 1. 무전해 Ni-P도금의 두께와 표면거칠기의 영향)

  • Huh, Seok-Hwan;Lee, Ji-Hye;Ham, Suk-Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.43-50
    • /
    • 2014
  • By the trends of electronic package to be smaller, thinner and more integrative, the reliability of interconnection between Si chip and printed circuit board is required. This paper reports on a study of high speed shear energy of Sn-4.0wt%Ag-0.5wt%Cu (SAC405) solder joints with different the thicknesses of electroless Ni-P deposit. A high speed shear testing of solder joints was conducted to find a relationship between the thickness of Ni-P deposit and the brittle fracture in electroless Ni-P deposit/SAC405 solder. A focused ion beam (FIB) was used to polish the cross sections to reveal details of the microstructure of the fractured pad surface with and without $HNO_3$ vapor treatment. The high speed shear energy of SAC405 solder joint with $1{\mu}m$ Ni-P deposit was found to be lower without $HNO_3$ vapor, compared to those of over $3{\mu}m$ Ni-P deposit. This could be due to the edge of solder resist in $1{\mu}m$ Ni-P deposit, which provides a fracture location for the weakened shear energy of solder joints and brittle fracture in high speed shear test. With $HNO_3$ vapor, the brittle fracture mode in high speed shear test decreased with increasing the thickness of Ni-P deposit. Then the roughness (Ra) of Ni-P deposits decreased with increasing its thickness. Thus, this gives the evidence that the decrease in roughness of Ni-P deposit for Eelectroless Ni/ Electroless Pd/ Immersion Au (ENEPIG) surface play a critical role for improving the robustness of SAC405 solder joint.

Analysis of Elements for Efficiencies in Magnetically-Coupled Wireless Power Transfer System Using Metamaterial Slab (메타물질 Slab이 포함된 자계 결합 무선 전력 전송 시스템 효율 요소 분석)

  • Kim, Gunyoung;Oh, TaekKyu;Lee, Bomson
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1128-1134
    • /
    • 2014
  • In this paper, the effects of a metamaterial slab with negative permeability in a magnetically coupled wireless power transfer system (WPT) in the overall performance are analyzed quantitatively in terms of the effective quality factors of the loop resonators and coupling coefficient considering the slab losses, based on an equivalent circuit. Using the ideal metamaterial slab(lossless slab), the WPT efficiency is improved considerably by the magnetic flux focusing. However, the practical lossy slab made of RRs or SRRs limits the significant enhancement of WPT efficiency due to the relatively high losses in the slab consisting of RRs or SRRs near the resonant frequency. For the practical loop resonator, other than a point magnetic charge, using the practical lossy metamaterial slab in order to improve the transfer efficiency, the width of the slab needs to be optimized somewhat less than the half of the distance between two loop resonators. For the low-loss slab with its loss tangent of 0.001, the WPT efficiency is maximized at 93 % when the ratio of the slab width and the distance between the two resonators is approximately 0.35, compared with 53 % for the case without the slab. The efficiency in case of employing the high-low slab(loss tangent: 0.2) is maximized at 61 % when the slab ratio is 0.25.

A Study on the Confirmation of non-flammabikity of the Cast Resin Mold Transformer in Subway Substation (지하철 변전실용 진공주형형 몰드변압기의 난연성 확인에 관한 연구)

  • 정용기;장성규;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • This dissertationhas confirmed the non-flam mability of cast mold transformer that is increasingly used lately. As a research progress, the investigation has been performed on the installation status and each line of the subway system which have the most mold transformer accidents, and the impediment status of the transformer for rectifier and the high-voltage distribution transformer per each manufacturer. Then, a high voltage mold of the actual mold transformer has been installed in the horiwntal heating furnace and the heat has been applied by the standard heating temperature curve of KSF 2257(Fireproof testing meth od of the construction structures: 1993). Accordingly, the combustibility of the mold transformer based on the test results has been found that 78 minutes has been required for the complete burning per the KSF 2257 combustion test curve and that, after stopping the heat application of the horizontal furnace after ignition, the flame progress has not been made but shown as the self-extinguishing characteristics when the flame progress has been checked. Thus, the non-flammability and self-extinguishability of the mold transformer have been confirmed. The result of this dissertation has indicated that the accident involving mold transformer has been progressed and expanded by the dielectric breakdown or void due to the crack in the mold rather than a fire accident caused by a short-circuit or an overload.r an overload.

