• Title/Summary/Keyword: Circuit Drive Method

Search Result 243, Processing Time 0.032 seconds

Drive Circuit of 4-Level Inverter for 42V Power System

  • Park, Yong-Won;Sul, Seung-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.112-118
    • /
    • 2001
  • In the near future, the voltage of power system for passenger vehicle will be changed to 42V from existing 14V./ Because of increasing power and voltage ratings used in the vehicle the motor drive system has high switching dv/dt and it generates electromagnetic interference (EMI) To solve these problems multi-level inverter system may be used The feature of multi-level inverter is the output voltage to be synthesized from several levels of voltage Because of this feature high switching dv/dt and EMI can be reduced in the multi-level inverter system But as the number of level is increased manufacturing cost is getting expensive and system size is getting large. Because of these disadvantages the application of multi-level inverter has been restricted only to high power drives. The method to reduce manufacturing cost and system size is to integrate circuit of multi-level inverter into a few chips But isolated power supply and signal isolation circuit using transformer or opto-coupler for drive circuit are obstacles to implement the integrated circuit (IC) In this paper a drive circuit of 4-level inverter suitable for integration to hybrid or one chip is proposed In the proposed drive circuit DC link voltage is used directly as the power source of each gate drive circuit NPN transistors and PNP transistors are used to isolate to transfer the control signals. So the proposed drive circuit needs no transformers and opto-couplers for electrical isolation of drive circuit and is constructed only using components to be implemented on a silicon wafer With th e proposed drive circuit 4- level inverter system will be possible to be implemented through integrated circuit technology Using the proposed drive circuit 4- level inverter system is constructed and the validity and characteristics of the proposed drive circuit are proved through the experiments.

A Gate Drive Circuit for Low Switching Losses and Snubber Energy Recovery

  • Shimizu, Toshihisa;Wada, Keiji
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.259-266
    • /
    • 2009
  • In order to increase the power density of power converters, reduction of the switching losses at high-frequency switching conditions is one of the most important issues. This paper presents a new gate drive circuit that enables the reduction of switching losses in both the Power MOSFET and the IGBT. A distinctive feature of this method is that both the turn-on loss and the turn-off loss are decreased simultaneously without using a conventional ZVS circuit, such as the quasi-resonant adjunctive circuit. Experimental results of the switching loss of both the Power MOSFET and the IGBT are shown. In addition, an energy recovery circuit suitable for use in IGBTs that can be realized by modifying the proposed gate drive circuit is also proposed. The effectiveness of both the proposed circuits was confirmed experimentally by the buck-chopper circuit.

Circuit Design of Drive Control for Winch Drum (윈치드럼 구동제어 회로설계)

  • 조상훈;양승윤;박래석
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.45-58
    • /
    • 2002
  • In this paper, we designed the circuit of drive control for towing winch. It is composed of reference voltage circuit for driving voltage reference, low pass filter circuit for noise reduction, dead zone circuit for initial transient input, and driving circuit for drum direction/velocity control. Also it is realized a drive control circuit for towing winch drum in accordance with PWM(pulse width modulation) method to suit it's purpose of a large capacity driving system. The performance of the designed circuit is analyzed by experiments and the appliablity for driving the towing winch drum satisfactorily is evaluated through a various testing.

Power Factor Correction Circuit For Inverter Air-Conditioner Using A Parallel Drive Method (병렬구동 방식을 이용한 인버터 에어컨용 역률제어회로)

  • 정용채;정윤철;권경안
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.9-12
    • /
    • 1998
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[ph] compressor motor may obtain the cost down and the improved performance. The adequate design procedures are presented to reduce the material costs by eliminating the power factor improving LC filter and derating output capacitor and inverter switches. Using the determined components, the prototype circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

A Study on the Drive Circuit and Control Method for Single-Salient Type SRM Motor with Maximium Torque Region (토오크 사용영역의 극대화를 위한 Single-Salient Type SRM의 구동회로 및 제어방식에 관한 연구)

  • Park, Sung-Jun;Byun, Young-Bok;Kwon, Soon-Jae;Kim, Chul-U
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.354-356
    • /
    • 1994
  • This paper describes a drive circuit and control method for SRM motor with maximum torque region. The proposed switching method is tested by experiment on single salient type SRM motor. As a result, The SRM drive with the proposed scheme is effective in increasing of torque region.

