• Title/Summary/Keyword: Chromium Acetate

Search Result 18, Processing Time 0.032 seconds

Assessing Heavy Metals for Estrogenicity Using a Combination of In vitro and In vivo Assays (In vitro 및 In vivo Assay를 통한 중금속의 에스트로겐성 평가)

  • Park, Chul;Kim, So-Jung;Shin, Wan-Chul;Kim, Hae-Gyoung;Choe, Suck-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.9
    • /
    • pp.1486-1491
    • /
    • 2004
  • The estrogenicities of six heavy metal compounds, which contaminate frequently in foods, were assayed using a combination of in vitro and in vivo assays. The assays were 1) estrogen receptor dependent transcriptional expression assay, 2) E-screen assay and, 3) the uterotropic assay in mice. The chemicals studied were 17$\beta$ -estradiol, diethylstilbestrol (DES), arsenic oxide, bis(tri-n-butyltin), cadmium chloride, chromium chloride, lead acetate, and mercuric chloride. Using the estrogen receptor dependent transcriptional expression assay, the following estrogenicity ranking was measured: bis(tri-n-butyltin) > cadmium chloride > chromium chloride >> mercuric chloride >lead acetate = arsenic oxide. Using E-screen test, the following estrogenicity ranking was measured: bis(tri-n-butyltin) > cadmium chloride > chromium chloride >> mercuric chloride > lead acetate = arsenic oxide. Results from the uterotropic assay showed that bis(tri-n-butyltin), cadmium chloride, chromium chloride caused an increase in uterine wet weight, while lead acetate, mercuric chloride, and arsenic oxide failed to do so. Bis(tri-n-butyltin), cadmium chloride and chromium chloride showed the highest estrogenicity in three assay systems. Recent studies suggesting that bis(tri-n-butyltin), cadmium chloride have estrogenicities are compatible with the present finding. Furthermore, our study is suggesting that chromium chloride may be estrogenic. The results demonstrate that this three level-assay combination (transcriptional activation, cell proliferation, and an in vivo effect in an estrogen-responsive tissue) could serve as a useful method to assess the estrogenicity of heavy metals.

Acetate-assisted Synthesis of Chromium(III) Terephthalate and Its Gas Adsorption Properties

  • Zhou, Jing-Jing;Liu, Kai-Yu;Kong, Chun-Long;Chen, Liang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1625-1631
    • /
    • 2013
  • We report a facile synthetic approach of high-quality chromium(III) terephthalate [MIL-101(Cr)] by acetate-assisted method in the absence of toxic HF. Results indicate that the morphology and surface area of the MIL-101(Cr) can be tuned by modifying the molar ratio of acetate/$Cr(NO_3)_3$. The Brunauer-Emmett-Teller (BET) surface area of MIL-101(Cr) synthesized at the optimized condition can exceed 3300 $m^2/g$. It is confirmed that acetate could promote the dissolution of di-carboxylic linker and accelerate the nucleation ratio. So the pure and small size of MIL-101(Cr) with clean pores can be obtained. $CO_2$, $CH_4$ and $N_2$ adsorption isotherms of the samples are studied at 298 K and 313 K. Compared with the traditional method, MIL-101(Cr) synthesized by acetate-assisted method possess enhanced $CO_2$ selective adsorption capacity. At 1.0 bar 298 K, it exhibits 47% enhanced $CO_2$ adsorption capacity. This may be attributed to the high surface area together with clean pores of MIL-101(Cr).

Chromium acetate stimulates adipogenesis through regulation of gene expression and phosphorylation of adenosine monophosphate-activated protein kinase in bovine intramuscular or subcutaneous adipocytes

  • Kim, Jongkyoo;Chung, Kiyong;Johnson, Bradley J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.4
    • /
    • pp.651-661
    • /
    • 2020
  • Objective: We hypothesized that Cr source can alter adipogenic-related transcriptional regulations and cell signaling. Therefore, the objective of the study was to evaluate the biological effects of chromium acetate (CrAc) on bovine intramuscular (IM) and subcutaneous (SC) adipose cells. Methods: Bovine preadipocytes isolated from two different adipose tissue depots; IM and SC were used to evaluate the effect of CrAc treatment during differentiation on adipogenic gene expression. Adipocytes were incubated with various doses of CrAc: 0 (differentiation media only, control), 0.1, 1, and 10 μM. Cells were harvested and then analyzed by real-time quantitative polymerase chain reaction in order to measure the quantity of adenosine monophosphate-activated protein kinase-α (AMPK-α), CCAAT enhancer binding protein-β (C/EBPβ), G protein-coupled receptor 41 (GPR41), GPR43, peroxisome proliferator-activated receptor-γ (PPARγ), and stearoyl CoA desaturase (SCD) mRNA relative to ribosomal protein subunit 9 (RPS9). The ratio of phosphorylated-AMPK (pAMPK) to AMPK was determined using a western blot technique in order to determine changing concentration. Results: The high dose (10 μM) of CrAc increased C/EBPβ, in both IM (p = 0.02) and SC (p = 0.02). Expression of PPARγ was upregulated by 10 μM of CrAc in IM but not in SC. Expression of SCD was also increased in both IM and SC with 10 μM of CrAc treatment. Addition of CrAc did not alter gene expression of glucose transporter 4, GPR41, or GPR43 in both IM and SC adipocytes. Addition of CrAc, resulted in a decreased pAMPKα to AMPKα ration (p<0.01) in IM. Conclusion: These data may indicate that Cr source may influence lipid filling in IM adipocytes via inhibitory action of AMPK phosphorylation and upregulating expression of adipogenic genes.

