• Title/Summary/Keyword: Choi, In-hoon

Search Result 7,340, Processing Time 0.047 seconds

The Quantitative Evaluation of Cardiac Calcification Using 18F-Sodium fluoride PET/CT (18F-Sodium fluoride PET 이용한 심장 석회화 정량평가에 대한 고찰)

  • Choi, Yong Hoon;Lee, Seung Jae;Kang, Chun Goo;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.38-42
    • /
    • 2019
  • Purpose Although computed tomography (CT) is used for coronary artery calcification, it is difficult to differentiate between high risk microcalcifications. Studies have shown that $^{18}F$-sodium fluoride ($^{18}F-NaF$) is very useful for the diagnosis of microcalcifications. In this study, we aimed to evaluate the usefulness of $^{18}F-NaF$ PET imaging in quantitative evaluation of calcification. Materials and Methods A total of 45 patients ($67.1{\pm}6.9years\;old$) were injected with 250 MBq of $^{18}F-NaF$ for 1 hour and images were acquired for 30 minutes. All patients underwent CT angiography (CTAngiography, CTA) before the PET scan. The SUVmax of calcification was measured and the background radioactivity of the left atrium was measured to determine Target to Background (TBR) and quantitatively analyzed. High risk group was classified through ROC curve (Receiver Operating Characteristic Curve). Results There were 226 coronary artery calcifications in the cohort and SUVmax was $1.15{\pm}0.39$. Of the 28 patients (62%), 58 were classified as high risk (TBR > 1.25). The remaining 168 were $TBR{\leq}1.25$. Conclusion $^{18}F-NaF$ PET images were available for quantitative assessment of microcalcifications and could be classified into high-risk groups. The combination of angiographic CT and $^{18}F-NaF$ PET may be a new method for early diagnosis of high-risk microcalcifications.

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.

Effect of Transportation Temperature and Treatment Time of Ethylene in the Simulated Export on Ripening and Quality of 'Cheongdobansi' Astringent Persimmon (떫은감 '청도반시' 모의 수출에서 수송 온도와 에틸렌 발생제 투입시기가 과실의 숙성 및 품질에 미치는 영향)

  • Kim, Ji-Young;Kim, Il-Ho;Nam, Hyun-Jin;Park, Young-Hoon;Kang, Jum-Soon;Choi, Young-Whan;Son, Beung-Gu;Lee, Yong-Jae
    • Journal of agriculture & life science
    • /
    • v.51 no.4
    • /
    • pp.79-86
    • /
    • 2017
  • We performed simulations of shipping conditions to export 'Cheongdobansi' astringent persimmon to tropical regions. We stored the fruits at $0^{\circ}C$, $5^{\circ}C$, or $10^{\circ}C$ temperature for 15 days to simulate the transport conditions, and then maintained the fruits at $30^{\circ}C$ for 5 days to simulate the distribution condition. Variables that we focused on are 1) the transport temperature($0^{\circ}C$, $5^{\circ}C$, or $10^{\circ}C$) and 2) the treatment time of ethylene generator(before or after shipping). We examined the ripening ratio and quality of the fruits at the end of the shipping and at that of the distribution. The examination at the end of the shipping showed that all of the fruits were ripened at $10^{\circ}C$ transportation but not ripened at $0^{\circ}C$ or $5^{\circ}C$ transportation in the ethylene treated condition. The untreated fruits were not ripened regardless of the transportation temperature. The examination at the end of the distribution showed that all of the fruits were ripened at $5^{\circ}C$ and $10^{\circ}C$ transportation, while 38.5% of fruits were ripened at $0^{\circ}C$ transportation in the ethylene treated fruits before shipping. The fruits treated after shipping were 63.5% and 59.6% ripened at $0^{\circ}C$ and $5^{\circ}C$ transportation, respectively. Unexpectively, only 19.2 % of fruits treated after shipping ripened at $10^{\circ}C$ transportation.

