• Title/Summary/Keyword: Chromium-hexavalent

Search Result 167, Processing Time 0.027 seconds

A Study of Working Environments and Workers Exposed to Chromium (크롬 취급 사업장의 작업환경 및 근로자 폭로 실태에 관한 연구)

  • Yu, Byung-Chul;Son, Byung-Chul;Jun, Jin-Ho;Han, Yong-Soo;Son, Hye-Sook;Lee, Chae-Eun;Jeong, Woon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.517-530
    • /
    • 1994
  • For the purpose of providing the basic data for health management of workers who are exposed to chromium and for improving the quality of working environment, the authors evaluated blood and urinary level of chromium, the occupational history. AST, ALT, Hb, Hct, nasal specular examinaton on 287 workers who have been dealed chromium compounds in 56 manufacturing Industries of five types, that is, 38 metal plating services(plating),4 manufacture of other fabricated metal products (fabricated metal product), 5 manufacturing of dyestuff(dyestuff), 6 dressing and dyeing of leather(leather), 3 others(manufacture of pottery and ceramic househod wares, motor vehicles, electronic valves and tubes and other electronic components) and also measured the level of chromium in air from February to October 1993. The results were as follows ; 1. The utilized type of chromium compounds was the hexavalent state in plating fabricated metal product dyestuff, leather and the trivalent state in .other, and atmosperic chromium concentration as geometric mean was $0.0138mg/m^3(0.001{\sim}0.068mg/m^3)$ in plating, $0.0115mg/m^3(0.006{\sim}0.015mg/m^3)$ in fabricated matal product, $0.068mg/m^3(0.002{\sim}0.019mg/m^3)$ in dyestuff, $0.0083mg/m^3(0.002{\sim}0.028mg/m^3)$ in leather $0.0039mg/m^3(0.003{\sim}0.005mg/m^3)$ in other by the type of industry and it exceeded TLV-TWA ($0.05mg/m^3$) in five (13.6%) of plating services. 2. The geometric mean of chromium in blood was $1.54{\mu}g/dl(0.10{\sim}3.62{\mu}g/dl)$ in Plantng, $0.94{\mu}g/dl(0.27{\sim}2.82{\mu}g/dl)$ in fabricated metal product, $0.51{\mu}g/dl(0.10{\sim}3.25{\mu}g/dl)$ in dyestuff, $0.87{\mu}g/dl(0.15{\sim}8.00{\mu}g/dl)$ in leather, $0.55{\mu}g/dl(0.20{\sim}2.28{\mu}g/dl)$ in other by the type of industry(p<0.001). 3. The geometric mean of chromium in urine was $14.47{\mu}g/l(6.90{\sim}28.00{\mu}g/l)$ in planting, $4.63{\mu}g/l(0.24{\sim}43.00{\mu}g/l)$ in fabricated metal product, $5.93{\mu}g/l(1.00{\sim}33.00{\mu}g/l)$ in dyestuff, $11.09{\mu}g/l(0.80{\sim}48.00{\mu}g/l)$ in leather, $12.41{\mu}g/l(10.10{\sim}41.00{\mu}g/l)$ in other by the type of industry(p<0.001). 4. As the result of nasal specular examination, twenty four cases (8.4%) of nasal septal perforation among 287 total subjects was observed, and there were 17 (9.7%) cases in plating, 4 csaes (14.3%) in dressing and dyeing of leather. In the comparison of chromium concentration in blood and urine between the perforated group and non-perforated group, the perforated group showed a significantly higher value as $1.883{\pm}3.055{\mu}g/dl\;and\;0.793{\pm}0.815{\mu}g/dl$(P<0.001), $21.31{\pm}34.610{\mu}g/L\;and\;9.304{\pm}11.079{\mu}g/L$ (P<0.001). 5. The mean concentration of chromium in blood, urine and the mean level of AST, ALT, Hb and Hct in exposure group were higher than those of control group(p<0.001).

