Experimental Investigation of Chloride Ion Penetration and Reinforcement Corrosion in Reinforced Concrete Member

  • Al Mamun, Md. Abdullah;Islam, Md. Shafiqul
    • Journal of Construction Engineering and Project Management
    • /
    • 제7권1호
    • /
    • pp.26-29
    • /
    • 2017
  • This paper represents the experimental investigation of chloride penetration into plain concretes and reinforced concretes. The main objective of this work is to study the main influencing parameters affecting corrosion of steel in concrete. Plain cement concrete and reinforced cement concrete with different water-cement ratios and different cover depth were subjected to ponding test. Ponding of specimens were done for different periods into 10% NaCl solution. Depth of penetration of chloride solution into specimens was measured after ponding. Specimens were crushed and reinforcements were washed using $HNO_3$ solution and weight loss due to corrosion was calculated accordingly. There was a linear relationship between depth of penetration and water-cement ratio. It was also observed that, corrosion of reinforcing steel increases with chloride ponding period and with water-cement ratio. Corrosion of steel in concrete can be minimized by providing good quality concrete and sufficient concrete cover over the reinforcing bars. Water-cement ratio has to be low enough to slow down the penetration of chloride salts into concrete.

염화물 고정화를 고려한 철근 콘크리트 구조물의 내구수명 예측 (Service Life Prediction of R.C. Structures Considering Chloride Binding)

  • 이창수;박종혁;김영욱
    • 한국방재학회 논문집
    • /
    • 제10권1호
    • /
    • pp.15-22
    • /
    • 2010
  • 자연환경 중 다양한 형태로 존재하는 염화물은 콘크리트 구조물의 철근 부식을 야기하며 이에 따른 심각한 내구성 저하와 함께 구조물의 수명을 감소시킨다. 현재 콘크리트 중의 염화물 침투 특성을 규명하기위한 연구는 해안가 장기 폭로 시험과 전기화학적 촉진 시험에 의한 확산계수 평가 등에 의해 지속적인 발전을 이루어왔으나 콘크리트의 배합, 수화도, 고정화능력, 공극률의 재료적 특성을 고려한 이성적이며 포괄적인 염화물 침투 모델에 관한 연구는 부족한 실정이다. 따라서 본 연구에서는 실내 염화물 침지 실험을 통해 콘크리트의 염화물 고정화 특성을 파악하고 이를 고려한 염화물 침투 모델로서 비정상상태의 염화물 침투 해석과 함께 해양침지환경하의 철근콘크리트 구조물의 내구수명 예측을 시도하였으며 SHRP 기준과 20~40%의 내구수명의 차이를 보였다.

염화물 환경에 있는 에폭시도막철근의 부식 평가 연구 (Corrosion Evaluation of Epoxy-coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests)

  • 박영수;최경민;정시영;김병국;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.254-257
    • /
    • 2006
  • Five bench scale specimens were used to evaluate corrosion performance of damaged epoxy-coated bars in chloride contaminated concrete. The test specimens were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. Test results using linear polarization technique show that the current density of specimen with conventional steel becomes $0.715\;{\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy coated bars are much below $0.1\;{\mu}A/cm^2$ and the bars appears to be in passive condition. The corrosion protection performance provided by calcium nitrite is better than that of specimens with the other two inhibitors.

  • PDF

알콕시 실란계 나노합성 Hybrid 폴리머형 코팅제를 적용한 콘크리트의 내구성능 평가에 관한 실험적 연구 (An Experimental Study on Durability Evaluation of Nano Composite Hybrid Polymer Type Coatings Applied Concrete)

  • 박홍욱;송하원;백종명;우종태;남진원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.687-692
    • /
    • 2003
  • In this study, durability of concrete whose surface were treated by nano-composite hybrid polymer type coatings, which can provide a barrier against the ingress of moisture or aggressive ions to concrete, is discussed. For the durability evaluation of the coated concrete, chloride ponding test, accelerating carbonation test, porosity measurement test, and the SEM test are conducted. As the result of this study, it is found that nano-composite hybrid polymer type coated concrete has a much higher resistance to the ingress of chloride ion, carbon dioxide, moisture and aggressive acid than plain concrete has.

