• Title/Summary/Keyword: Chromium

Search Result 1,434, Processing Time 0.029 seconds

Reduction of Hexavalent Chromium on PVC Filters (혜산산업보건학술상 수상논문 - PVC 여과지에 채취된 6가 크롬의 환원)

  • Sin, Yong-Cheol
    • 월간산업보건
    • /
    • s.356
    • /
    • pp.16-25
    • /
    • 2017
  • Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidationreduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 ; 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 ; 89.9) at 1 hour and 81.0% (78.3 ; 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 ; 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  • PDF

Effect of Carcinogenic Chromium(VI) on Cell Death and Cell Cycle in Chinese Hamster Ovary Cells

  • Lee, San-Han;Nam, Hae-Seon;Kim, Sung-Ho
    • Environmental Mutagens and Carcinogens
    • /
    • v.24 no.3
    • /
    • pp.113-120
    • /
    • 2004
  • Chromium compounds are known human and animal carcinogens. In this study, the effects of sodium chromate on apoptosis and cell cycle were investigated in order to unveil the elements of early cellular responses to the metal. Using Chinese hamster ovary cells(CHO-K1-BH4), we found taht chromium (VI) treatment induced apoptosis in these cells, as signified by nuclear fragmentation, DNA laddering on agarose gel electrophoresis, and an increased proportionof cells with hypodiploid DNA. Preceding these changes, chromium (VI) treatment increased caspase 3 pritease activity and also increased expression of p53 protein, while the level of bcl2 protein was not changed. Coincubation with caspase inhibitor, Z-DEVD-FMK, inhibited chromium-induced apoptosis. In the flow cytometric analysis using propidium iodide fluorescence, an increase of cell population in G2/M phase was shown in cells exposed to at least 160 $\mu\textrm{m}$ of sodium chromate for 72h, form 9.8% for 0$\mu\textrm{m}$ chromium (VI) to 26.4% for 320$\mu\textrm{m}$ chromium(VI). Taken together, these findings suggest that chromium(VI)-induced apoptosis is accompanied by G2/M cell cycle arrest, and that p53-mediated pathway may be involved in positive regulation of G2/M arrest and a concurred apoptosis in CHO cells.

  • PDF

Long-term teaching Characteristics of Hexavalent Chromium Contaminated Soils Treated with Phosphate and Chromium Reducing Agent (크롬환원제와 인산염으로 처리된 6가 크롬 오염토양의 장기용출 특성)

  • Lee Eui-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.448-452
    • /
    • 2006
  • This study was performed to evaluate the long-term teachability of the stabilized hexavalent chromium contaminated soils treated with chromium reducing agent and soluble phosphate. The study shows that $Cr^{6+}$ in the leachate was little detected and the remaining $PO_4-P$ concentration kept below 0.1 mg/L due to the formation of geochemically stable hexavalent chromium phosphate minerals from the reactions of labile soil $Cr^{6+}$ forms with the added soluble phosphate salt and chromium reducing agent. The results provide evidence for the potential use of the immobilization technique for the hexavalent chromium contaminated soil remediation in the near future.

  • PDF

Environment Emission and Material Flow Analysis of Chromium in Korea

  • Shin, Dong-won;Kim, Jeong-gon
    • Journal of Powder Materials
    • /
    • v.22 no.3
    • /
    • pp.187-196
    • /
    • 2015
  • With the stabilization of Korea's industrialization, it has become interested in the efficient use of rare metals, climate change and industrial environment and safety etc. It is thus making efforts to implement economic policies that address such issues. Therefore it is necessary to understand the demand, supply and use of metal materials. Since 2010, the Korean government has developed the integrated material flow methodology and has been trying to examine the demand, supply and use of metal materials. In 2013, the Korean government surveyed the material flow of chromium. Material flow analysis and environment emission of chromium were investigated 8 steps; (1) raw material, (2) first process, (3) Intermediate product, (4) End product, (5) Use/accumulation, (6) Collection, (7) Recycling, (8) Disposal. Chromium was used for stainless steel, alloy steel, coated sheets, refractory material and coating materials. Recycling was done mainly in use of stainless steel scrap. To ensure efficient use of chromium, process improvement is required to reduce the scrap in the intermediate product stage. In the process of producing of the products using chromium, it was confirmed that chromium was exposed to the environment. It requires more attention and protection against environment emission of chromium.

The effect of Na2MoO4 addition on the formation and corrosion resistance of Cr-electroplated layer of low carbon steel (저탄소강의 크롬도금층 형성 및 내식성에 미치는 Na2MoO4 첨가의 영향)

  • Bae, Ki Chang;Kim, Kiwook;Kim, Juho;Lee, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.1
    • /
    • pp.18-23
    • /
    • 2022
  • Presence of cracks in electrodeposited hard chromium layer, which provide a path of corrosive media to steel substrate, is a serious issue in metal finishing with chromium electroplating. In this study, we added sodium molybdate in an electrolyte for chromium electroplating bath. 130g/L of sodium molybdate in Sargent bath for chromium electroplating causes a codepostion of molybdenum with chromium in a rage of 0.61 ~ 3.14 wt.%. The co-deposited molybdenum enhances the crystallinity of chromium layer, thus the hardness is slightly decreases by the addition of molybdate in electrolyte. However, due to the co-deposition of molybdenum, a crack-free chromium layer could be electrodeposited. Such crack-free chromium layer shows a significantly improved corrosion resistance.