Atmospheric Vertical Structure of Heavy Rainfall System during the 2010 Summer Intensive Observation Period over Seoul Metropolitan Area (2010년 여름철 수도권 집중관측기간에 나타난 호우 시스템의 대기연직구조)

  • Kim, Do-Woo;Kim, Yeon-Hee;Kim, Ki-Hoon;Shin, Seung-Sook;Kim, Dong-Kyun;Hwang, Yoon-Jeong;Park, Jong-Im;Choi, Da-Young;Lee, Yong-Hee
    • Journal of the Korean earth science society
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2012
  • The intensive observation (ProbeX-2010) with 6-hour launches of radiosonde was performed over Seoul metropolitan area (Dongducheon, Incheon Airport, and Yangpyeong) from 13 Aug. to 3 Sep. 2010. Five typical heavy rainfall patterns occurred consecutively which are squall line, stationary front, remote tropical cyclone (TC), tropical depression, and typhoon patterns. On 15 Aug. 03 KST, when squall line developed over Seoul metropolitan area, dry mid-level air was drawn over warm and moist low-level air, inducing strong convective instability. From 23 to 26 Aug and from 27 to 29 Aug. Rainfall event occurred influenced by stationary front and remote TC, respectively. During the stationary frontal rainy period, thermal instability was dominant in the beginning stage, but dynamic instability became strong in the latter stage. Especially, heavy rainfall occurred on 25 Aug. when southerly low level jet formed over the Yellow Sea. During the rainy period by the remote TC, thermal and dynamic instability sustained together. Especially, heavy rainfall event occurred on 29 Aug. when the tropical air with high equivalent potential temperature (>345 K) occupied the deep low-middle level. On 27 Aug. and 2 Sep. tropical depression and typhoon Kompasu affected Seoul metropolitan area, respectively. During these events, dynamic instability was very strong.

Growth Characteristics of Sprouts and Changes of Antioxidant Activities in Common Bean (Phaseolus vulgaris L.) with Cultivated Temperature (재배온도에 따른 강낭콩 싹나물의 재배특성 및 항산화 활성)

  • Kim, Hyun-Young;Koo, Sung-Cheol;Kang, Beom-Kyu;Lee, Yeong-Hoon;Kim, Hyun-Tae;Yun, Hong-Tae;Baek, In-Youl;Jeong, Heon-Sang;Choi, Man-Soo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.2
    • /
    • pp.201-207
    • /
    • 2014
  • The changes of growth characteristics and antioxidant activity for selection of optimum germinated temperature on common bean (Phaseolus vulgaris L.). Common beans (IT100888, IT102849, and IT231267) were cultivated at $20^{\circ}C$, $23^{\circ}C$ and $25^{\circ}C$ during 5 days of germination. The range of whole length, hypocotyls length, thickness, abnormal germination and yield rate of sprouts was 7.27~27.62 cm, 3.10~18.86 cm, 1.80~2.27 mm, 5.54~18.34% and 205.95~ 618.71%, respectively. Antioxidant activities of common beans with germination temperature investigated. Common beans (IT100888, IT102849, and IT231267) germinated at $20^{\circ}C$, $23^{\circ}C$ and $25^{\circ}C$ during 5 days, and then extracted with 80% ethanol, and analyzed for total polyphenol content, DPPH and ABTS radical scavenging activity. Total polyphenol content increased from 474 mg GA eq/100 g sample for IT231267 to 1364 mg GA eq/g sample for $23^{\circ}C$ of germination. DPPH radical scavenging activity of IT102849 increased from 189mg Trolox eq./100 g sample ($20^{\circ}C$) to 1073mg Trolox eq./100 g sample ($23^{\circ}C$) also ABTS radical scavenging activity of IT234267 increased from 479 mg Trolox eq./100 g sample ($20^{\circ}C$) to 1134 mg AA eq/100 g ($23^{\circ}C$). These results suggest that germination temperature for increasing antioxidant activities may be $23^{\circ}C$.

