Design of 2 Axles Fatigue Test JIG for the Materialization of Mixed Mode (Mode I+II) (혼합모드(Mode I+II)구현을 위한 2축 피로시험 JIG 설계)

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Kim, Gi-Man;Kim, Jam-Kyu;Choi, Myoung-Su;Kim, Woo-Jae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.2
    • /
    • pp.59-64
    • /
    • 2008
  • Elements of a mechanical structure are getting from multi-axles stress. so fatigue characteristic experiment Shall execute in multi-axles stress state. it is very hard to apply according to forms of a testing machine and implementation. In this study, 2 axles fatigue testing machine did a design and Development. a new JIG developed to realize a mixed mode. a stress state in mixed mode of a specimen had each other comparison using the Finite element method to examine propriety of a new JIG.

  • PDF

Topology, Shape and Sizing Optimization of the Jig Supporting High Voltage Pothead (고전압 장비 지그의 동특성에 대한 위상, 형상 및 치수 최적화)

  • Choi, Bong-Kyun;Lee, Jae-Hwan;Kim, Young-Joong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.5
    • /
    • pp.351-358
    • /
    • 2013
  • In the electric power supplying industry, outdoor sealing end (pothead) is used and sometimes it is necessary to check the seismic qualification analysis or test which is intended to demonstrate that the equipment have adequate integrity to withstand stress of the specified seismic event and still performs their function. And since the pothead is mounted on the supporting jig, the avoidance of resonance between the pothead and jig is required. In order to design jig, three types of optimization are performed to get the minimum weight while satisfying the natural frequency constraint using ANSYS. Optimal array, position and thickness of truss members of the jig are obtained through topology, shape and sizing optimization process, respectively. And seismic analysis of the pothead on the jig for given RRS acceleration computes the displacement and stress of the pothead which shows the safety of the pothead. The obtained natural frequency, mass, and member thickness of the jig are compared with those of the reference jig which was used for seismic experimental test. The numerical results of the jig in the research is more optimized than the jig used in the experimental test.

A COMPARATIVE STUDY ON THE REPRODUCIBILITY AND THE DISPLACEMENT OF CENTRIC RELATION RECORDS (BETWEEN LEAF GAUGES AND OTHER METHODS) (하악 중심위 유도방법에 따른 하악위의 재현성 및 변위량에 관한 비교연구(LEAF GAUGES의 사용을 중심으로))

  • Choi, Jin-Woong;Choi, Dae-Gyun;Park, Nam-Soo;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.133-151
    • /
    • 1988
  • The objectives of this study were to compare the position of centric relation guided by means of leaf gauges, bilateral manipulation, chin-point guidance with Lucia jig and self-guided method and the reproducibility, respectively. A Veri-check (Denar Co., Anaheim, California) was employed for examining, and the displacement of position and reproducibility were verified. The following results were obtained. 1. On the sagittal plane, the centric relation guided by means of leaf gauges showed greater posterior displacement than that by means of bilateral manipulation and less than that by means of chin-point guidance with Lucia jig, and self-guided centric relation showed least posterior displacement. The centric relation guided by means of bilateral manipulation showed greater superior displacement than that by means of chin-point guidance with Lucia jig and less than that by means of leaf gauges and self-guided centric relation showed least superior displacement. 2. On the horizontal plane, the centric relation guided by means of chin-point guidance with Lucia jig showed greater posterior displacement than that of bilateral manipulation and less than that leaf gauges, however the self-guided centric relation showed slightly anterior displacement. 3. The anteroposterior displacement measured on sagittal plane and horizontal plane were highly correlated. (p<0.05). 4. The reproducibility of centric relation guided by means of leaf gauges, bilateral manipulation and chin-point guidance with Lucia jig were similar and more reproducible than self-guided centric relation.

  • PDF

Optimum Design of Pin Jig to Control Ascent and Descent Offshore Structure Work Table for Weight Reduction (해양구조물 작업대 승하강 조절용 핀지그의 경량화를 위한 최적설계)

  • Hong D.K.;Woo B.C.;Choi S.C.;Park I.S.;Ahn C.W.;Han G.J.;Kang H.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.1051-1054
    • /
    • 2005
  • On this study, we optimized minimizing the characteristic function for mixed result of the structural contact analysis and the buckling analysis according to the pin jig initial model's level change using mixed the table of orthogonal away and ANOM, Pin jig's weight is reduced up to 20 percent considering constraint conditions. Also we optimized reducing 20 percent weight of pin jig model using topology optimization.

