• 제목/요약/키워드: Circuit interrupter

검색결과 100건 처리시간 0.018초

자기 액츄에이터를 이용한 진공차단기 구동 메카니즘 개발 (Development of VCB Driving Mechanism using Permanent Magnetic Actuator)

  • 최명준;석복렬;김창욱;최영찬;박일한
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.381-389
    • /
    • 2003
  • Nowadays, Vacuum Circuit Breaker(VCB) is used in the most medium voltage level because vacuum has environment-friendly characteristics as well as excellent dielectric strength. In order to elevate the breaking performance, the improvement of vacuum interrupters and the driving mechanism should be proceeded. In this paper, the development of a Permanent Magnet Actuator could replace the mechanical spring mechanism which is the driving mechanism of existing VCB. The holding force and opening characteristics of magnetic actuator are analysed with FEM and the result is verified through experiment.

지그비 네트워크 기반 복합형 AFCI 설계 및 구현 (Design and Implementation of a ZigBee Nework-based Integrated AFCI)

  • 장기흥;김기민;김재오;안현식
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.41-48
    • /
    • 2010
  • 전기적 위험요소인 아크고장, 과전류, 누설전류, 온도 등을 마이크로콘트롤러를 이용하여 실시간 감시할 수 있는 복합형 AFCI(Arc Fault Circuit Interrupter, 아크고장 차단기)를 설계 구현하며, 지그비(ZigBee)기반 네트워크를 구성함으로써 아크고장에 의한 전기화재의 위험성을 예측할 수 있는 시스템을 제안한다. 복합형 아크고장 차단기는 미국의 AFCI의 인증 규격인 UL1699의 시험 조건과 KS C 규격에서 요구하는 배선용차단기와 누전차단기의 규격을 만족시키며, 검출된 전기적 위험신호들을 분류하고 전송할 수 있는 복합형 AFCI를 네트워크의 종단에 설치하고, 화재의 위험요소들의 발생 상황을 분석함으로써, 화재 위험성을 방지하기 위한 예측 시스템의 구현에 관한 연구이다.

화재방지제어 시스템 IC (A System IC for Controlling the Fire Prevention)

  • 김병철
    • 한국정보통신학회논문지
    • /
    • 제13권4호
    • /
    • pp.737-746
    • /
    • 2009
  • 본 연구에서는 정보가전기기에서 과부하를 방지하고 이상신호를 검출하며 화재방지를 제어할 수 있는 원 칩(one chip) 시스템 IC를 개발하였다. 이를 위하여 화재에 직접적으로 영향을 미치는 아크(arc) 검출회로와 감전을 방지하기 위한 누전검출회로를 설계하였다. 시뮬레이션과 표준트랜지스터를 이용한 bread boarding 평가에 의해 블록별로 설계된 회로를 검증하였다. 평가결과로부터 34 V 2 Metal $1.5{\mu}m$바이폴라 트랜지스터 공정을 이용하여 시스템 IC를 제작하였다. 제작된 시스템 IC와 IC응용회로를 PCB보드에 실장하여 화재방지 시스템보드의 전기적 성능을 평가하였으며, 아크와 GF(ground fault) 신호에 잘 동작함을 확인하였다.

7.2kV급 로타리아크식 $SF_6$가스 전자접촉기 소호부 개발연구 (Development of Model Interrupter of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Principle)

  • 장기찬;신영준;박경엽;정진교;김진기;김귀식;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.30-32
    • /
    • 1995
  • The model interrupters of $SF_6$ gas electromagnetic contactor whose ratings are the voltage of 7.2kV and the short circuit current of 4.0kA have been designed and manufactured on the basis of theoretical and computational analysis for its development. The eddy current analysis, the magnetic field analysis and the calculation of the rotational force on arcs have been conducted using FLUX2D package. The short circuit current interrupting tests have been conducted to the model interrupters using the simplified capacitive synthetic test circuit in KERI. The results show that the model interrupters have a sufficient interrupting capability and the new design concept is proper for a good interrupting performance.

  • PDF

초고압 가스차단부의 냉가스 유동해석 (An Analysis of Cold Gas Flow-Field for UHV Class Interrupters)

  • 송기동;박경엽;송원표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.387-394
    • /
    • 2000
  • This paper presents a method of cold gas flow-field analysis within puffer type GCB(Gas Circuit Breaker). Using this method, the entire interruption process including opening operation of GCB can be simulated successfully. In particular, the distortion problem of the grid due to the movement of moving parts can be dealt with by the fixed grid technique. The gas parameters such as temperature, pressure, density, velocity through the entire interruption process can be calculated and visualized. It was confirmed that the time variation of pressure which was calculated from the application of the method to a model GCB agreed with the experimental one. Therefore it is possible to evaluate the small current interruption capability analytically and to design the interrupter which has excellent interruption capability using the proposed method. It is expected that the proposed method can reduce the time and cost for development of GCB very much. It also will be possible to develop the hot-gas flow-field analysis program by combining the cold-gas flow field program with the arc model and to evaluate the large current interruption capability.

