• 제목/요약/키워드: Chloride Ion

검색결과 1,128건 처리시간 0.024초

콘크리트중의 염소이온 확산계수 추정 실험법의 비교 (Comparision of Test Methods for Estimating Chloride Ion Diffusion Coefficient in Concrete)

  • 문한영;김홍삼;문재흠;한아름
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.787-790
    • /
    • 1999
  • To estimate durability of reinforced concrete structures located in or nearby seawater, many different kinds of accelerated tests for evaluation of chloride ion permeation in concrete were proposed. At present the only standardized test is the ASTM C 1202(RCP test). This test method is used to estimate the concrete's resistivity of the chloride penetration in concrete by using the total charges passed and sometimes used to calculate the chloride diffusion coefficients. However, this test may lead to an erroneous chloride diffusion coefficient. So this test method was compared with the modified Dhir's test and the traditional concentration diffusion test. Experimental results showed that the diffusion coefficients determined the RCP test and the PD Index gave wrongous values, but the diffusion coefficient acquired by considering a migration term was nearly the same to the CD Test.

  • PDF

Corrosion of Reinforcement and Its Effect on Structural Performance in Marine Concrete Structures

  • Yokota, Hiroshi;Kato, Ema;Iwanami, Mitsuyasu
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.297-303
    • /
    • 2007
  • This paper discusses the chloride-induced corrosion of reinforcement in marine concrete structures focusing on the variability in the progress of deterioration. Through tests and analyses of reinforced concrete slabs taken out from existing open-pile structures that have been in service for 30 to 40 years, the following topics were particularly discussed: variation in chloride ion profiles of concrete, variation in corrosion properties of reinforcement embedded in concrete, and influence of the reinforcement corrosion on the load-carrying capacity of the concrete slabs. As a result, their variability was found to be very large even in one reinforced concrete slab with almost the same conditions. It was also discussed how to determine the calculation parameters for prediction of decreasing in load-carrying capacity of concrete members with chloride-induced corrosion of reinforcement.

Metanil Yellow에 의한 4급 Amine류의 Ino Pair 추출 흡광도 정량 (II) - Benzalkonium Chloride, Cetylpyridinium Chloride 및 Dimenhydrinate의 정량 (Spectrophotometric Determination of Ion Pair Extraction of Quaternary Amines with Metanil Yellow)

  • 김영수;최종환
    • 약학회지
    • /
    • 제35권1호
    • /
    • pp.15-21
    • /
    • 1991
  • Quaternary amines which are widely used as medicines are nitrogen compounds. Metanil yellow(MY) and benzalkonium chloride(BKC) were mixed and added to 10ml of the buffer solution and then the solution was shaken for 5 minutes. The maximum absorption wavelength of the reaction product was 402 nm. Dichloromethane was the best extracting solvent among the several organic solvents and the most suitable pH range was 2~8. When the BKC-MY calibration curve was made in the best experimental condition, the Lambert-Beer's law was obeyed in the range of BKC concentration of 2$\times$$10^{-6}$~9$\times$$10^{-6}$M by UV spectrophotometer. This method was possible to determine quaternary ammonium salts in the pharmaceutical preparation.

  • PDF

물-시멘트비 및 시멘트 종류가 해양콘크리트의 내염해성에 미치는 영향 (Effect of W/C and the Kinds of Cement on the Chloride Invasion Resistance of the Offshore Concrete)

  • 신홍철;유재강;박상준;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.165-168
    • /
    • 2005
  • This paper investigated the effect of W/C and the kinds of cement on the chloride invasion resistance of the offshore concrete. W/C set up 0.30, 0.35, 0.40 and The kinds of cement were used four(ordinary portland cement, ground granulated blast-furnace slag cement, belite cement, low heat portland cement). For the electrical migration test, NT BUILD 492's method was used to estimate the migration coefficient of chloride ion. As a result, the migration coefficients of chloride ion of concrete according to w/c were shown reducing with the w/c increasing, and according to kinds of cement were shown discrepancy in chloride invasion resistance. Especially blast-furnace slag cement was most low it. In the each cement, the compressive strength was shown related to the migration coefficient.

  • PDF

콘크리트의 배합특성이 염화물 확산계수에 미치는 영향에 관한 연구 (A Study on the Effects of Concrete Mixing Properties on Chloride Diffusion Coefficients)

  • 김도겸;박승범;조광연;이종석;김성욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.747-750
    • /
    • 1999
  • Chloride ions are considered to be the major cause of steel corrosion in concrete structures exposed to seashore environments. Thus, estimating chloride ion concentrations by ages is needed to predict service life of seashore structures. Experimentally measured chloride profiles were used in this study for estimating chloride diffusion coefficients, and a relationship between mixing properties and chloride diffusion coefficients is proposed for predicting chloride penetrations.

  • PDF

THE TRANSFER OF CHLORIDE ION ACROSS ANION EXCHANGE MEMBRANE

  • Yu, Zemu;Wang, Hanming;Wang, Erkang
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.597-601
    • /
    • 1995
  • The transfer of chloride ion across an anion exchange membrane (AEM) was investigated by cyclic voltammetry (CV) and electrochemical impedance spectra. In CV experiment, when the size of the hole in membrane was much smaller than the distance between membrane holes, the Cl anion transfer showed steady state voltammetric behavior. Each hole in membrane can be regarded as a microelectrode and the membrane was equivalent to a microelectrode array in this condition. When the hole in membrane was large or the distance between membrane holes was small, the CV curve of the Cl anion transfer across membrane showed peak shape, which attributed to linear diffusion. In ac impedance measurement, the impedance spectrum of the membrane system was composed of two semicircles at low de bias, corresponding to the bulk characteristics of the membrane and the kinetic process of ion transfer, respectively. The bulk membrane resistance increases with increasing dc bias and only one semicircle was observed at higher dc bias. The parameters related to kinetic and membrane properties were discussed.

