• Title/Summary/Keyword: Chlorine Control

Search Result 230, Processing Time 0.027 seconds

Treatment of Secondary Municipal Wastewater by Submerged Hollow Fiber MF Membranes for Water Reuse (침지형 MF 중공사막을 이용한 하수 2차 처리수의 재이용 연구)

  • Hyun, Seunghoon;Kim, Eung Do;Hong, Seungkwan;Ahn, Wonyoung;Yim, Seongkeun;Kim, Geontae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • This study was conducted to evaluate the performance of submerged hollow fiber MF processes to treat secondary wastewater for water reuse. Specifically, membrane productivity and filtrate water quality were investigated under various operating conditions (i.e. flux, recovery, and backwash rate) at pilot-scale. Membrane fouling became more severe with increasing flux and recovery, suggesting that low flux operation (< 25 LMH) was desirable. At high flux operating(> 37.5 LMH), increasing backwash rate showed only limited success. The biofouling, quantified by PEPA and BFHPC, was also significant in wastewater reclamation, and biogrowth control by chlorine, were necessary to improve membrane productivity. Filtrate water qualities are in good compliance with water reuse regulations regardless of operating conditions (flux, recovery and backwash rate). Particle (e.g. turbidity) removal ranged from 89 to 98%, while only 11 to 21% of organics (e.g. NPDOC) were removed by MF membrane. Only small improvement in biostability (e.g. AOC) was achieved by MF system, and thus, without post disinfection, significant microorganisms might be present in the filtrate due to regrowth. Lastly, in order to further investigate pathogen removal, controlled microbial challenge tests were performed by monitoring Giardia, Cryptosporidium, bacteria and virus, and showed relatively good microbial removal.

The Antibiotic Resistant Gene Pollutant Controls using Chlorine or Ozone disinfection (염소 또는 오존을 이용한 항생제 내성 유전오염물질 제어)

  • Kim, Sung-Pyo;Rhu, Dae-Whan;Oh, Jun-Sik;Cho, Yun-Chul
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.697-705
    • /
    • 2011
  • The aim of this study was to examine ozonation disinfection efficiency for Escherichia coli DH5alpha removal, containing the multi-resistance plasmid pB10 as well as chlorination disinfection efficiency. In addition, plasmid pB10 removal rates were estimated by ozonation and chlorination. The removal efficiency of pB10 via ozonation was about 2 to 4 times higher than chlorination. High removal efficiency of pB10 is likely due to OH radical produced during ozonation. These results suggest that integration of advanced oxidation process such as ozonation (or photocatalytic oxidation) with conventional disinfection such as chlorination may be needed for effective control of antibiotic resistant bacteria and genetic materials.

Fates and Removals of Micropollutants in Drinking Water Treatment (정수처리 과정에서의 미량오염물질의 거동 및 제거 특성)

  • Nam, Seung-Woo;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.391-407
    • /
    • 2013
  • Micropollutants emerge in surface water through untreated discharge from sewage and wastewater treatment plants (STPs and WWTPs). Most micropollutants resist the conventional systems in place at water treatment plants (WTPs) and survive the production of tap water. In particular, pharmaceuticals and endocrine disruptors (ECDs) are micropollutants frequently detected in drinking water. In this review, we summarized the distribution of micropollutants at WTPs and also scrutinized the effectiveness and mechanisms for their removal at each stage of drinking water production. Micropollutants demonstrated clear concentrations in the final effluents of WTPs. Although chronic exposure to micropollutants in drinking water has unclear adverse effects on humans, peer reviews have argued that continuous accumulation in water environments and inappropriate removal at WTPs has the potential to eventually affect human health. Among the available removal mechanisms for micropollutants at WTPs, coagulation alone is unlikely to eliminate the pollutants, but ionized compounds can be adsorbed to natural particles (e.g. clay and colloidal particles) and metal salts in coagulants. Hydrophobicities of micropollutants are a critical factor in adsorption removal using activated carbon. Disinfection can reduce contaminants through oxidation by disinfectants (e.g. ozone, chlorine and ultraviolet light), but unidentified toxic byproducts may result from such treatments. Overall, the persistence of micropollutants in a treatment system is based on the physico-chemical properties of chemicals and the operating conditions of the processes involved. Therefore, monitoring of WTPs and effective elimination process studies for pharmaceuticals and ECDs are required to control micropollutant contamination of drinking water.