  • PDF

Simultaneous Determination of Chromium (III) and Chromium(VI) by High Performance Liquid Chromatography(HPLC) (고성능 액체크로마토그래피(HPLC)를 이용한 3가, 6가 크롬의 동시정량에 관한 연구)

  • Roh, Jae Hoon;Kim, Chi Nyon;Kim, Choon Sung;Kim, Kyoo Sang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.189-197
    • /
    • 1994
  • Analytic methods for Cr(VI) level in industrial hygienic field were suggested by the National Institute for Occupational Safety and Health(NIOSH method 7600, 7604). There were growing needs for measurement of Cr(III) and Cr(VI) levels simultaneously. Two analytical methods were suggested to determine Cr(III) and Cr(VI) levels simultaneously. The one is method by using reversed phase high peformance liquid chromatography(HPLC) and the other is by using ion exchange HPLC. The purpose of this work was to evaluate the usefulness of these two analytic methods. For the difference of ionic charges of Cr(III)-ethylendiamine tetraacetic acid(EDTA) chelate and $CrO_4{^-2}$, we could detect them simultaneously by ion exchange HPLC. Also, we attempted to determine the levels of Cr(III) and Cr(VI) chelated with sodium diethyldithiocarbamate(NaDDTC) by using reversed phase HPLC. The confirmation of Cr(III) and Cr(VI) were checked by fraction collector and nameless atomic absorption spectrometer. The optimal conditions for the formation of Cr(III)-EDTA chelate were two hours incubation period with pH 5. Cr(III)-EDTA and Cr(VI) in EDTA solution were successfully separated by anion exchange column using $Na_2CO_3/NaOH$ mixture as mobile phase. Peaks of Cr(III)-EDTA and Cr(VI) in EDTA were identified at 5 minutes and 7 minutes of retention time respectively by the ion exchange HPLC. The formation of Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates were twelve hours incubation period. Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates were separated by reversed phase column using methanol and water mixture as mobile phase. Peaks of Cr(VI)NaDDTC and Cr(III)-NaDDTC chelates were identified at 13 minutes and 26 minutes of retention time respectively by the reversed phase HPLC. Due to reduction of Cr(VI) to Cr(III), it seems to be not suitable for simultaneous determination of Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates by reversed phase HPLS. Simultaneos determination of Cr(III) and Cr(VI) by ion exchange HPLC was more accurate and simple method.

  • PDF

Adsorption Characteristics of Chromium Ion at Low Concentration Using Oxyfluorinated Activated Carbon Fibers (함산소불화 활성탄소섬유를 이용한 저농도 크롬이온의 흡착 특성)

  • Kim, Min-Ji;Jung, Min-Jung;Choi, Suk Soon;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.432-438
    • /
    • 2015
  • In this work, activated carbon fibers (ACFs) were oxyfluorinated and their adsorption ability for the low concentration of hexavalent chromium in an aqueous solution was investigated. The pore structure and surface properties of ACFs were examined by BET and X-ray Photoelectron Spectroscopy (XPS), respectively. Due to the oxyfluorination treatment, the content of (C-O) bond on ACFs surface which influences the adsorption capacity for heavy metal ions increased largely, resulting that $Cr^{6+}$ adsorption equilibrium reached quickly within 10 min. In addition, the maximum removal efficiency at the initial $Cr^{6+}$ concentration of 20 ppm was observed, which is a 100% improvement compared to that of non-treated ACFs. These results suggest that the oxyfluorination of ACFs can be applied as a good surface treatment for the effective adsorption of the low concentration of $Cr^{6+}$.

About Chromium (VI) Extraction from Fertilizers and Soils

  • Sager Manfred
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.657-662
    • /
    • 2005
  • Extractions fro fertilizer and soil samples were performed to yield the operationally defined fractions 'soluble' chromate (extractable with $NH_4NO_3$), 'exchangeable' chromate (extractable with phosphate buffer pH 7.2), and these results were compared with the data obtained by extractions with ammonium sulfate, borate buffer pH 7.2, saturated borax pH 9.6, and polyphosphate (Graham's salt). In order to maintain the pH of extractant solution about constant, the concentration of extractant buffer had to be raised to at least 0.5 M. The results strongly depended on the kind of extractant, and the solid: liquid ratio. For most of the samples investigated, the extraction efficiency increased in the order borate-sulfate-nitrate-phosphate. Whereas the recovery of $K_2CrO_4\;and\;CaCrO_4$ added to the samples of basic slags prior to the extraction was about complete, the recovery of added $PbCrO_4$ was highly variable. In soil extracts, the color reaction was interfered from co-extracted humics, which react with the chromate in weak acid solution during the time period necessary for color reaction (1 hour). However, this problem can be overcome by standard addition and subtraction of the color of the extractant solution. In soil extract of about pH < 7, organic material reduced chromate during the extraction period also, and standard addition of soluble chromate is recommended to prove recovery and the stability of chromate in the samples. In admixtures of soils and basic slags, results for hexavalent chromium were lower than from the mere basic slags. This effect was more pronounced in phosphate than in nitrate extracts. As a proficiency test, samples low in organic carbon from contaminated sites in Hungary were tested. The results from $NH_4NO_3$ extracts satisfactorily matched the results of the Hungarian labs obtained from $CalCl_2$ extractants.

