• Title/Summary/Keyword: Chlorine gas

Search Result 214, Processing Time 0.025 seconds

Quality Attributes of Fresh-Cut Green Onion as Affected by Rinsing and Packaging (절단 대파의 품질특성에 미치는 세척 및 포장재의 효과)

  • Hong, Seok-In;Jo, Mi-Na;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.659-667
    • /
    • 2000
  • Quality attributes of fresh-cut green onion(Allium fistulosum L.) as affected by rinsing and packaging were investigated in terms of flesh weight, color, viable cell counts, sensory properties during storage at $10^{\circ}C$. Fresh green onions were trimmed, cut, and rinsed with cold water(approximately $5^{\circ}C$) as well as chlorine solution(100 mg/L) and then packaged in low density polyethylene film pouches of $63\;{\mu}m$ thickness. Rinsing treatments with cold water or chlorine solution did not significantly influence changes in microbial populations but sensory characteristics, resulting in cut green onions of better visual quality as compared to the control without rinsing. Fresh-cut green onions were also rinsed with cold water and packaged in sealed bags of low density polyethylene films with different thickness(22, 36, $63\;{\mu}m$), and stored at $10^{\circ}C$ for 18 days. Thickness of polyethylene film was a significant factor for microorganisms populations and sensory attributes. Mesophilic aerobic bacterial count after 13 days for the control, packed in punched film bags, was $3.07{\times}10^6}$ CFU/g, while those for samples in hermetically sealed bags ranged only $1.74{\sim}2.02{\times}10^5}$ CFU/g. Gas composition within the sealed packages changed from normal air to about $1.3{\sim}5.4%\;O_2$ and $4.0{\sim}8.0%\;CO_2$ after 13 days of storage. Particularly, the visual sensory quality of cut green onion samples was retained better in polyethylene film bags of $63\;{\mu}m$ thickness(gas transmission rate: 600 $O_2\;mL/day{\cdot}m^2{\cdot}atm;\;2,500\;CO_2\;mL/day{\cdot}m^2{\cdot}atm$) than in the others.

  • PDF

Effect of Barley Tea on the Reduction of the Tap Water Chlorination By-Products in Top Water and Identification of Maillard Reaction Products in the Extracts of Barley Tea, Corn Tea, and Cassia tora Seed Tea Using GC/MSD (보리차 제조시 수돗물 중 염소소독부산물의 제거 여부 및 보리차.옥수수차.결명차 중 Maillard 반응 생성물 동정)

  • Lee, Soo-Hyung;Kim, He-Kap
    • Applied Biological Chemistry
    • /
    • v.42 no.3
    • /
    • pp.256-261
    • /
    • 1999
  • This study was conducted to investigate the effect of barley tea with roasted grains and barley tea with a tea bag on the reduction of chlorination by-product(CBP) levels in chlorinated drinking water. Since the concentrations of six volatile compounds of eight CBPs were blow their respective detection limits after 10 minute heating, two nonvolatile CBPs dichloroacetic acid and trichloroacetic acid, and total chlorine were compared between tap water and two kinds of barley tea. No significant differences were observed in the relative changes of the amounts of the above three items, and new peaks which were not found in the original water appeared in the chromatograms of gas chromatograph/electron capture detector(GC/ECD). Thirty three organic compounds were identified in the extracts of barley tea with roasted grains, barley tea with a tea bag, corn tea, and Cassia tora seed tea which were prepared with distilled/deionized water, using gas chromatography/mass selective detection(GC/MSD). Exclusive of fatty acids, most of the compounds were aromatic compounds such as phenols, furans, and pyrroles.