Research of Heavily Selective Emitter Doping for Making Solar Cell by Using the New Atmospheric Plasma Jet (새로운 대기압 플라즈마 제트를 이용한 태양전지용 고농도 선택적 도핑에 관한 연구)

  • Cho, I Hyun;Yun, Myung Soo;Son, Chan Hee;Jo, Tae Hoon;Kim, Dong Hea;Seo, Il Won;Rho, Jun Hyoung;Jeon, Bu Il;Kim, In Tae;Choi, Eun Ha;Cho, Guangsup;Kwon, Gi Chung
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.238-244
    • /
    • 2013
  • Doping process using laser is an important process in fabrication of solar cell for heat treatment. However, the process of using the furnace is difficult to form a selective emitter doping region. The case of using a selective emitter laser doping is required an expensive laser equipment and induce the wafer's structure damage due to high temperature. This study, we fabricated a new costly plasma source. Through this, we research the selective emitter doping. We fabricated that the atmospheric pressure plasma jet injected Ar gas is inputted a low frequency (a few tens kHz). We used shallow doping wafers existing PSG (Phosphorus Silicate Glass) on the shallow doping CZ P-type wafer. Atmospheric plasma treatment time was 15 s and 30 s, and current for making the plasma is 40 mA and 70 mA. We investigated a doping profile by using SIMS (Secondary Ion Mass Spectroscopy) and we grasp the sheet resistance of electrical character by using doping profile. As result of experiment, prolonged doping process time and highly plasma current occur a deeper doping depth, moreover improve sheet resistance. We grasped the wafer's surface damage after atmospheric pressure plasma doping by using SEM (Scanning Electron Microscopy). We check that wafer's surface is not changed after plasma doping and atmospheric pressure doping width is broaden by increase of plasma treatment time and current.

A Study on Detailed Bathymetry and Geophysical Characteristics of the Summit of the Dokdo Volcano (독도 화산체 정상부해역의 정밀해저지형 및 지구물리학적 특성 연구)

  • Kim, Chang Hwan;Park, Chan Hong;Lee, Myoung Hoon;Choi, Soon Young;Jou, Hyeong Tae
    • Economic and Environmental Geology
    • /
    • v.45 no.6
    • /
    • pp.685-695
    • /
    • 2012
  • We studied the detailed bathymetry and the geophysical characteristics of the summit of the Dokdo volcano using mutibeam echosounding and geophysical survey data. The bathymetry around the main east and west islets of the Dokdo volcano shows very shallow within about 10 m water depth. From near islets to about 30 m b.s.l., the shallow water area has very steep slope and many irregular sunken rocks. The area from about 30 m to about 80 m b.s.l. shows gentle rises and falls, and less steep slope. The area from 80 m b.s.l. has gradually flat undulation and smooth slope seabaed and is extended to offshore. The main islets of the Dokdo volcano and the rocky sea bottom elongated from the islets might be the residual part of the eroded and collapsed main crater of the Dokdo volcano. The bathymetry and the seafloor image(from backscattering) data show small craters, assumed to be formed by the eruption of later volcanism. The seafloor images propose that, except some areas with shallow sand sedimentary deposits, there are typical rocky bottom such as rocky protrusions and lack of sediments in the main morphology of the survey area. The stepped slopes of the seabed are deduced to be submarine terraces. The several prominent submarine terraces are found at the summit of the Dokdo volcano, suggesting repetition of sea level changes(transgressions and regressions) in the Quaternary. The results of the magnetic anomaly and the analytic signal have a good coherence with other geophysical consequences regarding to the location of the residual crater.

Four-Channel Differential CMOS Optical Transimpedance Amplifier Arrays for Panoramic Scan LADAR Systems (파노라믹 스캔 라이다 시스템용 4-채널 차동 CMOS 광트랜스 임피던스 증폭기 어레이)