  • PDF

Design of 256Kb EEPROM IP Aimed at Battery Applications (배터리 응용을 위한 1.5V 단일전원 256Kb EEPROM IP 설계)

  • Kim, Young-Hee;Jin, RiJun;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.558-569
    • /
    • 2017
  • In this paper, a 256Kb EEPROM IP aimed at battery applications using a single supply of 1.5V which is embedded into an MCU is designed. In the conventional cross-coupled VPP (boosted voltage) charge pump using a body-potential biasing circuit, cross-coupled PMOS devices of 5V in it can be broken by the junction or gate oxide breakdown due to a high voltage of 8.53V applied to them in exiting the program or erase mode. Since each pumping node is precharged to the input voltage of the pumping stage at the same time that the output node is precharged to VDD in the cross-coupled charge pump, a high voltage of above 5.5V is prevented from being applied to them and thus the breakdown does not occur. Also, all erase, even program, odd program, and all program modes are supported to reduce the times of erasing and programming 256 kilo bits of cells. Furthermore, disturbance test time is also reduced since disturbance is applied to all the 256 kilo bits of EEPROM cells at once in the cell disturb test modes to reduce the cell disturbance testing time. Lastly, a CG driver with a short disable time to meet the cycle time of 40ns in the erase-verify-read mode is newly proposed.

Effect of Individualized Exercise Program for Preventing Metabolic Syndrome among IT Company Office Workers (IT 기업 사무직 근로자의 대사증후군 예방을 위한 맞춤형 운동프로그램의 효과)

  • Kyungun Bae;Sung Hyun You;Dabi Shin;Yuncheol Ha;Hongmin Kim;Byungchan Pak;Hyosang Kim;Shinae Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.77-84
    • /
    • 2024
  • Objectives: Interventions promoting physical exercise and healthy habits in workplaces have been shown to be effective in reducing risk factors for metabolic syndrome. This study was conducted to examine the effects of an individualized conditioning exercise program of IT company office workers with or at higher risk of metabolic syndrome. Methods: A total of 444 IT company office workers with or at higher risk of metabolic syndrome participated in a 3-month conditioning exercise program. Body composition data using bioelectrical impedance analysis and cardiopulmonary data using cardiopulmonary exercise testing from 53 individuals (mean age: 34.8 ± 7.1 years, sex : 21% female, height : 170.4 ± 6.8 cm, weight : 75.2±12.2 kg, body mass index : 25.8±3.3 kg/m2) who have successfully completed pre-test, intervention, and post-test were analyzed. The 12 weeks intervention encompassed: (1) health counseling (2) supervised exercise(endurance-based, aerobic exercise, or circuit training once a week for 50 minutes at heart rate reserve(HRR) of 77-95%) (3) self-directed exercise and biweekly health screening checks. Results: The results indicated a significant decrease in body weight, body fat mass and body mass index, respectively. Moreover, VO2peak, AT VO2 and AT Time significantly improved, respectively. Resting blood pressure(SBP/DBP) showed positive changes but were not statistically significant. We observed the correlation between characteristics of participants and rate of changes in cardiopulmonary outcomes of participants, there are no significant correlation. These results indicate positive changes in body composition and cardiorespiratory fitness parameters following individualized conditioning exercise program. Conclusions: Individualized workplace exercise program for preventing metabolic syndrome can lead to improvements in body composition and cardiorespiratory fitness.

