• 제목/요약/키워드: Choi JIG

검색결과 66건 처리시간 0.027초

혼합모드(Mode I+II)구현을 위한 2축 피로시험 JIG 설계 (Design of 2 Axles Fatigue Test JIG for the Materialization of Mixed Mode (Mode I+II))

  • 최성대;정선환;김기만;김잠규;최명수;김우재
    • 한국산업융합학회 논문집
    • /
    • 제11권2호
    • /
    • pp.59-64
    • /
    • 2008
  • Elements of a mechanical structure are getting from multi-axles stress. so fatigue characteristic experiment Shall execute in multi-axles stress state. it is very hard to apply according to forms of a testing machine and implementation. In this study, 2 axles fatigue testing machine did a design and Development. a new JIG developed to realize a mixed mode. a stress state in mixed mode of a specimen had each other comparison using the Finite element method to examine propriety of a new JIG.

  • PDF

고전압 장비 지그의 동특성에 대한 위상, 형상 및 치수 최적화 (Topology, Shape and Sizing Optimization of the Jig Supporting High Voltage Pothead)

  • 최봉균;이재환;김영중
    • 한국전산구조공학회논문집
    • /
    • 제26권5호
    • /
    • pp.351-358
    • /
    • 2013
  • 본 논문에서는 Pothead를 지지하는데 사용하는 지그의 고유진동수를 일정 범위로 제한하여 Pothead와 공진을 일으키지 않도록 하는 지그의 최적 설계안을 제시한다. 쿤 터커(Kuhn-Thucker) 조건을 적용한 최적기준법(Optimality criteria method)을 사용하여 위상 최적화를 수행하였고, 이 과정에서 유한요소 크기기 최적 형상에 미치는 영향을 검토하였다. 또한 위상 최적화 결과를 바탕으로 실험 계획법(Design of experiments)과 반응 표면법(Response surface method)을 사용하여 형상 및 치수 최적화를 수행하여 비교용 지그에 비해 전체 질량이 30% 감소되는 결과를 얻었다. 마지막으로 최적화된 지그의 내진 해석을 수행한 Pothead의 응답은 Metal Handbook에서 제시된 내진 응답을 만족하고 있다.

하악 중심위 유도방법에 따른 하악위의 재현성 및 변위량에 관한 비교연구(LEAF GAUGES의 사용을 중심으로) (A COMPARATIVE STUDY ON THE REPRODUCIBILITY AND THE DISPLACEMENT OF CENTRIC RELATION RECORDS (BETWEEN LEAF GAUGES AND OTHER METHODS))

  • 최진웅;최대균;박남수;최부병
    • 대한치과보철학회지
    • /
    • 제26권1호
    • /
    • pp.133-151
    • /
    • 1988
  • The objectives of this study were to compare the position of centric relation guided by means of leaf gauges, bilateral manipulation, chin-point guidance with Lucia jig and self-guided method and the reproducibility, respectively. A Veri-check (Denar Co., Anaheim, California) was employed for examining, and the displacement of position and reproducibility were verified. The following results were obtained. 1. On the sagittal plane, the centric relation guided by means of leaf gauges showed greater posterior displacement than that by means of bilateral manipulation and less than that by means of chin-point guidance with Lucia jig, and self-guided centric relation showed least posterior displacement. The centric relation guided by means of bilateral manipulation showed greater superior displacement than that by means of chin-point guidance with Lucia jig and less than that by means of leaf gauges and self-guided centric relation showed least superior displacement. 2. On the horizontal plane, the centric relation guided by means of chin-point guidance with Lucia jig showed greater posterior displacement than that of bilateral manipulation and less than that leaf gauges, however the self-guided centric relation showed slightly anterior displacement. 3. The anteroposterior displacement measured on sagittal plane and horizontal plane were highly correlated. (p<0.05). 4. The reproducibility of centric relation guided by means of leaf gauges, bilateral manipulation and chin-point guidance with Lucia jig were similar and more reproducible than self-guided centric relation.

  • PDF

해양구조물 작업대 승하강 조절용 핀지그의 경량화를 위한 최적설계 (Optimum Design of Pin Jig to Control Ascent and Descent Offshore Structure Work Table for Weight Reduction)

  • 홍도관;우병철;최석창;박일수;안찬우;한근조;강헌찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.1051-1054
    • /
    • 2005
  • On this study, we optimized minimizing the characteristic function for mixed result of the structural contact analysis and the buckling analysis according to the pin jig initial model's level change using mixed the table of orthogonal away and ANOM, Pin jig's weight is reduced up to 20 percent considering constraint conditions. Also we optimized reducing 20 percent weight of pin jig model using topology optimization.