  • PDF

Metal Corrosion Mechanism by Sulfate-reducing and Iron-oxidizing Bacteria in Saline System and its Optimal Inactivation (염수계 철산화균 및 황환원균에 의한 금속 부식 및 최적 제어 방안)

  • Sung, Eun-Hae;Han, Ji-Sun;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.798-807
    • /
    • 2008
  • Due to economic impairment derived from metal corrosion of pumping station installed around coastal area, it was needed for related cause-effect to be investigated for understanding practical corrosion behavior and providing proper control. This research was thus carried out to determine whether the microbe can influence on metal corrosion along with its control in the laboratory. For this study, groundwater was sampled from the underground pump station(i.e. I Gas Station) where corrosion was observed. Microbial diversity on the samples were then obtained by 16S rDNA methods. From this, microbial populations showing corrosion behaviors against metals were reported as Leptothrix sp.(Iron oxidizing) and Desulfovibrio sp.(Sulfur reducing) Iron oxidizing bacteria were dominantly participating in the corrosion of iron, while sulfate reducing bacteria were more preferably producing precipitate of iron. In case of galvanized steel and stainless steel, iron oxidizing bacteria not only enhanced the corrosion, but also generated its scale of precipitate. Sulfate reducing bacteria had zinc steel corroded greater extent than that of iron oxidizing bacteria. In the inactivation test, chlorine or UV exposure could efficiently control bacterial growth. However as the inactivation intensity being increased beyond a threshold level, corrosion rate was unlikely escalated due to augmented chemical effect. It is decided that microbial corrosion could be differently taken place depending upon type of microbes or materials, although they were highly correlated. It could be efficiently retarded by given disinfection practices.

Study on Safety Management Plan through Chemical Accident Investigation in PCB Manufacturing Facility Etching Process (PCB 제조시설 에칭공정 화학사고 조사를 통한 안전관리 방안 연구)

  • Park, Choon-Hwa;Kim, Hyun-Sub;Jeon, Byeong-Han;Kim, Duk-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.132-137
    • /
    • 2018
  • Although the number of chemical accidents has been declining since the Chemical Control Act of 2015, there have been repeated occurrences of similar types of accidents at printed circuit board (PCB) manufacturing facilities. These accidents were caused by the overflow of hydrochloric acid and hydrogen peroxide, which are toxic chemicals used in the printed circuit board manufacturing process. An analysis of the $Cl^-$ content to identify the cause of the accident showed that in the mixed route of hydrochloric acid and hydrogen peroxide, which are accidental substances, the $Cl^-$ concentration was 66.85 ppm in the hydrogen peroxide sample. Through reaction experiments, it was confirmed that the deformation of a PVC storage tank and generation of chlorine gas, which is a toxic gas, occurred due to reaction heat occurring up to $50.5^{\circ}C$. This paper proposes a facility safety management plan, including overcharge, overflow prevention, leak detection device, and separation tank design for mixing prevention in printed circuit board manufacturing facility etch process. To prevent the recurrence of accidents of the same type, the necessity of a periodic facility safety inspection and strengthening of the safety education of workers was discussed.

Quality Changes in 'Elliot' Blueberries and 'Sulhyang' Strawberries Packed with Two Different Packaging Materials during Refrigerated Storage (기체투과도가 다른 포장재로 포장한 '엘리오트' 블루베리와 '설향' 딸기의 냉장 저장 중 품질 변화)

  • Jung, Seung Hun;Kang, Ji Hoon;Park, Seung Jong;Seong, Ki Hyun;Song, Kyung Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.6
    • /
    • pp.901-908
    • /
    • 2014
  • Blueberries and strawberries are highly perishable and easily contaminated with microorganisms. To maintain the quality of these commodities during refrigerated storage, the effects of two packaging materials as well as passive modified atmosphere packaging on the quality of blueberries and strawberries were investigated. The harvested blueberries and strawberries were first treated with combined non-thermal treatment of aqueous chlorine dioxide and fumaric acid, followed by packaging with polyolefin film (6,000 mL $O_2/m^2{\cdot}24hr{\cdot}atm$ at $24^{\circ}C$) and polyamide/polyamide/polyethylene film (PA/PA/PE, 60 mL $O_2/m^2{\cdot}24hr{\cdot}atm$ at $24^{\circ}C$), respectively. After combined sanitizer treatment, the populations of total aerobic bacteria in blueberries and strawberries were reduced by 2.50 and 1.97 log CFU/g while those of yeast and molds were reduced by 1.95 and 2.18 log CFU/g, respectively, compared with the control. In particular, microbial growth in these samples packed with PA/PA/PE film was reduced during refrigerated storage. In addition, the blueberries and strawberries packed with PA/PA/PE film underwent lower weight loss than those packed with polyolefin film during storage. These results suggest that appropriate packaging with proper gas permeability is necessary to maintain the quality of blueberries and strawberries during refrigerated storage.