Evaluation of the Corrosion Resistance of Steel Coated with Zinc Using a Cr-free Coating Solution as a Function of Heat Treatment Time (Cr-free 코팅액에 의한 아연도금강판의 건조시간에 따른 내식특성)

  • Seo, Hyun-Soo;Moon, Hee-Joon;Kim, Jong-Soon;Ahn, Seok-Hwan;Moon, Chang-Kwon;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.67-74
    • /
    • 2010
  • Chromate conversion coating is a coating technique used to passivate aluminum, zinc, cadmium, copper, silver, magnesium, tin, and their alloys to slow corrosion. The process uses various toxic chromium compounds, which may include hexavalent chromium. The industry is developing less toxic alternatives in order to comply with substance restriction legislation, such as RoHS. One alternative is to develop a Cr-free coating solution. In this study, eco-friendly, Cr-free solutions (urethane solution S-700, organic/inorganic solution with Si LRO-317) were used. Test specimens were dried in a drying oven at $190^{\circ}C$ for 3, 5, 7, and 9 minutes. Corrosion resistance was evaluated using a salt spray test for 72 hours. The results show that the optimum corrosion resistance was achieved at $190^{\circ}C$ for five minutes for EGI and three or five minutes for HDGI, respectively. The adhesive properties of the two types of coating solutions were superior regardless of drying time.

A study on characteristics of influent and effluent pollutants in public sewage treatment works combined with industrial wastewater and landfill leachate (공공하수처리시설에서 수질오염물질 유입 및 배출 특성 고찰 - 산업폐수 및 매립지 침출수 연계처리 시설을 중심으로 -)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Kyung-Hee;Kim, Eunseok;Kim, Changsoo;Chung, Hyen-Mi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.673-682
    • /
    • 2016
  • In this study, we investigated influent and effluent water pollutants in 53 Public Sewage Treatment Works (PSTWs) where industrial wastewater or landfill leachate is combined four times for two years from 2014 to 2015. Also, we analyzed the characteristics of heavy metals and volatile organic carbons at influent and effluent of these PSTWs caused by sewage treatment combined with industrial wastewater or landfill leachate. As a result, six heavy metals such as barium, copper, iron, manganese, nickel and zinc, and four volatile organic carbons (VOCs) including phenols, di(2-)ethylhexyl phthalate (DEHP), formaldehyde and toluene were observed above detection limits in most of PSTWs. Also, it was revealed that six heavy metals such as hexavalent chromium, mercury, cadmium, chromium, nickel and selenium, and four VOCs including 1,1-dichloroethylene, vinyl chloride, naphthalene, and epichlorohydrin were observed more frequently according to precipitation. As a result of reviewing the monitoring data on "Water Quality Monitoring Networks" in lower watersheds of PSTWs, both heavy metals and VOCs were below detection limits, indicating that the effluent water had little influence on the watershed. Nevertheless for the better management of influent and effluent pollutants in PSTWs, it is necessary to establish the advanced management plans for water pollutants in PSTWs, which include a list of priority substances management, monitoring plans, and guidelines for industrial wastewater and landfill leachate combined in PSTWs.

