• Title/Summary/Keyword: Circuit pressure

Search Result 536, Processing Time 0.048 seconds

Calculation of Pressure Rise in the Puffer Cylinder of EHV GCB Without Arc (무부하시의 초고압 GCB의 파퍼실린더 내부의 상승압력 계산)

  • Park, K.Y.;Song, K.D.;Choi, Y.K.;Shin, Y.J.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1559-1561
    • /
    • 1994
  • At present, the principle of puffer action in high current interruption is adopted in almost of the EHV(Extra High Voltage) and UHV(Ultra High Voltage) GCB(Gas Circuit Breakers). The thermal interruption capability of these GCBs critically depends on the pressure rise in the puffer cylinder at current zero. The pressure rise in the puffer cylinder depends on the puffer cylinder volume, flow passage and leakage area in the interrupter, stroke curve etc. Recently commercial CFD(Computational Fluid Dynamics ) packages have been widely adopted to calculate the pressure distribution in the interrupter. However, there are still several problems with it, e.g. very expensive price, moving boundary problem, computation time, difficulty in using the package etc. Thus, the calculation of the puffer cylinder pressure in simple and relatively correct method is essential in early stage of GCB design. In these paper, the model ing technique and computed results for EHV class GCB (HICO, 145kV 40kA and 362kV 40kA GCB) are presented and compared with available measured results.

  • PDF

Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change (커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현)

  • Jeong, Do-Un;Bae, Jin-Woo;Shon, Jung-Man;Yae, Su-Yung;Choi, Byeong-Cheol;Nam, Ki-Gon;Kim, Cheol-Han;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

A Study on Dynamic Characteristics of EFPCD for Electrical Fire Prevention (전기화재 예방을 위한 EFPCD동작 특성에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.8-11
    • /
    • 2002
  • Recently, the spark and the overheat due to in the failure of pressure contacts on connecting points and the momentary short circuit have been the major causes of electrical fire because these may cause the deposition and the graphite of insulating materials in electrical wiring system. Also, because in these cases the current is a surge one, the losses and faults of a communication, a home appliances, a computer and a measuring instrument may occur. Especially, in such cases, we are very difficult to detect the failure of pressure contacts on connecting points and the momentary short circuit. In this paper, we have developed an auxiliary control device, the electrical fire prevention control device(EFPCD), of an earth leakage breaker(ELB). And we can pre-vent the electrical fire caused by the spark and the overheat occurring in the failure of pressure contacts in connecting points and the momentary short circuit with the EFPCD.

Development of a Tractor Attached Round Bale Wrapper(I) -Analysis of wrapping process and development of operating system- (트랙터 견인형 원형 베일 랩퍼의 개발(I) -랩핑 작업공정 분석 및 작업 시스템의 개발-)

  • Park, K. K.;Kim, H. J,;Kim, C. S.;Kim, J. Y.;Kim, J. H.;Jang, C.
    • Journal of Biosystems Engineering
    • /
    • v.27 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • One of the major obstructing factors against managing dairy farm in Korea has been a shortage of roughage supply, which resulted in excessive abuse of concentrate feed. In order to solve this problem, production of the wrap silage by the winter cereal forages raised in the fallow paddy field is strongly recommended in Korea. The main objective is to develop a tractor attached round bale wrapper which can process the silage by wrapping the round bales with thin plastic films. This is the first half of the study which is divided by two parts. In this first part, bale wrapping process was analyzed, and based on this results the followings were designed, developed and tested. 1. Bale wrapper which haying the maximum capacity of 1 ton bale with various functions such as loading, wrapping, discharging the round bales and supplying and cutting wrap films was designed. 2. An actuator and its hydraulic circuit of each process were developed and tested. 3. Also, the variations of hydraulic pressure and engine speed were investigated by operating bale wrapper developed. In this test, maximum pressure of the hydraulic circuit for the bale wrapping was 130 kg/㎠ when it raised the bale, which was quite below the relief pressure of 170 kg/㎠ of hydraulic circuit. In the engine speed test, speed drop was 20∼67 rpm, which meant that there was no over-load operation. Therefore, the experiment proved that developed hydraulic circuit and mechanism is stable in bale wrapping operation

A study on the effect of injection pressure and ambient pressure for the growth of impinging spray (충돌 분무의 성장에 미치는 분사압과 배압의 영향에 관한 연구)

  • Cha, Geon-Jong;Seo, Gyeong-Il;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.11
    • /
    • pp.1458-1465
    • /
    • 1997
  • This study investigated the effects of pressure on the growth of an impinging spray. We obtained the frozen images which were scattered by Nd ; YAG laser light (pulse width : 7 ns) using synchronization circuit made in the laboratory. For an impinging spray a growth of the penetration length was progressed with increase of the injection pressure but an ambient pressure restrained its growth. The effect of an ambient pressure on penetration was larger than that of an injection pressure. The pressure ratio had an effect on the penetration growth rate. The thickness growth rate depended on both the injection pressure and the ambient pressure compositively. A lower injection pressure or a higher ambient pressure was required for spatial distribution of impinging spray.