Determination of Chromium (Ⅵ) by Extraction Polarographic Method (추출폴라로그래프법에 의한 Cr (Ⅵ) 의 정량)

  • Park Doo Won;Bae Zun Ung
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.494-499
    • /
    • 1976
  • The extraction-polarographic method applied to the determination of micro amount of chromium (Ⅵ). Chromium(Ⅵ) was extracted into methylisobuthylketone(MIBK) layer containing diethyldithiocarbamate(DDTC) as Cr(Ⅲ)-DDTC complex from acetate buffered aqueous, solution of pH 5.4 and the direct current polarogram for the extract was recorded after addition of sodium perchlorate as supporting electrolyte. The reduction current was diffusion controlled. And the half wave potential of this reduction wave was -0.81 volt vs. SCE. The diffusion current was proportional to the chromium concentraticn in aqueous solution in the range of 8∼160 ppm. And the chromium(Ⅵ) could be selectively determined in the presence of chromium(Ⅲ), since the chromium(Ⅲ) did not interfere up to twice the amount of chromium(Ⅵ). Many of other metals such as Mn(Ⅱ), Cu(Ⅲ), Zn(Ⅱ), Mg(Ⅱ), Ni(Ⅱ) and Ag(Ⅰ) were found to have no effect even when present in 1000 times the amount of chromium (Ⅵ).

  • PDF

A Study on Synthesis Catalysts for Vinylester Resin (비닐에스테르 수지의 합성촉매에 관한 연구)

  • Hong, Suk-Pyo;Choi, Sang-goo
    • Applied Chemistry for Engineering
    • /
    • v.2 no.3
    • /
    • pp.229-237
    • /
    • 1991
  • Vinylester was syntheszed in the presence of amine and metal catalysts, such as triethylamine(TEA), triethylbenzyl ammonium chloride (TEBAC), cetyltrimethyl ammonium bromide (CTMAB), chromium acety] acetate (CAA), and triphenylantimony (TPA). Apropriate use of amine and organometal catalysts were 1.7~2.2 % (Wt. %), 2.5~3.1 % (Wt %) of charged methacrylic acid (MAA) in respect of reactivity, gel-time, and storage stability. The Order of reactivity was TEA>TEBAC>CTMAB>CAA>TPA. Temperature independence of catalyst showed more large deviation above $110^{\circ}C$. Storage stability could be improved without delay of gel-time by adding TPA in 2.0 % (Wt %) of charged MAA after synthesis.

  • PDF

Formation of Reactive Oxygen Species and Cr(V) Entities in Chromium(VI) Exposed A549 Cells (크롬 6가 투여 후 A549 세포에서의 Reactive Oxygen Species와 크롬 5가의 발생)

  • 박형숙
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.49-57
    • /
    • 1996
  • The production of reactive oxygen species on addition of hexavalent chromium (potassium dichromate, $K_2Cr_2O_7$ ) to lung cells in culture was studied using flow cytometer analysis. A Coulter Epics Profile flow cytometer was used to detect the formation of reactive oxygen species after $K_2Cr_2O_7$ was added to A549 cells grown to confluence. The cells were loaded with the dye, 2',7'-dichlorofluorescein diacetate, after which cellular esterases removed the acetate groups and the dye was trapped intracellularly. Reactive oxygen species oxidized the dye, with resultant fluorescence. Increased doses of Cr(VI) caused increasing fluorescence (10-fold higher than background at 200 gM). Addition of Cr(III) compounds, as the picolinate or chloride, caused no increased fluorescence. Electron paramagnetic resonance (EPR) spectroscopic studies indicated that three (as yet unidentified) spectral "signals" of the free radical type were formed on addition of 20, 50, 100 and 200 gM Cr(VI) to the A549 cells in suspension. Two other EPR 'signals" with the characteristics of Cr(V) entities were seen at field values lower than the standard free radical value. radical value.