Analysis of Trace Levels of Lodinated Trihalomethanes in Water Using Headspace - GC/ECD (Headspace - GC/ECD를 이용한 수중의 미량 요오드계 트리할로메탄류 분석)

  • Son, Hee-Jong;Song, Mi-Jung;Kim, Kyung-A;Yoom, Hoon-Sik;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Trihalomethanes (THMs) are formed as a results of the reaction of residual chlorine, used as a disinfectant in drinking water, with the organic matter in raw water. Although chlorinated and brominated THMs are the most common disinfection byproducts (DBPs) reported, iodinated THMs (I-THMs) can be formed when iodide is present in raw water. I-THMs have been usually associated with several medicinal or pharmaceutical taste and odor problems and is a potential health concern since they have been reported to be more toxic than their brominated and chlorinated analogs. Currently, there is no published standard analytical method for I-THMs in water. An automated headspace-gas chromatography/electron capture detector (GC/ECD) technique was developed for routine analysis of 10 THMs including 6 I-THMs in water samples. The optimization of the method is discussed. The limits of detection (LOD) and limits of quantification (LOQ) range from 12 ng/L to 56 ng/L and from 38 ng/L to 178 ng/L for 10 THMs, respectively. Matrix effects in river water, sea water and wastewater treatment plant (WWTP) final effluent water were investigated and it was shown that the method is suitable for the analysis of trace levels of I-THMs, in a wide range of waters. The method developed in the present study has the advantage of being rapid, simple and sensitive.

Application of Microwave-HClO Leaching for On-board Recovery of Au in Hydrothermal Minerals (열수광물내 Au의 선상회수를 위한 마이크로웨이브-차아염소산 용출 적용성)

  • Kim, Hyun Soo;Myung, Eun Ji;Kim, Min Sung;Lee, Sung-Jae;Park, Cheon-young
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.3
    • /
    • pp.243-250
    • /
    • 2020
  • The purpose of this study is to find out the possibility of applying microwave-hypochlorous acid leaching to effectively leaching Au in hydrothermal minerals on board. The comparative leaching experiment were confirmed that the leaching rate of Au with(T1)/with out(T2) of microwave nitric acid leaching. In addition, the leaching rate of Au on the conventional leaching by mechanical agitation(T3) and microwave leaching was compared. The result of microwave nitric acid leaching(solid-liquid ratio; 10%, leaching temperature; 90 ℃, leaching time; 20 min) confined that the metal leaching rate was high in the order of As>Pb>Cu>Fe>Zn, and the content of Au in the leaching residue was increased from 33.77 g/ton to 60.02 g/ton. As a result of the comparative leaching experiment using a chloride solvent, the dissolution rate of Au was high in the order of T1(61.10%)>T3(53.30%)>T2(17.30%). Therefore, chloride, which can be manufactured using seawater and that can be recycled by collecting chlorine gas generated in the leaching process, is expected to be an optimal solvent for Au leaching. In addition, the application of microwaves is believed to be effective in terms of time, efficiency and energy.

Preparation of Titanyl Chlorde (鹽化티타닐 製造에 關한 硏究)