Enhanced PSPICE Circuit Model for Vented-Box Loudspeaker System (PSPICE를 이용한 개선된 벤트박스 스피커 시스템 모델링)

  • Park, Seok-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.8
    • /
    • pp.757-765
    • /
    • 2007
  • Enhanced PSPICE circuit model for vented-box loudspeaker system with lumped parameters was proposed to more accurately simulate real vented-box loudspeaker system. Frequency dependent parameters were used to model voice coil inductor. Acoustic pressure response curves and electrical impedance curves were simulated and investigated by PSPICE circuit model according to circuit parameters' variations. Finally, it was used to identify faults detection in woofers manufactured by unskilled persons.

Prediction of Performance considering Ablated PTFE in High Voltage Self-blast Circuit Breaker (PTFE 용삭을 고려한 초고압 복합소호 차단기의 성능 예측)

  • Kim, Jin-Bum;Kweon, Ki-Yeoung;Lee, Hahk-Sung
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.695-698
    • /
    • 2008
  • Self-blast circuit breakers utilize the energy dissipated by the arc itself to create the required conditions for arc quenching during the current zero. During the arcing period, high pressure, temperature and radiation of the arc could burn in pure SF6 gas and PTFE nozzle. Ablated nozzle shape and $SF_6$-PTFE mixture vapor affect the performance of an self-blast circuit breaker. After a number of tests, nozzle in circuit breaker is disassembled, a section of ablated nozzle is investigated precisely. Using computational fluid dynamics, the conservation equation for the gas and temperature, velocity and electric fields within breaker is solved. Before applying a section model, developed program is verified with experimental data. Performance of ablated nozzle shape is compared with original model through analysis program.

  • PDF

Perspective of industrial application of high pressure and low temperature plasma

  • Kogoma, Masuhiro;Tanaka, Kunihito
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.378-383
    • /
    • 2001
  • An out line of the material process with using the atmospheric pressure glow plasma is described as follows : (1) TiO powder coating with SiO$_2$ (2) Surface treatment of Fluorinated polymers and (3) Surface cleaning of electronic circuit board with using splay type.

  • PDF

A Finite Element Analysis of Electromagnetic Forming for Tube Expansion (전자기 확관성형의 유한요소 해석)

  • 이성호;이동녕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1872-1885
    • /
    • 1991
  • The analysis of electromagnetic forming process consists of the analysis of the electric circuit and the dynamic deformation analysis. The purpose of the electric circuit analysis is to calculate the magnetic pressure and to apply it to the deformation analysis. Some investigators performed the analysis assuming the pressure distribution in longitudinal direction. However there was a difference between the calculated and experimental results. The difference mainly came from the assumption of the pressure distribution. One must know the magnetic field distribution in an actual situation for the analysis to be less erroneous. In this work the electromagnetic field analysis was performed by the finite element method to obtain a more realistic pressure distribution. A better agreement between the calculated and experimental results was obtained. It became possible to predict the deformation behavior of the workpiece of finite length.

A Two-dimensional Steady State Simulation Study on the Radio Frequency Inductively Coupled Argon Plasma

  • Lee, Ho-Jun;Kim, Dong-Hyun;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.5
    • /
    • pp.246-252
    • /
    • 2002
  • Two-dimensional steady state simulations of planar type radio frequency inductively coupled plasma (RFICP) have been performed. The characteristics of RFICP were investigated in terms of power transfer efficiency, equivalent circuit analysis, spatial distribution of plasma density and electron temperature. Plasma density and electron temperature were determined from the equations of ambipolar diffusion and energy conservation. Joule heating, ionization, excitation and elastic collision loss were included as the source terms of the electron energy equation. The electromagnetic field was calculated from the vector potential formulation of ampere's law. The peak electron temperature decreases from about 4eV to 2eV as pressure increases from 5 mTorr to 100 mTorr. The peak density increases with increasing pressure. Electron temperatures at the center of the chamber are almost independent of input power and electron densities linearly increase with power level. The results agree well with theoretical analysis and experimental results. A single turn, edge feeding antenna configuration shows better density uniformity than a four-turn antenna system at relatively low pressure conditions. The thickness of the dielectric window should be minimized to reduce power loss. The equivalent resistance of the system increases with both power and pressure, which reflects the improvement of power transfer efficiency.