EFFECTS OF DIETARY LEVELS OF CHROMIUM PICOLINATE ON GROWTH PERFORMANCE, CARCASS QUALITY AND SERUM TRAITS IN BROILER CHICKS

  • Kim, Y.H.;Han, In K.;Choi, Y.J.;Shin, I.S.;Chae, B.J.;Kang, T.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.3
    • /
    • pp.341-347
    • /
    • 1996
  • An experiment was conducted to evaluate the effects of dietary levels of chromium in the form of chromium picolinate on growth performance, nutrient utilizability, carcass composition, serum traits, and in vitro lipolysis and lipogenesis in adipose tissues of Arbor Acre broiler chicks. Experimental diets containing six different levels of chromium (0, 100, 200, 400, 600 and 800 ppb) were fed for 6 weeks. Individual treatment had six replicates of eight birds each and their average initial weight was 59.2 g. Dietary addition of chromium did not affect growth performance and nutrient utilizability. However, mortality appeared to be reduced with addition of chromium to the diet. It was obvious that chromium supplementation significantly decreased serum cholesterol and increased serum HDL cholesterol (p < 0.05), but serum insulin, glucose, triglyceride and non-esterified fatty acid concentrations were inconsistent among dietary supplementation levels of chromium. The in vitro lipolysis and lipogenesis in adipose tissues were significantly influenced by dietary addition of chromium (p < 0.05). Chicks fed diets containing 200 or 400 ppb chromium showed the highest protein content and the lowest fat content in their carcass.

Chromium and nickel concentrations in air and in serum of workers in chromium and nickel electroplating plants (도금업 근로자의 혈청과 공기중 크롬 및 니켈 농도)

  • Choi, Ho Chun;Kim, Hae Jeong;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.117-127
    • /
    • 1991
  • The exposure level of chromium and nickel for chrome and nickel plating workers were evaluated. Chromium and nickel concentrations in serum from 82 exposed workers and 66 controls, who were not exposed occupationally to metals, were analyzed by flameless atomic absorption spectrophotometry. The results were as follows : 1. The recovery percent of chromium and nickel concentrations in personal air samples were 95-108.2%, 88.0-107.7%, precisions (C.V., %) were 2.7-3.1%, 2.1-4.4%. respectively. 2. The recovery percent of chromium and nickel concentrations in serum were 93.6-106.4%, 91.3-107.9% and precisions (C.V. %) were 1.1-7.6%, 2.4-5.4% respectively. 3. The exposure level of chromium and nickel concentrations in the place of preparation process were $2.0{\pm}2.00{\mu}g/m^3$, chromplating were $35.7{\pm}53.07{\mu}g/m^3$, $2.8{\pm}3.42{\mu}g/m^3$, nickelplating were $4.6.0{\pm}5.8{\mu}g/m^3$, $18.62{\pm}4.41{\mu}g/m^3$, and covering were $2.9{\pm}2.02{\mu}g/m^3$, $1.1{\pm}0.47{\mu}g/m^3$ respectively. There were significant difference of concentrations for chromium and nickel in workplaces by groups statistically. 4. Chromium concentrations in serum of exposed group and control were $0.68{\pm}0.399{\mu}g/l$, $1.41{\pm}0.748{\mu}g/l$, respectively. There were significant difference of concentrations for chromium and nickel in serum by groups statistically. 5. Chromium and nickel concentrations in serum of exposed group were not significant by workplaces.

  • PDF

A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration (중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구)

  • Cheong, Hoe Kyeong;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF

Separation of Chromium(VI) Ion in Industrial Waste Water throunh Liquid Surfactant Membrane (산업폐수중 유화액막에 의한 크롬(VI)의 분리)

  • 초민승;강안수;우인성;이영순
    • Journal of the Korean Society of Safety
    • /
    • v.4 no.1
    • /
    • pp.15-24
    • /
    • 1989
  • The transport of Chromium(Vl) ion from waste water throughl the liquid surfactant membrane containing tri-n-octylamine as a carrier, was analyzed by a slab model and was investigated through experiments. For the experiment of membrane stability, concentrations of surfactant and liquid parafnn oil were analyzed. Extraction euperiments were carried out to observe the effect of system variables, such as stirring speed, concentration of carrier, and NaOH in internal aqueous phase, and concentrations of H$_2$SO$_4$and initial chromium(VI) ion in external aqueous phase at $25^{\circ}C$. It is concluded that the most stable formation of liquid membrane emulsion was obtained when surfactant concentration is above 3 wt. % and liquid parafnn oil concentration is 50 vol. %. The transport of chromium(VI) ion in bacth extractor increased with increasing carrier concentration, the volume ratio of emulsion to external aqueous phases, and initial concentration of chromium(VI) ion under the optimum stirring speed of chromium(VI) ion below 2 ppm. The theoretical equation on the transport of chromium(Vl) ion agreed well with the experimental results.

  • PDF

Fabrication of Chromium-based Double Layered Deposit (크롬계 이중도금층 제조 및 특성평가)

  • Park, Sang-Eon;Kim, Dong-Su;Kim, Man;Jang, Do-Yeon;Gwon, Sik-Cheol
    • 연구논문집
    • /
    • s.31
    • /
    • pp.127-133
    • /
    • 2001
  • In chromium electrodeposition, crack is inevitably accompanied by chromium layer. Behavior of crack formation and crack density were different from the plating conditions such as current density, temperature, waveform of applied current and so on. And cracks have an influence on the corrosion resistance of chromium deposit, because corrosion occurs through the network of cracks between deposit and substrate. Therefore, many researches have been achieved in order to remove the cracks in chromium deposit. Formation of double layers, Cr/Cr and Ni/Cr were investigated to increase corrosion resistance of chromium deposit in this study. As pretreatment prior to outer chromium coating, acid pickling and current control method were examined. Cracks in cross-section of each sample were observed with SEM and CASS(Copper modified acetic acid salt spray) test was performed to evaluate corrosion resistance. It was found that corrosion resistance of Cr/Cr and Ni/Cr double layers were superior to Cr or Ni single layer from the results of CASS test.

  • PDF