  • Chyun, Byong-Doo;Shin, Yoon-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.4 no.1
    • /
    • pp.15-17
    • /
    • 1957
  • 1. Preparation of Titanium tetrachloride; The following precesses were strictly followed as the preliminary step to obtain pure $TiOCl_2$, titanyl chloride; First, pure Titanium Oxide mixed with carbon is rolled into pills. After drying up perfectly, these pills are heated at 900∼1000${\circ}C$. And then the pills are subjected to the flow of $Cl_2$ gas in a quartz tube heated to 900-1000${\circ}C$. Thus Titanium tetrachloride is obtained. 2. Preparation of $TiOCl_2$ ; Yellowish trobrown solution is made by pouring 80 g of conc. HCl (sp.gr. 1.19) to 45 gr of Titanium tetrachloride (approx. 2 times of theoretical amount). Then this solution is kept settled for 5-days in a desiccator filled with phosphorous pentoxide at room temperature. As the colorless amorphous solid thus obtained is washed with aceton, 36.5 g of the pure salt are obtained. 3. Determination of composition. The analysis of the sample taken from the deposit desiccated gives the following data; (A) Qualitative analysis; a) $Ti(OH)_4$ is precipitated by adding NaOH in water solution of the salt. b) Adding $AgNO_3$ solution, the water solution of the salt gives white precipitate of AgCl. c) When acid and $H_2O_2$ are added, the solution turns its color to redish brown (This proves that $TiO^{++}$ was converted into $TiO^{++}$ by oxidation of $H_2O_2$. (B) Quantitative analysis; a) $Ti(OH)_4$ precipitated by $10{\%}$ NaOH isalitatsubjected consecutively to the filtration and ignition in porcelain crucible at approx. 1000${\circ}C$. , then $TiO_2$ thus formed is weighed and calculated into Ti content. b) Chlorine involved in water solution of the salt is determined by Vorhardt method. Result: The values obtained from previous analysis, devied by their atomic weight gives the following composition: Ti : Cl = 1 : 2 Therefore $TiOCl_2$ should be given as its molecular formula. 4. Summary. When $TiCl_4$ is additated into conc. HCl, $TiO^{++}$ formed exists as a stable form, and forms $TiOCl_2$. However $TiOCl_2$ is unstable to heating. When the temperature is raised to $65{\circ}C$the decomposition of the solution is accelerated, and gives $TiO_2$ aq. $TiOCl_2$ in addition is highly hygroscopic.

  • PDF

Quality changes of fresh-cut winter squash treated with different postharvest ripening periods and packaging methods (신선편이 단호박 원료의 후숙기간 및 가공 후 포장방법에 따른 저장 중 품질변화)

  • Kim, Ji-Gang;Choi, Ji-Woen;Cho, Mi-Ae
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • This study was conducted in order to evaluate the effect of postharvest ripening periods and packaging methods on maintaining the quality of fresh-cut winter squash. Winter squash (var. Bouchang) was ripened at $22^{\circ}C$ for 1 or 2 weeks after harvest. The samples were washed in tap water, sanitized in $100{\mu}L/L$ chlorine water, peeled, and cut into 16 parts. Samples were then vacuum packaged or non-vacuum packaged in $80{\mu}m$ nylon/polyethylene (Ny/PE) films and stored at $5^{\circ}C$ for 21 days. Results indicated that different postharvest ripening periods affected gas concentration, firmness, off-odor development, color, and overall quality of fresh-cut winter squash. Samples treated with 2-week ripening periods maintained quality with higher redness value and soluble solid content (SSC) and lower $CO_2$ concentration and off-odor development compared to samples treated with a 1-week ripening period. Non vacuum packaging was effective in increasing visual quality and reducing off-odor development. A combination treatment of 2-week ripening periods and non-vacuum packaging maintained good quality with the lowest off-odor development and the highest visual quality scores at the end of the storage period.

Composite Oxidizing Agents Generation Using Electrolysis of Dilute Hydrochloric Acid (묽은 산 전기분해에 의한 복합 산화제 생성)

  • Kang, Shin-Young;Park, Jong-Hun;Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.329-333
    • /
    • 2016
  • Disinfection by electrolysis would be useful for small wastewater treatment plant, combined sewer overflow, ballast water, swimming pool, and fish farming, where the transport, storage, and the use of chlorine gas is limited. This study investigated the feasibility of the electrolysis of dilute hydrochloric acid (HCl) for disinfection. The effects of HCl concentration, voltage and reaction time on the generation of oxidizing agents, HOCl, $O_3$, and $H_2O_2$, were examined in a series of batch test. The highest current efficiency was 99.3% which was found at 2.2%, 3 V, and 5 min of HCl concentration, voltage, and reaction time, respectively. Continuous electrolysis at 2.2% HCl, 3 V, and 5 min of the hydraulic retention time showed 97.4% of the current efficiency. Addition of sodium chloride up to 20 g/L linearly increased the oxidizing agents production. 92.2% of total coliforms were removed by the contact with the electrolyzed water.