Kinetic Analysis and Mathematical Modeling of Cr(VI) Removal in a Differential Reactor Packed with Ecklonia Biomass

  • Park, Dong-Hee;Yun, Yeoung-Sang;Lim, Seong-Rin;Park, Jong-Moon
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.11
    • /
    • pp.1720-1727
    • /
    • 2006
  • To set up a kinetic model that can provide a theoretical basis for developing a new mathematical model of the Cr(VI) biosorption column using brown seaweed Ecklonia biomass, a differential reactor system was used in this study. Based on the fact that the removal process followed a redox reaction between Cr(VI) and the biomass, with no dispersion effect in the differential reactor, a new mathematical model was proposed to describe the removal of Cr(VI) from a liquid stream passing through the differential reactor. The reduction model of Cr(VI) by the differential reactor was zero order with respect to influent Cr(IlI) concentration, and first order with respect to both the biomass and influent Cr(VI) concentrations. The developed model described well the dynamics of Cr(VI) in the effluent. In conclusion, the developed model may be used for the design and performance prediction of the biosorption column process for Cr(VI) detoxification.

Reliability Assessment Methods for Electronic Component Removed Environmental Materials - focused on Printed Wiring Board without Pb and Br - (환경물질을 제외한 전자부품의 신뢰성평가 방법 연구 -Pb와 Br을 제거한 PWB를 중심으로-)

  • Lee Jong-Beom;Cho Jai-Rip
    • Journal of Applied Reliability
    • /
    • v.5 no.2
    • /
    • pp.241-259
    • /
    • 2005
  • The environmental problem is a main subject of the 21C and an environment destruction phenomenon by various kinds of environmental materials is reaching serious level. Nations to be classified as the environmental developed country, are born again environmental rich country. And they earn a large income by trade Every kind environmental resource in an international commercial transaction. Especially, the study that a reliability assessment method to prevent to reliability problem to be happened when the solder lead(lead-free solder), non-cd component, non-bromide component(without the polybrominated biphenyls(PBB) and polybrominated diphenyl ethers(PBDE))and hexavalent chromium(Cr VI) clearance component and mercury-free applied to electronic equipment is progressed. As the result of the study for applying of a reliability assessment technique of lead-free solder that recognized the most of urgent problem at the company, combination accelerated life test could taken by adding and appling the part of a humidity acceleration part to Eyring Model which is proposed by R.E.Thomas. The reliability assessment methods study of PWB clean environmental materials is expected to respond to a reliability elevation and environmental material regulation policy spreading all over the world by beginning form Europe.

  • PDF

The Characteristics of Cr-Free Coating Hot Dip Galvanized Sheet Steel

  • Kim, Jong-Gi;Moon, Man-Been;Yun, Jeong-Mo
    • Corrosion Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.24-29
    • /
    • 2011
  • The greatest purpose of chromate treatment is to improve anti-corrosion by stabilizing a metal surface. Because metal surface forms a compound by absorbing oxygen or water in the air by being generally unstable, it is necessary to improve anti-corrosion of the metal by forming the metal surface with a stable film. When considering the economical efficiency and requirements together because the film of the metal surface treated with chromate has good anti-corrosion and the stability also in the air by being compact and strong, Chromate treatment has been used most up to the electronics industry from the auto industry. However, these days, because hexavalent chromium is both a toxic agent to be able to cause cancers and deadly poisonous environmental pollutant, the strong legal controls on its use is being imposed all over the world. Because of this reason, a new anti-corrosion method is being required. Also, by users' various demands, the passivations that have recently been developed require various characteristics such as conductivity, chemical resistance, alkali cleaning resistance as well as anti-corrosion. We could confirm the results such as excellent anti-corrosion compared to chromate, conductivity, chemical resistance and detergent resistance as the result of analysis of various characteristics of the galvannealed sheet steels coated with Cr-Free solution developed in this research.

Cloning of hexavalent chromium reductase gene from E.coli ATCC 33456

  • Lee, Han-Ki;Ahn, Min-Jung;Bae, Woo-Chul;Jeong, Byeong-Chul
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.672-675
    • /
    • 2000
  • E.coli ATCC 33456 has relatively higher activity of Cr(VI) reduction than other microorganism. The purpose of this research is cloning of Cr(V) reductase from E.coli ATCC 33456. Using colony and southern hybridization, we selected two condidates. Among candidates, pNCR9 is higher Cr(VI) reduction activity than E.coli ATCC 33456. Purified Cr(VI) reductase antibody was reacted at estimated 42Kda protein band of candidate's crude extract on 12% SDS-PAGE. This results showed cloned gene's product is very similar to purified Cr(VI) reductase from E.coli ATCC 33456.

  • PDF