  • PDF

Determination of Chromium(VI) by Differential-Pulse Polarography with a Sodium Borate Supporting Electrolyte

  • Hong, Tae-kee;Czae, Myung-Zoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.2
    • /
    • pp.77-80
    • /
    • 1988
  • A suituable choice of supporting electrolyte medium for trace level determinations of chromium(VI) by differential pulse polarography is described. A comparative study suggests that sodium borate buffer is superior to ammonium acetate, ammonium tartrate, and especially to NaF which was recently known to be one of the most proper medium for the purpose. With 0.01 M borate, the best combination of high sensitivity, well-defined base line, and freedom from common interferents was attained. With $5.0{\times}10^{-7}$M Cr(VI), tenfold excesses of Cu(II) and Fe(III), and a five hundred-fold excess of $Cl^-$ do not change the peak current by more than about 1%. And the detection limit was $5.0{\times}10^{-8}$M Cr(VI).

Evaluation of Workers' Exposures to Airborne Lead chromate in the Producing and Using Industries (국내 무기안료 제조 및 취급 공정에서의 공기 중 크롬산연 노출 평가)

  • Choi, Ho Chun;An, Sun Hee;Lee, Hyun Seok;Kim, Hwa Sung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.4
    • /
    • pp.293-302
    • /
    • 2008
  • Lead chromate is made by sodium dichromate and lead acetate, and has being used widely in the part of pigment, paints, inks, plastics and so on. Even though lead chromate has health hazards which like both lead and chromium, there are a few study about pigment workplaces using lead chromate in Korea. The purpose of this study is to evaluate workers' exposure levels and airborne lead and chromium concentration in the pigment workplaces using lead chromate. There are 20 workers in the total 5 workplaces. 10 workers(50%) have been exposed to lead and 3 workers(15%) have been exposed to chromium, which exceeded the American Conference of Governmental Industrial Hygienists(ACGIH) Threshold Limit Value (Pb: $0.05\;mg/m^3$, Cr: $0.012\;mg/m^3$) and Korean Ministry of Labor's Standard. Geometric mean (GM) of airborne lead was highest in pigment ($0.0421\;mg/m^3$), paint ($0.0020\;mg/m^3$) and PVC coloring ($0.0007\;mg/m^3$), respectively(p<0.05). The result of airborne chromium concentration was paint ($0.0033\;mg/m^3$), paint ($0.0004\;mg/m^3$) and PVC coloring ($0.0003\;mg/m^3$). Also the lead and chromium concentration in the manual process is each 30 times and 10 times higher than the value in automatic process(p<0.01). In the classified process by detail, the concentration of airborne lead was $0.0638\;mg/m^3$ in grinding & packaging, mixture & after-measuring ($0.0436\;mg/m^3$), filtration & drying ($0.0402\;mg/m^3$), lead nitrate & dissolution($0.0129\;mg/m^3$), pigment commitment & mixture ($0.0013\;mg/m^3$) and dispersion & grinding ($0.0010\;mg/m^3$) (p<0.05). Moreover the concentration of a sample in weighting & packaging was $0.0023\;mg/m^3$. The concentration of lead in workers' blood was pigment (15.12 ug/dl), paint (4.74 ug/dl) and PVC coloring (2.50 ug/dl), and some samples have exceeded biological exposure limit. In conclusion, the depending on their work industry and process, workers have been exposed to the high lead chromate.

Syntheses of Metallic Monoazo Complexes (Monoazo 金屬錯염의 合成)

  • Hahn, Chi-Sun;Park, Dae-Chul;Nam-Goong, Ha-Il;Kang, Yong-Ik
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.99-105
    • /
    • 1968
  • Some ortho-hydroxy monoazo-compounds have been synthesized and these were metallized with transition elements. Chromium trioxide, cupric acetate and cobalt acetate were used for the metallization. The following facts have been found in this investigation: (1) water is the best solvent, when compared to various organic solvents, for the metallization, (2) the optimum pH for the metallizing mixture ranges from 4.5 to 5.5, (3) the solubility of these metallic monoazo-compounds in water depends mainly on the composition of the complexes and to some extent on the presence of sulfonic acid groups in the molecules, and (4) metallized compounds having two ortho-hydroxy groups per molecule have stronger binding characteristics.

  • PDF

Dyeing with Natural Dye (II) ―Dyeing of Silk with Sappan Wood― (천연염료에 의한 염색(II) ―소목에 의한 견염색―)

  • Nam, Sung Woo;Chung, In Mo;Kim, In Hoi
    • Textile Coloration and Finishing
    • /
    • v.7 no.4
    • /
    • pp.87-96
    • /
    • 1995
  • Colorant concentrates are prepared by use of concentration method of colorants extracted from Sappan wood using met hanol. Dyeabilities and fastness properties of silk fabrics dyed with concentrate of Sappan wood are investigated.The results obtained are as follows; 1. The storage stability of colorant concentrate is poor as concentration is excess. 2. Because the colors of dyeings are different with mordants, aluminium acetate, copper acetate, chromium alum and tin chloride are used in order to obtain reddish color. 3. The optimum dyeing temperature and dyeing time are 6$0^{\circ}C$ and 60 min, respectively. 4. Dry cleaning fastness is very good, and light fastness and washing fastness are low. 5. The dyeing method is simple owing to usehess of colorant concentrate prepared without extraction of colorant every time.

  • PDF