Blood Components of Diabetes and the Effect of 1,25-Dehydroxycholecalciferol on Serum Calcium Level (당뇨병 환자의 혈액성분 고찰 및 혈중-Ca 농도에 대한 1,25-Dehydroxycholecalciferol의 급여 효과)

  • Park, M.A.;Lim, S.J.;Yu, J.Y.
    • Journal of Nutrition and Health
    • /
    • v.17 no.4
    • /
    • pp.273-280
    • /
    • 1984
  • The blood components of diabetic patients who visited S- hospital in seoul from January 1982 to June 1983 were compared with the reference levels. Hemoglobin and hematocrit levels of diabetic patients were significantly lower than the reference. The diabetic patients showed 2-3 times higher levels of fasting blood glucose and postprandial -2 hours blood sugar. Levels of blood urine nitrogen and creatine were also significantly higher in the diabetes mellitus and the levels of potassium sodium and chlorine showed no differences although these were decreased gradually in older patients. Lower serum calcium levels were seen in the diabetic patients and this change was more significant at the ages higher than 40. The effect of an active vitamin D on serum-Ca level in diabetic patients was studied in comparison to that of non- diabetic persons. The serum calcium levels were slightly increased in control and insulin- dependent diabetic patients after a week- intake of 1,000mg calcium a day, while the intake of 1,25-dihydroxycholecalciferol ( 1,000 IU per day ) did not increase the serum calcium levels of these groups. Insulin - independent diabetic patients showed the rather lower serum calcium levels after a week- intake of 1,000mg calcium per day. However, the levels were increased after 2-weeks intake of the calcium and a week-in-take of the active vitamin D(1,000 IU/day ). This effect of vitamin D was seen in the groups with lower intake of calcium(500mg/day ) but not in the groups with 1,000mg calcium intake a day.

  • PDF

Peroxone ($O_3/H_2O_2$) Process in Drinking Water Treatment (정수처리에서의 Peroxone ($O_3/H_2O_2$) 공정)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Bin, Jae-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.296-308
    • /
    • 2010
  • The peroxone process overcomes many of the limitations associated with conventional and advanced water treatment systems using chlorine disinfection and ozone oxidation processes. Ozone and hydrogen peroxide generate highly reactive hydroxyl free radical which oxidize various organic compounds and has highly removal efficiency. The key issue to operate peroxone process is developing the method to achieve high process effectiveness when scavengers that inhibit generation of OH radicals or consume OH radicals are co-existing in the process. Also many studies, to minimize inorganic oxidative by-products such as bromate and to reduce disinfection by-products after chlorination behind peroxone process, are needed. And we should consider the excess residual hydrogen peroxide in the water. On-line instruments and control strategies need to be developed to ensure effective and robust operation under conditions of varying load. If problems above mentioned are solved, peroxone process will be applied diversely for water treatment.

Growth Response in Hydroponic Cultured Dracaena braunii Grown under Various Chloride Ion Concentrations (수경재배에서 제설제 염소이온 농도에 따른 개운죽 (Dracaena braunii)의 생육반응)

  • Son, Hye-Mi;Park, Ju-Young;Yoon, Young-Han;Ju, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1081-1086
    • /
    • 2017
  • The present study was conducted for the purpose of analyzing the growth response of Dracaena braunii treated with chloride ions and to evaluate its salt tolerance. Distilled water (CON) was spiked with 1 (C1), 2 (C2), 5 (C5), 10 (C10) and 15 g/L (C15) $CaCl_2$, respectively. Acidity (pH) and electrical conductivity of hydroponic solution, and leaf width, leaf length, root length, number of leaves, fresh weight, dry weight and the water content of Dracaena braunii were measured. Acidity and electrical conductivity remarkably increased commensurate with increasing concentrations of $CaCl_2$. Growth in the C1 treatment was better than that in CON, whereas the C10 or C15 treatments caused either slow growth or withering of the plants. Fresh weight, dry weight and water content were significantly decreased in response to $CaCl_2$ concentration, compared with those in the control. These results showed that $CaCl_2$ concentration less than 1 g/L may be used as a hydroponic solution for D. braunii, as long as the water quality is not too saline. The chlorine ion has a negative effect on the growth.

Improvement of Water Treatment Efficiency by pH Decreasing Agent (H2SO4) for Droughty Seasons (갈수기 정수장운영관리 사례 - 갈수기 pH저감제(황산)투입에 의한 정수처리효율 향상)

