• 제목/요약/키워드: Circuit Resistance

Search Result 1,139, Processing Time 0.029 seconds

Study of Examples for Air Bag Non-deployment Including Rear Collision and Failure Phenomenon by Damage of Control Parts in Vehicle Air Bag (자동차 에어백의 제어부품 불량에 의한 고장현상 및 후방 추돌에 관련된 에어백 미전개에 대한 사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Moon, Hak Hook
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.102-106
    • /
    • 2012
  • The purpose of this paper is to study the failure cases in relation to system of Air Bag in vehicle happened in the field. In the first example, it was separated the soldering parts connected the wire pin between air bag module and clock spring of air bag. Whenever the pin shake by the car's vibration, the driver verified the malfunction phenomenon appeared air bag warning lamp on instrument panel in front of driver's seat. in car inside room. The second example, it verified the warning lamp lighting phenomenon of air bag by produced the circuit plate non-contacting of single an element in air bag electronic control unit. The third example, it verified the light of air bag warning indicator lamp by separated with soldering parts connecting inner pin and resistance terminal of seat belt pretensioner using passenger seat. The fourth example, when the passenger car crash a back of truck, the former bumper get jammed under the latter as the roof height of car low less than that. Therefore, the impact of Car's collision verified that don't transfer with body frame of vehicle because of no attachment impact sensor in it.

Studies on the Ventilatory Functions of the Korean Children and Adolescents, with Special References to Prediction Formulas (한국 어린이 및 청소년의 폐환기능에 관한 연구 - 특히 표준치 예측 수식에 관하여 -)

  • Park, Hae-Kun;Kim, Kwang-Jin
    • The Korean Journal of Physiology
    • /
    • v.9 no.2
    • /
    • pp.7-15
    • /
    • 1975
  • The maximum breathing capacity (MBC) and the maximum mid-expiratory flow rate (MMF) are widely used in evaluation of the ventilatory function, among various parameters of pulmonary function. The MBC volume is the amount of gas which can be exchanged per unit time during maximal voluntary hyperventilation. Performance of this test, unlike that of single breath maneuvers, is affected by the integrity of the respiratory bellows as a whole including such factors are respiratory muscle blood supply, fatigue, and progressive trapping of air. Because of this, the MBC and its relation to ventilatory requirement correlates more closely with subjective dyspnea than does any other test. The MMF is the average flow rate during expiration of the middle 50% of the vital capacity. The MMF is a measurement of a fast vital capacity related to the time required for the maneuver and the MMF relates much better to other dynamic tests of ventilatory function and to dyspnea than total vital capacity, because the MMF reflects the effective volume, or gas per unit of time. Therefore, it is important to have a prediction formula with one can compute the normal value for the subject and the compare with the measured value. However, the formulas for prediction of both MBC and MMF of the Korean children and adolescents are not yet available in the present. Hence, present investigation was attempt to derive the formulas for prediction of both MBC and MMF of the Korean children and adolescents. MBC and MMF were measured in 1,037 healthy Korean children and adolescents (1,035 male and 1,002 female) whose ages ranged from 8 to 18 years. A spirometer (9L, Collins) was used for the measurement of MBC and MMF. Both MBC and MMF were measured 3times in a standing position and the highest values were used. For measurement, the $CO_2$ absorber and sadd valve were removed from the spirometer in order to reduce the resistance in the breathing circuit and the subject was asked to breathe as fast and deeply as possible for 12 seconds in MBC and to exhale completely as fast as possible after maximum inspiration for MMF. During the measurement, investigator stood by the subject to give a constant encouragement. All the measured values were subsequently converted to values at BTPS. The formulas for MBC and MMF were derived by a manner similar to those for Baldwin et al (1949) and Im (1965) as function of age and BSA or age and height. The prediction formulas for MBC (L/min, BTPS) and MMF (L/min, BTPS) of the Korean children and adolescents as derived in this investigation are as follows: For male, MBC=[41.70+{$2.69{\times}Age(years)$}]${\times}BSA$ $(m^{2})$ MBC=[0.083+{$0.045{\times}Age(years)$}]${\times}Ht$ (cm) For female, MBC=[45.53+{$1.55{\times}Age(years)$}]${\times}BSA$ $(m^2)$ MBC=[0.189+{$0.029{\times}Age(years)$}]${\times}Ht$ (cm) For male, MMF= [0.544+{$0.066{\times}Age(years)$}]${\times}Ht$ (cm) For female, MMF=[0.416+{$0.064{\times}Age(years)$}]${\times}Ht$ (cm)