  • PDF

나노합성 무기질 폴리머계 표면처리제를 적용한 콘크리트의 내구성능 평가에 관한 실험적 연구 (An experimental study on durability evaluation of the concrete applied nano level inorganic polymer based coatings)

  • 백종명;김은겸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1014-1020
    • /
    • 2004
  • In this study, durability of the nano-level inorganic polymer based coatings which can provide a barrier against the ingress of moisture or aggressive ions to concrete is discussed. For the durability evaluation of the coatings, chloride penetration test, accelerating carbonation test, freezing and thawing test, and sulfate ponding test are conducted. As the result of this study, concrete applied nano-level inorganic polymer based coatings has a much higher resistance to the ingress of chloride ion, carbon dioxide, moisture and aggressive acid than plain concrete and epoxy resin based paint by means of crosslinking three-dimensional structure with concrete structure.

  • PDF

Corrosion Evaluation of Epoxy-Coated Bars by Electrochemical Impedance Spectroscopy

  • Choi, Oan-Chul;Park, Young-Su;Ryu, Hyung-Yun
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.99-105
    • /
    • 2008
  • Southern exposure test specimens were used to evaluate corrosion performance of epoxy-coated reinforcing bars in chloride contaminated concrete by electrochemical impedance spectroscopy method. The test specimens with conventional bars, epoxy-coated bars and corrosion inhibitors were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. The polarization resistance obtained from the Nyquist plot was the key parameter to characterize the degree of reinforcement corrosion. The impedance spectra of specimens with epoxy-coated bars are mainly governed by the arc of the interfacial film and the resistance against the charge transfer through the coating is an order of magnitude higher than that of the reference steel bars. Test results show good performance of epoxy-coated bars, although the coatings had holes simulating partial damage, and the effectiveness of corrosion-inhibiting additives. The corrosion rate obtained from the impedance spectroscopy method is equivalent to those determined by the linear polarization method for estimating the rate of corrosion of reinforcing steel in concrete structures.

콘크리트 구조물의 염해 내구성능 검토를 위한 현장 품질관리 시험법 검토 (Evaluation of Testing Method for Quality Control of Chloride Diffusivity in Concrete under chloride attack environment)

  • 김홍삼;정해문;안태송;김철호;전병섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.973-976
    • /
    • 2008
  • 염해환경에 건설되는 콘크리트 구조물은 염소이온과 같은 유해이온이 외부로부터 콘크리트 중으로 침투, 확산하여 철근을 부식시킴으로써 구조물의 내구성을 크게 저하시키기 때문에 구조물의 내구성 평가 또는 설계시 중요한 고려사항이 된다. 현재 설계에서 사용되는 확산계수는 각 나라마다 제시된 근거가 다르므로, 직접 비교 검토하는 것이 곤란할 뿐만 아니라 동일 환경조건에서 동일 배합의 콘크리트에 대한 수명예측 결과가 크게 상이한 결과를 초래하게 된다. 본 연구는 염해환경하 콘크리트의 염해 내구성능 품질관리를 적용하기 위해서 현장에서 적용할 수 외국에서 규격화된 시험방법들을 비교 검토하고 이들 시험 방법 가운데 품질관리에 적합한 시험방법을 선정하여 재령별 확산 특성과 침지 시험 결과를 비교하여 분석하였다. 슬래그 미분말을 혼입한 콘크리트의 경우 침지시험(NT Build 443)과 촉진시험(NT Build 492)의 상관성을 분석한다면, 이들 토대로 콘크리트 배합의 품질관리 기준 확산계수를 도출할 수 있을 것으로 판단된다.

  • PDF

Corrosion Evaluation of Epoxy-Coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests

  • Choi, Oan-Chul;Jung, Si-Young;Park, Young-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.3-9
    • /
    • 2006
  • Five slab specimens with predefined cracks are examined to evaluate the corrosion behavior of epoxy-coated bars in chloride contaminated concrete, using linear polarization method. The test specimens were subjected to alternating weekly cycles of ponding in a salt solution and drying for 48 weeks. Test results show that the current density of the specimen of normal steel bars becomes 0.715 ${\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy-coated bars are significantly below 0.1 ${\mu}A/cm^2$ and the bars appears to be in passive condition. The damaged epoxy-coated bars with a corrosion inhibitor of calcium nitrite showed a corrosion rate of 0.110 ${\mu}m/year$ or 56 percents of the corrosion rate of damaged epoxy-coated specimen without such an inhibitor, 0.195 ${\mu}m/year$. However, the corrosion rates of specimens containing the other two corrosion inhibitors, a combination of amines and esters or mixtures of organic alkenyl dicarboxyl acid salts are quite equivalent to the control specimen. The research technique of linear polarization resistance method has proven itself to be useful in measuring corrosion rates of reinforcement in concrete.