  • PDF

스위치드 릴럭턴스 전동기 (SRM) 회전자 위치 검출 및 초기 위치확보 연구 (A Study on Rotor Position Detection and Securing Initial Position for Switched Reluctance Motor (SRM))

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권3호
    • /
    • pp.141-146
    • /
    • 2020
  • 브러시리스 DC 전동기(BLDC)는 스위치의 on/off 각이 최적의 고정자와 회전자의 정렬상태에 의해 결정되는 반면에, 스위치드 릴럭턴스 전동기 (SRM)은 스위치의 on/off 각이 많은 파라미터의 복잡한 함수로 나타나고 따라서 최적의 운전을 하기 위해서는 스위칭 각이 가변적으로 된다. 따라서 스위치드 릴럭턴스 전동기 (SRM)을 최적으로 운전하기 위해서 고해상도의 위치 센서와 복잡한 부가 회로 등을 이용하여 회전자 위치를 검출할 수 있다. 본 논문에서는 스위치드 릴럭턴스 전동기 (SRM)를 구동할 수 있는 여러 가지 방법 중 엔코더, 홀센서, 옵토-인터럽터 (opto interrupter) 등 다양한 센서들을 활용하여 회전자 위치 검출 및 관련 위치 검출 회로적용, 검출된 회전자의 초기위치 확보에 관한 연구를 하였다.

마이크로프로세서를 이용한 아크결함 차단기 설계 (Arc Fault Circuit Interrupter Design using Microprocessor)

  • 윤광호;반기종;이효직;박병석;남문현
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.12-18
    • /
    • 2007
  • 본 연구에서 설계한 AFCI는 Arc 고장 차단기로서 종속된 전기 배선상의 노화, 절연 및 배선 파괴, 연결 고장, 절연과 배선에 과도한 기계적 손상으로 인한 아크고장을 검출하여 차단하는 기능을 가지고 있으며 기존 차단기가 가지고 있던 과전류에 의한 바이메탈의 만곡 특성에 의한 동작으로 차단하는 방식은 차단에 긴 시간이 걸리나 설계한 AFCI는 전자방식으로서 과부하, 과전류에 의한 기계적 , 전기적인 스트레스를 검출하여 차단하는 기능을 가진 제품으로 차단시간이 100% 이상 단축되어 전기 화재의 발생률을 낮추도록 하였다.

직렬아크 파형 분석 및 검출 알고리즘 (Series Arc Wave Analysis and Detection Algorithm)

  • 권완성;최수경;방선배;김종민;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.240-242
    • /
    • 2009
  • 현재 미국에서는 전기화재를 예방하기 위한 AFCI(Arc Fault Circuit Interrupter) 설치가 법으로 제정되어 보급되고 있으며 이에 대한 기준인 UL1699가 제정되어 있다. 본 논문에서는 UL1699의 규정에 기반한 직렬아크발생장치를 통하여 여러 가정용 부하에서 발생시킨 아크의 전류파형들을 주파수영역과 이산 웨이블렛을 이용하여 분석해보고 그에 따른 검출 알고리즘을 제안하고자 한다.

  • PDF

아크차단기의 필요성에 관한 연구 (Research on Necessity of Arc Fault Circuit Interrupter)

  • 박치현;배석명;임용배;김기현;최명일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.450-453
    • /
    • 2007
  • 전력사용이 증가함에 따라 전기설비에 의한 전기화재 수가 늘어나고 있다. 통계에 따르면 전기화재가 화재원인 중 가장 많은 비중을 차지하고 있음을 알 수 있다. 그럼에도 불구하고 전기화재를 정확히 찾아낼 수 있는 조사기법이 개발되지 않고 있는 실정이다. 이 논문은 전기화재 원인과 아크차단기의 특성에 관하여 분석한다. 아크에 의한 위험을 수학적 분석을 이용한 전력계산을 통하여 분석하고 단락회로에 의한 위험성과 비교한다. 또한 아크차단기와 기존의 누전차단기와 비교를 통하여 아크차단기의 필요성을 제기한다.

  • PDF

AFCI용 ASIC의 온도보상에 관한 연구 (A Study on the Temperature Compensation of ASIC for AFCI)

  • 양승국;이주
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.109-113
    • /
    • 2013
  • In order to avoid the electrical fire, AFCI(Arc Fault Cirruit Interrupter) has been obligated to be adopted in the United States of America since 2002. AFCI using line resistor of neutral trace needs to compensate the variation of the line resistance by temperature variation. In this paper, the ASIC including the temperature compensation circuit is implemented. The proposed implementation is verified by showing the effectiveness of an electric and a temperature characteristics for Arc signals by simulation results.