  • PDF

Input Balun Design Method for CMOS Differential LNA (차동 저 잡음 증폭기의 입력 발룬 설계 최적화 기법)

  • Yoon, Jae-Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • In this paper, the analysis of baluns that are inevitably required to design a differential low noise amplifier, The balun converts a single signal input from the antenna into a differential signal, which serves as an input to the differential amplifier. In addition, it protects the circuit from ESD(Electrostatic Discharge) coming through the antenna and helps with input matching. However, in the case of a passive balun used in general, since the AC signal is transmitted through electromagnetic coupling formed between two metal lines, it not only has loss without gain but also has the greatest influence on the total noise figure of the receiving end. Therefore, the design of a balun in a low-noise amplifier is very important, and it is important to design a balun in consideration of line width, line spacing, winding, radius, and layout symmetry that are necessary. In this paper, the factors to be considered for improving the quality factor of balun are summarized, and the tendency of variation of resistance, inductance, and capacitance of the balun according to design element change is analyzed. Based on the analysis results, it is proved that the design of input balun allows the design of low noise, high gain differential amplifier with gain of 24 dB and noise figure of 2.51 dB.

Vibration Test for PCB/Connector Assembly (인쇄회로기판 진동이 커넥터에 미치는 영향)

  • 허남일;김성철;송규섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.160-164
    • /
    • 1995
  • 정보통신 시스템의 고속/고밀도화 요구에 따라 개발되고 있는 ATM(Asynchronous Transfer Mode) 교환기 시스템은 팬을 이용한 강제대류냉각 방식의 채택과 시스템이 설치되는 장소에 따른 여러 환경조건에 의한 진동 문제가 발생될 수 있다. 시스템의 진동으로 인한 피해중 커넥터 접촉부에서 전기적 특성의 변화는 고속으로 전송되는 신호의 왜곡을 유발시킬 수 있어 시스템 개발시 이에 대한 충분한 연구 및 시험이 요구되고 있다. 진동환경에서 커넥터 접촉부는 접촉면의 상대운동으로 인한 접촉저항의 증가와 순간적인 신호전달 중단을 가져오게 되며, 특히 PCB/Connector Assembly에서 커넥터 접촉부는 PCB(Printed Circuit Board)의 장착 조건 및 동적 거동에 따라 전기적 특성이 변할 수 있다. 시스템에서 커넥터의 동적 거동을 이해하기 위해서는 PCB를 포함하는 시스템내 여러 요소의 동적 특성 이해와 복잡한 해석과정이 요구되며, 시스템 개발자는 진동 환경에서 이것의 시험 결과에 따라 커넥터의 사용을 결정해야 할 것이다. 커넥터의 전기적 특성 시험법은 IEC, EIA드 여러 국제 규격에 제시되어 있으며, 본 연구의 대상이 된 ATM교환기 시스템에서 PCB/Connector Assembly의 진동환경에서 접촉저항 측정과 관련된 접촉저항 임계치 및 측정법은 IEEE 규격 및 Bellcore 규격에 규정되어 있다. Bellcore에는 주어진 진동시험주기 전후에 IEC 규격의 LLCR(Low Level Contact Resistance) 측정회로를 이용한 측정법이 규정되어 있고, 냉각팬 및 주위 환경진동이 가해지는 동안의 영향에 대한 시험법은 규정되어 있지 않다. 본 연구에서는 한국통신의 전자장비 운용환경시험 조건의 진동에서 ATM 교환기 시스템에 사용되는 PCB/Connector Assembly 커넥터 접촉부의 접촉저항 변화와 PCB 진동에 의한 영향을 시험하였다.proach)등이 제시되었고 평면파 영역에 한하여 해서되어져 왔다. 본 논문에서는 분할 접근 방법(Segmentation Approach)을 이용하여 다공 요소로 이루어진 소음기를 해석하는데 적용하였다.로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity v

  • PDF

Electrical Characteristics of Copper Circuit using Inkjet Printing (잉크젯 프린팅 방식으로 형성된 구리 배선의 전기적 특성 평가)