  • PDF

An Improvement of Multistep Response of PM Step Motor Using Dual Voltage Power Supply (Dual 전압공급에 의한 PM 스텝모우터의 다 스텝 응답개선)

  • Kim, Do-Hyun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.3
    • /
    • pp.269-275
    • /
    • 1988
  • In this paper, a high efficiency motor drive system which improves the multi-step response of PM step motors by reducing the transition time of the motor drive current, is studied by designing a dual-voltage drive circuit. The designed drive circuit eventually prevents the motor from decreasing drive torque while the stepping rate is increased. The method of designing a dual-voltage drive circuit with the motor specifications is suggested in order to improve the response of step rate and drive efficiency. Also, despite improving the power efficiency on motor driving, the response characterstics suggested by the motor manufacture's specifications are satisfied without any special deficiency.

  • PDF

A Study on the Drive Circuit Improvement In the Low Impedance Communication (저임피던스 통신 환경에서의 구동회로 개선에 관한 연구)

  • Choi, Tae-Seop;Lim, Seung-Ha
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.1001-1002
    • /
    • 2006
  • As most of the powerline modems use spread spectrum modulation method which has strong immunity against the narrowband fading, or psk modulation method, the amplitude of the signal contains no useful informations. In this paper, we used class D amplifier to implement the drive circuit of the analog front end, and showed that it has great superiority over other existing drive circuits in rapidly impedance changing power line channel.

  • PDF

Single-phase SRM Drive with Torque Ripple Reduction and Power Factor Improvement

  • Lee, D.H.;Ahn, J.W.;Lee, Z.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.57-61
    • /
    • 2006
  • In the single-phase switched reluctance motor (SRM) drive, the required DC source is generally supplied by the circuit consisting of bridge rectifier and large filter capacitor connected with DC line terminal. Due to the large capacity of the capacitor, the charged time of capacitor is very short from the AC source. Lead to the bridge rectifiers draws pulsating current from the AC source side, which results in reduction of power factor and low system efficiency. Therefore a novel single-phase SRM drive system is presented in this paper, which includes drive circuit realizing reduction of torque ripple and improvement of power factor with a novel switching topology. The proposed drive circuit consists of one switching part and diode, which can separate the output of AC/DC rectifier from the large capacitor and supply power to SRM alternately, in order to realize the torque ripple reduction and power factor improvement through the switching scheme. In addition, the validity of the proposed method is tested by some simulations and experiments.

  • PDF

Development of Drive for BLDC Motor Using Resolver (레졸버를 이용한 BLDC 모터의 드라이브 개발)

  • Lee, G.Y.;Lee, C.H.;Kim, S.B.;Kwon, S.J.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.64-69
    • /
    • 1999
  • The paper shows a result for development of BLDC motor drive by using a resolver as position detection sensor. The developed drive use a method detecting rotor position based on HSI interrupt function of microprocessor without a specialized counting circuit. The algorithm generating three-phase PWM wave to change switching voltage and current is realized based on single chip microprocessor. The PWM generating part and position counting circuit are realized by software technique without usage of conventional analogue circuit or object-oriented chips. So the drive system become compact. The effectiveness of the developed drive is verified by experimented results of speed response for step reference input.

  • PDF

Performance Evaluation of the Field-Oriented Control of Star-Connected 3-Phase Induction Motor Drives under Stator Winding Open-Circuit Faults

  • Jannati, Mohammad;Idris, Nik Rumzi Nik;Aziz, Mohd Junaidi Abdul
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.982-993
    • /
    • 2016
  • A method for the fault-tolerant vector control of star-connected 3-phase Induction Motor (IM) drive systems based on Field-Oriented Control (FOC) is proposed in this paper. This method enables the control of a 3-phase IM in the presence of an open-phase failure in one of its phases without the need for control structure changes to the conventional FOC algorithm. The proposed drive system significantly reduces the speed and torque pulsations caused by an open-phase fault in the stator windings. The performance of the proposed method was verified using MATLAB (M-File) simulation as well experimental tests on a 1.5kW 3-phase IM drive system. This paper experimentally compares the operation of the proposed fault-tolerant vector controller and a conventional vector controller during open-phase fault.