• 제목/요약/키워드: Chip Flow

검색결과 315건 처리시간 0.022초

랩온어칩을 위한 중합효소 연쇄반응 칩의 열설계 (Thermal Design of PCR Chip for LOC)

  • 김덕종;김재윤;박상진;허필우;윤의수
    • 연구논문집
    • /
    • 통권33호
    • /
    • pp.17-25
    • /
    • 2003
  • In this work, thermal design of a PCR chip for LOC is systematically conducted. From the numerical simulation of a PCR chip based on the finite volume method, how to control the average temperature of a PCR chip and the temperature difference between the denaturation zone and the annealing zone is presented. The average temperature is shown to be controlled by adjusting heat input and a cooler as well as a heater is shown to be necessary to obtain three individual temperature zones for polymerase chain reaction. To reduce the time required, a heat sink for the cooler is not included in the calculation domain for the PCR chip and heat sink design is conducted separately by using a compact modeling method, the porous medium approach.

  • PDF

드릴구멍 상사성이 칩형상에 미치는 영향 (Effect of Geometrical Similarity between Twist Drill on the Shape of Chip Produced.)

  • 최만성
    • 한국생산제조학회지
    • /
    • 제9권6호
    • /
    • pp.118-126
    • /
    • 2000
  • In this study, geometrical similarity conditions for drills of various diameters are discussed. The effect of geometrical similarity on the chip shape and forces of different sized conventional drills has been experimentally confirmed. Drilling tests are carried out for SM45C by using the conventional HSS drills. The torque and thrust forces are measured and compared with those chip forms. Chip shape in drilling are affected by three factors being flow angle, side and up curl of the chip. It is found that the feedrate and drill diameter are more affected than cutting speed on the chip form and cutting forces. The similarity conditions gives easily to estimate the chip shape, the thrust and the torque for drills of different diameters.

  • PDF

Assay development and HTS on microfluidic Lab-on-a-chip

  • Yang, Eun-Gyeong
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2002년도 창립10주년기념 및 국립독성연구원 의약품동등성평가부서 신설기념 국재학술대회:생물학적 동등성과 의약품 개발 전략을 위한 국제심포지움
    • /
    • pp.73-78
    • /
    • 2002
  • Microfluidic lab-on-a-chip (LOC) systems have enabled a new generation ofassay technologies in chemical and biomedical sciences. Caliper's microfluidic LOC systems contain a network of microscopic channels through which fluids and chemical are moved in order to perform experiments. The main advantages of these continuous-flow devices are integration and automation of multiple steps in complex analytical procedures to improve the reproducibility of the results, and eliminated the manual labor, time and pipetting errors involved in analyses. The present talk is devoted to give a brief introduction of microfluidic basics and to present in applying continuous-flow microchips to drug screening with model enzyme assays.

  • PDF

IP-R&D를 통한 자동차분야 LED사업전략에 관한 연구 : Flip-Chip을 채용한 CSP (Chip-Scale Packaging) 기술을 중심으로 (A Study on Automotive LED Business Strategy Based on IP-R&D : Focused on Flip-Chip CSP (Chip-Scale Packaging))

  • 류창한;최용규;서민석
    • 반도체디스플레이기술학회지
    • /
    • 제14권3호
    • /
    • pp.13-22
    • /
    • 2015
  • LED (Light Emitting Diode) lighting is gaining more and more market penetration as one of the global warming countermeasures. LED is the next generation of fusion source composed of epi/chip/packaging of semiconductor process technology and optical/information/communication technology. LED has been applied to the existing industry areas, for example, automobiles, TVs, smartphones, laptops, refrigerators and street lamps. Therefore, LED makers have been striving to achieve the leading position in the global competition through development of core source technologies even before the promotion and adoption of LED technology as the next generation growth engine with eco-friendly characteristics. However, there has been a point of view on the cost compared to conventional lighting as a large obstacle to market penetration of LED. Therefore, companies are developing a Chip-Scale Packaging (CSP) LED technology to improve performance and reduce manufacturing costs. In this study, we perform patent analysis associated with Flip-Chip CSP LED and flow chart for promising technology forecasting. Based on our analysis, we select key patents and key patent players to derive the business strategy for the business success of Flip-Chip CSP PKG LED products.