포졸란재 함유 콘크리트의 세공구조와 염화물이온 침투 저항성 (Resistance In Chloride ion Penetration and Pore Structure of Concrete Containing Pozzolanic Admixtures)

  • 소양섭;소형석
    • 콘크리트학회논문집
    • /
    • 제14권1호
    • /
    • pp.100-109
    • /
    • 2002
  • 본 연구에서는 콘크리트의 염화물이온 침투 저항성에 미치는 포졸란재의 사용 효과를 평가하고자 물-결합재비와 혼화재의 종류 및 치환율, 양생기간을 변수로 제작된 각 콘크리트에 대해 세공용적, 염화물이온 투과성, 10% 염화나트륨용액 침지실험을 실시하여 보통콘크리트와 비교ㆍ분석하였으며 염화물이온 투과성과 세공구조 및 염화물이온 침투깊이의 상호관계를 검토하였다. 연구결과, 포졸란재의 사용은 콘크리트 내 세공들의 전체용적의 감소보다 모세관공극(50nm이상) 용적의 큰 감소에 더욱 효과적이었으며 이러한 효과로부터 포졸란 함유 콘크리트의 염화물이온 침투 저항성은 동일 배합의 보통콘크리트보다 매우 우수하게 나타났다. 콘크리트의 염화물이온 투과성은 콘크리트의 전세공용적에 관련하고 있지만 상관계수가 낮았으며 오히려 침투 및 확산이 용이한 모세관공극의 용적비(세공경 분포)에 더욱 관련하고 있었으며 침지실험에 의한 염화물이온 침투 깊이와 높은 상관관계를 나타내어 콘크리트의 염화물이온 침투 저항성 평가에 기초자료로서 활용될 수 있을 것으로 판단된다.

강섬유 보강 콘크리트의 수송계수 및 부식저항효과 (Transport Coefficients and Effect of Corrosion Resistance for SFRC)

  • 김병일
    • 콘크리트학회논문집
    • /
    • 제22권6호
    • /
    • pp.867-873
    • /
    • 2010
  • 이 연구에서는 강섬유로 보강된 철근콘크리트에서의 부식 특성에 관한 실험적 연구를 수행하였다. 먼저 강섬유의 보강콘크리트의 수송특성, 즉 공극률, 흡수성, 투과성 및 염소이온 확산성에 관한 실험을 수행하여 철근부식과 의 관계를 비교 평가 하였다. 강섬유의 보강으로 인해 약간의 압축강도 증가와 함께, 흡수성, 투과성 및 확산성에 관한 실험 결과에서도 콘크리트 내부로의 유해물질의 침투저항성이 크게 증가하는 것으로 나타났다. 철근부식과의 관계에서는 예상된 결과와는 다르게 강섬유의 혼입이 철근부식을 가속화 시키는 경향이 나타났다. 염화나트륨 용액이 침투하는 노출면에서는 강섬유의 부식팽창으로 인한 표면박리현상이 관찰되었으며, 철근부위 절단면에서는 철근 주변에 강섬유의 부식이 국부적으로 관찰 되었다. 고온 및 고농도의 염화물 환경에서의 건습 싸이클링이 노출표면에 가까운 공극에서 지속적으로 염분결정체의 증가와 더불어 내부공극에서의 강섬유의 부식으로 증가된 압력이 표면 박리를 일으킨 것으로 보인다. 결과적으로는 노출면 부근에서의 미세균열을 증가가 물, 염화이온 및 산소의 침투를 보강근으로의 가속화를 진행 시킨 것으로 판단이 된다. 이 연구에서는 강섬유로 보강된 철근콘크리트에서 철근부식에 영향을 주는 명확한 메커니즘은 충분히 규명이 되지 않았으며, 보다 명확한 관계를 이해하기 위해서는 부식과정에서 강섬유의 잠재적인 부식팽창에 관한 보다 상세한 실험적 연구가 필요할 것으로 판단되어 진다.