  • Kim, Sang Gyun;Jung, Seung Hwan;Kim, Seung Hoon;Ying, Xiao;Choi, Hanbyul;Hong, Chaerin;Lee, Kyungmin;Eo, Yun Seong;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.82-90
    • /
    • 2014
  • In this paper, a couple of 4-channel differential transimpedance amplifier arrays are realized in a standard 0.18um CMOS technology for the applications of linear LADAR(laser detection and ranging) systems. Each array targets 1.25-Gb/s operations, where the current-mode chip consists of current-mirror input stage, a single-to-differential amplifier, and an output buffer. The input stage exploits the local feedback current-mirror configuration for low input resistance and low noise characteristics. Measurements demonstrate that each channel achieves $69-dB{\Omega}$ transimpedance gain, 2.2-GHz bandwidth, 21.5-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -20.5-dBm), and the 4-channel total power dissipation of 147.6-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations. Meanwhile, the voltage-mode chip consists of inverter input stage for low noise characteristics, a single-to-differential amplifier, and an output buffer. Test chips reveal that each channel achieves $73-dB{\Omega}$ transimpedance gain, 1.1-GHz bandwidth, 13.2-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -22.8-dBm), and the 4-channel total power dissipation of 138.4-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations.

Changes of the Preoperative and Postoperative Nutritional Statuses in Patients with Gastric Cancer and Assessment of the Nutritional Factors That Are Correlated with Short-Term Postoperative Complications (위암 환자에서 수술 전후의 영양지표의 변화와 수술 후 단기간 합병증과의 연관성)

  • Oh, Cheong-Ah;Kim, Dae-Hoon;Oh, Seung-Jong;Choi, Min-Gew;Noh, Jae-Hyung;Sohn, Tae-Sung;Kim, Sung;Bae, Jae-Moon
    • Journal of Gastric Cancer
    • /
    • v.10 no.1
    • /
    • pp.5-12
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the preoperative and postoperative nutritional statuses of patients with gastric cancer and to investigate the nutritional factors that are correlated with perioperative complications. Materials and Methods: From January 2008 to Jun 2008, 669 patients who underwent curative gastrectomy were enrolled in a retrospective study. To evaluate the changes of their nutritional status preoperatively and postoperatively, we measured the total lymphocyte count, the serum albumin, the body weight change and the BMI. The nutritional factors correlated with short-term postoperative complications were analyzed. Results: The total lymphocyte count and serum albumin decreased from the first preoperative day to the $5^{th}$ day after operation, but they tended to increase and approach the normal range 6 months after operation. The only factor correlated with the short-term postoperative complications (defined as the ones that occurred for 30 days) was the serum albumin checked on the $5^{th}$ day after operation. Conclusion: Low serum albumin on the $5^{th}$ day after operation was correlated with postoperative short-term complications. Serum albumin can be the preoperative statistical parameter that can predict the occurrence of postoperative complications.

Experimental Study on Autothermal Reformation of Methanol with Various Oxygen to Methanol Ratios for Fuel Cell Applications (연료전지용 메탄올 자열 개질기의 산소-메탄올 비율에 따른 성능 실험)

  • Hwang, Ha-Na;Shin, Gi-Soo;Jang, Sang-Hoon;Choi, Kap-Seung;Kim, Hyung-Man
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.391-397
    • /
    • 2011
  • The use of Hydrogen as a fuel is receiving considerable attention and as a result, research on novel methods of hydrogen production is necessary so that the hydrogen demands in the future can be satisfied. This study presents experimental data on methanol Autothermal Reformation that quantifies the relationship between the oxygen-to-methanol ratio ($O_2/CH_3OH$) and reformer efficiency. For each catalyst configuration, the $O_2/CH_3OH$ was varied from 0.1 to 0.4, with an increment of 0.05, to investigate the effects of $O_2/CH_3OH$ on the reactor performance, including temperature profile, conversion, and efficiency. $O_2/CH_3OH$ was increased from 0.15 to 0.20, and the catalyst bed temperature increased by $235^{\circ}C$ to approximately $550^{\circ}C$. The catalyst bed temperature increased with increasing $O_2/CH_3OH$ as the reaction shifted from endothermic to exothermic reaction and as a result, excess heat, which raised the reactor temperature, was generated. The reactor performance was shown to be highly dependent on $O_2/CH_3OH$. The optimum $O_2/CH_3OH$ = 0.30 found in the experimental tests is 30% higher than the theoretical optimum of 0.23. This is attributed to a combination of factors such as the concentrations of the $O_2$ and $CH_3OH$ gas, reaction rate, catalyst effects, heat loss from the reactor, and the difference between the actual amounts of reaction products formed and the theoretical amounts of the reaction products.