  • PDF

Optimal Design for Tubular SOFC Testing Jig (관형 고체산화물연료전지 테스트 지그 최적화)

  • Choi, Hoon;An, Gwon-Seong;Shin, Chang-Woo;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.303-306
    • /
    • 2009
  • High temperature solid oxide fuel cells (SOFCs) offer a clean, pollution-free technology to electrochemically generate electricity at high efficiencies. Solid oxide fuel cells in several different designs have been investigated; these include planar and tubular geometries. The tubular type cell is widely researched due to it have advantages about thermal expansion and sealing issues. Unfortunately, lab scale tubular cell for testing has thermal expansion and sealing problems. The previous Jig for lab scale tubular cell testing has many sealing problems. When we feed fuel gas to jig inlet, ceramic glue sealant has amount of gas expansion pressure, because temperature of feeding gas changes ambient temperature to high temperature ($700{\sim}900^{\circ}C$). Furthermore, when we carry out long time test, something like degradation test, crack of ceramic glue sealant due to weakness of mechanical properties can make stop working the test. Additionally, we reduce setting process for assembling, because micanite is not required drying or debinding process.

  • PDF

High Dose Rate Ir-192 Source Calibration Method with Newly Designed Calibration Jig (고선량 Ir-192선원 교정기의 제작 및 특성)

  • Yi, Byong-Yong;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.299-303
    • /
    • 1989
  • Authors have developed highly reproducible calibration method for the Micro-Selectron HDR Ir-192 system (Nucletron, Motherland). The new jig has a 10cm radius circular hole in the $30cm{\times}30cm{\times}0.2cm$ acrylic plate, and 5F flexible bronchial tubes are attached around the hole. The source moves along the circle in the tubes and the ionization chamber is placed verticaly at the center of the circular hole (center of the jig). Dose distribution near the center was derived theoretically, and measured with the film dosimetry system. Theoretical calculation and measurement show the error margin below $0.1\%$ for 1mm or 2mm position deviation. We have measured at 12 and 24 points of circle with 1, 6, 11 and 21 second dwell time of source in order to calculate the activity of the source. Measurements have been repeated daily for 50 days. The accuracy and the reproducibility are below $1\%$ error margin. The half life of the source from our measurement is estimated $73.4\pm0.4$ days.

  • PDF

Isolation of Sulfur Oxidizing Bacteria from Different Ecological Niches (다양한 생태계에서 분리한 황 산화 세균)

  • Anandham, Rangasamy;Sridar, Ragupathy;Nalayini, Periyakaruppan;Madhaiyan, Munusamy;Gandhi, Pandiyan Indira;Choi, Kwan-Ho;Sa, Tong-Min
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.4
    • /
    • pp.180-187
    • /
    • 2005
  • Nine chemolithoautotrophic and 12 chemolithoheterotrophic sulfur oxidizing bacteria were isolated using enrichment technique in modified Starkey's medium. All isolates reduced pH of the growth medium through oxidation of elementai sulfur to sulfuric acid. Isolates utilized the thiosulfate as energy source except LCH. None of the isolates grew anaerobically and utilization of glucose was found only in chemolithoheterotrophic isolates SGA6 and JIG. In vitro sulfate production from elemental sulfur was found maximum for chemoiithoautotroph LCH ($43.2mg\;100\;mL^{-1}$) and least for chemolithoheterotroph JIG ($10.04mg\;100\;mL^{-1}$). The above tests suggested that all isolates belong to the member of Thiobacillus. For field inoculation of Thiobacillus, clay based pellet formulation was developed with the cell load of $2.5{\times}10^7cfu\;g^{-1}$ of pellet. It is easy to handle by the farmers and more likely to lead to successful farming.

Analysis of Accuracy of Apparent Activity According to Calibration Method for High Dose Rate Brachytherapy Source (측정용 전리함에 따른 고 선량율 근접치료용 방사성 선원의 겉보기 활성도의 정확도 비교 분석)

  • Huh, Hyun-Do;Choi, Jin-Ho;Choi, Sang-Hyoun;Kim, Seong-Hoon;Kim, Woo-Chul;Kim, Hun-Jeong;Lee, Re-Na;Kim, Kum-Bae;Hong, Seong-Eon;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.305-312
    • /
    • 2008
  • The aim of this study is to introduce the accuracy of Ir-192 source's apparent activity using the well-type chamber and the Farmer-type ionization chamber in the high dose rate brachytherapy. We measured the apparent activity of Ir-192 that each medical center in the country has and the apparent activity of calibration certificate provided by manufacturer is compared with that by our experimental measurement. The number of sources used for the activity comparison was 5. The accuracy of the measured activity was in the range of -2.8% to -1.0% and -2.1% to 0.2% for the Farmer-type chamber system (Jig) and for the well-type, respectively. The maximum difference was within 1.0% for comparison with two calibration's tool. Our results demonstrate that well-type chamber as wall as Farmer-type chamber is a appropriate system as the routine source calibration procedures in HDR brachytherapy. Whenever a new source is installed to use in clinics, by periods, a source calibration should be carried out.

  • PDF