  • Ka, Gilhyun;Kim, Yunyung;Lee, Junho;Ahn, Chihwa;Han, Ihnsup;Min, Byungdae
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • Drinking water treatment is enhanced by coagulant dosages and chlorine injection because of pH increase in raw water in droughty seasons such as spring and fall. But water quality deterioration is occurred by increase in residual aluminium and disinfection by-products. Coagulation process can be used to control natural organic matter (NOM) during water treatment. The effect of coagulation process appeared to depend on the pH of water rather than coagulant dosages. In this study, for water treatment in high pH season $H_2SO_4$ was applied for pH adjustment at full scale. Before and after pH adjustment by $H_2SO_4$ injection, water quality of drinking water was evaluate. In the result of investigation of total organic carbon (TOC) removal in high pH season, TOC was removed approximately 30~40%, which showed decrease in water treatment efficiency. Also, it is increased both particle numbers and residual Al concentration in the water. After $H_2SO_4$ injection for adjustment to pH<7.5 in settled water, treated water turbidity decreased in 0.047 NTU from 0.059 NTU, and particle numbers of filtered water decreased in 20/mL from 90/mL. On the other side, TOC removal efficiency increased in approximately 10% after adjustment of pH. In the result of decrease in pH in raw water through more coagulants and prechlorine without $H_2SO_4$ injection, trihalomethanes (THMs) concentration increased in $16{\mu}g/L$ from $8{\mu}g/L$.

A Study on the Basic Properties of Concrete and Low Heat-Blended Cement with Bottom Ash (바텀애시를 이용한 저발열 혼합시멘트 및 콘크리트의 기초물성에 관한 연구)

  • Kim, Won-Ki;Kim, Hoon-Sang;Kim, Hong-Joo;Lee, Won-Jun;Shin, Jin-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.685-688
    • /
    • 2008
  • This study has examined the effect of bottom ash(BA) on the properties of low heat-blended cement(LHC) and concrete. A number of binders were prepared by the replacement of LHC with BA in range of 5$^{\sim}$20wt%. The results showed that the final setting time of cement paste were delayed when the BA replaced part of the cement. However, The heat of hydration increased narrowly with adding BA in a early hydration period. The results also showed the inclusion of BA at replacement levels of 5$^{\sim}$10wt% resulted in an increase in compressive strength of the specimens compared with that of the control concrete and improved a resistance of concrete against the sulfate and chlorine ion.

  • PDF

Four-Week Repeated Oral Toxicity Study of Clean Natural in Sprague-Dawley Rats (Clean Natural의 Sprague-Dawley 랫드를 이용한 4주 반복경구투여 독성시험)

  • Kim, Eui-Kyung;Kim, Jun-Young;Lee, Hu-Jang
    • Toxicological Research
    • /
    • v.21 no.3
    • /
    • pp.263-269
    • /
    • 2005
  • This study was performed to investigate repeated-dose toxicities of Clean natural, a new disinfectant, in Sprague-Dawley(SD) rats. In the 4-week repeated oral toxicity study, Clean Natural was orally administered once daily via gavage to male and female rats at dose levels of 0, 500, 1,000 and 2,000 mg/kg body weight for 4-weeks. There were no deaths and clinical signs during the dosing period. In both sexes, there were no statistically significant differences between the administered and control groups in urinalysis indicators and hematological parameters. In serum biochemistry, aspartate aminotransferase(AST) was significantly decreased and sodium content was increased in the 2,000 mg/kg male group, while chlorine was significantly decreased in the 2,000 mg/kg female group. Also, albumin, total cholesterol and total bilirubin were significantly increased in the 2,000 mg/kg male and female group. In histopathological examinations, centrilobular hepatocellular hypertrophy in the liver was observed in the 2,000 mg/kg male and female groups. And pigmentation in the spleen was observed in the 2,000 mg/kg male group. In conclusion, four-week repeated oral dose of Clean Natural to rats did not cause apparent toxicological change at the dose less than 2,000 mg/kg body weight. Thus it is suggested that no-observed adverse-effect level(NOAEL) for Clean Natural in rats was considered to be 1,000 mg/kg/day.

An Experimental Study on the Ion Reaction and the Electrochemical Rebar-Corrosion in Aqueous Solution Mixed with Sulfate and Chloride Ion-Reactive Material (황산, 염소이온 반응 소재 혼입 수용액에서의 이온반응성 및 전기화학적 철근 부식에 관한 실험적 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Kang, Tae-Won;Lim, Chang-Gil;Kim, Hong-Tae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this study, amine derivatives and ion exchange resins were selected to actively control penetration ions ($SO{_4}^{2-}$, $Cl^-$) as the element technology of repair materials for concrete structures in drainage environments. Ions ($SO{_4}^{2-}$, $Cl^-$) adsorption performance and corrosion resistance of calcium hydroxide solution with amine derivative and ion exchange resin were confirmed by ion chromatography and potentiostat analysis. As a result of the experiment, it was confirmed that the amine derivative is excellent in the adsorption of chlorine ion and the ion exchange resin is excellent in the adsorption of sulfate ion. It has been confirmed that corrosion resistance can be increased by proper combination of two materials in the calcium hydroxide solution containing sulfate ion and chloride ion simulating sewage environment.