  • Kim, Kwang-Seok;Koo, Ja-Myeong;Joung, Jae-Woo;Kim, Byung-Sung;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.43-49
    • /
    • 2010
  • Direct printing technology is an attractive metallization method, which has become immerging as "Green technology" to the conventional photolithography, on account of low cost, simple process and environment-friendliness. In order to commercialize the printed electronics in industry, it is essential to evaluate the electrical properties of conductive circuits using direct printing technology. In this contribution, we focused on the electrical characteristics of inkjet-printed circuits. A Cu nanoink was inkjet-printed onto a Bisaleimide triazine(BT) substrate with parallel transmission line(PTL) and coplanar waveguide(CPW) type, then was sintered at $250^{\circ}C$ for 30 min. We calculated the resistivity of printed circuits through direct current resistance by the measurement of I-V curve: the resistivity was approximately 0.558 ${\mu}{\Omega}{\cdot}cm$ which is about 3.3 times that of bulk Cu. Cascade's probe system in the frequency range from 0 to 30 GHz were employed to measure the Scattering parameter(S-parameter) with or without a gap between the substrate and the probe station chuck. The result of measured S-parameter showed that all printed circuits had over 5 dB of return loss in the entire frequency range. In the curve of insertion loss, $S_{21}$, showed that the PTL type circuits had better transmission of radio frequency (RF) than CPW type.

A Design of High Efficiency Distributed Amplifier Using Optimum Transmission Line (최적 전송 선로를 이용한 고효율 분산형 증폭기의 설계)

  • Choi, Heung-Jae;Ryu, Nam-Sik;Jeong, Young-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • In this paper, we propose a numerical analysis on reversed current of distributed amplifier based on transmission line theory and proposed a theory to obtain optimum transmission line length to minimize the reversed currents by cancelling those components. The reversed current is analyzed as being simply absorbed into the terminal resistance in the conventional analysis. In the proposed analysis, however, they are designed to be cancelled by each other with opposite phase by the optimal length of the transmission lint Circuit simulation and implementation using pHEMT transistor were performed to validate the proposed theory with the cutoff frequency of 3.6 GHz. From the measurement, maximum gain of 14.5dB and minimum gain of 12.3dB were achieved In the operation band. Moreover, measured efficiency of the proposed distributed amplifier is 25.6% at 3 GHz, which is 7.6%, higher than the conventional distributed amplifier. Measured output power Is about 10.9dBm, achieving 1.7dB higher output power than the conventional one. Those improvement is thought to be based on the cancellation of refersed current.

A Study on the Optimal Design of Soft X-ray Ionizer using the Monte Carlo N-Particle Extended Code (Monte Carlo N-Particle Extended 코드를 이용한 연X선 정전기제거장치의 최적설계에 관한 연구)

  • Jeong, Phil hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.34-37
    • /
    • 2017
  • In recent emerging industry, Display field becomes bigger and bigger, and also semiconductor technology becomes high density integration. In Flat Panel Display, there is an issue that electrostatic phenomenon results in fine dust adsorption as electrostatic capacity increases due to bigger size. Destruction of high integrated circuit and pattern deterioration occur in semiconductor and this causes the problem of weakening of thermal resistance. In order to solve this sort of electrostatic failure in this process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. X-ray Generating efficiency has an effect on soft X-ray Ionizer affects neutralizing performance. There exist variable factors such as type of anode, thickness, tube voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was measured according to target material thickness using MCNPX under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W), Gold(Au), Silver(Ag). At the result, Gold(Au) shows optimum efficiency. In Tube voltage 5 keV, optimal target thickness is $0.05{\mu}m$ and Largest energy of Light flux appears $2.22{\times}10^8$ x-ray flux. In Tube voltage 10 keV, optimal target Thickness is $0.18{\mu}m$ and Largest energy of Light flux appears $1.97{\times}10^9$ x-ray flux. In Tube voltage 15 keV, optimal target Thickness is $0.29{\mu}m$ and Largest energy of Light flux appears $4.59{\times}10^9$ x-ray flux.

A Study on the Cobalt Electrodeposition of High Aspect Ratio Through-Silicon-Via (TSV) with Single Additive (단일 첨가제를 이용한 고종횡비 TSV의 코발트 전해증착에 관한 연구)