미세유동시스템 내에서의 입자의 위치제어 연구 (Control of the Motions of Particles in Microfluidic System)

  • 허윤석
    • 한국정밀공학회지
    • /
    • 제31권6호
    • /
    • pp.521-525
    • /
    • 2014
  • Circulating tumor cells (CTCs) in the bloodstream of cancer patients provide an accessible source for detection, characterization, and monitoring of nonhematological cancers. The effectiveness of the CTC-Chip for the isolation of ovarian cancer cells was demonstrated by adapting the herringbone-chip (HB-Chip). The motions of the particles on the HB chip were simulated by a unique combination of buoyant, gravitational forces, and helical flows with a computational modeling. The motions of cells are demonstrated by applying polystylene bead and ovarian cancer cells into the microfabricated HB-Chip. The experimental results from beads and cells are well accordance with the simulated ones, as previously reported by Toner group. Thus, I expect that these modeling and experimental skills will play key roles in the clinical applications on CTC isolation as well as the basic research on characterization of CTCs under flow.

Micro On-Off Valve 해석에 의한 최적 설계 (The optimal design by Micro On-Off Valve analysis)

  • 김동수;박상운;고창섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.285-290
    • /
    • 2005
  • Micro On-Off valves are currently recognized as the core technology in the fields of the micro fluid chip fur medical applications and production lines of semi-conduct chip. Micro valves that operate by compressed air need the high-speed responsibility, repeatability, the absorbability and the uniform pressure by the poppet. In this study, Micro On-Off valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

연속흐름 중합효소연쇄반응칩 제작을 위한 인듐 산화막 전극의 특성분석 (Characteristics of Indium-Tin-Oxide electrode for continuous-flow PCR chip)

  • 정승룡;이인제;김준혁;김한수;김재완;최영진;강치중;김용상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1386-1387
    • /
    • 2006
  • PDMS와 ITO 유리를 이용하여 continuous-flow PCR chip을 제작하였다. PDMS를 이용하여 microchannel을 형성하여 주었고, ITO electrode를 heater와 sensor로 사용하기 위하여 반도체 공정을 통해 패턴을 형성하였다. microchannel내에 흐르는 시료의 온도를 제어하기 위하여 heater와 sensor를 calibration을 하였다. ITO heater는 인가된 전압에 대해 매우 선형적인 발열을 하였으며, ITO sensor는 온도에 대해 선형적인 저항 변화를 나타낸 바, 그 결과 continuous-flow PCR chip의 정확한 온도 제어가 가능하였다.

  • PDF

Effects of Ionic Strength in the Medium on Sample Preconcentration Utilizing Nano-interstices between Self-Assembled Monolayers of Gold Nanoparticles

  • Nguyen, Ngoc-Viet;Wu, Jian-Sheng;Jen, Chun-Ping
    • BioChip Journal
    • /
    • 제12권4호
    • /
    • pp.317-325
    • /
    • 2018
  • This paper investigated the effects of ionic strength in the medium on a preconcentrator for a protein sample with low concentration. The preconcentration chip was designed and fabricated using a polydimethylsiloxane replica through standard lithophotography. A glass substrate is silanized prior to functionalizing the nanoparticles for self-assembly at a designed region. Due to the overlap of electrical double layers in a nanofluidic channel, a concentration polarization effect can be achieved using an electric field. A nonlinear electrokinetic flow is induced, resulting in the fast accumulation of proteins in front of the induced ionic depletion zone, so called exclusion-enrichment effect. Thus, the protein sample can be driven by electroosmotic flow and accumulated at a specific location. The chip is used to collect fluorescein isothiocyanate-labeled bovine serum albumin (FITC-BSA) diluted in phosphate-buffered saline (PBS) buffer solution. Different concentrations of the buffer media were studied herein. Fluorescence intensity images show that the buffer concentration of 4 mM is more appropriate than all the other ones. The sample of FITC-BSA with an initial concentration of $10{\mu}M$ in the 4 mM PBS solution increases its concentration at the desired region by up to 50 times within 30 min, demonstrating the results in this investigation.

원형 충돌제트를 이용한 Pedestal 형상의 핀이 부착된 Chip 냉각 (Round Jet Impingement Heat Transfer on a Pedestal Encountered in Chip Cooling)

  • 정영석;정승훈;이대희;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.546-552
    • /
    • 2001
  • The heat transfer and flow measurements on a pedestal encountered in chip cooling. A uniform wall temperature boundary condition at the plate surface and on a pedestal was created using shroud method. Liquid crystal was used to measure the plate surface temperature. The jet Reynolds number (Re) ranges from 11,000 to 50,000, the dimensionless nozzle-to-surface distance (L/d) from 2 to 10, and the dimensionless pedestal diameter-to-height (H/D) from 0 to 1.0. The results show that the Nusselt number distributions at the near the pedestal exhibit secondary maxima at $r/d{\cong}1.0\;and\;1.5$. The formation of the secondary maxima is attributed to an create in the vortex by the pedestal.

  • PDF