  • PDF

탄산화 복합환경시 염소이온 확산에 관한 연구 (Influence of Carbonation for Chloride Diffusion in Concrete)

  • 오병환;이성규;이명규;정상화
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.179-189
    • /
    • 2005
  • 철근콘크리트 구조물의 성능저하와 관련되어 외부염소이온의 침투에 따른 철근부식은 가장 빈번하게 발생하는 현상으로 이에 따른 사용수명의 예측을 위해서는 Fick의 확산법칙을 이용한 염소이온 확산해석 방법에 대해 많은 연구가 수행되어왔다. 그러나, 탄산화가 복합적으로 작용하는 경우에 대한 연구는 최근에 이르러 수행되고 있는 실정이며 이에 따라 본 연구에서는 탄산화가 복합적으로 작용하는 경우 외부염소이온 침투에 대한 실험결과와 Fick의 확산방정식에 따른 예측결과를 비교하여 이의 타당성을 검토하였다. 이 경우 Fick의 확산방정식에 따른 깊이별 염소이온농도 예측결과는 탄산화 영역에서의 염소이온 해리에 따른 염소이온 침투촉진 현상을 적절히 반영하지 못하고 있는 것으로 나타났다. 그러나, 침지실험으로부터 구한 표면염소이온 농도 및 염소이온 확산계수를 사용하는 경우 탄산화 영역보다 깊은 영역에서의 염소이온농도는 실험결과와 비교적 일치하였다. 한편, 전기적인 촉진법에 의해 구한 염소이온 확산계수를 Fick의 확산방정식에 사용하는 경우 단순 건습반복 실험에 따른 깊이별 염소이온농도는 적절히 예측할 수 있지만 탄산화가 복합적으로 작용하는 경우에 예측된 염소이온농도는 실험결과와 많은 차이를 나타내었다. 이로부터 탄산화가 복합적으로 작용하는 경우 외부염소이온 침투정도를 조기에 예측하기 위해서는 콘크리트의 염소이온 확산계수를 적절히 측정하기 위한 새로운 방법이 요구되는 것을 알 수 있다.

콘크리트내로 침투하는 염소이온 반응형 부식센서의 응답특성에 미치는 센서 세선 수의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete)

  • 이현석;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.143-152
    • /
    • 2014
  • 본 연구에서는 콘크리트내로 침투하는 염소이온을 모니터링하기 위하여, 스크린프리트 기법으로 염소이온 반응형 부식센서를 개발하고, 센서의 세선 수가 부식반응도 및 민감도에 미치는 영향을 실험을 통하여 정량적으로 분석하였다. 개발된 부식센서를 이용하여 염소이온량에 따라 부식 반응도을 확인하였으며, 센서의 파괴정도에 따른 저항변화에서는 단선형 센서보다 다선형 센서에서 큰 저항 변화를 나타내었다. 또한, 부식센서는 NaCl 수용액의 농도가 높은 만큼 센서의 저항변화가 크고, 콘크리트 내에서 센서 종류에 따른 부식저항은 단선형보다 다선형에서 민감도가 높게 나타났으며, 센서의 매설깊이가 클수록 저항변화 사이클 (cycle)은 증가하였다. 이상의 결과로, 본 연구에서 개발된 부식센서는 염분에 대한 부식반응과 민감도, 저항의 변화를 감지할 수 있었으며, 특히 7세선이 우수한 결과를 나타내어, 염분의 침투정도를 모니터링 하는데 가장 적합하다고 판단된다.

플라이 애쉬 치환율에 따른 콘크리트의 염소이온 투과특성 (Effect of Fly-Ash on the Characteristic of Chloride ion Penetration in Concrete)

  • 하재담;김태홍;유재상;이종열;박찬규;김상윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.39-42
    • /
    • 2002
  • Cloride attack of concrete is one of the important causes of corrosion of reinforcing steel in concrete with carbonation and frost damage. In this paper, the effect of fly-ash on the cloride attack were investigated by varying water binder ratio and fly-ash contents according to the chloride ion penetrationa test. (ASTM C 1202-94) The principal conclusions from this research were as follows: 1) The compressive strength of concrete at large ages, depends more on $C_2$S contents of base cement than fly-ash contents. 2) On the other hand, the chloride ion penetration of concrete at large ages, principally depends on fly-ash contents and the influence of type of base cement is insignificant.

  • PDF

재령에 따른 시멘트 경화체내 염화물 이온의 거동에 관한 연구 (A Study on the Behavior of Chloride Ion in Hardened Cement Paste at Defferent Stages of Curing)

  • 문소현;소승영;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.185-190
    • /
    • 1998
  • Corrosion of steel reinforcement is the most significant factor of deterioration in reinforced concrete structures. Chloride ion is considered one of the most common culprits on the corrosion of steels in concrete. The main objective of this study is understanding behavior of chloride ion in hardened cement pastes at different stages of curing. Cement pastes with water-cement ratio of 0.5 are allowed to hydrate in sealed containers for 28, 70, 180 days. And than pore solution is expressed. It was found that the $Cl^-$ concentrations in pore solution is decreased with increasing curing time in all Nacl addition level, the $OH^-$ concentrations is increased to 70 days but decrease at 180 days in all Nacl addition level. The $Cl^-$/$OH^-$ in pore solution is increased with increasing curing time in all Nacl addition level, however $Cl^-$/$OH^-$ of maximum Nacl addition level(Nacl 0.54% by weight of cement) is under the onset of depassivation level 0.3.

  • PDF