  • PDF

관형 고체산화물연료전지 테스트 지그 최적화 (Optimal Design for Tubular SOFC Testing Jig)

  • 최훈;안권성;신창우;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.303-306
    • /
    • 2009
  • High temperature solid oxide fuel cells (SOFCs) offer a clean, pollution-free technology to electrochemically generate electricity at high efficiencies. Solid oxide fuel cells in several different designs have been investigated; these include planar and tubular geometries. The tubular type cell is widely researched due to it have advantages about thermal expansion and sealing issues. Unfortunately, lab scale tubular cell for testing has thermal expansion and sealing problems. The previous Jig for lab scale tubular cell testing has many sealing problems. When we feed fuel gas to jig inlet, ceramic glue sealant has amount of gas expansion pressure, because temperature of feeding gas changes ambient temperature to high temperature ($700{\sim}900^{\circ}C$). Furthermore, when we carry out long time test, something like degradation test, crack of ceramic glue sealant due to weakness of mechanical properties can make stop working the test. Additionally, we reduce setting process for assembling, because micanite is not required drying or debinding process.

  • PDF

고선량 Ir-192선원 교정기의 제작 및 특성 (High Dose Rate Ir-192 Source Calibration Method with Newly Designed Calibration Jig)

  • 이병용;최은경;장혜숙
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.299-303
    • /
    • 1989
  • Authors have developed highly reproducible calibration method for the Micro-Selectron HDR Ir-192 system (Nucletron, Motherland). The new jig has a 10cm radius circular hole in the $30cm{\times}30cm{\times}0.2cm$ acrylic plate, and 5F flexible bronchial tubes are attached around the hole. The source moves along the circle in the tubes and the ionization chamber is placed verticaly at the center of the circular hole (center of the jig). Dose distribution near the center was derived theoretically, and measured with the film dosimetry system. Theoretical calculation and measurement show the error margin below $0.1\%$ for 1mm or 2mm position deviation. We have measured at 12 and 24 points of circle with 1, 6, 11 and 21 second dwell time of source in order to calculate the activity of the source. Measurements have been repeated daily for 50 days. The accuracy and the reproducibility are below $1\%$ error margin. The half life of the source from our measurement is estimated $73.4\pm0.4$ days.

  • PDF

다양한 생태계에서 분리한 황 산화 세균 (Isolation of Sulfur Oxidizing Bacteria from Different Ecological Niches)

  • ;;;;;최관호;사동민
    • 한국토양비료학회지
    • /
    • 제38권4호
    • /
    • pp.180-187
    • /
    • 2005
  • 다양한 인도 토양에서 Starkey's 배지를 이용하여 9종류의 화학합성독립영양 및 12종류의 화학합성종속영양 황산화 세균을 분리하였다. 분리한 세균은 황을 황산으로 산화시키는 기능이 있으며 생육 중 배지의 산도를 감소시켰다. 분리한 황 산화 세균은 혐기 조건에서는 생육하지 못했다. 화학합성독립영양세균 SGA6 및 JIG 2종만이 포도당을 이용하는 능력이 있었으며, LCH 1종을 제외한 모든 분리세균은 thiosulfate를 에너지원으로 이용하였다. 분리한 세균 중 황 산화 능력이 가장 우수한 것은 화학합성독립영향세균인 LCH이었으며 화학합성종속영향세균인 JIG의 황 산화 능력이 가장 낮았다. 분리한 황 산화 세균을 이용하여 점토를 이용하여 입제형태로 만들었을 때 균의 밀도는 약 $2.5{\times}10^7cfu\;g^{-1}$ 이었다.

측정용 전리함에 따른 고 선량율 근접치료용 방사성 선원의 겉보기 활성도의 정확도 비교 분석 (Analysis of Accuracy of Apparent Activity According to Calibration Method for High Dose Rate Brachytherapy Source)

  • 허현도;최진호;최상현;김성훈;김우철;김헌정;이레나;김금배;홍성언;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.305-312
    • /
    • 2008
  • 본 연구에서는 측정 방법이 다른 두 전리함을 이용하여 고선량율 근접치료용 방사성 선원의 겉보기 활성도를 측정하여 선원의 활성도 정확성 및 두 장비간의 정확도를 비교 분석하였다. 국내 5개 의료기관을 선정하여 공기 중 기준거리에서 겉보기 활성도를 측정하고 동일한 선원에 대하여 측정 방법이 다른 두 팬톰을 동시에 측정하여 측정방법에 따른 상호 오차와 측정용 전리함의 정확도를 평가하였다. 우물형 전리함과 Jig 팬톰의 상대 오차는 각각 -2.1%~0.2%, -2.8%~-1.0%로 나타났다. 동일한 방사성선원에 대하여 두 교정 장비간의 정확도 평가는 최대 상대오차 1%로 나타났다. 선원의 세기 검증 시 측정 방법에 따른 의존도는 없었다. 고 선량율 근접방사선치료에 사용되는 방사성 선원의 세기의 변화는 환자의 종양 및 인접장기에 미치는 영향이 매우 크므로 방사성 선원의 세기 오차는 환자치료의 최적화에 심각한 영향을 미칠 수 있다. 그러므로 새로운 선원 교체 시 뿐만 아니라 주기적인 선원 점검이 요구된다.

  • PDF