Particle Size Analysis of Cadmium Aerosol for Cadmium Inhalation Toxicology Study (766ppm Cadmium Nebulizing Solution) (카드뮴의 흡입독성 연구를 위해 설계된 에어로졸 발생장치에서 발생된 카드뮴 에어로졸의 입경분석(766ppm 카드뮴 네뷸라이징 용액))

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Jahng Doo Sub;Kang Sung He;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.5
    • /
    • pp.1035-1041
    • /
    • 2002
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit and 766ppm Cd nebulizing solution were used to generate cadmium aerosol for inhalation toxicology study. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 43.449 x 10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 43.211 x 10³ in inlet temperature 100 ℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 41.917x10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter(GMD) were 0.677-1.009㎛ in source temperature 20℃, 0.716-0.963㎛ in source temperature 50℃, and 0.724-0.957㎛ in source temperature 70℃. The smallest GMD was 0.677㎛ in source temperature 20℃ and inlet temperature 20℃. and the largest GMD was 1.009㎛ in source temperature 20℃ and inlet temperature 20℃. The ranges of geometric standard deviation(GSD) were 1.635-2.101 in source temperature 20℃. 1.676-2.073 in source temperature 50℃, and 1.687-2.051 in source temperature 70℃. The lowest GSD was 1.635 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.101 in source temperature 20℃ and inlet temperature 200℃. Aerosol generated for cadmium inhalation toxicology study was polydisperse aerosol. The ranges of mass median diameter(MMD) were 1.399-5.270㎛ in source temperature 20℃. 1.593-4.742㎛ in source temperature 50℃, and 1.644-4.504㎛ in source temperature 70℃. The smallest MMD was 1.399㎛ in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 5.270㎛ in source temperature 20℃ and inlet temperature 200℃. Increasing trends for GMD, GSD, and MMD were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4㎛. In our results. inlet temperature 20 and 50℃ in source temperature 20℃, and inlet temperature 20 to 150℃ in source temperature 50 and 70℃ were conformed to the EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3㎛. In our results, inlet temperature 20 and 50℃ in source temperature 20, 50, and 70℃ were conformed to the OECD and EU guidance.

Particle Size Analysis of Lead Aerosol with the use of 2730ppm Lead Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구를 위한 2730ppm 납 네뷸라이징 용액에서 발생된 에어로졸의 입경분석)

  • Jeung Jae Yeal;Kang Sung Ho;Kim Sam Tae;Lee Eun Kyoung;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.518-524
    • /
    • 2003
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit was made for lead inhalation toxicology study and 2730ppm lead nebulizing solution was used to generate lead aerosol. After modification of source and inlet temperatures, the results of particle size analysis for lead aerosol were as following. The highest particle counting for source temperature 20℃ was 39933.66 in inlet temperature 100℃ and particle diameter 0.75tLm. The highest particle counting for source temperature 50℃ was 39992.71 in inlet temperature 250℃ and particle diameter 0.75μm. The highest particle counting for source temperature 70℃ was 37569.55 in inlet temperature 50℃ and particle diameter 0.75μm. The ranges of geometric mean diameter(GMD) were 0.754-0.784μm for source temperature 2℃, 0.758-0.852μm for source temperature 50℃, and 0.869-1.060μm for source temperature 70℃. The smallest GMD was 0.754μm in source temperature 20℃ and inlet temperature 20℃, and the largest GMD was 1.060μm in source temperature 70℃ and inlet temperature 250℃. The ranges of geometric standard deviation(GSD) were 1.730-1.782 for source temperature 20℃, 1.734-1.894 for source temperature 50℃, and 1.921-2.148 for source temperature 70℃. The lowest GSD was 1.730 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.148 in source temperature 70℃ and inlet temperature 250℃. Lead aerosol generated in this study was polydisperse. The ranges of mass median diameter(MMD) were 1.856-2.133μm for source temperature 20℃, 1.877-2.894μm for source temperature 50℃, and 3.120-6.109μm for source temperature 70℃. The smallest MMD was 1.856μm in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 6.109μm in source temperature 70℃ and inlet temperature 250℃. Slight increases for GMD, GSD, and MMD values were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but inlet temperature 20℃ and 50℃ for source temperature 70℃ were conformed EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3μm. In this study, source temperature 20℃ and 50℃ with inlet temperature from 20℃ to 250℃ were conformed to the EPA guidance, but none for source temperature 70℃.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.