  • Kim, Yu-Jeong;Lee, Jin-Hyeon;Park, Gi-Mun;Yu, Bong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.140-140
    • /
    • 2018
  • The 3D interconnect technologies have been appeared, as the density of Integrated Circuit (IC) devices increases. Through Silicon Via (TSV) process is an important technology in the 3D interconnect technologies. And the process is used to form a vertically electrical connection through silicon dies. This TSV process has some advantages that short length of interconnection, high interconnection density, low electrical resistance, and low power consumption. Because of these advantages, TSVs could improve the device performance higher. The fabrication process of TSV has several steps such as TSV etching, insulator deposition, seed layer deposition, metallization, planarization, and assembly. Among them, TSV metallization (i.e. TSV filling) was core process in the fabrication process of TSV because TSV metallization determines the performance and reliability of the TSV interconnect. TSVs were commonly filled with metals by using the simple electrochemical deposition method. However, since the aspect ratio of TSVs was become a higher, it was easy to occur voids and copper filling of TSVs became more difficult. Using some additives like an accelerator, suppressor and leveler for the void-free filling of TSVs, deposition rate of bottom could be fast whereas deposition of side walls could be inhibited. The suppressor was adsorbed surface of via easily because of its higher molecular weight than the accelerator. However, for high aspect ratio TSV fillers, the growth of the top of via can be accelerated because the suppressor is replaced by an accelerator. The substitution of the accelerator and the suppressor caused the side wall growth and defect generation. The suppressor was used as Single additive electrodeposition of TSV to overcome the constraints. At the electrochemical deposition of high aspect ratio of TSVs, the suppressor as single additive could effectively suppress the growth of the top surface and the void-free bottom-up filling became possible. Generally, copper was used to fill TSVs since its low resistivity could reduce the RC delay of the interconnection. However, because of the large Coefficients of Thermal Expansion (CTE) mismatch between silicon and copper, stress was induced to the silicon around the TSVs at the annealing process. The Keep Out Zone (KOZ), the stressed area in the silicon, could affect carrier mobility and could cause degradation of the device performance. Cobalt can be used as an alternative material because the CTE of cobalt was lower than that of copper. Therefore, using cobalt could reduce KOZ and improve device performance. In this study, high-aspect ratio TSVs were filled with cobalt using the electrochemical deposition. And the filling performance was enhanced by using the suppressor as single additive. Electrochemical analysis explains the effect of suppressor in the cobalt filling bath and the effect of filling behavior at condition such as current type was investigated.

  • PDF

A Study on the Disaster Prevention Technology of the Switchboard with Upper and Lower Bending Type Seismic Pads (상하굴절형 내진패드를 설치한 수배전반 방재기술에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;Lee, Jaewon;Kim, Taejin;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2017
  • The purpose of this study is to investigate the effect of vertical and horizontal refraction on the lower part of the power supply and control system of various facilities and machinery that use electricity, so that the power distribution system, which is an important electric facility installed in buildings and public facilities, Type earthquake resistant pads to protect the substructure and prevent short-circuiting on the upper part of the system. The GR-63-CORE (Scale 8.3 class) It is earthquake disaster prevention and disaster prevention technology that satisfies seismic performance. As a research result, it is possible to protect the electricity and communication infrastructure, which can contribute to shortening the time for recovering the electric facilities to the normal state in case of an earthquake, and preventing the fire caused by the destruction of the electricity supply facility in case of an earthquake. As a result, it is possible to minimize the spread of fire that occurs when a large-scale earthquake occurs and to minimize the damage of people and damage to property, and it can contribute to the securing of electric infrastructure that enables citizens to quickly recover to daily life even after suffering a major earthquake. In addition, the technology can be applied to ensure the seismic resistance of the equipment in the communication and computer room, and it can be applied to various fields where the facility function can be stopped due to the shaking of the earthquake base.

A Scalable Bias-dependent P-HEMT Noise Model with Single Drain Current Noise Source (드레인 전류 잡음원만을 고려한 스케일링이 가능한 바이어스 의존 P-HEMT 잡음모델)

  • 윤경식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1579-1587
    • /
    • 1999
  • Bias-dependent noise models of $0.2\mu\textrm{m}$ gate length P-HEMT's which are scalable with gate width are proposed. To predict S-parameters of the P-HEMT's the intrinsic parameters except for $\tau$ subtracted the offsets introduced in this paper are normalized to the gate width and then scaled. The small-signal model parameters are expressed as fitting functions of the drain current to $\textrm{I}_{dss}$ ratio and gate width. In addition, to estimate accurately noise parameters the noise temperature $\textrm{T}_{g}$ of the intrinsic resistance, the equivalent noise conductance $\textrm{G}_{ni}$ of the gate current noise source, and the equivalent noise conductance $\textrm{G}_{no}$ of the drain current noise source are adopted as the noise model parameters. The extracted values of $\textrm{T}_{g}$ are nearly independent of drain current and gate width and their average is around the ambient temperature. The extracted values of $\textrm{G}_{ni}$ are small enough to be neglected to the circuit characteristics. From the comparison of the noise model with only $\textrm{G}_{no}$ and that having $\textrm{T}_{g}$, $\textrm{G}_{ni}$ and $\textrm{G}_{no}$ to the measured data it is fund that even the former model is in good agreement with the measured noise parameters. Thus, from a practical point of view the noise model having only the drain current noise source is confirmed as a scalable bias-dependent model.

  • PDF